| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.7 L+₹2.7 L (9.35%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹31.9 L+₹2.9 L (10.1%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹31.9 L+₹3.0 L (10.3%)Rejected-Finance SHIVAJI NIWAS VILL CHIMBALHAR P O GEETA PEETH PALAMPUR HP 176061 | KANGRA | HIMACHAL PRADESH | 176061 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹32.4 L+₹3.4 L (11.8%)Rejected-Finance YOL CAMP TEH DHARAMSHALA DISTT KANGRA HP | YOL | KANGRA | HIMACHAL PRADESH | 176052 | L5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | M/S MADAN GOPAL and CO L1 | MM Constructions L4 | KISHAN CONTRACTOR L3 | M/S SURINDER KUMAR MAHAJAN L8 | Eshaan Construction Co. L7 | gani bhatti and co L6 | RIHANA ENGINEERS L2 | M/S AMOLAK SINGH AND SONS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation over areas not exc 1.50 m deep and getting out in any type of soil, complete all as specified and directed. | 3 | Cum | 150 ₹450 Lowest | 200 ₹600 | 200 ₹600 | 200 ₹600 | 500 ₹1,500 | 150 ₹450 Lowest | 150 ₹450 Lowest | 200 ₹600 |
| 2.00 | Excavation in trenches n exc 1.50 metre wide & n exc 1.50 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n exc 1.50 metre in depth and getting out in any type of soil, complete all as specified and directed. | 5.5 | Cum | 190 ₹1,045 | 200 ₹1,100 | 200 ₹1,100 | 200 ₹1,100 | 500 ₹2,750 | 165 ₹907.5 Lowest | 500 ₹2,750 | 200 ₹1,100 |
| 3.00 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick each layer of soil, complete all as specified and directed. | 3 | Cum | 45 ₹135 Lowest | 50 ₹150 | 150 ₹450 | 100 ₹300 | 100 ₹300 | 80 ₹240 | 100 ₹300 | 50 ₹150 |
| 4.00 | Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point, complete all as specified and directed. | 5.5 | Cum | 50 ₹275 Lowest | 70 ₹385 | 100 ₹550 | 100 ₹550 | 100 ₹550 | 70 ₹385 | 500 ₹2,750 | 50 ₹275 Lowest |
| 5.00 | Plain cement concrete 1:4:8, type D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed. | 0.7 | Cum | 2,300 ₹1,610 Lowest | 3,500 ₹2,450 | 4,650 ₹3,255 | 4,000 ₹2,800 | 4,500 ₹3,150 | 4,000 ₹2,800 | 5,000 ₹3,500 | 3,000 ₹2,100 |
| 6.00 | Reinforced cement concrete (nominal mix) M-15, type B-1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.50m span, complete all as specified and directed. Note:- Reinforcement and form work shall be measured and paid separately. | 1.1 | Cum | 3,700 ₹4,070 Lowest | 4,000 ₹4,400 | 5,500 ₹6,050 | 5,000 ₹5,500 | 6,500 ₹7,150 | 6,000 ₹6,600 | 7,000 ₹7,700 | 4,500 ₹4,950 |
| 7.00 | Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, including formwork, complete all as specified and directed. | 0.15 | Cum | 4,000 ₹600 | 4,000 ₹600 | 5,500 ₹825 | 5,000 ₹750 | 1,200 ₹180 Lowest | 6,500 ₹975 | 7,000 ₹1,050 | 6,000 ₹900 |
| 8.00 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. For fair finished flat surfaces of concrete, complete all as specified and directed. | 4 | Sqm | 150 ₹600 | 150 ₹600 | 140 ₹560 Lowest | 400 ₹1,600 | 300 ₹1,200 | 250 ₹1,000 | 400 ₹1,600 | 250 ₹1,000 |
| 9.00 | TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. | 88 | Kg | 87 ₹7,656 | 83 ₹7,304 | 90 ₹7,920 | 90 ₹7,920 | 75 ₹6,600 | 90 ₹7,920 | 70 ₹6,160 Lowest | 85 ₹7,480 |
| 10.00 | TMT steel bars 5 to 10mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, spacers and binders, complete all as specified and directed. | 35 | Kg | 85 ₹2,975 | 83 ₹2,905 | 80 ₹2,800 | 90 ₹3,150 | 75 ₹2,625 Lowest | 90 ₹3,150 | 85 ₹2,975 | 85 ₹2,975 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Aug 2025, 6:00 pmClosed
GE (KH) Yol
GE (KH) Yol Cantt, HP
Special repair to Bldg No T-05 and provn of single toilet in Bldg No T-10 at 25/4 Camp, Provn of acid resistant tiles for battery charging shop of 154 FWC and Provn of pathway, over head rain shelter under AGE B/R-I at Mil StnYol
2025_MES_722095_1
GE/Y-60/2025-26
Open Tender
Civil Works
Item Rate
GE (KH) Yol
As per NIT
7 documents required · 7 mandatory
₹500
GE (KH) Yol
₹80,000
Yes
10 Sept 2025
23 Jul 2025
23 Aug 2025
23 Jul 2025
21 Aug 2025
7 Aug 2025
Amount
Excavation over areas not exc 1.50 m deep and getting out in any type of soil, complete all as specified and directed.
Excavation in trenches n exc 1.50 metre wide & n exc 1.50 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n exc 1.50 metre in depth and getting out in any type of soil, complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm thick each layer of soil, complete all as specified and directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point, complete all as specified and directed.
Plain cement concrete 1:4:8, type D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
Reinforced cement concrete (nominal mix) M-15, type B-1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.50m span, complete all as specified and directed. Note:- Reinforcement and form work shall be measured and paid separately.
Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, including formwork, complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. For fair finished flat surfaces of concrete, complete all as specified and directed.
TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed.
TMT steel bars 5 to 10mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, spacers and binders, complete all as specified and directed.
Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed.
Damp proof course 25mm thick on horizontal or vertical surfaces using Plain cement concrete M-15, nominal mix, type B-0, using 12.5mm graded mechanically crushed stone aggregate including necessary formwork complete all as specified and directed..
Rendering cement plaster 15mm thick in two layers (first layer 10mm thick and second layer of 5mm thick) in cement mortar 1:6 (1 cement : 6 coarse sand) on other than fair faces of brick wall or stone masonary surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over 2mm thick plaster of paris putty including preparation of surface, complete all as specified and directed.
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layers and 5mm thick 2nd layer), mixed with WPC @ 3% by weight of cement on fair faces of brick walls or on concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. Note:- water proofing compound shall be measured and paid seperately.
Preparation of new plastered or unplastered surfaces of wall to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed.
Rolled mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. conforming to grade Fe.410-W Gde E-250, quality A, steel work, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall with two corrugations side lap, fixed with self tapping screws and washers, complete all as specified and directed.
Hardcore of broken stone or boulders of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
Plain cement concrete M-10, nominal mix, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5cm deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), complete all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
Plain cement concrete M-15, nominal mix, type B-0, using 12.50mm graded mechanically crushed stone aggregate as in flooring/levelling course, 25mm thick, surface finished even and fair to receive floor finishes surface, complete all as specified and directed.
Mat finish joint less (non skid), Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), including necessary cutting and waste as per site requirement, complete all as specified and directed by Engr-In-Charge. Note:- The size, shade and design will be approved by GE.
Glazed ceramic, premium quality, coloured/printed tiles of size 450mmx350mmx7 to 8mm thick as in skirting, dado etc and the like, set and jointed in neat cement slurry in white or coloured cement to match the shade of tile, laid over and including 10mm thick rendering in cement mortar 1:4 (1 cement : 4 coarse sand), including necessary cutting and waste as per site requirement, complete all as specified and directed by Engr-In-Charge. Note:- The size, shade and design will be approved by GE.
Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges shall be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 180 of MES SSR 2020 Part-II, complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5 mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site, as per specifications and drawing complete all as as specified and directed.
Anodised aluminium powder coated window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium including 5.5mm thick sheet glass tinted complete all specified and as directed by Engr-in-charge.
Butt hinges (ISI marked), medium weight, cold rolled, mild steel 100mm long, fixed, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 200mm with lipping frame to match, complete all as specified and directed.
Aluminium anodised, (ISI marked), barrel tower bolts of extruded section, length of bolt 150mm, fixed, complete all as specified and directed.
Extruded aluminium alloy handles (ISI marked), fabricated type, anodised, of size 150mm, complete all as specified and directed.
Applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel or steel based surfaces of any description, exceeding 10cm width or girth including preparation of surfaces, complete all as specified and directed.
Vitreous China wash down water closet (pedestal pattern), coloured including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC coloured seat cover black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device and chromium plated jet including 15mm dia PVC connection 600mm with CP brass coupling nuts and PVC washers at both ends, fixed, including 32mm dia PVC long bend flush pipe 90cm long pipe and fixed, complete all as specified and directed
Supply and fixing PVC valveless, syphonic action type flushing cistern 10 litres capacity low level with inlet, ball valve, float and handle with brackets including 32mm dia PVC long bend flush pipe 90cm long snd 15mm dia PVC connection 600mm with CP brass coupling nuts and PVC washers at both ends, fixed, complete all as specified and directed.
Vitreous China bowl Urinal, flat back 465x355x265mm, white (white (minimum) with grating and union for discharge pipe, complete including providing and fixing plugs, beding urinal against wall in cement mortar 1:2 securing urinal plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm bore PVC waste pipe, complete all as specified and directed.
Push button, cast copper alloy, chromium plated, fancy type for 15mm bore iron pipe suitable for urinal with flush valve concealed push type (Single flush) 32mm (1.25") complete all as specified and directed.
PVC Reducer coupling fixed at outlet of urinal pot including suitable length PVC flexible pipe 25mm dia (Minimum weight 32mm-45gms) all as directed.
Wash hand basins, Vitreous China (Table top basin) of size 510mm x 405mm x 185mm oval shape as per Cat No : ECS-WHT-703 of ESSCO or size 520mm x 310mm x 170mm Cat No 4719 of "PRAYAG" or size 410mm x 340mm x 150mm starwhite Cat. No.: 91088 of "HINDWARE" or size 370mm x 370mm x 115mm Cat. No. S2020107 of "CERA" as directed by Engr-in-charge, coloured, fixed in granite counter by making suitable holes, new brackets with and including cutting for and pinning on ends of brackets, fixed, 450mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, complete all as specified.
Salt glazed stoneware gully traps, size 150x150mm square or round mouthed, type 'P', complete all as specified and directed.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors bore 110mm, complete all as specified and directed.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors bore 75mm, complete all as specified and directed.
PVC (SWR) junction single, (Single T) equal or unequal, Branch piece 75mm bore, provided with oval access door, complete all as specified and directed.
PVC (SWR) junction single, (Single T) equal or unequal, Branch piece 110mm bore, provided with oval access door, complete all as specified and directed.
PVC (SWR) bends any radius, 75mm bore jointed with solvent cement, complete all as specified and directed.
PVC (SWR) bends any radius, 110mm bore jointed with solvent cement (fitted with or without oval access door), complete all as specified and directed.
PVC (SWR) 110mm vent cowl, complete all as specified and directed.
Cutting into existing manholes for connecting new drains of 150mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, complete all as specified and directed.
Mild steel galvanized iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed.
Mild steel galvanized iron water tubing 20mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed.
Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed. Make: Cat. No.: F280016/Cat. No.: F280020 of "HINDWARE' or F2002511/ F2002405 of "CERA" or Cat No. 8155/9055 of "PRAYAG" or Cat No. TQT-520/521S of "ESSCO".
Bib taps, fancy type 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, chromium plated screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
Angle Valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed, complete all as specified and directed.
Stop valve, cast copper alloy, fancy, type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed, complete all as specified and directed.
Ball brass valves 20mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
Soap dish approximate size 160x 160x90mm, chromium plated, fixed to plugs with chromium plated, brass screws, fixed, complete all as specified and directed.
Sheet glass shelf assembly 55cm long consisting of 5.50mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, fixed with chromium plated brass screws, complete all as specified and directed.
Brass Chromium Plated, Tubular towel rail, 20mm dia, D type, 60cm long between flanges, with brackets, fixed with chromium plated screws, complete all as specified and directed.
PVC connection 15mm size with PTMT nuts at boths end 600mm long and fixed, complete all as specified and directed.
Plain cement concrete M-10 nominal mix, type C-1 using 20mm graded mechanically crushed stone aggregate as in surface channel and drains, complete all as specified and directed.
Walling random rubble stone masonry with best quality locally available stone, uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
Rendering cement plaster 15mm thick in two layers (first layer 10mm thick and second layer of 5mm thick) in cement mortar 1:4 (1 cement : 4 coarse sand) on stone masonary surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed.
Chequered cement concrete tiles machine pressed of size 20cmx20cmx 25mm thick with grey cement, set jointed & pointed in neat cement slurry mixed with pigment to match the shade of the slab in floors laid over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Plain cement concrete M-15, nominal mix, B-0 using 12.50mm graded mechanically crushed stone aggregate as in lintels upto 1.50 metre clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as specified and directed. Note :- (i) The unit rate include for use of form work (straight or curved).
Rotational moulded polyethylene water storage tank 500 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipples with check nuts and washers complete and making connections with existing water supply line, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.50 cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, complete all as specified and directed.
Plain cement concrete M-10, nominal mix, C-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe.410-W Gde E-250, quality A, steel work, complete all as specified and directed.
Plain cement concrete M-7.5, nominal mix, type D-2, using 40mm graded mechanically crushed stone aggregate as in sub base, 75mm thick, surface finished even and fair, complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each and removing from site, complete all as specified and directed.
Mild steel work as in bolt hooks (stay) hook and pintle hinges, bands, straps, hold fasts, clamps, wall ties, cleats, fanhooks etc. or similar small articles conforming to grade Fe-290 grade E-165, all as specified.
Plain cement concrete M-10, nominal mix, C-1 using 20mm graded mechanically crushed stone aggregate as in bed block for hold fast, chamfered angles and throating, complete all as specified and directed. Note :- (i) The unit rate include for use of form work (straight or curved).
Taking down roof trusses, coupled rafters or trussed beams of clear span 8.00 metres and upto 12 metres, complete all as specified and directed.
Dismantling timber scantlings 40 sqcm and over in section, in any position, unframed work, complete all as specified and directed
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, posts embedded in concrete, complete all as specified and directed
Rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240s, steel work complete, all as specified.
Mild Steel framed work as Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete, conforming to Fe 290 Gde E-165, complete all as specified and directed
Dismantling plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion and packing filling of chowkhats in PCC M-15, type B-0, 04 nos of each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf. (iii) MS tower bolt 150mm long - 2 No per leaf. (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) MS work with angle or other section as in window gurad bars, grill. (ix) Fabrication & fixing arrangement as per drg No. CEPZ/ TD 06/07. Note:- (i) Above referred drawing has not been made part of tender. The same can be seen in the office of GE during working hours on any working day.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks of glavanised wire staple fixed with stainless steel wire staples, fixed, complete all as specified and directed.
Sheet glass 3mm thick ordinary quality and glazing with oil putty/wooden beads in squares, not exc. 0.5sqm in each pane, complete all as specified and directed.
4mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 Sqm in each pane, complete all as specified.
Preparation of old painted wooden surfaces of any description and otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and as directed.
Preparation of old painted steel surfaces of any description and otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete including removal of debris to a distance exc 1.50 km but n.exc 2 km outside the Military Station, complete all as specified and directed.
Mat finish joint less (non skid), Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, as in skirting, dado etc. set and jointed in neat cement slurry and including 10mm thick rendering in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed. including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed.
Mat finish joint less (non skid), Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness, laid bedded and pointed in any mortar in floors, aprons etc. including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed.
Poilishing existing kota stone floor surface to mirror finish all as directed by Engineer in charge.
Machine cut kota stone slab flooring 18-20mm thick of size not less than 550 mm X 550mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor, staircase (single piece should be user in riser/tread) etc, laid over and including 15mm screed layer in cement mortar 1:6 (1 cement : 6 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC sub base, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.50 km but n.exc 2 km outside the Military Station, complete all as specified and directed.
S&F false ceiling of Non asbestos(Designer) 4mm fibre cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thick fixed over and including anodised aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600mm X 600mm . The aluminium fram work will supported on side wall with the used of aluminium 'L' section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified directed by the Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars, complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
Walling random rubble stone masonry uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:4 (1 cement : 4 coarse sand) except stone, complete all as specified and directed.
Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed.
Dubbing out average 20mm thick on irregular face of stone masonary walls in cement morta 1:6 complete all as specified and directed.
Material and Labour for waterproofing of exterior walls, including complete removal of existing plaster including raking out joints and applying two coats of acrylic polymer modified high performance coating (Smartcare Ultra Block 2k). The treatment shall be done from ground level and providing 15mm thick cement plaster in CM 1:4 finished even and smooth, complete all as specified and as directed.
Applying two coats of cement base paint on newly plastered or previously undecorated wall surfaces over one coat of alkali based primer including preparation of surface, tint and shade as approved by Engr-in-Charge, complete all as specified and directed.
Supply only intergal water proofing compound, complete all as specified and directed.
Mild steel work in joist channel, angle or tee section fixed independantly without connection plate etc. conforming to grade Fe.410-0.Gde-E-250, steel work, all as specified.
S & F 0.63mm thick plain galvainsed mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete, all as specified.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 75mm, complete all as specified and directed.
Plain cement concrete 1:2:4, nominal mix, type B-2, using 40mm graded mechanically crushed stone aggregate as in sub base, 100mm thick, surface finished even and fair, complete all as specified and directed.
Machine cut kota stone slab 20-25 mm thick as in vertical surfaces such as in skirting/dado/riser to steps laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 10mm thick plastering in cement mortar 1:4 (1 cement : 4 coarse sand) including cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified.
Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), including necessary cutting and waste as per site requirement, complete all as specified and directed by Engr-In-Charge. Note:- The size, shade and design will be approved by GE.
S&F Prelaminted board 18/19mm thick exterior grade prelaminated both side with decorative choice lamination, fixed with screws to timber frame work as on wall panelling cup boards shutters/shelves (sliding or fixed), complete all as specified and directed.
Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed.
Supplying and laying of CPVC pipes, 20mm outer dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying floors, complete all as specified and directed.
Supplying and laying of CPVC pipes, 16mm outer dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying floors, complete all as specified and directed.
Supplying and laying of Female Brass Threaded Adaptor (FTA/ FBTA) of dia 16mm, complete all as specified and directed.
Supplying and laying of Female Brass Threaded Adaptor (FTA/ FBTA) of dia 20mm, complete all as specified and directed.
Sink made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, including 40mm dia waste pipe ,overall size 495mm x 420mm bowl size 410mm x 330mm x 160 mm, all as specified.
Brick work with old size fly ash bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed.
Plain cement concrete 1:3:6, nominal mix, type C-2, using 40mm graded mechanically crushed stone aggregate as in sub base, 100mm thick, surface finished even and fair, complete all as specified and directed.
Plain cement concrete M-15, nominal mix, B-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
Taking down carefully the existing aluminium/copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fan regulators, lamp holders, call bell, bell pushes any type etc by unscrewing and taken away from site, complete and make good the disturbed surface as existing, complete all as specified and directed.
Taking down submain wiring any type and any size and making good disturbed surface by using cement mortar, white cement, putty etc. and match with existing surfaces of walls, floors etc., complete all as specified and as directed.
Taking down sheet metal enclosure DBs, main switch board etc and making good distrubed surface to match with existing surface, complete all as specified and directed.
Point wiring with 1.50 Sqmm copper conductor FRLS (Multi strand) PVC insulated ISI Marked unsheathed cable in and including concealed PVC conduit, ISI marked of suitable size with all fittings/ accessories such as bends, cross, elbow, tees etc. of suitable size and also including PVC insulated ISI marked unsheathed 1.50 Sqmm copper multistranded conductor FLRS as phase, neutral and earth wire connected to common earth dolly and including concealed MS pressed steel of suitable sizes (modular sunken box) terminal boxes made from 1.60 mm thick sheet for mounting of switches, sockets, fan regulators, light fittings etc. and modular cover plate as top cover for one light point/exhaust fan point, ceiling fan controlled by one way switch complete all as specified and directed. Notes:- (i) Wiring colour code i.e Red/Yellow/Blue for phase, Black for neutral and Green for earth shall be maintained. (ii) Point wiring is considered for modular switches and sockets. Rate of metallic sunken box and other connected accessories required for modular point wiring included in quoted rates. (iii) Rate of modular switch and sockets will be paid seperately under relevant item. (iv) Rate of cutting chases, cement plaster, white wash and making good as existing surface included in quoted rates.
All as per item No 123 above but for 3 pin 5 Amp socket outlet on same board with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable complete all as specified and directed.
All as per serial item No '123' above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
All as per serial item No '123 above, but for 3 pin 15 amps socket out let on independent with 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed.
S & F for modular switch, 6A one way, single module, complete all as specified and directed.
S & F for modular switch 16A one way, single module, complete all as specified and directed.
S & F for modular socket for 6A 2/3 pin combined, 2 module, complete all as specified and directed.
S & F for modular socket for 6A/16A 5 pin combined, 2 module, complete all as specified and directed.
M & L for ceiling rose 65 x 50mm three terminals, fixed, complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt, 6000 K, 220 volts, AC decorative type with extruded polycarbonate having efficiency 120 lumens /watt with driver holder including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F LED tube light fitting inverter type 1x 20 W, 230V, ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly, energy efficient ready to use complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed.
S & F for MCB SP 6 to 32 amps 240 Volt,10 KA, 'B' series, complete all as specified and as directed.
S & F for MCB SPN 40 to 63 amps 240 Volt,10 KA, 'B' series, complete all as specified and as directed.
Sheet metal enclosures factory made flush fixed for DBs when MCBs to be used, single pole and neutral (double Door powder coated), 8 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed.
Supply and fix distribution board iron clad TPN DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface, complete all as specified and directed.
S & F MCB,TPN, 100 A capacity, 415 V, 10 KA, B series including taking down old MCB 4 Pole, complete all as specified and directed. Note: The connection to the MCBs shall be done through thimble/ lugs and no direct wire shall be connected to MCBs.
Supply and fixing of LED security light fitting 35W, 230V, AC, outdoor type with high pressure die cast aluminium housing with street optic lens and glass diffuser for uniform light distribution and inbuilt surage protection device (SPD) and heat resistant complete with driver, street light bracket made out of GI pipe 32/40mm dia medium grade GI pipe minimum 1.50m long including fixing with 02 Nos MS clamps made out of flat iron of size 30mmx5mm with nuts, bolts and washers including painting with impact and corrison resistant including thermal management in multiple optics complete with IP 65/66 protection complete K=6500K, complete all as specified and directed by Engr-In-Charge.
Supply and hanging ceiling fan including fan regulator step flush type speed controllor with complete fixing arrengement of size 1200 mm sweep, air delivery 210 CFM with service value 6 BEE, 5 star rated with brushless direct current motor (BLDC) including provision of copper multi stranded PVC insulated 1100 volts grade three core flexible cable for main connection with existing ceiling rose at point wiring complete all as specified and directed by Engr-in-Charge
M & L for submain wiring in and including PVC conduit 1.8 mm thick, 20 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 6 sqmm (FRLS) and one run of PVC insulated, unsheathed multistranded copper conductor 6 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM). Note: (a) Insulation test of point wiring to be carried out on completion of work. (b) Proper colour coding is to be maintained. (Ph-Red, N-Black,Earth- Green) (c) Two runs of single core cable with one run of earth cable and suitable size of conduit shall be measured as one RM. (d) Cutting chases for sub main wiring concealed PVC rigid conduit shall be deemed to be included in the quoted rate of item.
Supply and laying in trenches/through pipes or bore in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 25 sqmm x 4 core, 1100 Volts grade, complete all as specified and diercted.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25m below normal ground level with top edge of earth plate at a depth not less than 1.50m below ground level, earth plate surrounded by 15cm thick packed layer of charcoal and common salt alternatively upto 90cm and connected with and including galvanised iron strip 25mm X 4mm (as earth lead strip), by means of bolts, nuts, check nuts and washers of GI pipe 15mm bore light grade for protection from earth plate up to testing point for protection of strip, 20mm bore GI pipe medium grade for water with wire mesh and funnel for watering including necessary excavation and earh work, PCC chamber 1:3:6 type C-2 with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 40x40x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape and and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m, complete all as shown in electrical plate No. 03 of MES Schedule Part-I, complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC 1:2:4 type B-1, reinforcement with 8mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii) Earth electrodes shall be protected upto test point using necessary arrangement with suitable size GI pipe upto 7.50m and the rate includes in the unit rate of item. (iii) Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and rate includes in the unit rate of item.
Supply and fixing Exhaust fans, Steel body, single phase, 230 volts, 300 mm sweep including grouting the ragged bolts in wall, fixing the frame on the exhaust side and connecting up with PVC insulated three core 1.50 sqmm copper cable from ceiling rose to exhaust fan, complete all as specified and diercted.
S & F of sheet metal enclosures distribution boards, double door, VTPN, 415 volts 4 ways, as per IEC 61439-3, degree of protection IP-43 (one incoming three phase & twelve out goings single phase) for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed including and comprising of the following:- (a) MCCB FOUR POLE 160 amps, AC, 415 VOLTS 25 KA=01 No (for incoming). (b) MCB SP 06- 40 amps = 12 Nos (for outgoings) complete with 250 amps fully insulated copper bus bar for each phase and neutral link, prefitted masking sheet fixed flush in wall including chases wall for fixing DB, complete all as specified and diercted. Note :- (i) The DB shall be VTPN series of Make : Schneider or techno Equivalent in make of L&T/ ABB/legrand (ii) Connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble properly crimped (iii) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (iv) Double continuous earth wire shall be provided for each three phase DB from earthing mains duly. (v) Cutting chasing shall be part of job at no extra cost
Stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 20mm bore iron pipe or for unions and fixed in repairs complete, all as specified.
Fan regulator stepped type, electronic varying 5 Speeds 230 Volts, 50Hz, suitable for 1200/1400 mm sweep ceiling fans, fixed on existing phenolic laminated sheet all as specified
RIHANA ENGINEERS (BID ID -3393719)
KISHAN CONTRACTOR (BID ID -3400879)
MM Constructions (BID ID -3393942)
M/S AMOLAK SINGH AND SONS (BID ID -3393954)
gani bhatti and co (BID ID -3393570)
Eshaan Construction Co. (BID ID -3401493)
M/S SURINDER KUMAR MAHAJAN (BID ID -3401369)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .