| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC | ₹4.3 L | L1 | Accepted-AOC Financially lowest |
| 2 | L2₹4.3 LRejected-Finance | ₹4.3 L | L2 | Rejected-Finance Financially not lowest |
| 3 | L3₹4.7 LRejected-Finance T C 17 250 CHADIYARA ROAD POOJAPPURA TRIVANDRUM KERALA 695012 | THIRUVANANTHAPURAM | KERALA | 695012 | ₹4.7 L | L3 | Rejected-Finance Financially not lowest |
| 4 | L4₹5.2 LRejected-Finance 3 333 F M P ARCS VENGACHUVAD VAZHAKULAM P O MUVATTUPUZHA ERNAKULAM KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | ₹5.2 L | L4 | Rejected-Finance Financially not lowest |
| Sl No | Description | Qty | Unit | Linsta Services L4 | RAJENDRAN NAIR S L1 | AKSHITH ELECTRICALS L3 | AJESH KK L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
GroupC | 32 | Point | 2,200 ₹70,400 | 1,500 ₹48,000 | 1,200 ₹38,400 | 1,700 ₹54,400 |
| 2.00 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
GroupC | 32 | Point | 1,300 ₹41,600 | 1,000 ₹32,000 | 800 ₹25,600 | 900 ₹28,800 |
| 3.00Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. | |||||||
| 3.10 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire | 92 | metre | 350 ₹32,200 | 275 ₹25,300 | 210 ₹19,320 | 130 ₹11,960 |
| 3.20 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire | 50 | metre | 410 ₹20,500 | 350 ₹17,500 | 240 ₹12,000 | 160 ₹8,000 |
| 3.30 | 2 x 4 sq.mm + 1 x 4 sq.mm earth wire | 30 | metre | 500 ₹15,000 | 375 ₹11,250 | 310 ₹9,300 | 210 ₹6,300 |
| 4.00 | Supplying and fixing suitable size GI box with modular plate and cover infront on surface or in recess, including providing and fixing 3pin 5/6A modular socket outlet and 5/6A modular switch, connections etc. as required. | 15 | Each | 720 ₹10,800 | 750 ₹11,250 | 800 ₹12,000 | 850 ₹12,750 |
| 5.00 | Supplying and fixing suitable size GI box with modular plate and cover infront on surface or in recess, including providing and fixing 6pin 15/16A modular socket outlet and 15/16A modular switch, connections etc. as required. | 2 | Each | 870 ₹1,740 | 800 ₹1,600 | 950 ₹1,900 | 950 ₹1,900 |
| 6.00Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. | |||||||
| 6.10 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) | 32 | Each | 4,180 ₹1.3 L | 3,500 ₹1.1 L | 3,650 ₹1.2 L | 4,000 ₹1.3 L |
Tender Value
₹4.8 L
EMD Value
₹9,677
Closing Date
19 Jan 2026, 4:00 pmClosed
PROJECT ENGINEER CUM ESTATE OFFICER (I/C)
IISER TVM MARUTHAMALA PO VITHURA
Electrical works for Central Dining Hall-3 at IISER, Thiruvananthapuram
2026_IISRT_893503_1
IISERTVM/EO/EM/240/41/2025-26
Open Tender
Electrical Works
30 days
IISER THIRUVANANTHAPURAM
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹9,677
23 Feb 2026
12 Jan 2026
20 Jan 2026
13 Jan 2026
19 Jan 2026
13 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GroupC
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. GroupC
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
2 x 4 sq.mm + 1 x 4 sq.mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover infront on surface or in recess, including providing and fixing 3pin 5/6A modular socket outlet and 5/6A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover infront on surface or in recess, including providing and fixing 6pin 15/16A modular socket outlet and 15/16A modular switch, connections etc. as required.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)18- 22 Watt
Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty.
22 watt System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
Supply and installation of following exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as required.
300mm Sweep industrial heavy duty exhaust fan with bird guarded louver.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Approvedmateriallist.pdf
Additional Documents • 4.57 MB
GCC2023.pdf
Tender Documents • 23.40 MB
BOQ_939185.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid