| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC DURGABARI PARA GANGARAMPUR DAKSHIN DINAJPUR 733124 W B | GANGARAMPUR | DAKSHIN DINAJPUR | WEST BENGAL | 733124 | ₹1.4 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹1.4 LRejected-Finance CHAKBHABANI RATHULA BALURGHAT DAKSHIN DINAJPUR 733101 | BALURGHAT | DAKSHIN DINAJPUR | WEST BENGAL | 733101 | ₹1.4 L | L2 | Rejected-Finance L2 BIDDER |
| 3 | L3₹1.4 LRejected-Finance | ₹1.4 L | L3 | Rejected-Finance L3 BIDDER |
| Sl No | Description | Qty | Unit | MILLENNIUM ENGINEERS CO OP SOCIETY LTD L2 | M/S Basak Electrical Repairing House L3 | MAHABIR ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Opening testing the 56"/48"celling are cutting the burnt out coils from the starter after cleaning the stator coils. Rewinding the starter coils with supper enameled copper wires of approved guage including backing varnishing and testing complete. | 50 | Each | 489 ₹24,450 | 488 ₹24,400 | 487.9 ₹24,395 |
| 2.00S & F new ball bearing ( make- TATA 6201,6202) | ||||||
| 2.01 | TATA-6201 | 45 | Each | 96 ₹4,320 | 96 ₹4,320 | 95.2 ₹4,284 |
| 2.02 | TATA-6202 | 46 | Each | 107 ₹4,922 | 108 ₹4,968 | 107.1 ₹4,926.60 |
| 3.00 | Supply & fixing oil filled capacitor. (2.5 Mfd, make- P2 type (Make- Universel/tibcon). | 40 | Each | 54 ₹2,160 | 55 ₹2,200 | 53.55 ₹2,142 |
| 4.00 | S &F of new split pin. On existing fan | 42 | Each | 7 ₹294 | 8 ₹336 | 7.14 ₹299.88 |
| 5.00 | Charges for damage loop wire incl. s& f new loop wire by PVC flex. cu. wire from stator coil. | 50 | Each | 44 ₹2,200 | 44 ₹2,200 | 42.84 ₹2,142 |
| 6.00Costing for rewinding the wall fan coil with approved copper wire incl. Vernishing heating etc | ||||||
| 6.01 | 450 mm sweep | 6 | Each | 574 ₹3,444 | 560 ₹3,360 | 571.2 ₹3,427.20 |
| 7.00 | Shaft change of 450 mm sweep wall fan | 6 | Each | 101 ₹606 | 110 ₹660 | 101.15 ₹606.90 |
Tender Value
Refer Docs
EMD Value
₹2,732
Closing Date
13 Jan 2026, 12:00 pmClosed
Asst. Engineer, BESD
Purta Bhavan, 4th Floor, Kachari Raod, Balurghat, Dakdhin Dinajpur pin 733101
Repairing of ceilling fans and other E.I Work under Gangarampur Sub Divisional Hospital and cable laying under Kushmandi Rural Hospital in the District of Dakshin Dinajpur.
2025_WBPWD_977058_1
WBPWDTE/AE/BESD/e-NIQ-41 of 2025-26
Open Tender
Electrical Work/ Equipment
Balurghat
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,732
12 Mar 2026
19 Dec 2025
15 Jan 2026
20 Dec 2025
13 Jan 2026
24 Dec 2025
Opening testing the 56"/48"celling are cutting the burnt out coils from the starter after cleaning the stator coils. Rewinding the starter coils with supper enameled copper wires of approved guage including backing varnishing and testing complete.
S & F new ball bearing ( make- TATA 6201,6202)
Supply & fixing oil filled capacitor. (2.5 Mfd, make- P2 type (Make- Universel/tibcon).
S &F of new split pin. On existing fan
Charges for damage loop wire incl. s& f new loop wire by PVC flex. cu. wire from stator coil.
Costing for rewinding the wall fan coil with approved copper wire incl. Vernishing heating etc
450 mm sweep
Shaft change of 450 mm sweep wall fan
Extra for supplying additional 1 Mtr. down rod with 2x1.5 sqmm flexible copper wire.
Carrying charges for ceiling fans from our work site to co. work shop and backing including loading and unloading for new winding.
Supply & Delivery 1.1KV grade XLPE insulated Armoured Aluminium conductor cable (Finolex/Polycab/ Gloster) [N.S]
4 Core 35 sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [Page No. F-2, Item no. 1(a)]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core [Page No. F-1, Item no. 3(a)]
Supplying & fixing of medium gauge GI Pipe (Make- BANSAL ISI-Medium/ UTKARSH ISI-Medium/ JINDAL ISI-Medium/ BHUSAN ISI-Medium) Protection with necessary fittings and jointing metarials as required [Page No. F-6, Item no. 11] a) 50 mm dia
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [Page No. F-4, Item No. 7]
4 Core 35 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials [Page No. F-5, Item No. 8]
4 Core 35 sqmm
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-Polycab/Finolex/Gloster) in 20 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required [Page No. E-14, Item No. 1(a)]
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/03 (2.5 sqmm) 1x 22/03 (1.5 sqmm) ECC
Finishing of the PVC insulated wire ends by sockenting with pin ring type copper sockets and insulated tapes etc, including supplying sockets, tapes [Page No. F-5, Item No. 9]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [C-2/ 17]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC [Page No. E-20, Item No. 1 (iii)]
Average run 8 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish [Page No. E-20, Item No. 3 (i)]
On Board
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [Page No. E- 18, Item No. 9(b) ]
Supply & Fixing 240 V, 2 nos16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 2 Nos 16A Modular type switch, without plug top on 8 Module GI Modular type switch board with 8 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [Page No. E-18, Item No. 9 ]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Page No. E-18, Item No. 12 ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [Page No. C-3, Item no. 21(a)]
Supply & Delivery of 250 Volt, 50Hz 1200mm sweep 1-phase AC ceiling fans incl. all accss., the capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan, complete with blades, canopy, fork, rubber bush etc. (Make-USHA -STRIKER 1 STAR With Safety wire/Crompton, Model- Riviera High Speed or Make -Orient Electric, Model- Summer King)[N.S.]
Supply & Delivery LED Tube for existing fittings 250 Volt, 4 Ft. long 18 Watt/20 watt , 2100 lm, LED Tube (Philips- Master LEDTube) (Make- Philips/ Crompton Model-LGT8-20-865-2) [N.S.]
Supply & Delivery 250 Volt, 4 Ft. long 18 Watt Single Fluo. Tube Light fittings (TMC 501 P 1XT-LED 22W P3241) (Make- Philips)/ make-Crompton Model-IS-340-NWH [N.S.]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
2 Module
6 Module
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.96 MB
Tendernotice_2.pdf
PDF • 1.24 MB
Tendernotice_3.pdf
PDF • 0.49 MB
BOQ_2380471.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid