Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.5 Cr
EMD Value
₹3.1 L
Closing Date
15 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Division Awantipora
Executive Engineer RNB Division Awantipora
Construction of building for Tehsil Library, Tral.
2025_PWDJK_296216_1
128/EEA/RNB of 2025-26/7059-69 Dated 24-11-2025
Open Tender
Civil Works
Percentage
365 days
tral
AS PER NIT
5 documents required · 5 mandatory
₹2,600
Executive Engineer RNB Division Awantipora
₹3.1 L
24 Nov 2025
24 Nov 2025
16 Dec 2025
24 Nov 2025
15 Dec 2025
25 Nov 2025
Construction of Tehsil Library.
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:
Providing and laying of stone soling hand packed and compacted with hand roller including carriage complete.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasterners shall be paid for seperately): Second class kail wood Including carriage of all materials involved with loading unloading and stacking complete.
Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering 1:2:4 mix (1 Cement: 2 coarse sand: 4 graded Crushed Stone aggregate 20mm nominal size).All work upto plinth level
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and fixing of Hardware fittings (Brass) as per approved samples & standard make i/c all fittings and fixtures complete.
Centering and shuttering including strutting, propping etc. and removal of form work for lintel beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platforms.
Centering and shuttering including strutting, propping etc. and removal of form work for Stairs (excluding landings) except spiral staircases.
Centering and shuttering including strutting, propping etc. and removal of form work for Edges of slabs and breaks in floors and wallsUnder 20 cm wide
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming & watering lead upto 50mtrs and lift upto 1.5m.
Centering and shuttering including strutting, propping etc. and removal of form work for foundation footings, bases of columns etc for mass concrete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete above plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more.
Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer with all carriages etc. complete.
Providing and fixing Hi-rib Colour Coated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(0.50 mm thickness )
stone aggregate avg lead 13km
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) in 2nd class kail wood
Providing and fixing 35 mm panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge in 2nd class kail wood
Painting with synthetic enamel paint ( one or
Estimated Rate without GST in Rs. P
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering 1:2:4 mix (1 Cement: 2 coarse sand: 4 graded Crushed Stone aggregate 20mm nominal size).All work upto plinth level
Providing and fixing Colour coated galvanized of width 60 cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. (0.50 mm thick with zinc coating not less than 275 gram/m2) (For ridges or hips/Vallyes )
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) complete including all necessary scaffolding etc.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, incl. pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete, 600x600 mm
Providing and laying Vitrtified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
more coats on New work) of approved brand and manufacturer to give an even shade New work.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class Kail wood
Providing and fixing of following size of PVC Fitting ISI Marked
A) 100mm dia Door Tee
B) 100mm dia Plain Bend
C) 100mm dia Collar.
D) 100mm dia P-Trap
E) 100mm Door Bend
F) 100mm dia Plain Tee
G) 100mm PVC Prince Cliff
H) 75mm dia Door Bend
I) 75mm dia Door Tee
J) 75mm dia Plain Bend
K) 75mm dia Collar.
L) 75mm dia Floor Trap.
M) 75mm dia Plain Tee
N) 75mm PVC Prince Cliff
O) 75mm dia PVC Cowel Caps
P) 50mm dia PVC Elbow
Q) 50mm dia PVC Tee
Providing and fixing of 300 mm x 40 mm thick 2nd class kail wood eaves boarding incl cost of nails etc complete job
Providing and fixing of following size of PVC Pipe of approved brand and standard quality (B-Type) including specified adhesive.
12mm thick cement plaster of mix 1:6 (1 cement :6 fine sand),
B) 75mm dia
A) 100mm dia
A) 20mm dia
B) 25mm dia
Supply, installation, testing and commissioning of gunmetal, male or female threaded isolation control valve (Ball Valve), of approved quality confirming to IS 778, PN 10, with necessary specials, unions, nipple etc., to complete the job.
A) 20mm dia
B) 25mm dia
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing of CP Health Faucet 900 mm long complete of standard make.
C) 50mm dia
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-inchargeb.
Providing/fixing of CP Bib cock (2 in 1) of approved make .
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Providing and fixing 15 mm nominal bore C.P. brass bib cock ofapproved quality conforming to IS : 8931
Providing & Fixing C.P. Single hole Mixer of approved qualityfor wash basin of approved make including cutting and making good the walls wherever required.
Providing & Fixing 15 mm dia C.P Wall mixer of approved quality (Non telephonic) of standard design and of approved make complete including C.P. wall flange, cutting and making good the walls wherever required.
Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and fixing CP waste Coupling of approved make.
Providing and fixing of CP Grating with Anti Cockroach trap below the grating hinge type.
Providing and fixing PVC Waste pipe of approved make
Providing and fixing of 6" geyser bolts of approved make
Providing and fixing 15mm dia 2"- 3" long CP nipples approved make
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets ofthe same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Construction of Brick masonry manholes using 2nd class bricks in 1:6 mix including plastering /CI frame with cover, Complete Job of following sizes.(for library,septic tank and soakage pit)
Providing and fixing PVC connection pipe upto 24" long. Approved make.
Providing , installation, commissioning and testing Hot water Geyser of 35 Ltr Capacity of approved make (Venus, Racold, Jaguar or equivalent) including fixing with bolts and making necessary connections.
Carriage of materials by mechanical Transport
sand for an avg lead 13 Kms
Bricks for an avg lead 24 Kms
Stone aggeregate avg. lead 13km
Septic tank and Soakage pit
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of soil :
Providing and laying Stone solling including compacting, watering including all carriages of material complete. Inc carraige with avg lead of 15 kms
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing 0.6 H.P. Motor/ Pump of (ISI Mark) Reservoir tanks to over head tanks incl power supply & MCB for control etc complete.
Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting propping etc. removal of form work in Suspended floors, roofs, landings, balconies and access platforms
Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.40mm thick with 20 mm nominal size stone aggregate.
Centering and shuttering including strutting propping etc. removal of form work Under 20 cm wide in Edge of Slabs
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in In cement mortar 1 cement: 6 fine sand mortar. I
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: 7.1.1 Cement mortar 1:6 (1 Cement : 6 coarse sand)
Carriage of materials by mechanical Transport
12 mm thk cement plaster in sand mortar 1:6 mix (1 cement:6 course sand)
stones for an average lead of 13kms.
Dry random rubble masonry with hard stone in foundation and plinth with bound stone using quarry stone.
stone agg.for an avg lead 13 Kms
Construction of Chowkidar's Quarter.
Sand avg. lead 13 km
Supply and filling of dry stone soling maximum size 100 - 75mm duly hand packed including all carriages, leads and lifts up to site of work complete.
Bricks avg. lead 24km
Earth work in
excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting propping ete and removal of form work for Suspended floors, roofs, landings, balconies and access platforms.
Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. includingwelding ,grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). .
Providing and fixing 40x5mm flat iron hold fasts 40cm long including fixing to frame with 10mm dia bolts, nuts and wooden plugs and embedding in cement concrete 1:3:6 blocks, 20mm size of aggregate.
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
12 mm thick cement plaster of 1:4 mix (1 cement : 4 find sand mortar)
Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc. for mass concrete.
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
15mm plaster in1:6(1 cement : 6 fine sand mortar)
Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard or soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on wood / steel works.
Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
TOTAL AMOUNT Without GST in Rs. P
Applying one coat of cement primer of approved brand and manufacture on wall surface. (cement primer)
Providing & fixing of glass panes 4mm thick @10kg/sqm for windows shutters. With 0.5" ornamental kail wood beading bedded in putty and fixed with nails.
Providing electrification including wiring conduits MCBs connction complete job inc p/f of 12 watts LED lights, 1200mm ceiling fan, 1200 mm exhauts fan in 3x4 sqmm pvc insulated multithreaded copper wire with p/f of 16 amp switch-socket with MCB.The lighting points include providing and fixing complete job.
Providing corrugated GS sheet roofing fixied with polymer coated J or L hooks, bolts and nuts 8mm diamter with bitumen and G I limpet washers or with GI limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlaping sheets complete (Upto a ptich of 60 degrees) excluding the cost of purlins rafters and trusses. (0.63 mm thick with zinc coating not less than 272 gm/sqm)
Providing ridges or hips of width 60mm overall width plain GS sheets fixed with polymer coated J or L hooks bolts and nuts 8mm dia GI limpet and bitumen washers complete
Providing valleys of 90cm wide overall in plains GS sheets fixed with polymer coated J or L hooks bolts and nuts 8mm dia GI limpet and bitumen washers complete (1.60mm thick with zinc coating not less than 350gm/sqm)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade with two or more coats over and including priming coat with cement primer.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete 50 mm thick with 20mm nominal size stone aggregate
Supply and installation of satin finish stainless steel AISI 304 stainless steel Posts having 100mm dia tube, erected with chemical grout to be fixed on the top of slab/skirting (Spigot Fixed) at corners complete, as manufactured by Dline or approved equivalent & shall be fixed above the finished level complete as per architectural drawings.
100mm Handle
125 mm Handle
100mm Tower bolt
150mm Tower bolts
stay hooks
L-drops 12"
Providing and fixing of following size of PVC (Prince make) Fitting ISI Marked
A) 100mm dia Door Tee
B) 100mm dia Plain Bend
C) 100mm dia Collar.
D) 100mm dia P-Trap
E) 100mm Door Bend
F) 100mm dia Plain Tee
G) 100mm PVC Prince Cliff
H) 75mm dia Door Bend
I) 75mm dia Door Tee
J) 75mm dia Plain Bend
K) 75mm dia Collar.
L) 75mm dia Floor Trap.
M) 75mm dia Plain Tee
N) 75mm PVC Prince Cliff
O) 75mm dia PVC Cowel Caps
P) 50mm dia PVC Elbow
Q) 50mm dia PVC Tee
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.2nd class Kail Wood.
Providing and fixing plained eaves boarding.250x32 mm (nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Providing and fixing of following size of PVC of approved make B type.
Providing, laying and fixing heavy duty Glass Fibre reinforced PPR (Polypropylene Random- Copolymer) pipes & Fittings of approved quality with solvent weld socket joints and necessary (female Elbow fittings brass thread) such as sockets, back nuts, elbows, bends, tees, reducers, enlargers, plugs, clamps, Transition Bushing, unions etc. including necessary excavation, backfilling, fixing with clamps, drilling holes in walls, slabs & making the surface good with hydraulic testing complete job.
A) 20mm dia
B) 25mm dia
Supply, installation, testing and commissioning of gunmetal, male or female threaded isolation control valve (Ball Valve), of approved quality confirming to IS 778, PN 10, with necessary specials, unions, nipple etc., to complete the job.
A) 20mm dia
B) 25mm dia
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing of CP Health Faucet 900 mm long complete of standard make.
Providing and fixing CP 2 in 1 Bib Cock heavy (Standard make)
A) 100mm dia
Providing and fixing CP short body Bib Cock heavy (Standard make)
Providing and fixing CP long body Bib Cock heavy (Standard make)
Providing and fixing CP Angle valve (Standard make)
Providing & Fixing 15 mm dia C.P Wall mixer of approved quality (Non telephonic) of standard design and of approved make complete including C.P. wall flange, cutting and making good the walls wherever required.
Providing and fixing CP waste Coupling
Providing and fixing PVC Waste pipe
Providing and fixing of 6" geyser bolts of standard make
Providing and fixing of CP Grating with Anti Cockroach trap below the grating hinge type.
B) 75mm dia
Providing and fixing looking Mirror (Belgium Type)
Providing and fixing CP Soap case.
Providing and fixing PVC connection pipe upto 24" long.
Construction of Brick masonry manholes using 2nd class bricks in 1:6 mix including plastering /CI frame with cover, Complete Job of following sizes.(for library,septic tank and soakage pit)
Providing and fixing 0.6 H.P. Motor/ Pump from Reservoir tanks to over head tanks of standard make complete job incl power supply & MCB for control.
Providing , installation, commissioning and testing Hot water Geyser of 35 Ltr Capacity of approved make (Venus, Racold, Jaguar or equivalent) including fixing with bolts and making necessary connections.
Carriage of materials by mechanical transport including loading, unloading and stacking up to the site of work complete.
C) 50mm dia
Sand avg lead 13 Kms
Bricks avg lead 24 Kms
Providing and fixing 15mm dia 2"- 3" long CP nipples of approved make.
A. Heating points
B. Lighting Points
A. 12 watt surface lights
B. 1200 mm ceiling fans
C. 200 mm exhaut fan
D. 6-10 amp S pole MCB
E. 40 amp d pole MCB
Electrification.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/eq. standard make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit, with modular switch ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.), modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (To be monitored and checked by the concerned Electrical Division)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.(To be monitored and checked by the concerned Electrical Division)
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit.(To be monitored and checked by the concerned Electrical Division)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Leiva /ABB Tvisha make make.)(To be monitored and checked by the concerned Electrical Division)
Wiring for lighting circuits/ 6- 10 amp power plugwith 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(To be monitored and checked by the concerned Electrical Division)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.)(To be monitored and checked by the concerned Electrical Division)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (To b
e monitored and checked by the concerned Electrical Division)
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, "C" curve including connections, painting etc. as required.(To be monitored and checked by the concerned Electrical Division)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/ equivalent as directed by engineer incharge.), single core cable in surface/ recessed medium class PVC conduit as required.(To be monitored and checked by the concerned Electrical Division)
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
c) space for 24 way MCB's
( d )2 X 10 sq. mm + 1 X 6 sq. mm earth wire ( Lighting submain/ three phase points)
Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete(To be monitored and checked by the concerned Electrical Division)
Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends.(To be monitored and checked by the concerned Electrical Division)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(To be monitored and checked by the concerned Electrical Division)
Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.) (To be monitored and checked by the concerned Electrical Division)
Supply installation testing and commissioning of AC/DC Bell including Bell push and battries GM/ standard make
Sub Head-2 - Fixtures and Fittings
Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium body ,Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trilux/Wipro make / sample to be approved before installation.. (To be monitored and checked by the concerned Electrical Division)
S/F testing and comm. Of 20 Watt 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with THD<10%.( commercial series) Philips / Trulux/ wipro make/ eq. standard make as directed by engineer incharge. (To be monitored and checked by the concerned Electrical Division)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, decorative ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA /Havells /Crompton/equivalent make as directed by engineer incharge, ( sample to be approved before installation) (To be monitored and checked by the concerned Electrical Division)
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tivsha/schneider Livia /Havell Coral make.(To be monitored and checked by the concerned Electrical Division)
Supply installation testing and comm. Of 250mm -300mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.(To be monitored and checked by the concerned Electrical Division)
Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)(To be monitored and checked by the concerned Electrical Division)
6 way (4 + 18), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)(To be monitored and checked by the concerned Electrical Division)
2 + 12 way, Double door
S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABB ./equivalent make as directed by engineer incharge.(To be monitored and checked by the concerned Electrical Division)
a) 6-32 Amp SP MCB
b) 40-63amp DP MCB
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by8- 10 SWG G.I wire with 1/2" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.(To be monitored and checked by the concerned Electrical Division)
S/L , testing and commissioning of PVC XLPE insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. (To be monitored and checked by the concerned Electrical Division)
a)50 sq.mm 3.5 core
Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) (To be monitored and checked by the concerned Electrical Division)
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
Normal INCOMING:
a)160A 4P MCCB 25 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.
b) 4 No. of Aluminium Bus Bar of 300 Amp.
c)Digital meters and phase indicators -1 set.
d) onload Change over switch 100 Amp for generator.Front operated.
b) 4 No. of Aluminium Bus Bar of 300 Amp.
e) 4 No. of Aluminium Bus Bar of 200 Amp.
Inverter Incommer
(a) 100 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.
b) 4 No. of Aluminium Bus Bar of 300 Amp.
(b) 200 Amp 2 strip bus bar
OUTGOING:
c) 40-63amp DP MCB
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the walls wherever required :White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_959535.xls
BOQ • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .