Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.3 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹45.7 L+₹6.3 L (16.1%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹48.9 L+₹9.6 L (24.3%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹49.9 L+₹10.5 L (26.7%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹51.3 L+₹12.0 L (30.3%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
18 Sept 2023, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
REPAIR AND REPLACEMENT OF INTERNAL ELECTRICAL FITTINGS, FIXTURES, DBS AND SUB MAIN WIRING AT A, B, C, D, E SECTOR, 35 RMA, OFFICERS INSTITUTE, TS DOLHPIN AND CERTAIN MISC/TECHNICAL BUILDINGS AT DOLPHIN HILL AREA, MMT (E) AND SHO (V) UNDER
2023_MES_616088_1
C/8237/23-24/E8 / Token 75 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹99,800
Yes
5 Apr 2024
28 Aug 2023
20 Sept 2023
28 Aug 2023
18 Sept 2023
11 Sept 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc except light fitting. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers any capacityincluding all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
All as per item No. 03 above but for One light point controlled by two Nos two way switch complete ditto
All as per item No. 03 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 03 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 03 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 08 above but for One light point controlled by two Nos two way switch complete ditto
All as per item No. 08 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 08 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 08 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F repairs of single core 2.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 4 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F Single phase sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, C-curve complete all as specified and as directed. (Make: Havell's Cat No. DHDMCSN0251020 or equivelant of make as per List of Manufacturer's)
S & F in repairs AC Plug for two pin and earth plug and socket enclosure complete all as specified and as directed.
S & F in repairs AC Socket for two pin and earth plug and socket enclosure complete all as specified and as directed.
S & F in repairs 3 pin male top plug, 5 Amps for electrical fittings complete all as specified and as directed.
S & F in repairs 3 pin male top plug, 15 Amps for electrical fittings complete all as specified and as directed.
S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDNTHCDRW04 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, TPN 8 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDMTHODDW08 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW12 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repair MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB, TPN 6-32 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed (Make : Havell's Cat part No. DHMGCTNF006-032 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing in repair MCB, TPN 6-32 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed (Make : Havell's Cat part No. DHMGCTNF006-032 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing MCB, TPN 63 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed (Make : Havell's Cat part No. DHMGCTNF063 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing in repair MCB, TPN 63 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed (Make : Havell's Cat part No. DHMGCTNF063 or equivelant of make as perList of manufacturer's)
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
Supply and fix in repair fan capacitors of 2.5 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole two way 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 16 amp 240 volts, complete all as specified and as directed.
S & F in repairs bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
S & F in repairs Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts, universal with PVC rectangluar gang box complete all as specified and directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal with PVC rectangluar gang box complete all as specified and as directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed.
S & F in repairs switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F in repairs switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs modular bell push 6 amp 240 volts1 module,complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F in repairs stepped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 1 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 2 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 3 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 4 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 6 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 8 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 12 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 1/2 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 3 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 4 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 6 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 8 module complete all as specified and as directed.
S & F in repair 1/2 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 3 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 4 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 6 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repair 8 Module surface mounting plastic box including white cover plate with frame complete all as specified and as directed.
S & F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S & F in repairs LED Drive 36/40 watts as per site requirement complete all as specified and as directed.
S & F in repairs LED Drive 12-15 watts as per site requirement complete all as specified and as directed
S & F in repairs LED Drive 18-24 watts as per site requirement complete all as specified and as directed
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 10 Watt, Lumen ≥ 1000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Jaquar Cat No. LGLZ01X010XC or equivelant of make as per list of manufacturer)
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 20 Watt, Lumen ≥ 2000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Jaquar Cat No. LKBS01S020X or equivelant of make as per list of manufacturer)
S & F in repairs LED light fittings, ceiling mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 2'x2', 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LULTSLS036XC or equivelant of make as per list of manufacturer)
S & F in repairs LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI > 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LBLK02X010XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R012XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 15 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R015XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Surface mounted round, die cast aluminium housing, 12 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNRO02R012SC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Surface mounted round/square, die cast aluminium housing, 15 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNRP02R015SC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 18 Watt as per the existing cutout, 200-275mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R018XC or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 24 Watt as per the existing cutout, 200-275mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LNEP01R024XC or equivelant of make as per list of manufacturer)
S & F in repair 7 Watt, LED picture light fittings, having 270 Lumen and 3000K, correlated colour temperture, decorating light with all accessories, internally pre-wired and connecting up complete all as specified and directed. (Make : Phillips Model No. Muziris 31402 or equivelant model of make as specified in list of manufacturer).
S & F in repairs LED Bulb, 5 Watts, B-22 Lumen ≥ 500, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
S & F in repairs LED Bulb, 9 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specified and directed.
S & F in repair LED Strip light, 24V DC, 25W, 8mm width with IP 20 protection, uniform light distribution and long lasting adhesive and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. (Make: Jaquar Cat No. LSTP03X005XW or equivelant of make as per list of manufacturer)
S & F in repairs LED Power Supply for IP20 strip light, 24V DC, 30 Watt suitable for strip lights and connecting up complete all as specified and directed. (Make: Jaquar Cat No. LDRV01S030XX or equivelant of make as per list of manufacturer)
S & F in repairs LED tube rod, T8, 20 Watt, polycarbonate diffuser, 1200mm length, CCT: WW/CW complete all as specified and directed. (Make: Jaquar Cat No. LTBL01X010XC or equivelant of make as per list of manufacturer)
S & F in repairs LED light fittings, Ceiling mounted, panel type, white powder coated CRCA body, PC lens, Approx dimensions 1'x4', 33 Watt, Lumen ≥ 3300, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LULU4SL033XC or equivelant of make as per list of manufacturer)
S & F in repairs 200 Watt vertical suspended high bay light fitting, pressure die cast aluminium housing wekk glass luminaries with high power LED as light source complete and including proper fixing arrangement with suitable clamp, nuts, screw etc and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. LHBLD1S200XC or equivelant of make as per list of manufacturer)
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 6"x4" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 10"x8" for fixing switches, sockets & regulator etc complete all as specified and as directed.
M & L for complete checking of LT panel board installed at various locations of MD ACCN block, checking of electrical connections such as thimbles, spring nuts, rubber gasket, window glass cover and refixed the same properly in position including replacement of such minor items (if any) as required at site complete all as directed by the Engr-in-Charge.
Material and Labour for preparation of old metal surfaces of Panel Boards after complete removal of existing painting over 10cm width or girth not otherwise described and applying two coats of enamel paint (1st quality) of simens grey colour over a coat red oxide zinc chrome primer and marking the Qtr No, Panel Board No in front side complete all as specified and directed by engineer in Charge. (Note: Adjoing areas there to properly covered befor painting. Adjoing areas, floor, walls are to cleaned free of paint spillage after painting work. If Paint spill is not cleaned to match with exsting surface a panel recovery @ Rs.200/- per location will be made from payments due to the contractor).
S & F in repairs Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed. (Note for item Nos 54 to 77: Makes and Models of fittings/fixtures under these items shall be as per the existing makes & Models as per the site requirement and as directed by the Engr-in-Charge)
P Govinda Reddy Infrastructure
JAHNAVI ASSOCIATES
VARADHI ENTERPRISES
SHIRIDI SAI BUILDERS
LALITHA SAI INFRA
SREE DURGA INFOTECH
ESWAR ENTERPRISES
DHEERU BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .