Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC FIRST FLOOR FLAT NO 202 B THE COURTYARD RESIDENCY 13 A BALBIR ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹1.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.0 Cr+₹3.8 L (1.95%)Rejected-AOC 112 RADHEY SHYAM VIHAR PHASE II MURAD NAGAR GHAZIABAD UP | GHAZIABAD | UP | ₹2.0 Cr+₹3.8 L (1.95%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical 201 174 | DEHRADUN | DEHRADUN | UTTARAKHAND | - | - | Rejected-Technical Not Quailfied in PQR |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
18 Sept 2024, 5:00 pmClosed
Superintending Engineer
EDC, Chakrata, UPCL
SUPPLY, ERECTION AND COMMISSIONING OF LT ACB 800 AMP 4 POLE FOR EXISTING 400/250 KVA TRANSFORMERS AND LT MCCB FOR 100/63/25 KVA TRANSFORMERS OF 11 KV FEEDERS and REPLACEMENT OF EXISTING LINE CONDUCTOR BY AAAC AL59, 99 SQ MM COVERED CONDUCTOR OF 11 KV
2024_UPCL4_75251_1
28/EDCC/2024-25
Open Tender
Electrical Works
Turn-key
120 days
Chakrata
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,800
Executive Engineer, EDD, Vikasnagar
₹3.9 L
28 Nov 2024
2 Sept 2024
19 Sept 2024
3 Sept 2024
18 Sept 2024
3 Sept 2024
Amount
De-Centralised Material
11KV AAAC AL-59 (99 sqmm) Covered conductor (SS4240813 & SS4240814) EN 50397-1:2006 the conductor shall be stranded,round,non compacted and water tight , Non compacted shall be comply with all the requirement of EN 50397-1.2006 The stranded conductor shall be longitudionally water blocked by means of a water blocking material the semi conducting screen inner insulation and outer insulation should be extruted in one step . the outer covering insulation shall be UV stabilized tracking resistant black XLPE Capacity 300 amp
MVCC Accessories as per EN 50397-2.
11KV 90 KN Tension clamp with Bail and IPC (section Pole)
11KV Suspension ties on every Pin Insulator.
11Kv IPC for CC to CC Connection in every Section Pole
11Kv IPC for CC to Bare Connection at both end and Taping
11Kv Mid Span Jointing kit at every 500Mt. Cable drum
Supply IPC with Aluminium bail for earthing
Disc Insulator with Fitting (B&S) type for 11 KV
Holding Clamp for SP-23 with N&B.
Providing 800 amp Air Circuit Breaker type complete LT Distribution board with CT including microprocessor release IPR-1 Fixed Type 4 Pole as per (IS-13947-2 and IEC 60947-2) with panel and mounting structure as per specification for 400/250 KVA Transformers
Providing 250 amp 35 KA MF four pole with adjustable micro processor relay with earth fault digitial module case circuit bracker for 100 KVA /TF with all assesries ( Enclosure) make L&T, Indo Asian, Havell's, C&S)
Providing 125 amp 35 KA MF four pole with adjustable micro processor relay with earth fault digitial module case circuit bracker for 63/25 kVa /TF with all assesries ( Enclosure) make L&T, Indo Asian, Havell's, C&S)
Al Lug 120 (105x12)
Al Lug 240 (2x12)
MS Clamp for bottom side for ST Pole SP-23/21/33 for MCCB and 11 KV fuse set/ Line Isolator
LT XLPE Cable size 1x120 sqmm (105x66 mtr) for 100/63/25 kva Trasnformers
LT XLPE Cable size 1x240 sqmm (2x64 mtr) for 250 kva Trasnformers
Supply of GI Earthing Strip size 32x5
Earthing Rod 20x2500 mm
Labour
Cartage of SP-23 Poles from store centre to nearest road site with loading, unloading at both points. (Loading ,unloading plus carriage per poles) (0 to 100 km)
ST Pole SP-23 (Bottom Portion Hot dip)
Small Material
Head load Cartage of the following poles from road side to construction site (rates are per pole /Km including loading/unloading at both points) (0 to 1 KM)
ST Pole SP-23 (Bottom Portion Hot dip)
Small Material
Excavation of earth and erection of ST pole SP 23 single support with CC Comp
Muffing of SP 23 pole
Painting of poles with angle and channel and all steel part by one coat of red oxide primer and two coats of aluminium strip of fluorescent alternate Red and white paint 30 cm wide upto 1.5 mtrs from ground level
Fabrication of MS channel and angle
Removing of old conductor with opening of existing, jumpering and making of bundle with carriage from pit size of JE store including loading /unloading complete work
Laying, spreading, stringing and sagging of 11KV AAAC AL-59 (99 sqmm) Covered conductor (SS4240813 & SS4240814) EN 50397-1:2006 the conductor shall be stranded,round,non compacted and water tight , Non compacted shall be comply with all the requirement of EN 50397-1.2006 The stranded conductor shall be longitudionally water blocked by means of a water blocking material the semi conducting screen inner insulation and outer insulation should be extruted in one step . the outer covering insulation shall be UV stabilized tracking resistant black XLPE
Fixing of MVCC Accessories
11 KV 90KN tension clamp with bail and IPC
11 KV Suspension ties
11 KV IPC for CC to CC Connection
11 KV IPC for CC to Bare connection
11 kV Mid Span Jointing kit
Fixing of IPC with Aluminium bail for earthing
Back carriage of material from site to store (0-100 kms) including manual shifting
Cartage and Head load Cartage of material ACB, LT Cable, and other including loading and unloading from Je Store to site (0-100 kms)
Cartage of small line material from store centre Dehradun to roadsite including loading & unloading at both ends (0-100 kms)
Cartage and Head load Cartage of material MCCB, LT Cable, and other including loading and unloading from Je Store to site (0-100 kms)
Manual shifting of small line material from roadsite to worksite (0-1 kms)
Opening of 11 kV Jumper and making jumper again of section pole after complete the work
Installation of LT ACB Pannel Complete in all respect. i.e disconnection of existing cable from DTR Terminal and metering cubcial, fixing of new additional cable in ACB LT Distribution Board connecting DTR metering complete testing and commissioning of ACB connection using all lugs of proper size lugs will be provided by supplier as per required on site and narrated by Engineer in Charge of Work
Installation of Digital moulded Case Breaker on the pole with fixing of 02 nos MS Angle with the help of MS Clamp in all respect i.e i.e disconnection of existing cable from DTR Terminal, fixing of new additional cable in MCCB connecting DTR complete testing and commissioning of MCCB connection using all lugs of proper size lugs/clamp as per required site and narrated by Engineer in Charge of Work
Earthing and installation of complete chemical earthing and connection with equipment as per specifications
Fixing of Moulded case circuit braker by earth road
Laying and saging of LT XLPE Cable 1x120 sqmm
Laying and saging of LT XLPE Cable 1x 240 sqmm
AMC in First Year after one year guarantee period on MCCB 3 % on MCCB cost
AMC in 2nd year after one year guarantee period on MCCB 4 % on MCCB cost
AMC in First Year after one year guarantee period on ACB 3 % on MCCB cost
AMC in 2nd year after one year guarantee period on ACB 4 % on MCCB cost
RP INFRAPOWER PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .