Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, installation and Commissioning of split window type Air Conditioning system as and when emergently required in essential areas of Trpura High Court Building, New Assembly Building, Chief Justice Dak Bungalow, New Secretariat Building and R
2024_CEPWD_47304_1
55/EE/DNIeT/MECH.DIVN/AGT/2023
Open Tender
Electrical Works
Works
365 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹48,466
26 Jun 2024
19 Feb 2024
2 Mar 2024
19 Feb 2024
2 Mar 2024
19 Feb 2024
Amount
Providing star rated ( Minimum 3 star with applicable ISEER according to current industry standard ) split type high wall A C machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant as supplied with AC machine, necessary plug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS (Part-II) speceification ( Except power consumption) suitable for operation on 230 volt, 50Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
1.0 TR (rated cooling capacity should not be less than 3000 Kcal/hr or 12000 Bthu/ hr or 3500 watt)
1.5 TR (rated cooling capacity should not be less than 4500 Kcal/hr or18000 Bthu/ hr or 5250 watt)
2.0 TR (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 Bthu/ hr or 7000 watt)
Providing star rated ( Minimum 3 star with applicable ISEER according to current industry standard) window type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant as supplied with AC machine, necessary plug top (With 01 year overall machine and compressor warranty) suitable for window type conforming to IS (Part-II) specification (Except power consumption)suitable for opretion on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
1.5 TR (rated cooling capacity should not be less than 4500cal/hr or 18000 BThu/ hr or 5250 watt)
Providing split type high wall A C machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermeticaly sealed compressor operating on non CFC refrigerant as supplied with AC machine, necessary plug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall/ceiling mounting conforming to IS (Part-II) specification ( Except power consumption) suitable for opretion on 420 volt, 50Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
2.5 TR (rated cooling capacity should not be less than 7500 Kcal/hr or 30000 Bthu/ hr or 8750 watt)
Providing split type high wall A C machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant as supplied with AC machine, necessary plug top IDU (with 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS (Part-II) specification ( Except power consumption) suitable for operation on 420 volt, 50Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
3.0 TR (rated cooling capacity should not be less than 9000 Kcal/hr or36000 Bthu/ hr or 10500 watt)
Providing split type ceiling mounting A C machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant as supplied with AC machine, necessary plug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall/ceiling mounting conforming to IS (Part-II) speceification (Except powwer consumption)suitable for opretion on 420 volt, 50Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
3.0 TR (rated cooling capacity should not be less than 9000 Kcal/hr or 36000 BThu/ hr or 10500 watt)
4.0 TR (rated cooling capacity should not be less than 12000 Kcal/hr or 48000 Bthu/ hr or 14000 watt)
Providing standard tower/floor mounting vertical split type A C machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermeticaly sealed compressor operating on non CFC refrigerant as supplied with AC machine, necessary plug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall/ceiling mounting conforming to IS (Part-II) specification (Except power consumption) suitable for opretion on 420 volt,50Hz, three phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated
3.0 TR (rated cooling capacity should not be less than 10500 Kcal/hr or 42000 Bthu/ hr or 10500 watt)
4.0 TR (rated cooling capacity should not be less than 12000 Kcal/hr or 48000 Bthu/ hr or 14000 watt)
Standard installation, testing and commissioning of 1.0/ 1.5 / 2.0 TR split and window type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 2.5/ 3.0 / 4.0 TR high wall and ceiling mounting split typemachine including hole cutting, finishiing etc. as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 3.0 / 4.0 TR tower / floor mounting vertical split type AC machine including hole cutting, finishing etc.as per direction of the Engineer-in-charge.
Fabrication of M.S. platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type Acs including all accessories for onsite installation i/c painting , fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply installation of additional length of copper pipe beyond 10 fit length of 5/8'',3 /8", 1 /2" and 1/4" diamiter for suction and liquid line with installation and necessary wiring between indoor and outdoor units.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_48086.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .