Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC PANISAGAR NORTH TRIPURA PIN 799260 | PANISAGAR | NORTH TRIPURA | TRIPURA | 799260 | ₹10.4 L | L1 | Accepted-AOC Work order issued as the bidder is Technically and financially responsive |
| 2 | L2₹11.3 L+₹91,980 (8.86%)Rejected-Finance | ₹11.3 L+₹91,980 (8.86%) | L2 | Rejected-Finance Higher bid |
| 3 | L3₹11.3 L+₹92,270 (8.89%)Rejected-Finance KANCHANPUR NORTH TRIPURA PIN 799270 | KANCHANPUR | NORTH TRIPURA | TRIPURA | 799270 | ₹11.3 L+₹92,270 (8.89%) | L3 | Rejected-Finance Higher bid |
| 4 | L4₹13.8 L+₹3.4 L (32.8%)Rejected-Finance | ₹13.8 L+₹3.4 L (32.8%) | L4 | Rejected-Finance Higher bid |
Tender Value
₹14.5 L
EMD Value
₹29,016
Closing Date
24 Feb 2026, 3:00 pmClosed
The Executive Engineer PWD WR Divison No VII Pecha
The Executive Engineer PWD WR Divison No VII Pecharthal Unakoti Tripura
Urgent Maintenance of Ramgunapara North Dhanicherra Kailabari Dhanicherra Near Ex MLA Ugalcherra and Dewanbari LI Schemes under Pecharthal RD Block under WR Sub Division Kanchanpur North Tripura during the year 2025 26 SH Repairing of le
2026_CEWR_70545_1
79 EE WRD VII PTL 2025 26
Open Tender
Civil Works
Percentage
180 days
kanchanpur
As per DNIeT
4 documents required · 4 mandatory
₹1,000
₹29,016
21 May 2026
18 Feb 2026
24 Feb 2026
18 Feb 2026
24 Feb 2026
18 Feb 2026
18 Feb 2026 - 24 Feb 2026
Providing and fitting fixing of G.I hydrant suitable for PVC pipes as per standard specification complete as per direction of Engineer-in- charge (Rate excluding the cost of NTP control valve). 80 X 50 mm dia
b) 110 mm dia pvc pipe
b) 125 mm dia PN-1.6
c) 150 mm dia PN-1.6
Providing and fitting fixing of different dia rigid UPVC unequal Tee (including earth cutting & backfilling all socketted) suitable for pipes as per IS specification of working pressure 4.0 kg/sq.cm confirming to IS: 10124 (part-V) as per CPWD Specification & direction of Engineer in-charge.unequal tee a) 200 x 200 x 140 mm dia
b) 160 x 160 x 140 mm dia
c) 160 x 160 x 110 mm dia
d) 160 x 160 x 90 mm dia
e) 140 x 140 x 110 mm dia
f) 110 x 110 x 90 mm dia
b) 140 x 140 X 140 mm dia
c) 160 x 160 X 160 mm dia
d) 315 x 315 X 315 mm dia
c) 200 x 200 X 200 mm dia
b) 140x110 mm dia
c) 110x90 mm dia
Excavating trenches of required width for pipes, cables, etc.including excavation for sockets and dressing of sides ramming of bottoms , depth minimum 1.25m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavated soil as directed within a lead of 50 m as per CPWD Specification & direction of Engineer-in-charge. A) All kinds of soil. a) Pipe , cables etc. exceeding 75mm dia but not exceeding 160 mm dia .
b) Pipe , cables etc. exceeding 200 mm dia but not exceeding 315 mm dia .
Providing and laying different dia rigid UPVC pipes of working pressure 4.0 kg/sq.cm complete with necessary coupler and solvent cement as per CPWD Specification & direction of Engineer-in-Charge. a) 90 mm dia
b) 110 mm dia.
c) 140 mm dia.
c) 160 mm dia.
d) 200 mm dia.
Labour charge for repairing of leakage in existing UPVC distribution system including required earth cutting and fitting fixing of necessary coupler etc. complete and refilling the trench with available excavated earth as per direction of the Engineer-in-charge. (Payment of couplers, tees, reducers etc will be made separately) c) 315 mm dia
b) 250 mm dia to 110 mm dia
c) 90mm dia.
Providing and fittingfixing of shore manifold made with 3mm thick MS sheet of size one way 315mm dia and three way 125 mm dia made with suitable flange (all end) including coating with steel primer (tail piece if required will be paid separetely )including proper alimghment with pipeline and earth cutting, backfilling complete as per direction of Engineer-in-charge.
Providing and fixing G.I. pipes of heavy class as per I.S. 1239 with latest amendment complete with G.I. fittings i/c trenching refilling cutting and making good the walls etc. complete as per chapter 20 of CPWD specification and direction of the Engineer-in -Charge. (External work) i) 125 mm dia Nominal Bore
ii) 150 mm dia. nominal bore.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_71790.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 9.00 MB
79DNIeT.pdf
Tender Documents • 3.30 MB
BOQ_71790.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .