Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC AOC | |
| 2 | L2₹44.5 L+₹4.4 L (10.9%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹45.1 L+₹4.9 L (12.3%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹45.7 L+₹5.6 L (13.9%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹45.8 L+₹5.6 L (14.0%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹24.1 L
EMD Value
₹48,200
Closing Date
30 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
ADDITION ALTERATION AND IMPROVEMENT TO BLDG No P 106 AND 106A UNDER GE I NAVY JAMNAGAR
2021_MES_436047_2
8501
Open Tender
Civil Works
Item Rate
120 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹48,200
Yes
31 Dec 2021
16 Jun 2021
2 Jul 2021
16 Jun 2021
30 Jun 2021
24 Jun 2021
16 Jun 2021 - 23 Jun 2021
60 days
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etcand removal of entire debris as ordered outside MoD land complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etcand removal of entire debris as ordered outside MoD land complete all as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick above or below ground level and removal of entire debris as ordered outside MD land complete all as directed.
Dismantling of Corrugated or semi corrugated steel sheeting etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris to a distance not exceeding 50 mtr and depositing where directed complete all as directed.
Dismantling wrought iron or mild steel work of any description not othewise provided for complete all as directed,
Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MD land complete all as directed.
Dismantling of timber scantlings 40 Sq cm and over in section in any position unframed work and stacking at site where directed complete.
Taking down chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from frame) and stacking at site where directed.
All as per item No. 8 here-in-above but exceeding 1.5 Sqm but not exceeding 4 Sqm each
M&L for plain cement concrete 1:2:4 type B1 using 20 mm graded granite stone aggregate as in cast in situ in cills and other similar bands, plinth courses, roof kerb and padding, bed plates including necessary form work, weathering slightly rounded chamfered angles and throating including demolition of existing padding complete all as specified and directed.
M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified.
Supply only Integral Water Proofing Compound (ISI Marked) of Make : CICO , Acco Proof , Impermo , Aqua flex as approved.
M&L Second class hard wood well seasoned wooden scantling clean sawn unframed fixed complete all as directed.
S&F 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination complete all as directed.
S&F 100 mm size butt hinges, (ISI) marked stainless steel and fixed .
S & F 200 mm long aluminium, anodised , barrel tower bolt (ISI marked) of extruded section and fixed.
S & F 150 mm long aluminium, anodised , decorated / fancy handle (ISI marked) of extruded section and fixed.
S & F aluminium door closer hydraulically regulated, designation No. 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed as per manufacturers instructions complete all as directed.
S&F 100 mm size floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as directed.
S&F brass mortice lock, 4 levers , vertical type, size100 mm complete all as directed. Make : Godrej/ Harrison/ Link
S&F XPM design aluminium alloy wire mesh, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples along with wooden beads.
S&F anodised aluminium powder coated (thickness or powder coating not less than 50 micron) for doors, windows and ventilator frames and shutters, with or without sash bars, aluminium section weighing minimum 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws for fixing glass etc. complete all as directed. Note: Glass shall be measured and paid separately.
S & F 10 mm dia and over TMT bars cut to length bent to shape required cranking including bending , hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No. 23 here- in – above but 5 mm dia and over upto 10 mm dia as in stirrups - do -
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410 W (Gde E-250) quality-A.
S&F mild steel tubular work in tubular trusses, roof trusses (framed), trussed, purlins, crane gantries, rails and fastemings and heavy bracket framing ( Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 with one coat of zinc chromate primer paint.
S&F pre-painted galvalume (zincalume) aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/cladding to walls fixed with self tapping screws as specified.
Supply and fix Pre- painted galvalume aluminum zinc coating GI plain sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction all as specified and as directed.
Dismantling of any type of ceiling boards after electrically disconnection and taking down electrial fittings & fixtures including wiring stacking at site & S&F new 10 to 12 mm thick mineral fibre (fine fissured), baords fixed or laid / inserted to aluminium frame work with screws fixed to false ceiling with and including GI powder coated snap Grid 605 x 605 mm frame work using 25mm x 35mm x 0.7mm main Tee runner to be interlocked , 25mm x 35mm x 0.75mm cross Tee and 25x35x0.70mm angles fixed to wall for ceiling including necessary supporting hanger with 6 mm dia GI (upto 2.5m long adjustable) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 25x7mm size 60mm long for securing frame work to ceiling suspended at 120cm etc. both way. (Size of grid shall be 605mm x 605mm) including 10 to 12 mm thick mineral fibre (fine fissured) as described fixing with clips etc. and ceiling baord fixed as per manufacturerrs instructions and finally fixing the taken down fittings & fixtures & wiring to its orginal postion are different locations including testing on completion as ordered complete alll as directed. (Note:(i) The quoted rate is deemed to be incluvise of non asbestos fibre board, GI powder coated snap grid, susupenders complete (ii) Quoted rate shall be inclusive of taking down existing E&M fittings and wiring in ceiling if any, and re-fixing the same in position, after completion of ceiling work without any extra cost to Govt.)
Material and labour for removal of existing WPT course or any other kind of treatment surface over roof slab including removing layer of plaster and cleaning of surface with wire brushes and water removing of unsolvent materials and and depositing of the same as directed outside MoD land and provide 15 mm thick screed bed/ bedding layer in CM 1:3 mixed with Water Proofing Compound (WPC) as per manufacturer instructions, including finishing the surface fair and even on RCC roof/ parapet once bedding layer of concrete is completely dried and apply oil bound bituminous primer @ 0.30 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure as directed and finally finished the top surface with two coats of thermal resistant paint complete all as specified and as directed. Note: (i) The quoted rate is deemed to be inclusive of taking down & removal of debris , 15 mm thick 1:3 screed & complete APP treatment. (ii) WPC will be paid saperately (iii) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT (iv) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
S&F 4mm thick ACP pannel cladding, or eaves fixing on vertical or horizontal MS frame work and filling silicon gel for grove including fixing of Screw ( Make : INDO BOND or Equuivalent) complete all as directed.
M&L for repairing of cracks by cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as directed.
M&L for 25 mm thick plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in levelling course complete all as specified and as directed.
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 using 20 mm graded crushed stone aggregate as in plinth protection, hard standing finished the surface even and smooth using extra cement including forming joints and filling with bituminous filler material complete all as directed.
M&L double charged vitrified coloured tiles in light shade of size 800x800x10 mm thick (square/ rectangular) polished in floors etc. tiles laid over and including 20 mm thick screed bed in cement mortar 1 :6 set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed in floor surfaces complete all directed.
All same as per item No. 35 here - in - above but light shades as in dado & skirting with 10 mm thick 1 : 4 cement mortar screed - do -
M&L vitrified ceramic tiles in light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 1.00 sqm in floors etc. tiles laid over and including 15 mm thick screed bed in cement mortar 1 :6 set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed in floor and wall surfaces complete all as directed. (Note : i) Quoted rate is deemed to be inclusive of cement screed. ii) Colour of tiles shall be got appproved before incorporation in the work.)
M&L 16-18 mm thick granite slab (of any quality) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin counter and like set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite tiles laid over and including 20 mm thick screed bed in cement mortar 1 :6 set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed in floor surfaces complete all directed.(Note for item Nos 35 to 38 : i) Quoted rate is deemed to be inclusive of cement screed. ii) Shade / pattern / Colour of tiles shall be got appproved before procurement).
M&L 10-12 mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as directed..
M&L for cement tiles plain of size 300x300x25 mm machine made laid over and including 20mm thick cement mortal screed 1:4, set joined and pointed in cement mortal 1:3 mixed with 5% crude oil by weight of cement over app membrane complete all as specified and as directed.(Note : Quoted rate is deemed to be inclusive of cement screed & crude oil).
M&L for rendering 15 mm thick in CM 1:6 on stone or block masonry surfaces or surface other than fair faces brick work, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of stone or block masonary surfaces mixed with WPC as per manufacturer instruction , and finished the surface fair and even complete all as specified and directed. .(Note: WPC shall be measured and paid separately).
M&L preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of 1 mm thick birla white putty complete all as specified.
M&L preparing newly plastered or unplastered surfaces of exterior walls and applying two coats of antifungal exterior emulsion weather proof paint (Apex) over a coat of alkali resistant primer complete all as specified.
S&F 5.5mm thick sheet glass, ordinary quality and glazing with rubber bearding (neoprene) exceeding 0.5 Sqm in each pane complete all as directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as directed.
S&F 4mm thick figured glass, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as directed.
M & L Two coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surface complete all as directed.
One coat of first quality synthetic enamel paint of any description over 10 cm in width or girth on old painted steel surface after necessary preparation of surface complete all as directed.
M & L Two coats of 1st quality synthetic enamel paint over a coat of pink primer on new wooden surface of any description over 10 cm in width or girth including necessary preparation of new wooden surface complete all as directed.
One coat of first quality synthetic enamel paint of any description over 10 cm in width or girth on old painted wooden surface after necessary preparation of surface complete all as directed.
M&L for complete removal of existing wooden paint and applying two or more coats of French polishing till to obtain mirror finish on wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works complete all as directed.
Taking up or down old GI tubing 15 mm bore and connection including cleaning for re-fixing stacking at site where directed .
All as per item No. 53 here-in-above but 20 mm bore of pipe - do -
Fixing only 15 mm bore GI tube medium grade with all new fittings (ISI Marked) fixed to wall and ceiling or laid in floors making necessary connection and testing complete all as directed.
All as per item No. 55 here-in-above but 20 mm bore of pipe - do -
M & L for 15 mm bore steel water tubing medium grade (ISI marked) with fittings all new (ISI marked) fixed to wall and ceiling or laid in floors complete all as directed.
All as per item No 57 here -in - above but 20 mm bore of pipe.
Disconnecting existing tanks fixed in any description of capacity exc 500 ltrs but not exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified.
E&M WORKS: Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site and making good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed.
Taking down carefully unservicable main switch and DB's including wooden board and removing from site including making good disturbed surface of walls complete all as directed.
Dismantling and taking down fluorescent tube light single /double of any wattage & size , security light fittings for repair or replacement of burnt / wornout accessoriescomplete all as directed.
M & L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including PVC rigid non metalic conduit /casing and caping with all fittings such as internal bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories, with GI pressed steel / PVC box suitable for modular switches sunken boxes (with earth dolly) covered with logic modular PVC sheet cover for fixing of switches, sockets etc including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- NOTE: - Switch and socket to be measured and paid for separately. (a) One light point controlled by one 5/6 amps one way switch.
(b) One Socket outlet, three/five pin, 6 Amp, controlled by one 5/6 amps one way switch or switch/socket combination 6 amps, 5 pin on same board with other switches, sockets, fan regulators, etc.
(c) One Socket outlet, three/five pin, 6 Amp, controlled by one 5/6 amps one way switch or switch/socket combination 6 amps, 5 pin on independent board.
All as per item No. 63 here-in-above but with 2.5 Sqmm cables for one 16Amps , 6-Pin socket outlet point on independent board .
S&F in repairs switch modular type single pole one way 6 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in Philips / Crabtree / ABB / Havells
S&F switch modular type single pole one way 16 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 11 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet 2/3 Pin 6 Amp modular type all accessories complete all as directed. Make: Legrand Cat No. 6755 52 or equivalent in Philips / Crabtree / ABB / Havells
S&F socket outlet multipurpose 2/3 Pin for 6 / 16 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 55 or equivalent in Philips / Crabtree / ABB / Havells
S & F Ceiling rose surface bakelite White / Ivory / Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
S&F new LED Recess mounted LED light fittings 36 Watts white powder coated CRCA housing with full window acrylic diffuser (2ftx2ft) the CCT should be between 3000k to 6500k fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Model ULTIMA ULTRA , Cat No LULTO1SO36XC or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
S&F 10W LED round focus light fittings, track-mounted, moveable base, fully adjustable, Beam angle 40º, Aluminium Housing (including Driver casing), the CCT(k) should be 3000 to 5000, fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No LTRLW1R010XC/N/W or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
S&F epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB TPN 4 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No 5076 70 or equivalent of Havells / L&T / ABB
S&F in repairs MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 87 to 4085 95 / Havells / L&T / ABB
S&F in repairs MCB SPN 40 to 63 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 408618 to 408620 or equivalent of Havells / L&T / ABB
S&F in repairs MCB TPN 63 Amp, 240 V, 50 Hz, AC supply. Make: Legrand Cat No. 4086 83 / Havells / L&T / ABB
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 6 Sq.mm PVC insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 6 Sq.mm one run complete. Note: 2 run of 6 Sq.mm cable one run 6 Sq.mm earth wire with casing capping considered as one unit.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 4 Sq.mm PVC FRLS insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 4 Sq.mm one run complete. Note: 2 run of 4 Sq.mm cable one run 4 Sq.mm earth wire with casing capping considered as one unit.
Supply and lay cable in trenches or fixing on wall or pole XLPE cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (heavy duty) with standard aluminium conductor 1100 volt grade cross sectional area 25 Sqmm 4 core making necessary connection & testing on completion all as directed.
S&F 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, fixed to wall, ceilings or in floors etc. complete as directed.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing complete all as specified including testing on completion.
Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole, laying of cables, stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in soft / loose soil.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 Mts and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
SIBS CONTRACTOR
S t modi
M/s Balaji Enterprise
badri glass and construction
JAYESH TRADING CORPORATION
Jyoti Refrigeration
ambika electric co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .