Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC 54 10 C JAI DEVI NAGAR MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹20.6 L+₹1.2 L (6.15%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹21.8 L+₹2.4 L (12.1%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹22.7 L+₹3.2 L (16.7%)Rejected-AOC DEHRADUN | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹23.2 L+₹3.8 L (19.5%)Rejected-AOC 3491 14 HARIPURA DHAPAI ROAD AMRITSAR | AMRITSAR | PUNJAB | 143001 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
28 Dec 2021, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003 Tele 01352757790
SPL REPAIR TO BUILDING NO T 81 T 87 AND T 94 of 629 SATA BTY AT RAIWALA MILITARY STATION
2021_MES_492626_1
86339/RWL/E8
Open Tender
Civil Works
Item Rate
150 days
AGE I Raiwala
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE I Raiwala
₹48,000
31 Jan 2022
4 Dec 2021
30 Dec 2021
4 Dec 2021
28 Dec 2021
16 Dec 2021
4 Dec 2021 - 11 Dec 2021
Amount
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed.
Taking down cement plaster on walls of any description including racking out joints, hacking for key scrubbing down with water etc including removal of rubbish out side complex (MOD land), complete al as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls external surfaces in two layerss first layer of 10 mm in CM 1:6 & 2nd layer of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth without using extra cement complete all as specified and directed. Note:- Integral water proofing liquid will be measured and paid seperately under relevent item of Sch A.
Supply only Integral liquid water proofing compound ISI Marked as approved complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces of brick work in CM 1:6 on walls finishing the surface even & smooth complete all as specified and directed.
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
M & L for rughening surface of old floor by picking, swaping clean and concrete washing down with water to remove dust etc and providing 18-20 mm thick machine cut kota stone slab flooring over cement screed base laid and incl 20 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing (mirror polishing) complete all as specified and directed.
M & L for 16-18 mm thick machine cut pre polished kota stone slab as in riser of steps, skirting in full length in single peace without joint, of stair width laid over and incl 10 mm thick rendering of CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade including necessary grinding, rubbing and polishing complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 4 mm thick glass dividing strip of figured glass, pin headed type, 73 mm wide inserted in position complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including removal from site complete all as specified and directed.
S&F false 4mm thick E-board (designer) as in false ceiling with GI framed work with main tee of size 24X28.5 mm made out of PGI sheet 0.3 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and wall angle 24X24X0.45 mm powder coated for celing, ceiling board 60cmX60cmX4.0 mm thick , suspended with GI wire 2 mm dia & upto 2 M average length with adjustable device complete including plugging in brick /stone wall with steel rawal plugs @ 600 mm C/C or tying with wooden or steel truss member. Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides including making good all the disturbed portion, complete all as specified and directed. Note:- False Ceiling material including GI frame shall be powder coated alongwith all assessories shall be of same make.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.50 but n exc.4.00 sqm each including removal from site complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc. 1.50 sqm each including removal from site complete all as specified and directed.
S&F 125 mm x 65 mm Double Rebate Factory made 100% Solid PVC/WPC door Frame made from 100% LEAD FREE (Single extruded process) material with density 780 kg / Cum & Manufactured by an ISO:9001-2015 certified company, all as per specification drawing as directed by the Engineer-In-Charge.The door frame should be Water proof, Termite proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY
S&F 30mm thick molded WPC factory made 1005 solid door shutter (confirming as per IS: 4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/cum manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, termite proof, fire retardent and having screw holding capasity complete all as specified & directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd) /FLORESTA/ARCHIDPLY
S&F 30 mm Thick factory made wire mesh solid PVC door shutters Consisting of frame made out of M.S tube of 19 guage thickness and size of 19 mm x 19 mm for stiles and 15 mm x 15 mm for top, lock & bottom rail. M.S frame shall have a coat of metal primer of approved make and manufacture. 19 mm x 19 mm M.S square tubes shall be covered with 5 mm thick pvc heat molded (100% lead free) plain sheet 'c' channel 75 x 30 x 60 out of 10 mm shall be heat at 90 deg. towards inner site of both site of both face of the door formingstiles for top, bottom, lock rails shall be fitting of 10 m site. all rails (T,B lock) shall be in covered with 100mm wide PVC sheet including S.S wire mesh shall be fixed with 15 x 15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove of fix again after changing of wire mesh when needed complete all as specified and directed. Make:- ENCHON (Kumar Arch Tech Pvt Ltd) /FLORESTA/ARCHIDPLY
S&F factory made solid panel pvc window shutter 30 mm single side (style) but fully glazed ie glass pane used instead of 5 mm single side prelam pvc sheet panel shutter frame made out of ms tubes for top and bottom rail MS frame shall be covered with heat moulded single side prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck in side solvent cement for stiles and single side prelame PVC sheet for top and bottom rail on either side and as gap insert for top rail and bottom rail glass pane to be fitted with suitable PVC sheet beading and jointed together with solvent cement complete all as per specification and drawing. Make:- ENCHON (Kumar Arch Tech Pvt Ltd) /FLORESTA/ARCHIDPLY
S&F factory made solid panel pvc window shutter 30 mm single side (style) but wire gauged ie panel will be of wire gauged used instead of 5 mm single side prelam pvc sheet panel shutter frame made out of ms tubes for top and bottom rail MS frame shall be covered with heat moulded single side prelam PVC 'C' channel having a PVC sheet strip of 20 mm width stuck in side solvent cement for stiles and single side prelame PVC sheet for top and bottom rail on either side and as gap insert for top rail and bottom rail the wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to ms tubes.The wire gauge shall be streched to tighten firmly complete all as per specification and drawing. Make:- ENCHON (Kumar Arch Tech Pvt Ltd) /FLORESTA/ARCHIDPLY
S&F 100 mm long stainless steel (AISI 316 grade) bearing hinges, 4 bearing, completed all as specified and directed.
S&F Aluminium anodized barrel tower bolt of size 12mm dia and 300 mm length of extruded section (ISI Marked) complete all as specified and directed.
S&F Aluminium anodized barrel tower bolt of size 12mm dia and 150 mm length of extruded section (ISI Marked) complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed (ISI Marked) complete all as specified and directed.
S&F Extruded Aluminium alloy handles,fabricated type, anodised 150mm long, (ISI Marked) complete all as specified and directed.
S&F Aluminium body door closer hydraulically regulated, designation No-1 universal type, suitable for door shutters of weight not more than 35.00 Kg fixed to door shutter complete all as specified and directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated steel sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality complete all as specified and directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated wood and wood based sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality complete all as specified and directed.
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/Ceiling etc, to match with the existing surfaces of wall/Ceiling complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit,medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
All as per item no 29 above but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per item no 29 here-in-before but for One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or equivalent make of L&T/Havells
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 52 / Indoasian cat no: 800020 or equivalent make of L&T/Havells
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals (ISI Marked) complete all as specified & directed.
S&F LED tube light batten 20 watts 4 fts polycarbonate housing, translucent diffuser with LED light source , 2200 lumen, natural white ,surge protection range 2KV, voltage protection range 120-280 VAC , 3 years warranty ,system efficacy not less than 110 Lm/watt for the fitting , power factor>0.95 total harmonic distortation<20% , colour rendering index >80, coefficient colour temp 6500 K, fixed on site with all accessories all as specified and directed. Make:- Havells cat No: LHEXACP7UN1W020 or Shakti cat No: SZSLBMX020 or Crompton cat No; LCTLN-20-NW Note :- (i) the firm has to give warranty for light fittings including driver minimum for 03 years for any defects developed during the period.
Supply and fix LED street/security light fitting 20W housing made out of pressure die-cast aluminium alloy with toughned glass, IP-66 protection, working on 240 Volts AC, 50 HZ, consisting of reflective lens wired with approximate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level > 10 KV, thermal short circuit protection THD < 10% made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency >140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency > 120 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 K- 6500 K including fixed on wall with 02 Nos MS clamp made out of 40 x 6 mm F1 and bracket made out of 40 mm dia light grade GI pipe not less than 1.0 mtr long bend to shape with use reducer for inner dia 38 mm for fix with inside light fitting including connecting with 1.5 sq mm, 3 core, PVC insulated Copper conductor cable 1100 Volta grade complete all as specified and as directed. Make:- Havells cat No: LHEXAYP7PN6K020 or Shakti cat No: SZPCLPM020 or Crompton cat No; TRP-400-20-57-SL-LM-NSR Note :- (i) the firm has to give warranty for street light fittings including driver minimum for 03 years for any defects developed during the period. (ii) The contractor shall submit the third party LM 79 & LM 80 report from any NABL approved laboratory. (iii) The fitting should have BIS, CRS (iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and rates are inclusive in above.
Taking down ceiling fan and deposit to MES store yard and Supply & fix energy efficient ceiling fan with BLDC motor and blades, 1200 mm sweep including electronic fan regulator, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with operating voltage of 140 to 285 V, with metallic finish , accessories / remote toggle switches complete all as specified and directed. Make:- Atomberg/Havells/Orient
S & F Double door sheet metal enclosure for DB, 8 way, SPN with 200 Amps rated bus bar, 240 Volts, ISI marked, 50 Hz suitable for housing MCBs and making good for distrubed surface with existing etc complete all as specified and directed.
Supply and fixing 10 KA 'B' curve miniature, circuit breaker (MCB) of single pole and neutral, current carrying capacity 5 to 32 AMP ISI marked, 230/240 volts, 50 Hz in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5-6 Amps, in the MCB DB complete with connection testing and commissioniing complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion and taking down old unserviceable earthing complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Supply & Fix batten holder ISI marked mounted on wall complete all as specified and directed.
Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall, LT panel board, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 16 sqmm 2 core with required aluminium cable lugs, lugs should properly crimp with crimpping tools, heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirement, including taking down old unserviceable service/UG cable of any size from building/trunches complete all as specified and directed. Note: Ecavation & earth work required shall be measured and paid separately under relevant item of sch A.
Excavation in trenches in any type of soil and n.exc 1.5 m wide and n. Exc 1.5 in depth for laying GI tubing for connect to near by water pipe line or for poles, laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and directed.
Returing, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, in any type of soil complete all as specified and directed.
Removing excavated material ( surplus soil) to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specifed and directed.
M&L for fine dry sand cushioning for underground cable by providing layers of sand 8 cm before laying and 15 cm deep after laying the cable including streching the cable complete all as specified and directed. Note:- Measurement of sand to be taken consolidated thickness after punning down.
M & L for cable protection bricks common burnt clay sub class 'B' designation 75 for protection of UG cable laid in trenches all as specified and directed at site complete all as specified and directed.
M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of minium size 150mm X 100mm in respect of width and thickness complete all as specified and directed.
Supply, laying & joined Galvanised Tubing 50 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc for cable protection including taking down old one complete all as specified and directed.
TARUN ENGINEERING WORKS
RAJENDER CONSTRUCTION CO
Malik Associates
AMARJEET SINGH AND CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .