| 1 | L1₹14.4 LAccepted-Finance JOY VILA MRA 230 MOOLAVILKOM JUNCTION VANCHIYOOR TRIVANDRUM 695 035 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695035 | L1 | Accepted-Finance Admitted Found Reasonable for Acceptance | |
| 2 | L2₹15.3 L+₹92,845.20 (6.44%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L2 | Rejected-Finance Rejected L1 being accepted |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
19 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2022_MES_530306_2
GE (ARMY) TVM 9466/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹30,000
Yes
10 Oct 2022
27 Aug 2022
26 Sept 2022
27 Aug 2022
19 Sept 2022
5 Sept 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation of pole etc and getting out in soft/loose soil complete all as specified and directed.
All as per item 1 here-in-before but exceeding 1.5 M depth for foundation of pole etc and getting out in soft/loose soil complete all as specified and directed.
Cushioning of UG cable with using riddled soil obtained from excavation including returning filling , spreading leveling, watering and well ramming in layers not exceeding 25cm using riddled soil / soil obtained from excavation after the pipes/cables/fittings are laid/fixed jointed and tested complete all as specified and directed. Note:- Extra care shall be taken while filling around UG cable
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5 mtr from the starting point all as specified and directed.
M&L for PCC (1:3:6) type C-2 with using 40mm grade stone aggregate as in foundation of steel tubular poles and stay with necessary form work as required complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 with using 20mm grade stone aggregate as in coping of steel tubular poles with necessary form work as required complete all as specified and directed.
Dismantling of UNSV / broken electric pole of any size and type with disconnecting all connections, demolition of concerted foundation including excavation earth work as required and removing the same from site complete all as specified and directed.
Supply and erection of steel tubular swaged poles 9.0 meter long, type 410 SP-31 in true vertical position complete with cast iron base plate, final taper plug, bolts, nuts and screws pole cap etc conforming to IS-2713(Part-1 to 3)1980 including painting two coats of black bituminous paint throughout internally, and externally up to the planting depth and the remaining portion of the exterior shall be painted with two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces complete all as specified and directed.
Dismantling of unserviceable/perished ACSR conductor of any size from LT over head lines and removing the same from site complete all as specified and directed.
S & F aluminum conductor steel reinforced (ACSR) any size as directed on overhead LT electric line with stretching and tensioning with reqd span sag and binding the conductor with pin/shackle insulator with aluminum binding wire not less than 2mm dia complete all as specified and directed.
Stretching / restringing only ACSR conductor obtained from Ser Item No 09 in position on LT over head lines of any size,type, span length with permisiable span sag and binding with pin/shackle insulator with new aluminum binding wire not less than 2mm dia complete all as specified and directed.specified and directed.
Dismantling of rusted/corroded earth/guard wire of any size and removing unserviceable GI wire from site complete all as specified and directed.
S & F galvanized wire 3.15 mm dia as in continuous earth wire/guard or cradle wire made to required shape fixed on poles for LT feeder including binding the same with new GI binding wire not less than 2mm dia complete all as specified and directed.
Dismantling of rusted/corroded cross arms fixed on LT poles and removing unserviceable cross arms from site complete all as specified and as directed.
S&F cross arms made out of mild steel channel or angle section of reqd size and shape including clamp back plate with bolts, nuts, washers drilled for insulator bolts, welding, binding cold or hot in any shape or size as directed and painted with two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces complete all as specified and directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as required and removing the same from site complete all as specified and as directed.
S&F stay assembly complete with all accessories and stay clamps all as shown in electrical plate No 1 of SSR Part I with using stay rod of 16 mm dia 1.8 mtr long and stay plate galvanized steel 23cmx23 cmx6mm thick complete all as specified and directed. (Loop type insulator, excavation and earth work, concrete foundation and stay wire, stay clamps) shall be measured and paid separately under relevant items of this Sch ‘A’)
S & F galvanized stay wire (stay strand) of size 7/3.15 mm with properly tightening the same complete all as specified and directed.
Taking down existing unserviceable street light fittings, including necessary disconnection of electric connection and removing from site complete all as specified and directed.
S & F LED street light lumination new generstion energy saving & anvironmental friendly long life versatile pressure die -cast aluminium IP65 road way with high power LED 35 WATT as light source complete all as specified and directed. Make Havells / philips/crompton
Taking down old unserviceable street light bracket from pole alongwith clamps nut & bolt complete all as directed.
S&F street light bracket of length 1.20 meter made of GI pipe medium grade 25 mm bore bent to shape to fixed on LT poles including taking MS clamps nuts bolts etc and out old u/s bracket complete all as specified and directed.
Dismantling of unserviceable insulators of any size and type from LT overhead lines complete all as specified and directed.
S & F pin type insulator porcelain vitreous, white, brown or green including of size 100 mm height and 65 mm dia for 1100 volt grade one galvanized mild steel spindle two galvanized iron washer and one galvanized iron nut complete all as specified and directed.
S&F shackle type porcelain vitreous white, brown or green insulator of size 75mm height, 90mm dia (maximum) including mild steel straps of section 31mmx3mm, washers, 12mm dia insulator bolt and nut suitable for working pressure 1100 volts grade complete all as specified and directed.
S&F loop type insulator vitreous porcelain white, brown or green large size with overall dimensions 90 x 140mm and clearance of hole 25.5mm complete all as specified and directed.
M&L for preparation old painted surface of cement concrete poles of any size from pole coping to top of pole including struts cross arms clamp etc and painting with two coats of approved colour of aluminium paint on cross arms over one coat of red oxide primer and two coat of apex ultima on cement poles and numbering of poles as directed with black synthetic enamelled paint complete all as specified and directed.
M/L for earthing with galvanized steel earth plate 60cm X 60cm X 6 mm thick, buried directly in ground(earth pit not less than 2.25 mtr deep below ground level) with the top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth plate surrounded by packed layers of coal dust and common salt 15 cm thick all around top and bottom all as shown in electrical plate No 5 connected to pole all as directed including PCC (1: 3:6) type C1 earth pit, cast iron pit cover, funnel with wire mesh,watering pipe 20mm dia light grade grade,1.5mtr long and 15mm bore light grade from earth plate to pole upto the height of 3mtr as protection pipe fixed with 40x3mm flat iron clamps and GI wire connected to earth wire on OHL and testing on completion including excavation earth work and disposal of surplus soils including takingout old earthing complete all as specified and directed.
Taking down unsevicable XLPE insulated armoured cable any size complete all as sepcified and directed
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 95 Sqmm, 3.5 core complete all as specified.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 50 Sqmm, 3.5 core complete all as specified and directed.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 35 Sqmm, 3.5 core complete all as specified and directed.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 25 Sqmm, 3.5 core complete all as specified and directed.
Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 16 Sqmm, 4 core complete all as specified and directed.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 2 core x 4 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 2 core 6 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supply and fix in repairs MCCB 4 pole 400 Amps 415Volt 50Hz breaking capacity 36KA adjustable type including taking down existing unserviceable complete all as specified and directed.
Supply and fix in repairs MCCB 4 pole 250 Amps 415Volt 50Hz breaking capacity 36KA adjustable type including taking down existing unserviceable complete all as specified and directed.
Supply and fix in repairs MCCB 4 pole 200 Amps 415Volt 50Hz breaking capacity 36KA adjustable type including taking down existing unserviceable complete all as specified and directed.
Supply and fix in repairs MCCB 4 pole 160 Amps 415Volt 50Hz breaking capacity 36KA adjustable type including taking down existing unserviceable complete all as specified and directed.
Supplying and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250 x 150 x 40 mm complete all as specified and directed by the Engineer - in - charge.
M&L for GI pipe light grade 50 mm dia for cable protection laid in trenches complete all as specified and as directed.
Cutting and trimming of tree branches, bushes n.exc 3 Mtr min clearance alround the overhead electric lines/guard wire and removing branches out of defence land complete all as specified and directed. Note: One metre length comprising upto 6 feeder of 2/4 conductors each shall be measured as one unit)
Removing grass and bushes growing at all electric sub stns and keep all the sub stn yards neat and clean complete all as specified and directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of the contract.
S&F cable route indicator made of CI plate of 100 mm dia and not less than 10 mm thick welded with 10mm dia, 30cm long MS rod, grouted in PCC block of size 0.2 x 0.2 x 0.3 m and writing LT cable, etc complete all as specified and directed.
JEETH CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .