Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.9 LAccepted-AOC SATYADEV RESIDENCY MIG 275 4TH FLOOR FLAT NO 1 BEHIND ABHAYA ANJANEYA SWAMY TEMPLE NORTH EXTENSION SEETHAMADHARA VISAKHAP 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹23.5 L+₹94,330 (4.19%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | SRIKAKULAM | ANDHRA PRADESH | 532001 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹26.1 L+₹3.6 L (15.9%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹28.9 L+₹6.4 L (28.3%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹29.0 L+₹6.5 L (28.7%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
DAY TO DAY MAINTENANCE TO NIVEDITA OFFICERS ACCN, SAILORS IN-LIVING ACCN, MESS AND HOSPITAL BUILDINGS AT INHS KALYANI, SHO NCS UNDER AGE B/R-II OF GE (NB) VISAKHAPATNAM
2023_MES_593294_1
C/8177/23-24/E8 / Token 28 of 2023-24
Open Tender
Civil Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹90,000
Yes
14 Aug 2023
4 May 2023
3 Jun 2023
4 May 2023
1 Jun 2023
18 May 2023
Amount
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish outside MD land as directed by the Engr-in-Charge.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls using old size brick complete all as specified and directed.
S & F high strength corrosion resistant TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality as in half brick thick wall complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc by "Vacuum based sanding machine" and applying two coats of distemper oil emulsion over a coat of alkali resistant primer by "Auto roller" machine complete all as specified and directed.
M & L for preparation new external surfaces of wall etc "Vacuum based sanding machine" and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by "Auto Roller" machine complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed.
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, as in vertical surfaces such as skirting etc, including 10 mm thick screed bed in cement mortor 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Vitrified, designed, light shade coloured (light shade), tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Vitrified, designed, light shade coloured, tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm as in vertical surfaces such as skirting,dado, etc including 10 mm thick bedding in cement mortar 1:4 and necessary cutting of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar and removing rubbish upto a distance outside MD land complete all as directed by the Engr-in-Charge.
M & L for granite stone slab (of any type) work (table rubbed or polished) as in floor, 16 to 18 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortor 1:6 & cutting, polishing complete all as specified and directed.
M & L for granite stone slab (of any type) as in vertical surfaces such as skirting/dado etc, 16 to 18 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick screed bed in cement mortor 1:4 & cutting, polishing complete all as specified and directed.
M & L for Machine cut kota stone slab flooring 18 to 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing over and including 15 mm thick, screed bed in cement mortar 1:6 complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection/flooring etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Refixing of 15mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 26 above)
Refixing of 20mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 27 above)
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc in 'short length' complete all as specified and directed.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc in 'short length' complete all as specified and directed.
S & F in repairs, Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed
S & F in repairs float handle as per the existing specifications suitable for 10 litre capacity low level flushing cistern and making the cistern functional in all respect complete all as specified and directed.
S & F in repairs PVC syphonic kit (any type/any pattern) suitable for 10 litre capacity low level flushing cistern and making the cistern functional in all respectcomplete all as specified and directed.
S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed.
S & F in repairs, plastic water closet, Seat and Cover for pedestal pan, white / black, closed pattern with flat bottom and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S & F in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
S & F in repair 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F in repairs 40 mm dia, High density poly-ethylene pipes, (HDPE) of pressure rating 6 kgf/cm 2 laid as in waste pipe of WHB etc complete all as specified and directed.
S & F in repairs 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repairs, Brass CP mixer with 3-in-1 system for mixing hot & cold water screwed down for iron pipe, 15mm bore and fixed complete all as specified and directed
S & F in repairs, 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair 15 mm bore, angular stop valve, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs Hand Shower (Health Faucet) with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook, 15mm bore complete all as specified and directed. (Make: Jaquar Cat No. ALD-565 or equivelant of make as per List of manufacturer's)
S & F in repair 125 mm size, shower rose, brass chromium plated, swival type, complete all as specified and directed.
S & F in repairs brass spindle (heavy) suitable for bib taps/stop valve of 15mm bore all as per the existing specifications complete all as specified and directed.
S & F in repairs PVC/rubber washers suitable for bib taps/stop valve of any dia all as per the existing specifications complete all as specified and directed.
S & F in repairs, vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed.
S & F in repairs, vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed.
S & F in repairs, vitreous China wash basin, size 550 x 400mm, white, flat back including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
S & F in repairs, Vitreous China urinal, half stall type, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed.
S & F in repairs, Vitreous China bowl urinal flat back, of size 465x355x265mm, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed.
S & F in repairs, 20 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repair 25 mm bore, gun metal, globe or Gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repairs, 50 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F in repair stainless steel Coat Hook solid body of size 125mm to 175mm complete all as specified and directed.
S & F in repair brass chromium plated Coat Hook solid body of size 125mm to 175mm complete all as specified and directed.
S & F in repair 15mm bore Urinal spreader chromium plated for urinals complete all as specified and directed.
S & F in repair 15 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 142 gms) complete all as specified and directed.
S & F in repairs, 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
S & F in repairs, 25 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 455 gms) complete all as specified and directed.
S & F in repairs, 40 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 690 gms) complete all as specified and directed.
S & F in repair 40 mm dia waste coupling of PTMT (Half or full threaded ) (Minimum Weight 60 grams) complete all as specified and directed.
Complete removing the plants from the surfaces of the building with complete roots, applying recommended chemical to prevent further growth as directed, making good the disturbed surface with cement mortar 1:3 and applying the same surface finish of the existing surface and finished to match with the surrounding surfaces including removal of debris etc., out side the premises complete all as required complete all as specified and as directed.
Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) vent cowl complete all as specified and directed.
M & L for cleaning and degermination inside the RCC/PVC water storage tanks of capacity not exceeding 500 ltr of any description and in any position comprising the following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/INCHLOR-5/NB-10, TERBAC G65/INOXI-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) 1st stage: Drain out the water by using exit valve or with high capacity dewatering system or any other suitable method approved by Engr-in-Charge. (b) 2nd Stage: Cleaning all the algae formation inside the tank by using TERBAC G10/INCHLOR-5/NB-10, (a laboratory tested branded chemical) and scrubbing the walls of the tanks. (c) 3rd stage: Cleaning with fresh water by high speed jet pump with pressure of 5 PSI. (d) 4th stage Sterilization by using TERBAC G5/INCHLOR-5/NB-10, (a Laboratory certified branded halogen compound) for first bateria screening. (e) 5th stage: Cleaning the floor of the water tank by heavy duty industrial vaccum cleaner. (f) 6th stage: Sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria for 2nd bacteria screening. (g) 7th Stage: Cleaning and sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TERBAC G65/INOXI-60/NB-69 for third bacteria screening. Note:- (i) Test certificate of TERBAC G65/INOXI-60/NB-69 etc from Government Laboratory mentioning suitability for sterilization should be submitted to the Dept before using for Sterilization. (ii) Cleaning of tank shall only be carried by the authorised service provider of the material used. Necessary approval shall be obtained from GE before cleaning of the tanks, (iii) After cleaning of the tank necessary completion certificate confirming the completion of sterilization of water tank shall be issued by the service provider and a sticker shall be fixed on the tank duly mentioning the date of cleaning and name of site etc)
All as per Serial item No. 78 above but PVC tank of capapcity exc 500 and n.exc 1000 Litres complete ditto
All as per Serial item No. 78 above but PVC tank of capapcity exc 1000 and n.exc 2000 Litres complete ditto
All as per Serial item No. 78 above but for RCC overhead tanks of capapcity exc 2000 & n.exc 5000 Ltrs complete ditto
All as per Serial item No. 78 above but for RCC overhead tanks of capapcity exc 5000 & n.exc 10000 Ltrs complete ditto
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F 5000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F 2000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F in repairs, stainless steel sinks made of 1 mm thick sheet with plugs, washers and wastes including bedding in ement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F in repairs, stainless steel kitchen sinks with drainage board made of 1 mm thick sheet for kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Taking down vitreous China wash basin or sink of any size with backets and refixing in the same position after replacement of brackets as per the existing specification complete all as specified and directed.
M & L for Filling of cement mortar in sides of nahani trap, gully trap, rain water pipes out let etc. in CM 1:3 including WPC @ 2% by weight of cement or as per manufacturers instructions and making good finishes to arrest leakage / seepage complete all as specified and as directed.
Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for injecting/grouting cement slurry mixed with Conbextra EP 10 (Epoxy resinj injection grout) of M/S Fosroc Chemicals or equivalent approved Chemicals in to roof/sunken slabs of toilet by drilling holes to a depth of 60mm by 20mm dia at 1 mtr interval by mechanical means with required pressure complete all as per manufacturer's instructions and as directed
M & L for Plain cement concrete 1:5:10, type E-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. “(General Notes for all items above: (i) Contractor either himself/ themselves or depute his/their supervisor to take complaints from IVRS system during office hours i.e at 9 AM to 5 PM and completed the complaints within 24 Hours. After completion of the complaints, get it checked by JE/ Engr-in-charge to update status in IVRS system. (ii) The work has to be carried out upto G+6th floor building and the rate quoted shall deemed to be inclusive of necessary provision for this aspect accordingly)
KEERTHI ENTERPRISES
VISWAS ENGINEERING WORKS
K SATYANARAYANA ENTERPRISES
GVR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .