| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC | ₹37.9 L Quoted ₹38.5 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹40.1 L+₹1.6 L (4.07%)Rejected-Finance | ₹40.1 L+₹1.6 L (4.07%) | L2 | Rejected-Finance Being other than L1 bidder |
| 3 | L3₹40.3 L+₹1.8 L (4.71%)Rejected-Finance | ₹40.3 L+₹1.8 L (4.71%) | L3 | Rejected-Finance Being other than L1 bidder |
| 4 | L4₹41.0 L+₹2.5 L (6.49%)Rejected-Finance | ₹41.0 L+₹2.5 L (6.49%) | L4 | Rejected-Finance Being other than L1 bidder |
| 5 | L5₹41.3 L+₹2.8 L (7.40%)Rejected-Finance | ₹41.3 L+₹2.8 L (7.40%) | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
9 Jan 2023, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Provn of one toilet block at Gambhir Bn, Provn of 01 x toilet block with Septic Tank and Soakage well at ASC and Special repair for replacement of LT OH line to UG cable and connected items at MT area of Engr Regt at Rajouri under GE 862 EWS
2022_MES_570415_1
GER-68/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Class D Cat a ( i) and b (i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹76,000
Yes
3 Feb 2023
21 Dec 2022
11 Jan 2023
21 Dec 2022
9 Jan 2023
4 Jan 2023
Amount
Sch 'A' Part-I (B/R works) Rough excavation not exceeding 1.5 m deep and getting out in soft/ disintegrated rock, complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in soft/ disintegrated rock, for foundation, etc, or for shafts, wells, drain pipes n.exc 10 Sqm on plan and getting out, complete, all as specified and directed.
Removing excavated soft/ disntegrated rock materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in hard and dense for foundation, etc, or for shafts, wells, drain pipes n.exc 10 Sqm on plan and getting out, complete, all as specified and directed.
Description all as per Serial item No 3 above, but depth exceeding 1.5m and not exceding 3.00 m, complete, all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed.
M&L formwork to sides of concrete foundation, footing, bases of colums, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar work, in rough finished flat surface of concrete, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns and the like, complete all as specified and directed
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (20mm graded stone aggregates) as in columns, pillars, piers, post, struts and the like, complete all as specified and directed
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves, including sup-ports, overhangs etc also splays between floors and beam etc, complete all as specified and directed.
M&L formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete, complete all as specified and directed.
M&L for reinforced cement concrete M-25 (design mix) (20mm graded stone aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like, complete all as specified and directed
M&L for providing reinforced cement concrete M-25 (design mix) (20mm graded stone aggregate) as in chajjas and the like, complete all as specified and directed
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide,for rough finished surfaces of concrete, complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work using old size bricks sub class 'B', straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick work, finished even and smooth without using extra cement, including water proofing compound as per manufactur's instractions, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening, complete all as specified and directed.
M&L for steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed.
S&F for 3mm thick sheet / frosted head glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
M&L for solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, complete all as specified and directed.
M&L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S . frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing mentioned in SSR Part-II 2020, complete all as specified and directed.
S&F for 100mm long butt hinges medium weight cold rolled mild steel , complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 150 mm long of extruded section (ISI marked) ,complete all as specified and directed.
S&F for extruded aluminium alloy handles size 125 mm fabricated type anodised (ISI marked), complete all as specified and directed.
S&F for vitreous China water closet (squatting pan) Orrisa pattern 680x470 mm size pan, white, with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to flushing cistern/pipe (excluding flushing cistern, flush pipe) ,complete all as specified and directed.
M&L for damp proof course 40mm thick in cement concrete 1:2:4 , type B-0 to horizontal or vertical surface including necessary formwork, complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 300x200x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick screed bed in cement mortar 1:3 complete all as specified and as directed.
M&L for rendering 5 mm thick on concrete surface in cement mortar 1:3 on ceiling, finished even and smooth with sagol cement ,complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, multy-layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 1000 ltrs tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball brass valve with union screwed for iron pipe and fixed, complete all as specifed and directed.
M&L for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including clamps or in floor, or as in weep hole, complete all as specified and directed.
M&L for 110mm bore PVC (SWR) bend any redius, provided with access door ,complete all as specifed and directed by Engr-in-Charge.
S&F for 110 mm bore PVC (SWR) branch pieces , single , (single 'Y') equal or unequal, provided with access door complete all specified and directed by Engr-in-Charge.
S&F for 110 mm bore PVC (SWR) junction , single (single 'T') equal or unequal, provided with access door, complete all specified and directed by Engr-in-Charge.
M&L for 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall with and icluding clamps or in floor, or as in weep hole complete all as specified and directed.
M&L for 75 mm dia PVC (SWR) bend any radius, provided with access door, complete all as specifed and directed by Engr-in-Charge.
S&F for 75 mm bore PVC (SWR) branch pieces, single (single 'Y') equal or unequal, provided with access door, complete all specified and directed by Engr-in-Charge.
S&F for 75 mm bore PVC (SWR) branch pieces, single (single 'T') equal or unequal, provided with access door complete all specified and directed by Engr-in-Charge.
M&L for water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in cement mortar 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed.
M&L for 100mm bore outlet cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4 & tested, complete all as specified and directed.
M&L for 75mm bore outlet cast nahani floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4 & tested, complete all as specified and directed.
S&F for 15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors, complete all as specified and directed.
S&F for 20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors, complete all as specified and directed.
S&F for PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
S&F for PVC connection 15 mm x 600 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
M&L for bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe, suitable for 15 mm bore ,complete all as specified and directed.
S&F for overhead shower of 100mm dia round shape single flow (ABS body chrome plated with grey face plate) with rubit cleaning system, complete all as specified and directed.
S&F for 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, brass chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
M&L for 15mm bore stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type,screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F for push tap 15mm bore any colour high pressure of PTMT screwed for iron pipe and fixed, (minimum weight 20mm-75 gms complete all as specified and directed.
S&F for brass chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange, aluminium anodised complete all as specifed and directed.
S&F for 100 mm dia grating PTMT with waste hole, complete all as specified and directed.
S&F for vitreous China bowl type urinal flat back of size 465x355x265 mm white (minimum), with grating and union for discharge pipe excluding flushing cistern and incluidng flush type and waste pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and inlcuding 60mm long brass screw, pointing around urinal back in cement fixing automatice flushing cistern with bracket, flush pipe, gratting and unioun for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe ),complete all as specified and directed.
S&F for soap dish (oval) type, mild steel chromium plated of approximate size 100x50x10mm ,complete all as specified and directed.
S&F for PVC flexible waste down pipe 32mm dia, complete all as specified and directed by the Engr-in-Charge.
M&L for stack clamps 75mm bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
M&L for stack clamps 100mm bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F for 75mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F for vitreous China wash basin, white, flat back, size 550x 400mm excluding taps, waste chain and plug and pocelan stopper but including brackets ,complete all as specified and directed.
M&L for 50mm thick plain cement concrete, type C-1, (1:3:6) (using 20mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for plain cement concrete 1:3:6, type-C-2 (using 40mm grade stone aggregated) as in sub base of drains etc, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4, complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc, complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in apex stone, coping, benching, hold fasts, water troughs, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed.
M&L for providing pre-cast cement concrete landing cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1 using 20mm grading stone aggregate and setting in cement morter 1:6, complete all as specified and directed
M&L for construction of LLDPE septic tank (conventional) of capacity 20 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8, type D-2 in foundation, vent shaft, connection etc including returning , filling of soil at sides of tank, well ramming in layers and removing excavated surplus soil to a distance not exc 50m, complete all as specified and directed by Engr-in-Charge at site.
M&L for construction of soakage well 1.2 m dia and 3.00 m deep including excavation and earth work in any type of soil, PCC 1:3:6, type C-2 in foundation, walls of honey combed masonry with top ring of M-25 concrete including intercerpting chamber and screen chamber made of brick masonry in cement mortar 1:4, RCC cover slab in M-25, interconnecting pipes of RCC, complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2 and as directed at site by Engr-in-Charge.
M&L for 150 mm internal dia Salt-Glazed stone ware drain pipes grade 'A' laid in trenches over concrete bedding jointed in cement mortar (1:1) and tested ,complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 ,using 40 mm graded stone aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe, complete all as specified and directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in hard / dense soil ,complete all as specified and directed.
M&L for hardcore of gauge n.exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and remmed to a true surface, complete all as specified and directed.
M&L for 75mm thick plain cement concrete , type E-2 using 40mm grade crushed stone aggregated as in foundation filling and mass concrete complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block of any shape and size approved by Engineer-in-Charge , ISI marked (IS:15658-2006) 80mm thick, M-35 grade (Heavy Traffic), in paths and hardstanding,with grey cement, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed. (Note: 20% coloured interlocking paver block with colour pigmant and 80% grey cement interlocking paver block with no pigment are used as directed by Engr-in-Charge).
M&L for 100mm thick plain cement concrete 1:2:4,, type B-2 using 40mm graded stone aggregates as in sub base, complete all as specified and directed.
M&L for chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured cement to match the shade of tiles laid over and including 20 mm thick screed bed in cement mortar 1:4, complete all as specified and as directed.
M&L for plain cement concrete 1:3:6 type C-1 using 20mm grade stone aggregate as in coping, kneers, appx stone, inlcuding weathering slightly rounded or chamfered aganles and throating in cement mortar 1:4 ,complete all as specified and directed.
Sch 'A' Part-II (E/M works) M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC conduit medium grade of 25mm width complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 88 above but for one 6 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
M&L for Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Supply and fixing in replacement Lamp holder insulated body PVC/ Polycabonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 09 watt complete all as specified and directed.
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete all as specified and directed.
S&F for exhaust fan of 300mm sweep, heavy duty, 900 RPM electrical operated 230 Volts AC single phase with metal body with all accessories and louver tec complete all as specified and directed.
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electricity operated suitable for 230 volts, 50 hz, AC supply system complete with porcelen/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 25 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
M&L for sheet metal enclosure MCB distribution board, single door single pole and neutral with IP-66 protection single phase 240 volts 2 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB single pole & neutral 240 volts any rating from 40 amps conforming to IS 8828 to 1996, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB single pole, 240 volts any rating from 5 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Supply, Laying, connecting and testing in replacement of service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular after taking down old unserviceable cable including others accessories complete all as specified and directed.
S&F for LED street light fitting 25 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed
M&L for GI bracket pipe of size 40mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clams 2 Nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts and washers complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
S&F for 25 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors, complete all as specified and directed.
M&L for cutting, threading and inserting tee for taking new branch connection from existing pipe line of any size for the pipe size 25mm , complete all as specified and directed by Engr-in-Charge.
M&L for 25mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes complete all as specified and directed.
S&F for speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR part-I and as directed. Note: punned thickness i.e. 18 cm shall be measured for payment purpose.
Supplying and laying re-inforced precast concrete cable cover, class LV, type 1 flat, of size 250mm x 150mm x 40mm complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 2 core, complete all as specified and directed.
M&L for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands including removing of overhead conductor / cable , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , including removing of overhead conductor / cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete , including removal of overhead conductor / cable , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete , including removal of overhead conductor / cable , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete , including removal of overhead conductor / cable , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete , including removal of overhead conductor / cable , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete , including removal of overhead conductor / cable , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
S&F for LED street light fitting 35 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lenses with IP 65, complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 Sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type ,complete all as specified and directed
S&F for steel tubular swaged poles errected to truly vertical position with 6mm thick mild steel base plate of size 300mm x300mm, welded to Pole, B-118 finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II, type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide at 300mm spacing alternately and marking pole number. with black paint at suitable height including taking down old unserviceable broken steel pole of 9 mtr long complete all as specified and directed. (Note :- Necessary excavation of earth work, removing, returning filling in, PCC foundations of poles, coping etc shall be measured and paid separately)
S&F for rigid non-metallic PVC conduit 25mm bore medium grade inclduing conduit accessries for encasing the cable from looping box to street light fittings on poles /on wsall surface as per site requirement with necessary base saddles all as specified and directed.
S&F for GI brackest pipe of size 25mm dia medium grade of 1.2 m long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall/pole surface by providing suitable MS iron 25x4mm clamps 2 Nos of lenths as requried at site to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts & washers and removing of old unserviceable item complete all as specified and directed.
S&F for FRP looping / junction box of size 300x200x105mm with connector and comprising of MCB SP 6 Amps, ISI marked, 240V complete with and including providing GI clamps, nuts bolts etc suitable for fixing on wall / steel tubular pole etc and including removing unserviceable item, complete all as specified and directed.
S&F for copper conductor cable, PVC insulated, sheathed, flexible, multistranded, ISI marked, 1100 Volts grade, 3 core 1.5 Sqmm and including connection and testing including removing old unserviceable item complete all as specified and directed
S&F for LED flood lights of 120 watt , 230 V AC outdoor type thermal management in multiple optics and equipped with IP-66 protection ,with impact and corrosion resistant complete driver and lamp complete necessary fixing arrangements at any height and including removing old unserviceable light all as required at site or complete all as specified and directed.
M&L for cable route indicator LT type made of metal cast iron, the strip size not less than 32x4 mm, height 300mm and round shape of dia not less than 8 cm with embossed LT welded or reveted strip and round plate each other including adequate qty of PCC 1:3:6 type C-1 20mm graded agregates, complete all as specified and directed.
M&L for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
Supply, insallation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz Indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement. The minimum depth height width of panel is 450x1800x1500 mm respectively, minimum claerance from ground level is 450 mm including removing old unserviceable item complete all as specified and directed and comprising of following :- (a) MCCB, 250 Amps, FP, 35 KA, 415 volts, 50 Hz - 01 No (Adjustable type, as thermal magnetic release as in coming) (b) MCCB, 100 Amps, FP, 25 KA, 415 volts, 50 Hz - 03 Nos ((Adjustable type, as thermal magnetic release) (c) MCCB, 63 Amps, FP, 16 KA, 415 volts, 50 Hz - 04 Nos ((Adjustable type, as thermal magnetic release) (d) MCB, 40 Amps, SP, 10KA, 230 volts, 50 Hz, "C" Series - 2 Nos (e) Digital voltmeter (0-500V) with CTs and VSS-01 set, Digital Ammeter (0-100A), with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge).
Supply, insallation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz Indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement. The minimum depth height width of panel is 450x1800x1500 mm respectively, minimum claerance from ground level is 450 mm complete all as specified and directed comprising of following :- (a) MCCB, 250 Amps, FP, 35 KA, 415 volts, 50 Hz - 01 No (Adjustable type, as thermal magnetic release as in coming) (b) MCCB, 100 Amps, FP, 25 KA, 415 volts, 50 Hz - 02 Nos ((Adjustable type, as thermal magnetic release) (c) MCCB, 63 Amps, FP, 16 KA, 415 volts, 50 Hz - 02 Nos ((Adjustable type, as thermal magnetic release) (d) MCB, 40 Amps, SP, 10KA, 230 volts, 50 Hz, "C" Series - 2 Nos (e) Digital voltmeter (0-500V) with CTs and VSS-01 set, Digital Ammeter (0-100A), with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge).
M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mm c/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
BAKSHI DEVI DASS AND SONS
M/S Darshan Kumar
M/S Jasbir Singh
SUBASH CHANDER SHARMA AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .