| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC AOC ACCEPTED | |
| 2 | L2₹21.4 L+₹1.3 L (6.36%)Rejected-AOC | L2 | Rejected-AOC AOC NOT ACCEPTED | |
| 3 | L3₹22.0 L+₹1.9 L (9.40%)Rejected-AOC VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L3 | Rejected-AOC AOC NOT ACCEPTED | |
| 4 | L4₹23.4 L+₹3.3 L (16.6%)Rejected-AOC | L4 | Rejected-AOC AOC NOT ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹39,740
Closing Date
15 Feb 2021, 6:00 pmClosed
GE RAMGARH CANTT
GE RAMGARH CANTT, JHARKHAND, PIN 829122
Special Repair for replacement of internal E M appliances Geyser ceiling fan and exhaust fan against BER items Provn of Desert Coolers for PERS COOK HOUSE TPS Cook House and PERS Line QTY 40 at MH Provn of MINOR WORK of 1 by 2.0 Ton Split AC for se
2021_MES_413128_1
8300/3010/E8
Open Tender
Civil Works
Item Rate
120 days
GE RAMGARH
Class E Cat b i
7 documents required · 7 mandatory
₹500
Yes
GE RAMGARH CANTT
₹39,740
Yes
8 Mar 2021
16 Jan 2021
17 Feb 2021
16 Jan 2021
15 Feb 2021
1 Feb 2021
Amount
S & F ceiling fan single phase 230 V, of 1400 mm sweep including connecting up with 3 core multi-stranded copper conductor cable of size 23/0.193 from Ceiling rose to fan, along with 2-3 feet down rod suitable for ceiling fan, complete all as specified and as directed. Make Crompton Greaves/Bajaj/Havells or its equivalent as approved.
S & F exhaust fan AC single phase 230/240 Volt, 300 mm sweep with louver, complete all as specified and as directed. Make: Crompton Greaves/Bajaj/Havells or its equivalent as approved.
S & F Water Heater Storage type, electric, capacity of 25 litres, BEE 5 Star rated, white colour, rated power 2 KW, complete all as directed. Make: Havells, Cat Part No. GHWAMGTWH025, or its equivalent as per lits of approved make.
S & F Desert Cooler of dimension not less than 60cm x 60 cm x 80 cm height, thickness of PGI sheet 0.8 mm for panel and 1.0mm thick for sump, electric driven (single phase), consist of air cooling fan not less than 380 mm sweep, 230 Volts, three speed (Make: KHAITAN/POLAR or its equivalent), submersible water pump with other accessories having nominal air flow capacity of minimum 6000 cum per hour, steel body with MS frame, complete all as specified and as directed.
M & L for desert cooler's stand made of mild steel and flat iron as per size mentioned in item No.4 here-in-before, complete all as specified and as directed.
M & L, for earthing for Desert cooler and AC split type, complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. Note : Earth test result should not less than one ohm. (4+1)
S & F Air cooled split unit air conditioner electric driven single phase of capacity 2 TR, BEE 5 star rated, cooling and heating facility, complete all as specified and as directed. Make: BLUESTAR/HITACHI/AIRCON or its equivalent as approved.
S & F Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilizer at 230 V with accuracy of ± 2.5 % and of capacity 2.0 KVA, complete all as specified and as directed. Make: V GUARD/AE/APLAB or its equivalent as approved
M & L for sub main wiring with two single core 6.0 Sqmm PVC insulated unsheathed FRLS multistranded copper conductor cable and one run of 4.0 Sqmm PVC insulated unsheathed FRLS multistranded copper conductor cable for earth wire drawn in PVC concealed conduit and including making good disturbed surface wall Note :- 2 runs of 6.0 Sqmm cable and one run of earth wire 4.0 Sqmm shall be measured as one unit length.
S & F double pole and earth enclosure with a three pin and earth plug with socket, complete with one double pole MCB 20 Amp, complete all as specified and as directed.
Supply and laying and testing and commissioning LT underground cable 1100 volts grade, XLPE insulated, armoured heavy duty electric cable with multistranded aluminium conductor laid in trenches/ducts on poles etc, of cross sectional area 50Sq mm, 2 core, 1100 volts grade, complete all as specified and as directed.
M & L for submain wiring with two single core 10.0 sqmm PVC insulated FRLS multistranded copper conductor cable and one run of 6.0 Sqmm PVC unsulated unsheathed FRLS multistranded copper conductor cable for earth wire drawn in and including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20mm dia in including taking down of existing conduit or batten complete and making good disturbed surface wall, complete all as specified and as directed. Note :- 2 runs of 10.0 Sqmm cable and one run of earth wire 6.0 Sqmm shall be measured as one unit length.
S & F for sheet metal enclosures for DBs Triple pole and neutral, 4 way double door with 200 Amp rated bus bar suitable to accommodate MCB and necessary elctric cable connection through suitable lugs by crimping and making good disturbed area of wall, complete all as specified and as directed.
S & F TPN 63 Amp, 240 V, 'B' Series, 10 kA, complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for laying cable/pipes and getting out in hard/dense soil, complete all as specified and as directed.
Removing excavated materials n.exc 50 m and depositing, where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed.
Returning, filling in trenches including spreading, levelling watering and well ramming in layers n.exc 25 cm thick, complete all as specified and as directed.
M & L for reinforced precast concrete cable cover class LV, type 2, flat, size 300 mm x 180 mm x 40mm all as specified and directed
M & L clean and dry sand free from sharp material in trenches around the cable for cushioning complete (depth 23 Cm and after punning down to 18 Cm) all as specified and as directed.
M/S SHAMBHU SHARAN SINGH
M/S ROHIT CONSTUCTION
M/S Kunwar Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .