Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.9 LAccepted-AOC D NO 71 31 950 CHINTALALOVA GANDHIGRAM POST VISAKHAPATNAM 530005 | VISAKHAPATANAM | ANDHRA PRADESH | 530005 | 1 | Accepted-AOC Being Lowest Bidder | |
| 2 | 2₹19.9 L+₹2.8 L (16.1%)Rejected-Finance D NO 71 31 96 6 ASRR COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | 3₹20.9 L+₹3.7 L (21.6%)Rejected-Finance | 3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | 4₹21.7 L+₹4.5 L (26.1%)Rejected-Finance | 4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | 5₹22.8 L+₹5.6 L (32.6%)Rejected-Finance D NO 71 31 252 DURGANAGAR MALKAPURAM VISAKHAPATNAM 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 Jun 2024, 6:00 pmClosed
Shri Azmat Arshi, IDSE, Garrison Engineer P Navy K
Garrison Engineer P Navy Kalinga, INS Kalinga Complex, INS Kalinga Post, Visakhapatnam - 531 163
Repair Replacement to Sewage Line, Manholes and Cleaning of Septic Tank, Manholes, SWT, Sewage Lines at INS Kalinga and INS Karna at Visakhapatnam
2024_MES_656541_1
8080 / E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class D
Category a ii
9 documents required · 9 mandatory
₹500
Garrison Engineer P Navy Kalinga
₹60,000
Yes
31 Aug 2024
29 May 2024
3 Jul 2024
29 May 2024
26 Jun 2024
12 Jun 2024
29 May 2024 - 5 Jun 2024
Amount
M & L for cleaning of Septic Tanks / Soak Wells / Man Holes etc. not exceeding 1.50m depth by pumping out the sewage water completely removing the Sludge, Silt, Debris etc. and other materials by suitable means, preferable mechanical means and Cleaning the internal surfaces with fresh water and applying Bleaching Powder @200 Grams per Sq.m and removing all the materials obtained to outside MD Land exceeding 5.00 KM distance and cleaning the complete area including making good any damages to the Septic Tanks / Soak Wells / Man Holes etc. complete all as required and as directed. Note: Quantity shall be measured from top of Sludge / Sewage Water Level to Bottom of Tank / Pit. The Foul / Waste Material and Sludge shall be disposed to out side MD land exceeding 5.00 KM distance. Nothing shall be paid extra for dewatering and cleaning with fresh water and applying Bleaching Powder and rate quoted shall be deemed to be inclusive of the same. The cleaning shall be carried out in a Phased Manner Periodically as required and as directed by the Engineer-in-Charge. Bleaching Powder shall be measured and paid separately.
All as per Serial Item No. 1 above but Depth of Septic Tanks / Soak Wells / Man Holes etc. exceeding 1.50m and not exceeding 4.50m complete all as specified and directed.
Supply only Bleaching Powder [ISI Marked] complete all as specified and as directed.
M & L for Clearing the blockage in the Sewage Lines of 100mm dia completely by rodding with Split Bamboo / Cleaning Rods preferably by Mechanical means so as to clean the Blockage and to enable the Sewage / Effluent to flow freely to the next Manhole, removal of sludge and other materials obtained from the Sewage Line to outside MD Land exceeding 5.00 KM distance, flushing the Seawage Line with Water including pumping of Sewage Water and cleaning the complete area including making good any damages to the sewage line or manholes complete all as required and as directed.
M & L for Clearing the blockage in the Sewage Lines of 150mm dia completely by rodding with Split Bamboo / Cleaning Rods preferably by Mechanical means so as to clean the Blockage and to enable the Sewage / Effluent to flow freely to the next Manhole, removal of sludge and other materials obtained from the Sewage Line to outside MD Land exceeding 5.00 KM distance, flushing the Seawage Line with Water including pumping of Sewage Water and cleaning the complete area including making good any damages to the sewage line or manholes complete all as required and as directed.
M & L for Clearing the blockage in the Sewage Lines of 200mm dia completely by rodding with Split Bamboo / Cleaning Rods preferably by Mechanical means so as to clean the Blockage and to enable the Sewage / Effluent to flow freely to the next Manhole, removal of sludge and other materials obtained from the Sewage Line to outside MD Land exceeding 5.00 KM distance, flushing the Seawage Line with Water including pumping of Sewage Water and cleaning the complete area including making good any damages to the sewage line or manholes complete all as required and as directed.
M & L for Removing blockages from Water Closets [Blocked / Choked] completely including connecting Traps, Spouts and Sewer Lines of any bore up to First Manhole preferably by manually means and by carefully Roding soil pipe with Split Bamboos or Flexible GI Wire etc to enable the flush water to flow freely to the Manholes to the entire satisfaction of user concerned and complete all as required and as directed.
M & L for cleaning the blockage in Gully Trap / Floor Trap / Nahani Trap completely to enable the sewage to flow freely to the next manhole, removing the sludge and other materials from the Traps by suitable means and removing all the materials obtained from the Traps to outside MD Land exceeding 5.00 KM distance and cleaning the complete area including making good any damages to the Traps to the entire satisfaction of user concerned complete all as required and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth not exceeding 1.5m and getting out in Soft / Loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and depth exceeding 1.5m but not exceeding 3.0m and getting out in Soft / Loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Demolition and Breaking up Drain Pipes, Salt Glazed / AC / PVC etc. of 100mm bore, Set in Cement Mortar including Concrete Bed and Haunching complete all as specified and directed.
Demolition and Breaking up Drain Pipes, Salt Glazed / AC / PVC etc. of 150mm bore, Set in Cement Mortar including Concrete Bed and Haunching complete all as specified and directed.
Demolition and Breaking up Drain Pipes, Salt Glazed / AC / PVC etc. of 200mm bore, Set in Cement Mortar including Concrete Bed and Haunching complete all as specified and directed.
M & L for concrete bed to drain pipes of size 100 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
M & L for concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
M & L for concrete bed to drain pipes of size 200 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 150mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 200mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Dismantling Stone Pitching in Portions built in Cement Mortar including levelling the dismantled area to get the even surface by removing the vegetation etc. complete all as specified and as directed.
M & L for Boulder Pitching, hand packed tightly, grouted with Cement Mortar 1:6 complete all as specified and directed.
All as per Serial Item No. 24 above but except Boulders complete all as specified and directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 6mm dia bars at every fourth course of brick work complete all as specified and as directed.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for PCC 1:3:6, Type C–2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for providing Precast RCC 1:1½:3, Type A-1, using 20mm graded stone aggregate as in Landings, Cover Slabs [for Manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in Cement Mortar 1:4 complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M & L for PCC 1:3:6, Type C-2 [using 40 mm graded granite stone aggregate] in surface channels and drains including forming fair finished drain or channel of any inner girth using extra cement including forms, moulds, mitred / stooped ends complete all as specified and as directed.
M & L for providing Cement Concrete, Type B1, 1:2:4 using 20mm Graded Aggregate as in Lintels up to 1.5m Clear Span, Cills, Steps, Seismic and other Similar Bands, Plinth Courses, Copings, Bed Plates etc. complete including necessary formwork complete all as specified and as directed.
M & L for brushing neat Cement Slurry with 3.0 KG of cement per Sq.m area complete all as specified and as directed.
M & L for Forming Fair Finished Drain or Channel 30cm Inner Girth in Cement Concrete, using extra cement, including Forms, Moulds, Mitred / Stopped ends etc. complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for rendering on fair faces of brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only Integral Water Proofing Compound [ISI marked] of approved make complete all as specified and as directed.
Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting exceeding 20 cm girth brick walls complete all as specified and as directed.
S & F in repairs PVC Nahani Trap 100mm dia with Grating including jointing to waste pipe fixed in Cement Concrete, Type B1, 1:2:4 complete all as specified and as directed.
S & F in repairs 100mm Diameter Stainless Steel Anti Cockroach Floor Trap with SS Grating including jointing to Nahani Trap, fixed in PCC 1:2:4, Type B0 using 10mm graded stone aggregate complete all as specified and as directed.
M & L for Loose Filling with broken Bricks of gauge 80 to 150mm in soakage pits etc. complete all as specified and directed.
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal without access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal without access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Double [Double "T"] equal or unequal without access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Double [Double "T"] equal or unequal without access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
S & F PVC [SWR] Gully Trap 125/110 mm, with grating including setting and jointing with solvent cement complete all as specified and as directed.
M & L for Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 1000mm and depth not exceeding 500mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick over 100mm-300mm thick Hardcore of Guage 40mm-63mm size boulders over 100mm thick Sand filling complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
S & F in repairs Vitreous China Squatting Pan "Orissa Pattern" of size 580 mm X 440 mm, White with integral foot rests and 'P' or 'S' trap including provision of lime concrete bedding complete all as specified and as directed.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White including Plastic Water Closet Seat back closed pattern with Flat Bottom and Cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' Trap complete all as specified and as directed.
S & F in repairs 10 Litres capacity, PVC Valve less, Syphonic action type, Low Level Flushing Ccistern, White, with Inlet Ball Valve, Float, Handle, including Brackets and Connections to Pipe and Flush Pipe complete all as specified and as directed.
S & F in repairs 32mm dia PVC Flexible Waste Pipe, 750 mm long fixed to Wash Hand Basin or Sink in repairs complete all as specified and directed.
S & F in repairs 40mm dia PVC flexible Waste Pipe, 750 mm long fixed to Wash Hand Basin or Sink in repairs complete all as specified and directed.
S & F in repairs PVC Connection of 15mm Bore and 450mm long with PTMT check nut and union etc complete all as specified and as directed.
S & F Mild Steel Bars, 10 mm dia and over cut to length, bent to shape required as in Rungs of Manholes embedded in Concrete and fixed with support complete all as specified and as directed.
M & L for Uprooting and Removal of Wild Trees / Grass / Bushes etc. from the Manholes / Soil Pipes / Septic Tanks / Soak Wells and their surroundings including its penetrated roots and making good the damaged plaster with Cement Mortar [1:3] and finished the surfaces to match with existing surfaces complete all as specified and as directed.
S & F Mild Steel work confirming to Fe - 290, Grade E-165, as in framed work such as Grills, Gratings, Ladders etc with ends of bars shouldered and/or riveted, or forged into spikes, framed Guard Bars, Barred Iron Doors, Ladders, framed Balusters, Walk Ways, Railings, framework of Water Tanks and similar work complete all as specified and as directed.
M & L for Making good Masonry Walls / RCC Walls damaged during replacement of Pipe lines etc. on vertical wall surfaces at any height with Cement Mortar [1:3] or PCC 1:2:4, Type B-0 using 10mm graded stone aggregate and finished the surfaces to match with existing surfaces including painting as per existing treatment complete all as specified and as directed.
SRI RAJA RAJESWARI ENTERPRISES
SSV CONSTRUCTIONS
SWATHI CONSTRUCTIONS
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
P SRINIVASA RAO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .