Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹22.4 L+₹3.6 L (19.0%)Rejected-Finance 205L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹23.7 L+₹4.9 L (26.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹25.0 L+₹6.1 L (32.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
SPL REPAIR TO BLDG NO 53 T 27 AND PROVN OF SENTRY POST AND TOILET CUM BATHROOM UNDER AOR OF GE SAMBA
2021_MES_479382_1
GE/SMB/T-35/2021-22
Open Tender
Civil Works
Item Rate
180 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹50,000
Yes
6 Jan 2022
21 Oct 2021
20 Nov 2021
21 Oct 2021
18 Nov 2021
5 Nov 2021
21 Oct 2021 - 23 Oct 2021
60 days
Amount
Demolition of plain cement concrete in ground floors or paving n.exc 15 cm thickness (Below or above ground level) complete all as specified and directed.
Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and directed.
Taking down cement plaster/Dado(terrazzo) on brick/concrete or stone walls, ceiling, etc, including raking out joints, hacking for key, scrugbbing down with water etc, complete all as specified and directed.
Dismanting of floor hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed.
Brick work with sub class 'B' burnt bricks straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified and directed.
Plain cement concrete type B1 1:2:4 in lintels upto 1.5m clear span ,cills ,steps;seismic and other similar bands ,plinth courses, coping ,parapets and railings upto 60cm in height. complete all as specified and directed.
Rendering 15 mm thick on brick work or concrete surfaces in two layers ( first layer 10 mm thick CM 1:6 and second layer 5 mm thick CM 1:4 mixed with WPC) finished even and smooth without using extra cement, complete all as specified and directed. ( WPC shall be measured and paid separately)
Rendering 15 mm thick cement plaster in cement mortar 1:4 on on brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed.
Coloured ceramic tiles (1st quality) 8 to 10 mm thick(square/rectangular joint free) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortor 15mm thick in CM 1:6, complete all as specified and directed
Coloured ceramic tiles (1st quality) 8 to 10 mm thick(square/rectangular joint free) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surface, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including layer of mortor 10 mm thick in CM 1:4, complete all as specified and directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness including cover fillets, complete all as specified and direted.
4mm thick designer ceiling board in ceiling of size 595mm x 595mm fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exc 1.5 sqm but not exceeding 4 square metre each, complete all as specified and directed.
Pressed steel frames 125x60mm for doors made out of 1.25 mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed.
Pressed steel frames 105x60mm for doors made out of 1.25 mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed.
35mm thick, IInd class H.W.Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated , complete all as specified and directed.
Glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); kiln seasoned and chemically pressure treated, complete all as specified and directed
Stainless steel wire cloth,0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
Steel window factory made with tubular frame of size 79mmx39mm 16 gauge double door (one side glazed shutter & other side gauged shutter with sash bar), rectangular tubular frame including box type hinges with steel handles, steel peg stays complete with glazing bars dovetailed or welded complete incl 10mm MS Squre as grill/guard bars, complete all as specified and as directed.
Aluminium alloy, anodised sliding door bolts(250mm long) with hasp,staples( bolt type) and fixing clip of sheet,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed ,complete all as specified and directed.
Aluminium handle 150 mm long cast type anodised, complete all as specified and directed
Aluminium tower bolt 200 mm long, anodised barrel tower bolts of extruded section complete all as specified and directed.
Aluminium tower bolt 150 mm long, anodised barrel tower bolts of extruded section complete all as specified and directed.
Aluminium floor door stopper (150 mm long) of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed
M.S. helical door spring (150 mm long) including roller and roller plate complete all as specified and directed
Sheet glass, ordinary quality 4.00 mm thick and glazing with oil putty in square not exceeding 0.5 sq m in each pain, fixed in repair, complete all as specified and directed.
Preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of newly plastered surfaces of walls etc and applying two coats of cement based paint over one coat of primer , complete all as specified and directed.
Preparation of old surfaces of walls etc and applying one coat of cement based paint , complete all as specified and directed.
Complete removal of existing old treatment on wall surface all as specified and directed.
Preparation of plastered surfaces of walls and applying two coats of oil bound distemper over a coat of wall care putty , complete all as specified and directed.
Cement concrete type D-2, 1:4:8(40mm graded crushed stone aggregate) as in foundations,filling and mass concrete, sub base floor, complete all as specified and directed.
Pre-polished chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 20 mm thick cement screed bed in CM 1:6 complete all as specified and as directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
PCC 1:3:6 type C-2(using 20 mm graded crushed stone aggregate), 75mm thick as in plinth protection finished even and smooth without using extra cement laid in bays not exc. 2.00m and joints filled with bitumen sand mastic with ratio (1:3 ) complete all as specified and directed.
20mm dia dropery curtain rod mild steel powder coated with suitable brackets and end caps fixed in repairs.complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard and dence soil, complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth: for foundation etc or for shafts,wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard & dence soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm, hard & dence soil, complete all as specified and directed.
Removng excavated material (soil) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point,complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
RCC M-25 (Desgin mix) as in foundation, footing, foundation beams, plinth beams, bases of columns etc complete all as specified and directed.
RCC M-25 (Desgin mix) as in Columns, pillars, piers, posts, struct etc complete all as specified and directed.
RCC M-25 (Design mix) as in beams, cantilevers etc complete all as specified and directed.
RCC M-25 (using 20 mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajjas. etc complete all as specified and directed.
RCC M-25 (using 20 mm graded stone aggregate) as in fins, facias, railing parapet etc complete all as specified and directed.
RCC M-25 (using 20 mm graded stone aggregate) as in stairways (except spiral staircases) including steps, string pieces, carriage etc complete all as specified and directed.
RCC M-25 (using 20 mm graded stone aggregate) as in walls, retaining walls, basement walls of any thickness above top of footings etc complete all as specified and directed.
Use and waste formwork to faces of walls, retaining walls, abutments, parapets and staircase, railings and similar works, complete all as specified and directed.
Formwork to side of foundation, footings, bases of column, raft and raft beams, plinth beams and similar work etc including fair finished surface complete all as specified and directed.
Formwork to side of pillars, posts, struts, piers, columns and stanchions etc including fair finished surface complete all as specified and directed.
Formwork to side and sofit of floor and roof beams and lintels etc including fair finished surface complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, chajjjas, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) incl fair finished surface complete all as specified and directed.
Formwork to staircases with sloping or stepped soffits including riser and stringers etc including fair finished surface complete all as specified and directed.
Sand cushioning to under floors or in foundations including watering and consolidation complete all as specified and directed.
Hard core (broken stone) of gauge n.exc. 63mm, deposited, spread and levelled in layers n.exc. 15cm thick watered to a true surface, complete all as specified and directed.
PCC 1:2:4 Type B-2 150 mm thick ( using 20mm graded crushed stone aggregate) as in sub base of floor, complete all as specified and directed.
Machine cut kota stone slab flooring 20-25mm thick over and incl 20mm thick cement screed base in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Kota stone floor 18-20 mm thick and including 10mm thick CM 1:4, as in riser of steps, skirting, dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Rendering 5 mm thick on ceiling surfaces in CM 1:3 and finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 5 mm thick on column and RCC wall surfaces in CM 1:4 and finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
Preparation of old plastered surfaces of ceiling and applying three coats of white wash , complete all as specified and directed.
Steel door including projecting type hinges, steel handle, complete with glazing bars, devetailed or welded, complete all as specified and directed.
DPC 40mm thick to horizontal or vertical surfaces including necessary formwork PCC 1:2:4 Type B-0 using WPC @ 3% of cement by weight, complete all as specified and directed. Note- WPC should be measured and paid separately.
Brick work with sub class 'B' burnt bricks straight or curved on plan exc. 6 m mean radius built in half brick thick walls in CM 1:4 complete all as specified and directed.
PCC 1:3:6, 75 mm thick,Type C-2 (using 40mm graded crushed stone aggregates) as in sub base in floor, drain surface etc, complete all as specified and directed.
PCC M-15 Type B-1 25 mm thick ( using 20mm graded crushed stone aggregate) as in sub base floor, complete all as specified and directed.
Non skid coloured ceramic tiles (1st quality) 7 to 8mm thick(square/rectangular joint free) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortor 15mm thick in CM 1:6, complete all as specified and directed
Glazed coloured ceramic tiles (1st quality) joint free in vertical surfaces of wall of size 450x350x7mm/350 x250 x 7mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 on brick /concrete surfaces complete all as specified and directed .
G.I. pipe 15mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling and laid in floors complete all as specified and directed
Factory made PVC internal UPVC (rigid) door frame of the size 50mm x 95mm with a wall thickness of 5mm, made out of extruded 5mm thick, PVC sheet of density 600kgs/cbm manufactured by an ISO-9000 certified company, mitre cut at two corners and joined with 4 nos of 150mm long brackets of 15mm x15mm M.S. square tube of 19 guage through out the frame .The door frame shall be fixed to the wall using 65/100mm long M.S. screws through the frame by using anchor fasteners.A minimum of 4 nos .of screw to be provided for each vertical member & minimum 2 nos. for horizontal members etc. complete all as specified and directed.
Factory made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, complete all as specified and directed.
Butt hinges 100 mm medium weight stainless steel complete all as specified and directed
Steel ventilator with top hung shutter including hinges, steel peg stay , complete all as specified and directed.
Figured sheet glass , ordinary quality 4.00 mm thick and glazing with oil putty in square not exceeding 0.5 sq m in each pain complete all as specified and directed.
Vitreous china ,Squatting pan 'Orissa' pattern size 580x440mm white with integral foot rest including all joints and making good to the floor etc ,complete all as specified and directed.
Cement concrete 1:7:12 type F-2 (using 40 mm graded stone aggregate) as in sunken filling , complete all as specified and directed
PVC valveless, 10 ltrs, syphonic action type, dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, fixed in repair, complete all as specified and directed
Stop valve 15mm bore,cast copper alloy screwed down,high pressure, screwed both ends for iron pipe or unions( concealed type)complete all as specified and directed
Stop valve 20 mm bore,cast copper alloy screwed down,high pressure, screwed both ends for iron pipe or unions( concealed type)complete all as specified and directed
Rotational moulded polye- thylene water storage tanks of capacity 1000 ltrs Three layered ISI marked, white colour (cylindrical vertical with closed top) hoisted and fixed in position including all necessary connections all as specified in SSR Part I including dismantling of existing water storage tank, complete all as specified and directed.
20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. complete all as specified and directed.
C.P. Bib taps, long shank(Fancy type) 15mm bore cast copper alloy ,screwed down,screwed for iron pipe or brass ferrule complete all as specified and directed
C.P. Angle valve (fancy type) 15mm bore,cast copper alloy screwed down,high pressure, screwed both ends for iron pipe or unions complete all as specified and directed
PVC connection 15mm dia, 450mm long with brass nut complete all as specified and directed
Extra for forming fair finished drain or channel 45 cm inner grith in cement concrete with fair finished, complete all as specified and directed.
PVC (SWR) pipes 150mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
Concrete bed to drain pipes 150 mm bore including packing under and completely surrounding pipe with concrete after they are laid and tested in cement concrete Type D-2 1:4:8, complete all as specified and directed.
PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
PVC (SWR) 110mm bore bends any radius, complete all as specified and directed.
PVC (SWR) 75mm bore bends any radius, complete all as specified and directed.
PVC (SWR) 110mm bore bends any radius with access door, complete all as specified and directed.
PVC (SWR) 75mm bore bends any radius with access door, complete all as specified and directed.
Construction of Septic tank for 10 users all as per DRG NO CEPZ/C-TD/13/13 Sheet 1/5 to 5/5 and as specified below :- Earth work in ordinary soil, Hard core of stone, Brick work in CM (1:4), PCC (1:3:6) Type C-1 in base, RCC (1:1.5:3) Type A1 Nominal mix in RCC Members, Brick aggregate 80mm to 20 mm gradded, Inlet pipe etc shall be of 150 mm dia SGSW pipe Grade 'A', 15 mm plaster in CM (1:6) finished even & fair internally, removing surplus materials to a distence exc. 25.0 m but n.exc. 500 m, rest all as per Drg. (No other items of BOQ is applicable in this item)
Construction of Soakage well 2400 mm internal dia x 3000 mm deep all as per DRG NO CEPZ/C-TD/13/13 Sheet 1/5 to 5/5 and as specified below :- Earth work in soft / loose soil, Hard core of stone, Brick work in CM (1:4), PCC (1:3:6) Type C-1 in base, RCC (1:1.5:3) Type A1 Nominal mix in RCC Members, Brick aggregate 80mm to 20 mm gradded, Inlet pipe etc shall be of 150 mm dia SGSW pipe Grade 'A', 15 mm plaster in CM (1:6) finished even & fair internally, removing surplus materials to a distence exc. 25.0 m but n.exc. 500 m, rest all as per Drg. (No other items of BOQ is applicable in this item)
Taking down steel/asbestos cement, corrugated or semi-corrugated sheets in roof, wall etc, complete all as specified and directed.
Dismantling timber scantling 40 sq cm and over in section framed work in any position. complete all as specified and directed .
Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws, complete all as specified and directed.
Roof trusses (framed), trussed, purlins, rafters, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, MS plate, welding, bolts etc conforming to Fe-290 (Gde E-165). complete all as specified and directed.
Preparation of new plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489 :2004, alkali & fungle resistence, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.
Preparation of old plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489 :2004, alkali & fungle resistence, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces, complete all as specified and directed.
Preparation of old surfaces of walls and applying two coats of white wash, complete all as specified and directed.
Rubbing , grinding and polishing the existing terrazzo topping / kota stone flooring and skirting, complete all as specified and directed.
Supply only integral water proofing compound liquid, complete all as specified and directed
Taking down old unserviceable aluminium point wiring (light, fan, socket , power socket and bulk head fittings) from PVC/metallic conduit,on surface wiring, on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc complete all as specfied and directed.
Point wiring for light / fan controlled by one switch with 1.5 sq mm single core PVC insulated unsheathed multistranded copper conductor FRLS with in and including PVC concealed conduit having thickness not less than 1.8 mm with all fittings including anodised pressed steel sunken box having thickness not less than 2mm with 3mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed piping including insulation test of point wiring and making good disturbed surfaces area and white wash/colour wash to matching with the existing colour and point wiring connection will be tapped from nearest point and complete all as specified and directed. Note: (a) Insulation test of point wiring (b) Colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
All as per srl item No 116 above but for 3 pin 5 amps independent board complete all as specified and directed.
All as per srl item No 116 above but for 3 pin 5 amps same board complete all as specified and directed.
Point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) with in and including PVC casing & caping with all fittings including anodised pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to comman earth dolly including cutting chiseling for concealed piping and making good disturbed surface area and white wash /colour wash to matching with the existing colour complete all as specified and directed.Note: (a) Insulation test of point wiring (b) Colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Switch piano flush type single pole, 5 Amp, one way, AC 230 volts etc complete, all as specified and directed.
Switch piano flush type single pole, 15 Amp, one way, AC 230 volts complete, all as specified and directed.
Socket outlet 3 pin 5 amps flush type complete all as specified and directed.
Socket outlet multipurpose 2 in 1, 6 pin 6 and 16 amps controlled by one switch flush type universal .
Ceiling rose 65 x 50mm three terminals complete all as specified and directed.
Ceiling fan regulator electronic type 5 stage speed variation,socket type is size, ISI marked complete all as specified and directed.
Lamp holder/batton holder/angle holder insulated body(Metal ring) with back bakelite plate suitable for batten fittings.
LED tube light fitting 20 watt, 230 volt,box type complete bipin holders, connector,mounted on PVC block and retro LED rod of 20 watt with aluminium heat sink & polycarbonate diffuser having high efficacy (single side connection) complete with all accessories internally pre wired batten(single side connection) and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed,LED tube rod ,make :Havells ,cat part no:REGALBATTENT5UPTO1X22WSSBSWH and LED tube light batten ,make :Havells , Cat Part No :PHOTONULTRAE2.01213T8SSTL20WLED865SPC or technocommerically equivalant make of Crompton/Philips Note: (i) Contractor shall produce LM 79 & LM 80 test report form OEM owned NABL accredited laboraory. (ii) Contractor shall give gurantee of complete fitting/ fixtures for minimum of 5 years form the date of completion. (iii) Contractor shall conduct the inspection of company representative at site before installation of fittings/fixtures at no extra cost. (iv) Contractor shall arrange 70 % material at site for approval of GE before incorporation in the work.
Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon Bulk head 10 watt back-lit LED luminaire comprissing of high brightness LEDs Cat Part No HEXAFT10WLED857SSYMBOPC of Havells or technocommerically equivalent to Philips/Syska/Crompton.
Recess mounting LED 2X2 luminaire light fittings complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of 1.5 sqmm with suitable size of 36 watt, complete all as specified and directed. Make- Cat part No. STARTO2X2PLR36WLED840MOD of Havells or technocommerically equivalent make of Philips/ Crompton.
Sheet metal enclosures distribution boards, double door ,VTPN, 415 volts 4 ways (one incoming three phase & twelve out goings single phase )for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA=01 NO (for incoming ) (b) MCB SP 06- 40 amps = 4 Nos (for outgoings) . ( Note :- (i)The DB shall be VTPN series of Make : Schneider ,Cat Part no: A9HVD04L or equivalent make of L&T/ ABB . (ii) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble properly crimped.(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. (vi) cutting chasing shall be part of job at no extra cost .
Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with SP MCB 32 Amps, 240 volts AC, complete all asspecified and directed.
Sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 08 ways complete all as specified and directed.
Sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 04 ways complete all as specified and directed.
Sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 12 ways complete all as specified and directed.
MCB SPN 63 amps 240 Volt 'B' series complete all as specified and as directed.
MCB SPN 32 amps 240 Volt 'B' series complete all as specified and as directed.
MCB SP 6-32 amps 240 Volt 'B' series complete all as specified and as directed.
Taking down the unservicable /brunt sub main wiring from wooden batten and provisioning of submain wiring in and including PVC conduit 1.8 mm thick ,20 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 4 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 4 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 4 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) Colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Taking down the unservicable /brunt sub main wiring from wooden batten and provisioning of submain wiring in and including PVC conduit 1.8 mm thick ,20 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 6 sqmm(FRLS) and one run of PVC insulated,unsheathed multistranded copper conductor 6 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) Note: (a) Insulation test of point wiring (b) Colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is included in the quoted rate. 2. Soil should be free from stone, boulders, aggregate, gravels etc.
Wall mounting fans complete with blades and accessories, 230 volts, 450mm sweep, 2100 RPM Min air delivery 105 CFM with service, complete all as specified and directed. Make- Bajaj or technocommerically equivalent make of Khetan/ Crompton.
House sevice bracket hook type complete with 3.0 mtr long GI pipe 40 mm dia medium grade two nos 900 mm bends M.S. hook and stay or guy, complete all as specified and directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor cable size of 10 sqmm 2 core served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire , one twin core cable flat or circular, complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
s k construction co
SIDDAHANT ENTERPRISES
M/S NAGAR BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .