Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC 3 5557 A SIVARAM TOWER MATTANNUR 670702 KERALA | KANNUR | KERALA | 670702 | L1 | Accepted-AOC L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
16 Apr 2022, 6:00 pmClosed
Executive Engineer
PWD Electrical Division Kannur 2
REBUILD Kerala Initiative Renovation of Collectorate Kannur Improvements to the Electrical Installation General Electrical WorK
2022_PWD_484352_2
ELD/TN/14/21-22
Open Tender
Electrical Works
Item Rate
120 days
Kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
2 Sept 2022
7 Apr 2022
20 Apr 2022
7 Apr 2022
16 Apr 2022
7 Apr 2022
Amount
SITC OF OUTDOOR USS
OD110455/2021-2022:Supply, conveyance, installation, testing and commissioning of 160 kVA OUTDOOR type unitized substation comprising of H.T.panel trunked with cast resin Transformer with load break switch/ Air break switch on H.T.side and manually operated, with top/bottom entry cable box, 250A, 4 pole 36kA MCCB on L.T. side as per technical details furnished below. H.T. Portion consists of (1) 1 No 11K.V, 630A, 350M.V.A Air break/Load break switch suitable for 3 phase,3 wire,50 Hz system with suitable H.R.C. fuses of appropriate rating with earth inter lock with main switch and mechanical ON/OFF indication,(2)shunt trip coil for the remote operation of the load break switch . Transformer Portion consists of 160 kVA , 11 K.V, 50 Hz, Delta/Star connected cast resin insulated copper wound transformer. The core shall be made of laser scribed core, Class 'F' insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achieve tap position of +2.5% 2levels &- 2.5% x 4 levels. The transformer shall confirm to IS.726 and IS11171 /1985 reaffirmed in 1991. LT Portion consists of:- The LT portion shall be provided with 1No 4Pole 250A 50 hz 36KA type MCCB with setting range 80-100% and 3OC and 1EF release accessories with rotary handle and provision for LT Side CT type Energy meter for audit All inter connection from HT load break switch to transformer and to LT breaker shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the point of contacts. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The enclosure shall be mechanical and earthing interlocks.The enclosure shall comply to IP54 or higher standards for OUTDOOR installation and shall be powder coated over suitable primer after seven tank processing. The USS shall be installed as per the directions at site. Transformer shall conform to IS 11171/1985.The load tests and standard tests shall be conducted at factory prior to delivery and shall be witnessed by the department engineer. Operation maintenance manual, control wiring documents etc shall be submitted. The OUTDOOR USS shall have a warranty of 36 months from date of commissioning.
OD108810/2021-2022:Supply & laying of one number 11 KV grade XLPE cable of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3 core 300 sq mm
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
14.13.3:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia
90.12.5.35:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 240 sq mm
90.12.7.35:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm
90.12.10.10:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation160/135 mm or nearest size
90.12.12.13:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation200/174 mm or nearest size
10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
OD108961/2021-2022:Supply and providing plate earthing with 1200x1200x12 mm GI/CI earth plate, 50mm GI watering pipe, GI funnel with weld mesh, 25 x 3mm GI clamps, charcoal etc., including providing brick work masonry enclosure at the top (450 x 450 x 450 mm inside) but excluding earth continuity conductor, test joint and covering at the top
OD108959/2021-2022:Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
OD108963/2021-2022:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm tinned copper strip
OD108962/2021-2022:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 x 3 mm Copper strip
OD108999/2021-2022:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required a) 25x3mm brass bolt with hexagonal/square head, nut and washer
OD109000/2021-2022:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required a) 25x6mm brass bolt with hexagonal/square head, nut and washer
4.1.4:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.2.4:Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.17:Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.19:Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD109859/2021-2022:Supply, conveyance and fixing the following types & current rated Spark gap type Surge protection device conforming to IEC 161643-11 in the existing panel assembly as required Arresting capacity 50 kA (10/350 µs) per pole (L-N) , Arresting capacity 125 kA (10/350 µs) per pole (N-PE) ,Power consumption < 26 mW/pole Protection level < 1.3 kV, Line follow current quenching 25 kA Ipeak , suitable for 235V, 50 Hz, AC supply . OBO Coordinated Lightning Controller MCD 50-B 3+1-OS 5096836 OBO BETTERMANN
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
OD109097/2021-2022:Supply & fixing the following accessories in position and giving connection. A) Copper wound block reactor transformer, 400 V, 20 KVAr suitable for filtering harmonics up to 7% THD
OD109098/2021-2022:Supply & fixing the following accessories in position and giving connection. A) Copper wound block reactor transformer, 400 V, 15 KVAr suitable for filtering harmonics up to 7% THD
OD109099/2021-2022:Supply & fixing the following accessories in position and giving connection. A) Copper wound block reactor transformer, 400 V, 10 to 12.5 KVAr suitable for filtering harmonics up to 7% THD
OD109100/2021-2022:Supply & fixing the following accessories in position and giving connection. A) Copper wound block reactor transformer, 400 V, 5 KVAr suitable for filtering harmonics up to 7% THD
90.14.24.68:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.71:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.73:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.74:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
OD109103/2021-2022:Supply and Fixing 8 stage 440 / 110 V , 5A/1A , Intelligent Power Factor Controllers (IPFC)
OD109104/2021-2022:Supply & fixing three Pole Capacitor duty contactors for switching capacitor banks 4 to 7 kVAR with AC Coil,
OD109105/2021-2022:Supply & fixing three Pole Capacitor duty contactors for switching capacitor banks 7.5 to 10 kVAR with AC Coil,
OD109106/2021-2022:Supply & fixing three Pole Capacitor duty contactors for switching capacitor banks 11 to 15 kVAR with AC Coil,
OD109107/2021-2022:Supply & fixing three Pole Capacitor duty contactors for switching capacitor banks 20 kVAR with AC Coil,
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD109127/2021-2022:Supplying and fixing 40A to 63A rating, 415 V, 10 kA, C curve, miniature circuit breaker suitable for an inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole
90.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.13:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.200A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.17:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
90.14.11.6:MCCB AccessoriesSupply and fixing 250 - 400A earth fault module of MCCB with builtin CBCT.
90.14.11.8:MCCB AccessoriesSupply and fixing CBCT suitable for 630 - 800A earth fault module.
90.14.11.11:MCCB AccessoriesSupply and fixing one number under voltage release for all voltage range up to 630A MCCB.
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
OD109128/2021-2022:Supply and fixing the following legend plates in the panel assembly. a) Aluminium anodised legend plate of size 100 x 40 mm. with inscription of CABLE ALLEY.
OD109129/2021-2022:Supply and fixing the following legend plates in the panel assembly. a) Aluminium anodised legend plate of size 100 x 40 mm. with inscription of BUS BAR CHAMBER .
OD109130/2021-2022:Supply and fixing the following legend plates in the panel assembly. a) Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
OD109131/2021-2022:Supply and fixing LED indicators for all voltage ranges - Red, Green, Black, Yellow, Orange Colour
OD109132/2021-2022:Supply and fixing LED indicators for all voltage ranges - Blue Colour
OD109133/2021-2022:Supply & fixing 200/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
OD109134/2021-2022:Supply & fixing the following multi-function meters in the panel assembly . a) Multi function meter to read VA ,PF,KW ,KWh ,KVA,KVAr ,KVARh ,THD ,Phase angle -3ph accuracy class-0.5 LCD
OD110449/2021-2022:Supply, conveyance, installation, testing and commissioning of 150 mm, single phase, light duty cooling fan etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.
OD110450/2021-2022:Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and giving connection as required
OD110453/2021-2022:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitbable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keepi ng the wiring firm by suitable tie/tie mounts/PVC duct etc as required. 1.50 sq mm single run with required sockets.
OD110452/2021-2022:Preparation of required drawings for obtaining necessary approval from Kerala State Electrical Inspectorate. Drawings shall be in A3 sheet size in original(first preparation of page)
OD110451/2021-2022:Preparation of required drawings for obtaining necessary approval from Kerala State Electrical Inspectorate. Drawings shall be in A3 sheet size in original(for the preparation of additional copy)
Replacing of old damaged fluorescent fittings and EI
OD109138/2021-2022:Supply Conveyance installation testing and commissioning of pre-wired fluorescent fittings of all types complete with all accessories and fluorescent lamps etc. directly on wall or ceiling with Suitable size PVC round block neatly painted to suit the fitting and giving connection with required length of 3 core 1.5 sq mm copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections as required. a) Round type LED Light fittings on recess/surface having light out put not less than 100lum/watt.(Make: Philips GreenLED Ultima Round DN091B LED6S-6500 PSU WH or its equivalent)
OD109139/2021-2022:Supply Conveyance installation testing and commissioning of pre-wired fluorescent fittings of all types complete with all accessories and fluorescent lamps etc. directly on wall or ceiling with Suitable size PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections as required. a) 1X1 feet LED Light fittings on recess/surface having light out put not less than 100lum/watt.(Make: Philips GreenLED Ultima Square DN096B LED6S-6500 PSU WH or its equivalent)
OD109140/2021-2022:Supply Conveyance installation testing and commissioning of pre-wired fluorescent fittings of all types complete with all accessories and fluorescent lamps etc. directly on wall or ceiling with Suitable size PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections as required. a) 2X2 feet LED Light fittings on recess/surface having light out put not less than 100lum/watt.(Make: Philips FullGlow G5 RC380B LED25S-6500 G5 L60W60 PSU OD or its equivalent)
OD109141/2021-2022:Supply Conveyance, installation, testing and commissioning of pre-wired light fitting of all types complete with all accessories and fluorescent lamps etc. fixing on ceiling and giving connections with required length of 3 core 1.5 sq mm copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. a) 1X4 FEET LED LIGHT FITTING (Make: CROMPTON SPAN LCTLRN-40-CDL(1X4) LED recess/Surface mounting LED fitting out put not less than 100lu/watt
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.28.6:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD109137/2021-2022:Charges for dismantling the existing EI, complete, making good the damages of walls and conveying the dismantled materials to section store.
Bidder Name
SIVARAM.E
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_698175.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .