| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹21.9 L+₹3.1 L (16.6%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹22.2 L
EMD Value
₹44,400
Closing Date
15 Feb 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-69/2021-22 ADDITION / ALTERATION TO CERTAIN PORTION OF BUILDING NO. P-883 AND CERTAIN MINOR WORKS AT AF STATION AMBALA UNDER GE (AF) AMBALA
2022_MES_503411_1
GE AF/AMB-69/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹44,400
Yes
8 Mar 2022
24 Jan 2022
17 Feb 2022
24 Jan 2022
15 Feb 2022
2 Feb 2022
28 Jan 2022 - 31 Jan 2022
60 days
Amount
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
Dismantling stone slabs / tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar and disposing off complete all as specified and as directed
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundation, filling, mass concrete, etc. complete all as specified and as directed
M&L for plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in coping, drain channels, etc. complete all as specified and as directed
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4) complete all as specified and as directed
S&F steel work in tubular trusses including special shaped washer etc. using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 fixed in position inlcuding all necessary staging, etc. complete all as specified and as directed
S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. not exceeding 10kg each brackets, conforming to Fe-290 grade E-165 complete all as specified and as directed
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 10mm complete all as specified and as directed
M&L for MS framed works as in doors or gates of angle or other section with gusset plates, rails, braces, etc. drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe-410-W grade E-250 quality-A complete all as specified and as directed
M&L for mild steel 25x5mm flat iron for hold fasts conforming to Fe-410-0 complete all as specified and as directed
M&L for vitrified tiles, coloured, 10mm thick, joint free, edge cut, area of each tile not exceeding 0.36sqm, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles laid over and including of 15mm thick bedding layer in CM 1:6 (cost shall be inclusive) complete all as specified and as directed
M&L for vitrified tiles, coloured, 10mm thick, joint free, edge cut, area of each tile not exceeding 0.36sqm, of superior quality as in skirting, dado, vertical surfaces, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles laid over and including of 10mm thick backing coat in CM 1:4 (cost shall be inclusive) complete all as specified and as directed
M&L for rendering 15mm thick in cement mortar (1:4) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, etc. finished fair and even without using extra cement complete all as specified and as directed
M&L for preparation of old masonry / concrete surfaces of walls, etc. by scrapping off old finish, washing down and applying two coats of oil emulsion distemper over a coat of 3mm thick wall care putty including all necessary staging, scaffolding, etc. as required complete all as specified and as direct
M&L for preparation of new masonry / concrete surfaces of walls, etc. and applying two coats of oil emulsion distemper over a coat of 3mm thick wall care putty including all necessary staging, scaffolding, etc. as required complete all as specified and as direct
M&L for preparing of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer including all necessary staging, scaffolding, etc. as required complete all as specified and as directed
M&L for preparation of old masonry / concrete surfaces of ceilings, soffits, etc. by scrapping off old finish, washing down and applying one coat of white wash including all necessary staging, scaffolding, etc. as required complete all as specified and as direct
S&F aluminium anodized door shutters and frame fabricated out of hollow extruded aluminium sections (as detailed below), each shutter having 2Nos. aluminium hinges 100mm long, 1No. lock type aluminium handle 100mm, 2Nos. 150mm long aluminium tower bolts and including 5mm thick tinted glass fixed with glazing clips, rubber beading, gaskets, aluminium beading screws, etc. as required complete all as shown on drawing, as specified and as directed Details: Shutter (vertical/style) size - 83.5x44.45mm x1.5mm thick Shutter (middle rail) size - 83.5x44.45mm x1.5mm thick Chowkhat frame size - 101.6x44.45mm x1.5mm thick Notes: (i) Drawings shall be referred at GE (AF) Ambala (ii) Minimum thickness of anodisation shall be 15microns
S&F anodised (minimum thickness of anodising shall be 15microns) aluminium partition wall, fabricated, size of members 100x44x1.6mm, including making provision for opening, etc. and all necessary cleats, panel inserts not more than 1.44sqm and arrangement to receive and including 5.5mm thick glass and 19mm thick pre-laminated particle board with aluminium beading, glazing cleats, and stainless steel screws, rubber gaskets, beading, etc. complete all as specified and as directed
S&F in position aluminium-zinc colour coated high tensile alloy steel trap corrugated sheeting of 0.5 to 0.53mm thick, high rib, having 550 Mpa yeild strength BMT 0.45mm and zinc (galvanized) and aluminum combined coating of 150 gms/sqm (AZ-150) of 0.50mm TCT having top colour coat of regular modified polyester/silicon modified polyester/HDPE polyester of 18 to 20micron and back coat of 5 to7 micron epoxy primer fixes, RMR 1040 profile width 1125mm in roofing panels / sheeting / ridges complete as per manufacturer's instructions, all as specified and as directed Note: The sheet shall be fixed to MS angles with self drilling and self topping screws conforming to AS 3566 with moulded EPDM washers
S&F in position aluminium-zinc colour coated high tensile alloy steel trap plain sheeting of 0.5 to 0.53mm thick, high rib, having 550 Mpa yeild strength BMT 0.45mm and zinc (galvanized) and aluminum combined coating of 150 gms/sqm (AZ-150) of 0.50mm TCT having top colour coat of regular modified polyester/silicon modified polyester/HDPE polyester of 18 to 20micron and back coat of 5 to7 micron epoxy primer fixes, RMR 1040 profile width 1125mm in roofing panels / sheeting / ridges complete as per manufacturer's instructions, all as specified and as directed Note: The sheet shall be fixed to MS angles with self drilling and self topping screws conforming to AS 3566 with moulded EPDM washers
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 3.5 core 70sqmm, 1100V grade, screwed PVC bedded, armoured electric power cable, heavy duty, stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. complete all as specified and as directed Note: Excavation and earthwork will be measured and paid separately under respective item herein
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 19mm dia and conduit accessories concealed on walls, ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 5A one way switch
One switch socket outlet 3 pin 5A on independent board
One switch socket outlet 3 pin 5A on same board
One bell point controlled by one bell push
M&L for point wiring 2 runs of 2.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 19mm dia and conduit accessories concealed on walls, ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for 3 pin 15/16A switch socket power point on independent board complete all as specified and as directed
M&L for point wiring, concealed type, with 1.5sqmm single core multistranded copper conductor ZHFR PVC insulated and unsheathed cable 1100V grade drawn through and including rigid metallic steel ERW conduit, minimum 20mm dia, ISI marked and all conduit accesories concealed in wall/celing/roof, etc. with sunken type pressed steel/welded MS terminal boxes made out of 1.6mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings, switches, sockets outlets, regulators, etc. including provisioning of 1.5sqmm ZHFR PVC insulated unsheathed cable 1100V grade with multi-standed copper conductor to common earth dolly for earth wire for flame proof fittings/light/fan/exhaust fan point complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of twin core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 2.5sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including steel conduit 19mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories, making good the disturbed surfaces in CM 1::4 and applying two coats of distemper oil emulsion complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of twin core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 1.5sqmm and 1 run of 1.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories, making good the disturbed surfaces in CM 1::4 and applying two coats of distemper oil emulsion including taking down and disposing off old submain wiring complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of twin core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 2.5sqmm and 1 run of 1.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories, making good the disturbed surfaces in CM 1::4 and applying two coats of distemper oil emulsion including taking down and disposing off old submain wiring complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of twin core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories, making good the disturbed surfaces in CM 1::4 and applying two coats of distemper oil emulsion including taking down and disposing off old submain wiring complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of twin core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories, making good the disturbed surfaces in CM 1::4 and applying two coats of distemper oil emulsion including taking down and disposing off old submain wiring complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of four core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 10sqmm and 1 run of 2 core 6sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 32mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories, making good the disturbed surfaces in CM 1::4 and applying two coats of distemper oil emulsion including taking down and disposing off old submain wiring complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of four core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 2.5sqmm and 1 run of 2 core 1.5sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories, making good the disturbed surfaces in CM 1::4 and applying two coats of distemper oil emulsion including taking down and disposing off old submain wiring complete all as specified and as directed
Notes for item Nos. 35 to 41: (i) 2 runs of main cable, 1 run of earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F in repairs sheet metal enclosures for 4 way MCCB incomer + 12 module outgoings, vertical type, TPN, load line distribution board with provision for mounting of MCCB 100A as incomer, double door IP 54 protection class conforming to IS 8623-III, with 160A rated bus bar, blanking plates duly flushed in wall and making good the disturbed surfaces including 1No. MCCB 100A, 4 pole, 16kA complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V, SPN, 8 way, double door type, flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V, SPN, 4 way, single door type, flushed inside wall with 100A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
S&F in repairs MCCB 4 pole 3 Phase 415V 200A 36kA adjustable thermal release type complete all as specified and as directed
S&F in repairs MCB SP, 240V, 5 to 40A, 10kA, 'C' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F in repairs MCB SP, 240V, 5 to 32A, 10kA, 'B' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F in repairs MCB SP, 240V, 40A, 10kA, 'B' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F in repairs MCB SPN, 240V, 20 to 32A, 10kA, 'B' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F in repairs MCB SPN, 240V, 5 to 40A, 10kA, 'C' curve, finger proof terminal, bi-connect termination, 35sqmm terminal capacity, insulated sliding shutter with large two position dolly complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 5/6A, 240V complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 15A, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 5A flush type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, 2 in 1, 3 pin, multipurpose 15A flush type, ISI marked, 240V complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F PVC lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and as directed
S&F bell push flush button type, 5A, 240V complete all as specified and as directed
S&F bell buzzer, ding dong type, 240V, single pole complete all as specified and as directed
S&F energy efficient BEE five star rated ceiling fan, 230/240V, single phase, 1200mm sweep and connecting up with provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to ceiling fan complete all as specified and as directed
S&F flame proof, heavy duty, metalic body with metalic blades, legs, ISI marked energy efficient BEE five star rated exhaust fan, 457mm sweep, 1440RPM, CFM 4000 with lauvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including making hole on wall grouting bolts nuts washers, etc. complete all as speceified and as directed
S&F flame proof weather proof LED tube light fitting 2x16W, 240V, 4' long, suitable for gas / vapour group IIA & IIB and zone 1&2, IP- 65 protection class, with die cast aluminium housing, heat resistant toughened glass, with 16W tube lamps including driver, holder, connector, etc. with all accessories pre-wired and connecting with ZHFR grade three core twisted flexible copper conductor cable and testing on installation including taking down old fittings and disposing off complete all as specified and as directed
S&F in repairs recess/surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36W, PF 0.9, CRI> 70, L 70 with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod including taking down old fittings and disposing off complete all as specified and as directed
S&F energy efficient LED light fitting, 45W, input voltage 110V to 280VAC, 50Hz with ingress protection IP 66, LM 80, stranded luminries with efficiency 100lumen/Watt, with secondary optics, perfectly matched lenses, complying to IEC60598/IS10322, with auto shut down on high voltage, CRI>70, PF>0.95, with short circuit & reverse circuit protection against 10kV high surges, minimum 50000 burning hours (life), operating temperature 1 to 50oC, rectangular shape with pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 60W=10%W, rated lumens, 120o view angle, constant current type driver having THD<10%, including all fixing arrengment like clamps, nuts, bolts, washers, 45W LED rod lamp (havng PF>0.9, input voltage 90-300V, IP-66, LM80) with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking out and disposing old fitting any type complete all as specified and as directed
S&F LED tube light fitting 1x18W, 230V, PF 0.9, CRI> 70, L 70, in commercial channel with powder coated CRCA sheet housing with opal diffuser for LED with LED tubelight with high efficient LED in aluminium housing with clear & milky diffuser with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod including taking out and disposing old fitting any type complete all as specified and as directed
S&F flame proof rotary type switch with termination box in aluminium alloy LM6 SP 16A 250V with wire guard complete all as specified and as directed
Supplying, fixing / laying steel water tubing, 50mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed
M&L for making bore suitable for drawing 50mm bore passing through pipe for passing cable, etc. in road, path, hard standing, etc. of any type and making good the disturbed surfaces, etc. complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for cable jointing kit, indoor / outdoor termination type, for 1100V grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core, 70mm², XLPE insulated armoured aluminium conductor cable complete all as specified and as directed
M&L for cable jointing kit, indoor / outdoor termination type, for 1100V grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core, 50mm², XLPE insulated armoured aluminium conductor cable complete all as specified and as directed
S&F metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket with and inlcuding one SP MCB 20A 10kA including taking down and disposing off old/unserviceable socket complete all as specified and as directed
S&F industrial plug and socket 16A 5 pin (3P+N+E) having protection IP-40 including 1No. MCB 4 pole, 32A 10kA with sheet metal enclosure fixed on walls with fixing screws and making all connections complete all as specified and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws complete all as specified and as directed
S&F bus bar chamber of size 600x600x450mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 300A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed
Supply, installation, testing & commissioning of powder coated compartmentalized LT panel, of suitable size, front and back openable, outdoor type, with louvers and air vents, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with rated copper bus bar 3 phase 300A and half neutral, internally connected with copper strip of appropriate size, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), panel of IP-54 protection class, conforming to IS-13947, fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 415V, 50Hz supply with cable ally on both sides, gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in ground in platform (as per manufacturer's instructions) painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the following switchgears complete all as specified and as directed (i) MCCB three phase adjustable type with thermal magnetic release 160A 36kA four pole - 1No. (ii) Onload changeover switch 160A 415V four pole - 1No (iii) MCCB three phase adjustable type with thermal magnetic release 100A 26kA four pole - 3Nos. (iv) Digital ampere meter and voltmeter (v) Indcating lamps (RYB) - 1 set
Supplying, installing, testing, commissioning diesel engine driven generating set 415V, 3 phase, 4 wire as per BS-5514/IS-10002 with standard control panel of continuous rating 30KVA / 24KW at NTP conditions with acoustic enclosure and canopy complete all as comprising of the following and as detailed hereinafter, as specified and as directed
item No. 78 contd (A) Alternator Self regulated with brushless self execution 100kVA 415V 3 phase 4 wire, 50Hz, 0.8PF, 1500RPM with voltage variation +2.5% of rated voltage from no-load to full-load, floor mounted, screen protected drip proof, class 'F' insulation, closed coupled single bearing alternator with necessary controls as per manufacturer recommendations, conforming to BS-5000/IS-4772 capable of supplying unbalanced load (B) Engine Multi-cylinder, compression ignition, heavy duty, compact iesl engine liquid cooled with all standard accessories as per BS-5514/ ISO-3046, 1500RPM, with control gauges, RPM/hour meter, etc. shaft HP suitable for generating application and capable of giving an output of 30KVA/24KW for coupled alternator under NTP conditions with the following: (a) Flywheel housing with flywheel to suit closed coupled single bearing alternator (b) Air-cleaner dry type with vacuum indicator (c) Fuel pump and fuel piping 15mm MS pipe with bends, flanges, etc.
item No. 78 contd (d) Fuel filter with water separator and filter element (e) Lub-oil filter with filter element (f) DC starter 12V (g) Storage batteries of suitable voltage and ampere hours as recommended by the manufacturer (h) Residential silencer as per CPCB norms (j) Supporting / fixing arrangements for muffler with ceiling through anti-vibration pads (k) Engine overspeed stop / trip switch (l) Radiator with fan (m) Dynamo for battery cahrging (n) Corrosion inhibitor coolant (o) Engine control panel electric digital display type consisting of battery voltage indicator, lub-oil temeprature and pressure gauges, coolant water temperature gauge RPM indicator cum hour meter (p) Safty control for alarm due to hih water temperature and low lub-oil pressure (q) Any other devices / accessories as recommended and or supplied by the manufacturer as standard equipment
item No. 78 contd. (o) Frequency meter diital type of suitable rating (p) 1No. MCCB 1200A 4 pole 25kA and 1No. MCCB 100A 4 pole 25kA with fixed thermal and magnetic release for main supply and DG supply with adjustable overload and adjustable short circuit (q) The AMF panel shall have manually bypass arrangement in case of failure of AMF panel (r) Other accessories as per manfacturer's instructions and specifications (D) SKID The engine and alternator will be coupled, aligned and mounted on a specially designed common base frame fabricated from MS channel of suitale c/s area, length with bottom drilled holes suitable for and including supplying and fixing anti-vibration pads of required size and numbers as recommended by the manufacturer for proper mounting of DG set (E) Diesel Tank Diesel tank shall be of capacity 8hours continuous run on full load with calibrated scale (fuel level indicator), dip sick, fuel inlet / outlet, air vent, drain plug, inlet arrangement for direc filling including suitable sized gate valve at outlet. Tank shall be placed and fitted at suitable height
item No. 78 contd. (F) Enclosure Sound proof enclosure with residential silencer (CPCB approved) with sound less than 75dB at a distance of 1m from canopy in free field zone (G) Foundation PCC / RCC foundation shall be provided as per manufacturer's own design and specifications as approved The following are to be provided: (i) Three sets of (a) Maintenance & operation manual for engine and alternator (b) catalogue for spare parts (c) schematic diagram of control panels (ii) Manufacturer test certificates (iii) List of spares for normal maintenance for 2yrs as per manufacturer (iv) Cost of the above shall be included in the quoted rate
item No. 78 contd Notes: (i) Contractor has to submit foundation drawing for approval of the GE (ii) Drawing of DG shall be as approved by the GE (iii) Contractor shall carry out load test for 12hrs including run on 10% overload for 2hrs. Testing equipment, fuel, oil, required shall be arranged by the Contractor and cost shall be included in the quoted rate (iv) AMF panel and DG set shall be of the same manufacturer as approved
S&F copper strip of size 20x3mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F GI strip of size 32x6mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
Supply, installation, testing and commissioning maintenance free tripod chemical earthing system consisting of 3Nos. of solid copper earth rod of 17.2mm dia and 3m long made of high tensile low carbon steel, molecularly bonded with 99.9% electrolyitc grade copper on outer surface having 250microns (minimum thickness) with exothermically jointed copper bus bar of 150x25x3mm for long lasting and connecting each copper rod and the exothemically jointed bus bar, both CPRI tested on at leat 25kA fault current ensuring high current carrying capacity of the system and earth rod should be certified by laboratories confirming to comply with UL 467 international standards grounding and bonding equipment and each rod should be used with minimum 50kg earth enhancing compund that should be ROHS tested and have passed leaching sulpher, corrosion, resisitivity test shall be less than 0.05lhm mtr and international standard for earth enhancement compound by NABL acredited laboratory and each rod should be interconnected with 8mm dia copper clad steel conductor at the distance of 3m to make a shape of traingle with top of the bore finished with 40mm thick PCC in 1:2:4 type B-1, 75mm thick PCC in 1:4:8 type D-2 and back fill/JAM compund shall be covered with advanced polymer pit cover of 30x30mm size complete all as specified and as directed
Notes for item No. 87: (i) The earthing shall comply to IS 3043, UL 467, BS/EN50164-7 (ii) The earth resistance shall be less than 01Ohm. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect (iii) To obtain earth resistance less than 01Ohm, if a combination two or more earthings are to be inter-connected or the length of the electrode/s is/are to be increased it shall be measured and paid as one earthing only (iv) Testing of earthing shall be carried out in presence of Departmental rep and requisite test reports shall be submitted (v) Cost of all excavation & earthwork required shall be deemed to be included in the quoted rate
M&L for earthing using GI earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI wire of size 4sqmm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specification complete all as specified and as directed
Notes for serial item Nos. 89 & 90: (i) The cost of GI earth continuity strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
Esha Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .