Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹37.7 LAccepted-AOC | L-1 | Accepted-AOC Contractor is L-1 in this bid | |
| 2 | L-2₹41.8 L+₹3.9 L (10.3%)Rejected-Finance | L-2 | Rejected-Finance Contractor is L-2 in this bid | |
| 3 | L-3₹42.2 L+₹4.3 L (11.2%)Rejected-Finance VILL SAKRAH PO CHAMBI TEHSIL SUNDERNAGAR DISTT MANDI HP | SUNDERNAGAR | MANDI | HIMACHAL PRADESH | L-3 | Rejected-Finance Contractor is L-3 in this bid | |
| 4 | L-4₹43.9 L+₹6.0 L (15.8%)Rejected-Finance | L-4 | Rejected-Finance Contractor is L-4 in this bid | |
| 5 | L-5₹45.2 L+₹7.3 L (19.3%)Rejected-Finance SHYAM COTTAGE RAM NAGAR SHIMLA | SHIMLA | HIMACHAL PRADESH | 171001 | L-5 | Rejected-Finance Contractor is L-5 in this bid |
Tender Value
₹43.9 L
EMD Value
₹73,500
Closing Date
1 Jan 2024, 5:00 pmClosed
Executive Engineer JS Division Karsog
Executive Engineer JS Division Karsog
Prov LIS Randol Sabot in Tehsil Karsog Providing and Laying Rising Maind and Pumping machinery
2023_HPIPH_83017_1
HPIPH_KSG_2023_DEC_RANDOL
Open Tender
Civil Works - Others
Item Rate
180 days
Tattapani
Prov LIS Randol Sabot in Tehsil Karsog Providing and Laying Rising Maind and Pumping machinery
8 documents required · 8 mandatory
₹800
Yes
₹73,500
Yes
14 Mar 2024
22 Dec 2023
2 Jan 2024
22 Dec 2023
1 Jan 2024
22 Dec 2023
22 Dec 2023 - 30 Dec 2023
Amount
Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-Charge.
Providing, Laying, jointing and testing of MS Pipe L-290 (X-42) bevelled edged conforming to ISO:3183-2007 of following mentoned grade, diameter and wall thickness in trenches having random lengths of 5-7 mtrs including cost of fabrication of minimum 3 cut bends of required degree. The pipe shall have inside & out side Galvanisation at manufacturer work conforming to IS:4736 (with upto date ammendments). The pipe shall be jointed with circumferencial butt welded joints by electric arc welding with minimum three layers of welds so as to achive the minimum effective thorat thickness and strength of welds conforming to IS: 816-1969 sepecification, by using welding electrodes of 2.50 mm to 6.30 mm of Advani Oerlikon (Ador)- CITOJET / Esab make, conforming to IS:814-1991, at site of work complete in all respects, including manual / mechanical handling of pipes in all leads and lifts to the entire satisfication of Engineer-in-charge. (The earth work in treches and cost of MS flanges to be measured and paid for separately) Length of Flanged Joint 95%
1st stage RD 0 to 500, 200 mm dia MS Pipe 4.00 mm thickness, Flanged Table-17.
Providing, Laying, jointing and testing of GMSERW Pipe L-290 (X-42) of following dia meters to conforming to ISO:3183-2007 (latest with upto date amendments) having wall thickness as per code with plain end and capable of withstanding required test pressure in random length fo 4 to 7 mteres. The pipe shall have inside & out side glavanisation at manufactured work as per relivant IS standard including specials, short pieces bends, reducers, tees etc. made from parent tube, providing and welding of MS flages at suitable points to be provided 5% of total pipe length detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest upto date amendments) duly welded in three layers one inner and two outer to make the joint leakproof with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/ synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer-in-Charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and special made from the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminus paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of ADvani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer-in-Charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
Raw Water Stage RD 0 to 100, Dia 200 mm Class-GMSERW Pipe, Wall Thickness 4.00 mm, Flange Table- 5.
1st stage RD 0 to 500, Dia 200mm, Class-GMSERW Pipe, Wall Thickness 4.00 mm, Flange Table- 17.
(Submerssible Pump Set):- supply of submersible pump set confirming to ISO 9906 suitable to handle tubidity upto 600 PPM of Groundfos/KSB/kirloskar/ Sabar/ Johnston/ Crompton/ Kalama make instead of clean water pump conforming to BIS:8034 for 6000 PPM or latest suitable for lifting waer (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/ suitable alloys directly coupled to squirrell case electric induction motor of same make as ( manufacturer standard) conforming to BIS: 9283- 1979 (latest with upto date ammendments) and totally water proof for submersible duty, isolated from the pump by intemediate csng with double machanical seal in oil chamber, grease packed lubricated & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given as blow:- (2 Set of 10 HP). a) Discharge (Q) 18.52 LPS or 66.67 m3/hrs. (b) Total dynamic heads:- 19.43 mtr. (c) LWL in sump well (h):- 652.50 mtr. (d) Shaft Level:- 652 mtr. (e) Level of discharge point:- 667 mtr. (f) Suction Lift:- +ve. (g) Discharge Head:- 15 mtr. (h) Static Head:- 15 mtr. Rising Main:- (a) Length :- 100 mtr. (b) Dia:- 200mm. (c) Pumping Hours:- 20 hrs. (d) Altitude of nstallation above MSL:- 650 mtr. (e) Characterstics of water:- Raw water with turbidity upto 600 PPM.
Supply , Installation, Testing and Commissioning of Star Delta Starter panel for submersible pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the rating 10 HP through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators.Make: Aarmation Electric Private Limited/MAS/ELLES/Adlec.
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for 10HP starter.
Voltage Protection device to protect panel from over voltage and under voltage.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi function meter indicating dofferent parameters like current , Voltage, KWH, PF, THD etc with RS 485 communication Make Aarmation Elactric/MAS/Elle.
Main incomer MCCB/MCB of suitable capacity of L&T/ Schnieder/ABB make on the fedder for pumping set confirming to BIS 2516-1985(Latest edition).
Individual Starter incomer MCCB/MCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS2516-1985(Latest edition).
LED three phase indicating lamps complete with toggled switches for individual motors conforming to BIS 3452(Part I & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring , Power capacitor, Cooling fan 230VAC, Contorl terminal, Bus Bar, i.e. Bolt, insulator, etc.
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
Control Transformer to provide a stable control voltage to safegaurd the control circuit of all the components from the voltage surges and spikes.
Providing doule flanged cast steel sluice valve, ASA-150 of Leader/BHEL/ Kirlosker/ Kilburn/ GLEd/ Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing doule flanged cast steel sluice valve, ASA-150 of Leader/BHEL/ Kirlosker/ Kilburn/ GLEd/ Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure 21 kg/cm2 as per BIS standerds with upto date ammendments)
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/PREGA/ precision make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per IS:2373:1981 with upto date ammendments.
Installation of all the items apparing as per the schematic drawing.
Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of siemens /GLOSTER/IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles,flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.
(a) Motor side (From switch to starter and starter to motor)
(b) Supply side (From Meter of HPSEB to bus bar and switch)
Supply of horizontal spindle horizontal radial split casing / and suctions (back pull out arrangement) Single / double / multistage centrifugal pumps or combination of pumps in series / parellel of KSB / Mathur & Platt / Jyoti / Kirloskar / BE / Maxflow / Beaconweir Sabar make conforming to BIS 5659-1970) pump (Latest with upto to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned characteristics with bronze / Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling of electic induction motor/motor of standard make such as Kirloskar / NGEF / Cromption / Siemen / Jyoti / BHEL / GEC / ABB conforming to BIS 325-1978) read as BIS 900- 1972 and IS:12615:2011 with IE-2 specifications (latest upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the data given as below :- (2 set of 50 HP) a) Discharge (Q) 18.52 LPS or 66.67 m3/hrs. (b) Total dynamic heads:- 110.96 mtr. (c) LWL in sump well (h):- 664 mtr. (d) Shaft Level:- 663 mtr. (e) Level of discharge point:- 765 mtr. (f) Suction Lift:- +ve. (g) Discharge Head:- 102 mtr. (h) Static Head:- 102 mtr. Rising Main:- (a) Length :- 500 mtr. (b) Dia:- 200mm. (c) Pumping Hours:- 20 hrs. (d) Altitude of nstallation above MSL:- 660 mtr. (e) Characterstics of water:- Clear water with turbidity upto 150 PPM (f) Tempeture:- 25 detree centigrade.
Supply, Installation, Testing and Commissioning of Soft starter panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. 1 working & 1 stand by each of the rating 50.00 HP .through Star delta Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators.. Make: Aarmation Electric Private Limited/MAS/ELLES/Adlec
Soft starter and Mains power Contacts of required ratings as per type-2 co-ordination for 50HP starter.
Voltage Protection device to protect panel from over voltage and under voltage.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi function meter indicating dofferent parameters like current , Voltage, KWH, PF, THD etc with RS 485 communication Make Aarmation Elactric/MAS/Elle.
Main incomer MCCB/MCB of suitable capacity of L&T/ Schnieder/ABB make on the fedder for pumping set confirming to BIS 2516-1985(Latest edition).
Individual Starter incomer MCCB/MCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS2516-1985(Latest edition).
Three phase indicating lamps complete with toggled switches for individual motors conforming to BIS 3452(Part I & II) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring , Power capacitor, Cooling fan 230VAC, Contorl terminal, Bus Bar, i.e. Bolt, insulator, etc.
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
Control Transformer to provide a stable control voltage to safegaurd the control circuit of all the components from the voltage surges and spikes.
Independent control panel with switch fuse unit and fuses of suitable amperage to eliminate the Kit Kat fuses of HPSEB make siemens/ Schnieder/ L&T.
Providing double flanged CI sluice valve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date amnmendments)
Providing doule flanged cast steel sluice valve, ASA-150 of Leader/BHEL/ Kirlosker/ GLEd/ Kilburn Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing doule flanged cast steel reflux valves class , ASA-150 (with nominal seat pressure 21 kg/cm2) of Leader/BHEL/ Kirlosker/ Kartar/ Kilburn/ GLEd/ Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing doule flanged cast steel reflux valves class , ASA-150 (with nominal seat pressure 21 kg/cm2) of Leader/BHEL/ Kirlosker/ Kilburn/ GLEd/ Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standerds with upto date ammendments)
Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/PREGA/ precision make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with upto date ammendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per IS:2373:1981 with upto date ammendments.
Installation of all the items apparing as per the schematic drawing.
Providing and fixing double flanged MD/GI piping work (Layout to be approved by the Engineer in charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends,tees,reducers. Increasers with companions flanges matching with the relavant specifications of the accessories including rubber/asbestos gasket of minimum 3mm thickness as per IS:2712:1979 and required number of nuts and bolts as per IS:1364:1983, The pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times tatal head stipulated under item No.12. The size of the various components to be as under:
a) Suction pipe : One dia higher then the suction of pump offered and suitable to keep the velocity of flow from 1 to 1.5M/second in the suction pipe
b) Delivery pipe: One dia higher then the delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/second in the delivery pipe.
c) Common header: One dia higher then delivery of pump will extend upto 5meters from the outer wall of the pump house in the direction to be jointed .
Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of siemens /GLOSTER/IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles,flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.
(a) Motor side (From switch to starter and starter to motor
(b) Supply side (From Meter of HPSEB to bus bar and switch)
Providing and fixing double loop earthing with GI plate 600mmx600x3mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Errection of all equipments i/c cost of tees, bends taper & any other fitting required as per site conditions & as per directions of Engineer-in-Charge.
Low cost automation.
PLC (Programmable logic cotroller) with appropriate digital and analog imputs and outpurs to give automatic command to Star Delta Starter Panel/ Energy saving Variable Frequency Starter Panel Make Aarmation Electric/ Bechoff Automation/ Rockwell Automation/ JSV Approved.
Electronic relay card 8 chaneel.
SMPS 4.5 /anos ti energise PLC system.
HMI (Human Machine Interface) 7" display for moniter and controlling of centrifugal pumps Make : JSV Approval/ Bechoff Automation/ Rockwell.
Control MCB for Automation system.
Level sensor to indicate the water level of tank remotely.
Shielded Data Cable for communication of level sensor with PLC.
DHANANJAY SINGH SLATHIA
KUSHAL SINGH RAGHAV
M/S THAKUR ELECTRICAL & HARDWARE STORE
HEM RAJ
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .