Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
12 Sept 2026, 6:00 pm
GE NORTH SECUNDERABAD
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
WELCOME MAINTENANCE INCLUDING INTERNAL WIRING FITTINGS AND FIXTURES OF CERTAIN MD AND OTM ACCN AT BOLARUM AREA UNDER AGE EM (N) OF GE (NORTH) SECUNDERABAD
2026_MES_785925_1
8091
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH SECUNDERABAD
₹90,000
Yes
22 Aug 2026
22 Aug 2026
19 Sept 2026
22 Aug 2026
12 Sept 2026
5 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling complete all as specified and directed by Eng- in- Charge. | 2,001 | Point | - | - |
| 2 | Disconnecting and removing the MCB DBs/AC Box from any height, stripping out the fitting for examine replacement of un serviceable spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning and testing complete all as specified and directed by Eng- in- Charge. | 90 | Each | - | - |
| 3 | Taking down old submain wiring of any size and type complete all as specified and directed by Eng- in- Charge. | 1,120 | RM | - | - |
| 4 | M&L Concealed point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed.
Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. (ii) The cost of cutting chases of required width and depth for concealed conduit including rendering,making good matching with existing surface of same colour painting,etc as directed by Eng-in-charge deened to be included in the unit rate quoted. | 300 | Point | - | - |
| 5 | All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . | 62 | Point | - | - |
| 6 | All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. | 44 | Point | - | - |
| 7 | All as per Item No. 4 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor Note: Modular cover plate with frame and modular metal flux box and cutting/chases included in the rate quoted. | 52 | Point | - | - |
| 8 | M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc, for one light/fan point controlled by one switch complete all as specified and directed.
Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. | 350 | Point | - | - |
| 9 | All as per Item No. 8 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . | 60 | Point | - | - |
| 10 | All as per Item No. 8 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. | 42 | Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_880698.xls
BOQ • 0.55 MB
tender8091.pdf
Tender Documents • 1.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].