| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.1 L+₹2.0 L (25.4%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹10.7 L+₹2.6 L (32.7%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹12.7 L+₹4.7 L (57.9%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹10.0 L
EMD Value
₹19,980
Closing Date
16 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
REPAIR /MAINT OF DIFFERENT TYPE OF SUMMER /WINTER APPLIANCES IN OTM/MD ACCN UNDER GE BANAR
2022_MES_514340_2
8821/40/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹19,980
Yes
20 May 2022
25 Apr 2022
18 May 2022
25 Apr 2022
16 May 2022
2 May 2022
60 days
Amount
M&L for Taking out window/Split type AC of capacity up to 2 Ton from the site and make for servicing, cleaning with air blower of fins, cleaning of condensing unit, cooling coil and evaporative coil with caustic soda mix water,taking out all dirt/sludge etc. by using pressure pump ,cleaning of air filter incl. Oiling and greasing of condensing fan motor, replacement of remote cell/battery, replacing worn out rubber,bushes/rubber packing rectification of unusual noise, replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete for smooth functioning to entire satisfaction of Engineer-in-Charge.
M&L for Topping up of refrigerant as per the existing refrigerant upto the required level for window /split type AC of capacity 1.5/2 ton all as directed by Engineer in Charge.
M&L for complete Gas charging as per the existing refrigerant up to the required level for window/Split type AC of capacity 1.5/2 Ton complete all as directed by Engineer in Charge.
M&L for Taking out defective compressor Sealed Rotary / Reciprocating unit of window AC of cap 1.5 Ton incl.cutting of copper tubing without any damage to existing other parts and Material and labour for replacement of compressor/sealed unit complete with erection of compressor in same location with suitable base,jointing of copper refrigerant pipe line,charging of gas to required level,leakage testing etc. including testing for smooth functioning. NOTE : (i)The rate quoted by the contractor shall be inclusive of all charges like transportation,fittings,etc. complete with necessary guarantee period including oiling and environment friendly gas charging , testing etc.complete all as specified and directed by Engineer-in-Charge.
All as per ser No 4 above but window type AC of cap 2 Ton complete all as specified.
All as per ser No 4 above but split type AC of cap 1.5 Ton complete all as specified.
All as per ser No 4 above but split type AC of cap 2 Ton complete all as specified.
M&L for replacement of blower bush of Split type AC having capacities of 1.5/2 Ton complete all as per the sample existing at the ground.
Supply and fix in replacement blower fan motor of suitable size for indoor type split AC of cap 1.5/2 Ton complete.
Supply and fix in replacement condensor fan motor suitable for out door type split AC of capacity 1.5/2 Ton complete.
M&L for taking out u/s blower of wnidow type AC of cap 1.5/2.00 Ton and supply and fix blower of approved make suitable for existing window type AC of cap 1.5/2.00 Ton all as directed by Engineer-in- Charge.
S&F in replacement of starting capacitor, 45/60 mfd suitable for 1.5 /2 Ton capacity window/split type AC of approved make.
S & F capacitor 5/8 mfd suitable for split / window type AC.
S&F in replacement PCB control kit of split type AC of capacity 1.5/2Ton complete all as specified and directed by Engineer-in-Charge.
S&F in replacement PCB control kit suitable for window type AC of capacity 1/ 2 Ton complete all as specified and directed by Engr-in-Charge.
S&F in replacement metal clad socket suitable for split type AC of capacity 1.5/2 Ton unit complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Thermostat (Thermal sensing bulb) suitable for split/window type AC 1.5 /2 Ton capacity of approved make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of starting and running relay suitable for window /split type AC 1.5/2 Ton capacity of approved make complete all as specified and directed by Engr-in-Charge..
S&F in replacement of over load protection relay suitable for window/split type AC 1.5 /2 Ton capacity of approved make complete all as specified and directed by Engr-in-Charge..
M&L for Taking out u/s drain out pipe of split type AC unit and supply and fix new drain out pipe of approved make complete all as directed by Engr-in-charge
Supply and fix in replacement of condensing coil of window type AC of capacity 1.5 Ton all as directed by EIC.
Supply and fix in replacement of condensing coil of window type AC of capacity 2 Ton all as directed by EIC.
Supply and fix in replacement evaporating coil of window type AC of capacity 1.5/2 Ton all as directed by EIC.
Supply and fix in replacement of evaporating coil of split type AC of capacity 1.5 /2 Ton all as directed by EIC.
Supply and fix in replacement of condensing coil unit complete out door type of split type AC of capacity 1.5/2 Ton with approved make all as directed by Engineer-in-charge
M & L for replacement of chocked copper tube of size 1/4" of split type AC 1.5/2 ton cap complete all as directed by Engineer-in-charge
M & L for replacement of chocked copper tube of size 1/2" of split type AC of 1.5 /2 ton cap complete all as directed by Engineer-in-charge
M & L for insulation coating /PVC air bubling insulation of circular dia to copper tube to upkeep the required temperature and over all protection to copper tubing of size 1/4" or 1/2" complete all as directed by EIC.
M & L for taking out water Cooler from site of any cap.and make for servicing incl. cleaning of cooling tank and condencing coil with C sine chemical mixed water, taking out all dirt , sludge deposited, incl. oiling / greasing of condensing fan motor rectification of unusual noise, replacement of minor parts such as nut/bolt washers etc as directed with writing of serial No SM/MES No. and re installed the water cooler in position complete all as directed.
M&L for Topping up environment friendly refrigerant as per existing suitable for water cooler up to the required level of 40/80 ltr complete all as directed by Engineer-in-Charge.
M & L for complete charging with environment friendly refrigerant as per existing suitable for water cooler up to the required level of 40/80 ltr complete alll as directed by Engineer in Charge.
M & Labour for spray painting to water cooler of capacity 40 lit and cooling capacity 80 lit per hour by painting outer cover with two coat of synthetic enamel paint of approved make and writing of sr no/SM/MES No complete all as directed by Engineer-in- Charge.
M&L for Taking out defective sealed compressor unit of 40/80 Ltr/hr cap of water cooler and M & L for replacement for sealed compressor unit of suitable for water cooler of 40/80 lit/hr cap , reassemble and testing complete as to the entire satisfaction of Engineer-in- Charge.
M & L for finding out leakage of condensor/ cooling unit of water cooler of 40/80 Ltr cap including dismantling the same for recharging and stop leakage by brazing/soldering including charging the R-134a gas up to required level and testing complete as to the entire satisfaction of Engineer-in- Charge.
Material and Labour for replacement of capacitor 10 mfd oil filled for water cooler.
Supply and fixing starting capacitor clip type of cap 80-100 mfd suitable for water cooler 40/80 lit/hr capacity.
S&F in repairs of over load protector relay suitable for water cooler of cap 40/80ltr/hr of approved make complete all as specified and directed by Engr-in-Charge.
M & L for replacement of condenser Fan motor of water cooler 40/80 ltr/hr capacity as per existing sample or approved make and testing complete all as to the entire satisfaction of Engineer-in-Charge.
M & L for replacement of fan blade of water cooler/blower as per existing sample at the ground complete all as directed by Engineer-in-Charge.
S & F in repairs of Thermostat suitable for water cooler 40 Ltr/hr capacity of approved make complete all as specified and directed by Engr-in-Charge.
Material and Labour for brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple directed by Engineer -In -charge
M&L for replacement of defective sealed compressor unit upto 320 Ltr cap refrigerator. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make it functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of refrigerator upto 320 Ltr cap including dismantling the same for recharging and stop leakage by brizing/soldering including charging the environment friendly refrigerant up to the required level and testing the refrigerator for the entire satisfaction of EIC.
M&L for replacement of defective sealed compressor unit of 320 ltr cap deep freezer. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of deep freezer 320 Ltr cap including dismantling the same for recharging and stop leakage by brizing/soldering including charging the R-134A gas to required level and testing the refrigerator for the entire satisfaction of EIC.
S & F replacement of defective swing motor with new motor suitable for 1.5/2 ton window and split type AC all as specified and directed by Engr in Charge.
Supply and fix in repair outer body for window type AC 1.5 / 2.0 TR comprising double shaft blower motor with fan blade and electrical accessories all as specified and directed MAKE: LG, Carrier, Samsung, Voltas, Hitachi.
Supply and fix in repair front grill for window type AC 1.5 /2.0 TR. Complete all as specified and directed by engr in Charge.MAKE: LG,Carrier,Samsung,Voltas,Hitachi.
S& F for replacement to unserviceable cordless remote with new suitable for machine of 1.5/2.0 TR split type AC complete all as specified and as directed by Engineer-in-Charge.
Dismantling to voltage stablizer upto 4 KVA for repair including rewinding and assembling , testing after repair work complete all as specified & as directed by Engineer -in-Charge.
Supply & fix replacement condenser 240 volts 2.5 MFD, Heavy duty incl testing.
Supply & fix replacement condenser 240 volts 5/6 MFD for refrigerator, heavy desert cooler incl testing.
S&F in repair 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded complete all as specified and as directed.
Material and labour for painting to old steel surfaces of Desert cooler of Air flow capacity up to 5000 Cu M/hr with two coats of synthetic enamel spray paint hammer tone paint of approved colour make ICI paint (Dulax closs), asian paint (Apcolite), Jenson & Nicholson,over one coat of red oxide on external surface and two coats of anti corrosive black paint inside the Body tank and side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES No in 25mm height etc complete all as specified and directed by Engineer-in-Charge at site
M&L for replacement of copper conductor cable 40/0.75 Sqmm 3 core 5 m long with plug top 5 Amp inbuilt suitable for desert cooler.
M&L for Replacement of PVC water distributor with PVC pipe and PVC pipe elbow complete for desert cooler upto 5000 CFM all as directed by EIC.
M&L for replacement of Fan blade of desert cooler heavy duty HDPE suitable for 4000/5000 CFT cap complete all as directed by EIC.
M&L for replacement of Water lifting submersible pump of head 1.2 m approx suitable for desert cooler as per existing capacity.
M&L for Taking down desert cooler fan motor and supply and fixing new desert cooler fan motor with outer ring and nut-bolts for desert cooler upto 5000 CFM copper wounded, three speed approved make complete all as directed by EIC.
M&L for Taking down u/s desert cooler motor, cutting of burnt out winding and rewinding super enamelled copper conductor fixing of desert cooler motor to existing location complete all as specified and directed by Engr-in-Charge. make all as directed by EIC. Note:- Contractor will produce Guarantee letter for the rewinding of the motor minimum 1 year from the date of installarion and testing.
Supply & Fix in repairs wood wool Pad (set of three), minimum weight 0.80 kg, inside panels of desert coolers complete all as directed by EIC.
Supply & Fix in repairs capacitor 4 MFD for fan motors of desert cooler.
M&L for Replacement of rusted and leakaged body parts (Water tank) of Desert cooler of 4000/ 5000 CUM/hr capacity as required at site with existing gauge of wire :-
As item no. 66 but herein Side lags
As item no. 66 but herein Top cover
As item no. 66 but herein Front grill with connection strip
As item no. 66 but herein Supporting legs with frame and clips incl nuts & bolts of desert cooler.
M&L for taking down fan of any type/make and size carefully from fan hook, dismantling of blades and transporting from any location in side army area to MES E/M store yard for washing throughly of bearing/bush by petrol , washing and cleaning the fan blades , body , canopy etc throughly , provision of new greasing , replacement of worn out/ defective unserviceable parts including fan rod (wherever necessary ) reassembling the same and testing the fan to entire satisfaction of Engr-in-Charge Note:- (i) Replacement of defective / unserviceable parts will be paid separately under relevent items of this schedule(ii) The cost for labour to taking out and refixing the new material is deemed to be inclusive of quoted rates. (iii) Any type of petty items which are not included in this schedule will deemed to be inclusive of quoted rates.
M&L for Removing rusts/dusts cleaning thoroughly with petrol to the ceiling fan in situ and spray painting with one coat to ceiling fan of any size and type with 1st quality synthetic enamel paint as per exsisting colour to fan body, down rod/ canopy etc and writing the MES number as MES/NT-(No) on the fan body in black paint all as directed by Engineer-in-Charge.
M&L for taking down burnt out ceiling fan of any type and size , dismantling the fan blades ,opening the cover to Cutting the existing copper winding and rewinding the armature (Rotor) with super enamelled copper wire of suitable gauge incl all insulating materials complete and re-assembling the fan, fan blades and hanging in fan hook to the same location by providing three core copper (FRLS) cable not less than 0.75 sqmm from ceiling rose or connector to fan and satisfactory testing on full speed to entire satisfaction of Engineer-in-Charge.Note:- (i) Contractor will produce guarntee letter for rewinding of fan minimum 1 year from the date of installation and testing (ii) The cost of transportation will deemed to be inclusive of quoted rates.(iii) Cost of labour for taking down and refixing will deemed to be inclusive of quoted rates.(iv) Any petty items required for fixing will deemed to be inclusive of quoted rates.
Supply only plug top 15 amps,230 V all as directed by Engineer-in-Charge.
S&F fan blades set of ceiling fan for any sweep of the existing make all as directed by Engineer-in-Charge.
S&F rubber reels incl shackle clamp, bolts, nuts, washers split pins of appropriate size as required at site all as directed by Engr-in-charge.
S& F ball bearing of suitable to ceiling fan including testing complete all as specified and directed by Engr-in-charge.
S&F bush bearing made out Gun metal suitable for ceiling fan complete all as directed and specified by Engr-in-charge.
M&L for down rod of 15mm dia GI pipe heavy duty 45 cm long incl machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable to any type and sweep size of fan.
M&L for taking down the burnt out wall mounting air ciculator fan dismantal the blades ,opening the cover to cutting the existing copper winding and rewinding the armature (Rotor) with super enamelled copper wire of suitable gauge incl all insulating materials varnishing and heating complete and refixing at same location after painting to entire body of wall mounting fan with synthetic enamel paint as per exsisting colour by using spray gun incl satisfactory testing on full speed complete all as directed by Engineer-in-Charge of the following sizes Note:-(i) Cost of items except rewinding will be measured and paid separately under relevent items of this schedule (ii) Quoted rate is deemed to be inclusive of transporting and taking down unserviceable/defective parts.of size 400/450/600 mm sweep any make.
Replacement of damaged/defective MS fan blades for 600 mm sweep Air Circulator fan complete all as specified and directed by Engr-in-Charge.
Replacement of damaged/defective MS fan blades as per existing for 450/400 mm sweep Air Circulator fan complete all as specified and directed by Engr-in-Charge.
M&L for Rewinding the armature of exhaust fan of any make with super enamelled copper wire of suitable for incl all insulating materials varnishing complete incl satisfactory test run on full speed complete for the 300/380/450 mm sweep exhaust fan any make.
M&L for Replacement of supporting legs with frame and clips incl nuts & bolts of size suitable for 380 mm sweep size exhaust fan incl taking down unserviceable leg frame.
M&L for Replacement of supporting legs with frame and clips incl nuts & bolts of size suitable for 300 mm sweep size exhaust fan incl taking down unserviceable leg frame.
M&L for Replacement of damaged/defective MS fan blades assembling for 300/380/450 mm sweep exhaust fan.
S&F in repairs exhaust fan louvers suitable to any sweep to out side building including making necessary arrangement like ladder/scaff holding etc and drilling of hole for fitting of exhaust fan louvre complete all as directed by Engineer-in-Charge.
S & F in replacement Push type Bib Tap for water cooler made of brass cromium plated suitable for water cooler upto 120 Ltr capacity.
S&F in replacement water tray suitable upto 120 Ltr capacity water cooler made of SS and all as per sample complete.
J AND T Enterprises
DIWAKAR CONSTRUCTION CO.
Anil Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .