Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹28.3 L+₹1.5 L (5.79%)Admitted-Finance B WING 601 602 DELPHI BUILDING CENTRAL AVENUE HIRANANDANI BUSINESS PARK POWAI MUMBAI MAHARASHTRA 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical PQC failed | |
| 4 | Rejected-Technical NO 144 SEEVARAM 1ST STREET PERUNGUDI CHENNAI TAMIL NADU 600041 | CHENNAI | TAMIL NADU | 600041 | - | Rejected-Technical PQC failed | |
| 5 | Rejected-Technical A36 B14 H BLOCK MIDC ESTATE PIMPRI PUNE 411018 PUNE MAHARASHTRA 411018 | PUNE | MAHARASHTRA | 411018 | - | Rejected-Technical PQC failed |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
1 Aug 2019, 2:00 pmClosed
VARGHES MATHEW
MATERIALS DEPARTMENT PD ADMIN BUILDING FACT LTD. UDYOGAMANDAL PO KOCHI, KERALA 683501
PROCUREMENT OF MASS FLOW METER for Liquid Ammonia and Sulphuric Acid services at FACT Cochin Division, Ambalamedu
2019_FACT_481760_1
MM/172/E19855
Open Tender
Miscellaneous Goods
Supply
AMBALAMEDU
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1 L
Yes
6 Feb 2020
28 Jun 2019
2 Aug 2019
28 Jun 2019
1 Aug 2019
28 Jun 2019
Mass Flow meter, Coriolis Type Process Conditions: Flow Range in Tonnes/Hour : 0-9 End connection : 1 , ANSI 150 Service : Sulphuric Acid Working Pressure : 10 kg/cm2 Density : 1.84 kg/m3 Working Temperature : -35 Deg C to 150 Deg.C TRANSMITTER: Type : Smart Microprocessor based Remote Field Mounted with Display Display : Required, LCD backlit, alphanumeric Range : User Configurable Flow accuracy (including sensor) : Better than +/-0.15% Flow Repeatability (including sensor) : Better than +/-0.1% Output 1) Analog Output, 4-20 mA DC, HART compatible Output 2) Pulse Output Maximum Load Impedance : <500mohms Power Supply : 110VAC, 50 Hz +/- 10% Display Language : English Display shall have: a) Actual flow rate; b) Flow units : T/hr, kg/hr configurable through front panel keypad c) Totalizer (non-volatile) with Reset facility d) Totalizer units: Tonnes; Kilograms e) Density; f) Density Units : g/cc g) Status / error messages Calibration facility : Required through front panel keypad and HART communicator Configuration : Required through front panel keypad and HART communicator Protection with access code: Required for calibration/ configuration/setup data Memory : Non-volatile EEPROM Self-Diagnostics : Required Empty or Partially filled flow tube detection : Required Cable entry : 1/2 NPTF Junction box/ terminal box material : Die Cast Aluminium Enclosure : Weather proof to IP 67 Mounting Brackets : Required, SS304 for pipe mounting Working Temperature : 0 to 55 Deg.C Humidity : Up to 95%(RH) SENSOR: Type : Coriolis type, enclosed in a hermetically sealed housing Meter size and pressure rating : Vendor to specify End connection : Flanged, RF Flowtube/Wetted Parts Material : Hastelloy C or better suited for the process fluid Housing Material : SS304 Junction box/ terminal box material : Die Cast Aluminium Interconnection cables between Sensor and Transmitter : 25 metres required Distance between sensor & transmitter : 25 m (maximum) Interchangeability of Sensor and Transmitter : required Instrument details : To be punched on SS plate mounted on sensor and transmitter. Explosion proof certification required for Sensor & transmitter Hydraulic test pressure : 1.5 times Maximum Working Pressure Painting : As per manufacturer’s standard.
Mass Flow meter, Coriolis Type Process Conditions: Flow Range in Tonnes/Hour : 0-25 End connection : 2 , ANSI 150 Service : Sulphuric Acid Working Pressure : 10 kg/cm2 Density : 1.84 kg/m3 Working Temperature : -35 Deg C to 150 Deg. C TRANSMITTER: Type : Smart Microprocessor based Remote Field Mounted with Display Display : Required, LCD backlit, alphanumeric Range : User Configurable Flow accuracy (including sensor) : Better than +/-0.15% Flow Repeatability (including sensor) : Better than +/-0.1% Output 1) Analog Output, 4-20 mA DC, HART compatible Output 2) Pulse Output Maximum Load Impedance : <500mohms Power Supply : 110VAC, 50 Hz +/- 10% Display Language : English Display shall have: a) Actual flow rate; b) Flow units : T/hr, kg/hr configurable through front panel keypad c) Totalizer (non-volatile) with Reset facility d) Totalizer units : Tonnes; Kilograms e) Density; f) Density Units : g/cc g) Status/error messages Calibration facility : Required through front panel keypad and HART communicator Configuration : Required through front panel keypad and HART communicator Protection with : Required for Calibration/ access code configuration/setup data Memory : Non-volatile EEPROM Self-Diagnostics : Required Empty or Partially filled flowtube detection : Required Cable entry : 1/2 NPTF Junction box/ terminal box material : Die Cast Aluminium Enclosure : Weather proof to IP 67 Mounting Brackets : Required, SS304 for pipe mounting Working Temperature : 0 to 55 Deg.C Humidity : Up to 95%(RH) SENSOR: Type : Coriolis type, enclosed in a hermetically sealed housing Meter size and pressure rating : Vendor to specify End connection : Flanged, RF Flow tube/Wetted Parts Material : Hastelloy C or better suited for the process fluid Housing Material : SS304 Junction box/terminal box material : Die Cast Aluminium Interconnection cables between Sensor and Transmitter : 25 metres required Distance between sensor & transmitter : 25 m (maximum) Interchangeability of Sensor and Transmitter : required Instrument details : To be punched on SS plate mounted on sensor and transmitter. Explosion proof certification required for Sensor and Transmitter Hydraulic test pressure : 1.5 times Maximum Working Pressure Painting : As per manufacturer’s standard.
Mass Flow Meter, Coriolis Type Process Conditions: Flowrange in Tonnes /Hour : 0-15 End connection : 1 , ANSI 300 Service : Liquid Ammonia Working Pressure : 10 kg/cm2 Density : 0.6814 to 0.6453 g/cc Working Temperature : -35 Deg C to 150 Deg. C TRANSMITTER: Type : Smart Microprocessor based Remote Field Mounted with Display Display : Required, LCD backlit, alphanumeric Range : User Configurable Flow accuracy (including sensor) : Better than +/-0.15% Flow Repeatability (including sensor) : Better than +/-0.1% Output 1) Analog Output, 4-20 mA DC, HART compatible Output 2) Pulse Output Maximum Load Impedance : <(><<)>500mohms Power Supply : 110VAC, 50 Hz +/- 10% Display Language : English Display shall have: a) Actual flow rate; b) Flow units : T/hr, kg/hr configurable through front panel keypad c) Totalizer (non-volatile) with Reset facility d) Totalizer units : Tonnes; Kilograms e) Density; f) Density Units : g/cc g) Status / error messages Calibration facility : Required through front panel keypad and HART communicator Configuration : Required through front panel keypad and HART communicator Protection with access code : Required for calibration/configuration/setup data Memory : Non-volatile EEPROM Self-Diagnostics : Required Empty or Partially filled flow tube detection : Required Cable entry : 1/2 NPTF Junction box/ terminal box material : Die Cast Aluminium Enclosure : Weather proof to IP 67 Mounting Brackets : Required, SS304 for pipe mounting Working Temperature : 0 to 55 Deg.C Humidity : Up to 95%(RH) SENSOR: Type : Coriolis type, enclosed in a hermetically sealed housing Meter size and pressure rating : Vendor to specify End connection : Flanged, RF Flange to Flange Distance : 450 mm (Approx) Flowtube/Wetted Parts Material : SS316L Housing Material : SS304 Junction box/ terminal box material : Die Cast Aluminium Interconnection cables between Sensor and Transmitter : 25 metres required Distance between sensor <(>&<)> transmitter : 25 m (maximum) Interchangeability of Sensor and Transmitter : required Instrument details : To be punched on SS plate mounted on sensor and transmitter. Explosion proof certification required for Sensor and Transmitter Hydraulic test pressure : 1.5 times Maximum Working Pressure Painting : As per manufacturer’s standard.
Mass Flow Meter, Coriolis Type Process Conditions: Flowrange in Tonnes /Hour : 0-100 End connection : 3 , ANSI 300 Service : Liquid Ammonia Working Pressure : 10 kg/cm2 Density : 0.6814 to 0.6453 g/cc Working Temperature : -35 Deg C to 150 Deg. C TRANSMITTER: Type : Smart Microprocessor based Remote Field Mounted with Display Display : Required, LCD backlit, alphanumeric Range : User Configurable Flow accuracy (including sensor) : Better than +/-0.15% Flow Repeatability (including sensor) : Better than +/-0.1% Output 1) Analog Output, 4-20 mA DC, HART compatible Output 2) Pulse Output Maximum Load Impedance : <(><<)>500mohms Power Supply : 110VAC, 50 Hz +/- 10% Display Language : English Display shall have: a) Actual flow rate; b) Flow units : T/hr, kg/hr configurable through front panel keypad c) Totalizer (non-volatile) with Reset facility d) Totalizer units : Tonnes; Kilograms e) Density; f) Density Units : g/cc g) Status / error messages Calibration facility : Required through front panel keypad and HART communicator Configuration : Required through front panel keypad and HART communicator Protection with access code : Required for calibration/configuration/setup data Memory : Non-volatile EEPROM Self-Diagnostics : Required Empty or Partially filled flow tube detection : Required Cable entry : 1/2 NPTF Junction box/ terminal box material : Die Cast Aluminium Enclosure : Weather proof to IP 67 Mounting Brackets : Required, SS304 for pipe mounting Working Temperature : 0 to 55 Deg.C Humidity : Up to 95%(RH) SENSOR: Type : Coriolis type, enclosed in a hermetically sealed housing Meter size and pressure rating : Vendor to specify End connection : Flanged, RF Flowtube/Wetted Parts Material : SS316L Housing Material : SS304 Junction box/ terminal box material : Die Cast Aluminium Interconnection cables between Sensor and Transmitter : 25 metres required Distance between sensor <(>&<)> transmitter : 25 m (maximum) Interchangeability of Sensor and Transmitter : required Instrument details : To be punched on SS plate mounted on sensor and transmitter. Explosion proof certification required for Sensor and Transmitter Hydraulic test pressure : 1.5 times Maximum Working Pressure Painting : As per manufacturer’s standard.
Emerson Process Management (India) Private Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .