Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance NEAR RAMNAGAR ROAD NO 2 AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799002 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance JOYNAGAR MIDDLE ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹15.8 L
EMD Value
₹31,688
Closing Date
25 Apr 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer Mechanical Division Agartala
Providing IC of 1 5 TR 20 TR High wall and 3 point 65 TR Floor mounted vertical Split type AC system in different locations Newly constructed seminar Room and Eye OT Dept of Ophthalmology Research Lab and Demonstration Biochemistry OPD Dept of PMR
2025_CEPWD_60180_1
108_EE_DNIeT_MECH DIVN_AGT_2024_25
Open Tender
Electrical Works
Works
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹31,688
Yes
25 Apr 2025
8 Apr 2025
25 Apr 2025
8 Apr 2025
25 Apr 2025
8 Apr 2025
Amount
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
1.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt).
2.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt).
Providing 3 star rated (Minimum 3 star with applicabls ISEER accordlng to current industry standard) Floor mounted vertical Split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption suitable for operation on 420 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
3.65 TR floor mounted vertical Split type AC machine (Minimum rated cooling capacity should not be less than 10950 Kcl/hr ) or 43800 BThu/h or 12775 watt).
Standard installation, testing and commissioning of 1.5 / 2.0 TR high wall split type AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 3.65 TR floor mounted vertical Split type AC machine including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of 1.5 / 2.0 TR high wall split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Fabrication of M.S platform of appropriate size, base plate, nuts and bolts/ universal bracket (GSS) for both IDU and ODU of 3.65 TR floor mounted vertical Split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe of appropriate size of (5/8" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units suitable for 1.5 / 2.0 TR high wall type / 3.65 TR floor mounting vertical Split type ACs.
Providing hard UPVC pipe of best quality of nominal 3/4 " dia. including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
R.P.ELECTRONICS (BID ID -172936)
stage.html
html • 0.02 MB
finance_61195.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .