Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical VILL AYESHBAGH P O ROSHANBAGH P S DIST MURSHIDABAD PIN 742164 W B | MURSHIDABAD | MURSHIDABAD | WEST BENGAL | 742164 | Accepted-Technical Accepted |
| 2 | Rejected-Technical 3 NO BANJETIA COSSIMBAZAR BERHAMPORE DIST MURSHIDABAD W B | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742102 | Rejected-Technical Please see the attached copy |
| 3 | Rejected-Technical | Rejected-Technical Please see the attached copy |
Tender Value
₹1.7 Cr
EMD Value
₹3.5 L
Closing Date
28 Jan 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr.Superintending Engineer, Central Circle, PWD
O/O the Superintending Engineer, Central Circle, PWD, Berhampore, Murshidabad
ANCILLARY WORK FOR PROPOSED 50 BEDDED CRITICAL CARE BLOCK CCB IN THE N.G CAMPUS OF MURSHIDABAD MEDICAL COLLEGE and HOSPITAL UNDER BERHAMPORE DIVISION NO-II, PWD. PART-B Plus PART-C.
2025_PWD_981275_1
WB/PWD/SE/CC/e_NIT_11 OF 2025-26
Open Tender
CIVIL WORKS
Percentage
180 days
Berhampore_Murshidabad
Please refer Tender documents.
4 documents required · 4 mandatory
₹3.5 L
Yes
Office of the SE/CC/PWD
23 Feb 2026
30 Dec 2025
30 Jan 2026
7 Jan 2026
28 Jan 2026
7 Jan 2026
7 Jan 2026
TOTAL
Item Rate BoQ
BoQ_Ver3.0
Tender id.: Tender Reference No: WBPWD/SE/CC/E_NIT 11 of 2025-26
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Effluent Treatment Plant (ETP)/STP Bar Screen Supplying, installing & commissioning of fabricating stainless steel [AISI 304] vertical screen, height of screen 500 mm x 600 mm width; screen fabricated in S.S. Pipes 20 mm ø [wall thickness approx 1.0 mm] with end stoppers. Aluminium end channels 50 mm x 5 mm for screen guides - length about 1.5 m x 2 nos. Clear opening between pipes = 15 mm. Lifting of screen manually. Supply of galvanised chain & hook attached to screen for facility of lifting. Upstream of the screen to be provided with S.S. Lip-200 mm at bottom of screen with 6 mm opening so that screenings can be drained, trapped & removed [Approximate weight of screen & accessories = 20 kg approx.].
Equalisation Pumps Supplying, installing & commissioning of non clog dry motor submersible pumps as per specifications for equalisation tank, for feeding of effluent from equalisation tank to aeration tank including nolta level sensors, 1.25 cum/hr. Make: KSB or Equivalent
Diffuser System Supplying, installing & commissioning at site complete SS diffuser system of pipe from top. SS pipe 32 mm ø laterals. Tubular diffusers 65 mm ø x 600 mm long [approx - 12 nos] with 20 mm end connections. For equalisation tank and aeration tank size as per Dwg. [1.30 x 1.30 x 2.50 m and 2.25 x 2.25 x 2.50]. Pipes on floor to be placed on galv chairs. Pipes to remain on self weight. And the diffuser system complete with control valves. Make: Scogen with SS pipe or Equivalent
Sludge Recirculating Pumps Supplying, installing & commissioning of sludge recirculation pumps 1.25 m3/hr at 3 MWC. Complete with horizontal foot mounted motor TEFC IP55. Make: KSB or Equivalent
Flocculator Supplying, installing & commissioning of sludge recirculation by pass pipeline for basket centrifuge complete with pipe coil Flocculator. Make: W2P or Equivalent
Clarified Water Pumps Supplying, installing & commissioning of clarified water pumps, horizontal foot mounted with IP 55 motor complete with base frame & nuts /bolts for filter feed - 1.25 m3/hr at 20 MWC. Suction pipe line of cwt pumps to be connected to filtered water tank for backwash purposes. Make: KSB or Equivalent
Pressure Sand Filter Supplying, erecting & commissioning at site M.S. Pressure sand filter [PRF] for filtering approximately 1.25 cum/hr clarified effluent from sewage treatment plant. The PRF is to be manufactured in 6 mm thick plates [vertical cylinder & 8 mm thick dished end plates. The PRF is to be complete with TATA [m] M.S. Frontal piping of 40 mm ø with flanges wherever required. All filter controls will be with die cast wafer type butterfly valves or brass ball valves [kitz make]. All nuts & bolts/washers will be S.S 304. The PRF will be provided with internal filter plate with PVC nozzles. Filter media will be graded gravel & grit of minimum 1.2 m depth. Hos will be minimum 1.2 - 1.5 m. The complete filter shell will be fixed on M.S. Fabricated pedestals [tripod or quardapod]. It will rest on RCC floor. The shell will have access doors suitable for material can be introduced or removed from inside. The inside & outside shall be sand blasted after fabrication so as to get a near silvery finish. Immediately thereafter the inside shall be primer coated & painted with non poisonous bitumentic drinking water paint 2 coats. The outside shall be painted with 2 coats of zinc rich epoxy primer & 1 coat of epoxy shop paint of approved shade. Thereafter 1 coat of finishing epoxy paint shall be applied after erection & commissioning. Shell dia shall be min 450 mm.
Plumbing Items Supplying, laying & commissioning of all necessary dia. PVC pipes SCH: 40, ASTM D with all necessary fittings / flanges suitable for solvent welding with Weldon heavy duty cement. All interconnecting control brass ball valves / die cast aluminium valves with necessary flanges & S.S. Nuts / bolts / washers also to be provided as per drawing. Approx diameter of pipes will be 40 mm & 32 mm from pumps to various tanks & upto filter & all by pass arrangement with suction & delivery valves - ; all pumps discharge pipes shall be independent without valves except filters. Raw sewage pumps will have direct pumping with bypass outlet control. Make: Supreme or Equivalent.
Cable Supplying, laying & commissioning of copper flexible cables suitable for power connections from MCC to all load point. Cable sections shall be 3/4 core x 1.5/2.5/4/6 sqmm. Internal lighting points are not required. The cables are to be supplied with all eyelets, termination accessories, cable jointing epoxy compound with appropriate join boxes etc complete. It is to be noted that the MCC will be a little away from the ETP. Cable lengths to be calculated accordingly. All jointing boxes shall be fully waterproof. As far as practicable there shall be no join boxes from MCC to above ground motors. Join boxes will be allowed for submersible motors. MCC will be inside shed nearby. Make: Finolex or Equivalent
Earthing Wire Supplying, installing & commissioning of galv. Earthling wire 6 gauge suitable for double earthling of each motor & MCC. This will be connected to earthling grid provided by client adjacent to STP. Earthling pits shall be clients' scope of work.
Equalisation Tank Air Blower Supplying, installing & commissioning of approx 15nm3/hr blower at 4 MWC for diffuser system in item (3) above. Length of connection to diffuser system lateral with 32 mm dia G.I. Pipe [approx. 40 m] will be included. Blower to be coupled with TEFC SQ. Cage IP55 continuous rated foot mounted motor, class 'f' insulation, mounted on M.S. Fabricated base frame duly epoxy coated. Sound level should not be more than 65 db. Rpm of blower should not exceed 1200. The blower will be supplied with acoustic hood of good quality so that external sound is not disturbing. Make: KAY or Equivalent
Aeration Tank Air Blower Supplying, installing & commissioning of approx 30nm3/hr blower at 4 MWC for diffuser system in item (3) above. Length of connection to diffuser system lateral with 32 mm dia G.I. Pipe [approx. 40 m] will be included. Blower to be coupled with TEFC SQ. Cage IP55 continuous rated foot mounted motor, class 'f' insulation, mounted on M.S. Fabricated base frame duly epoxy coated. Sound level should not be more than 65 db. Rpm of blower should not exceed 1200. The blower will be supplied with acoustic hood of good quality so that external sound is not disturbing. Make: KAY or Equivalent
Dosing System Supplying, installing & commissioning of dosing systems for acid, alkali, phosphorous, ammonia nutrients as required with pumps, tank & feed pipe. Make: E-dose or Equivalent
Fabricated - MS FRP Tanks Supplying, erecting and commissioning of MS FRP tanks (Aeration tank - 2.00 x 1.20 x 3.00 m, Tube settler tank - 1.20 x 1.20 x 3.00 m & Clarified water tank - 1.20 x 1.20 x 3.00 m). Total dimension of tanks - 4.50(L) x 1.20(W) x 3.00 (D) m.
Commissioning of total ETP system.
Operation & Maintenance Operation & Maintenance charges with Bacteria and Chemical for Six Months.
Fire Protection System HYDRANT SYSTEM Supply, erection, testing & commissioning of Electrical Motor driven terrace pump, with gland packing capable of deliver 900 LPM at 35 MWC. The pump shall be coupled with TEFC motor of suitable KW with speed of 2900 RPM with necessary cable and all accessories with push button station and complete set shall mounted on common base frame. The quoted rate shall include fixing of coupling, coupling guard and foudation bolts etc. Civil foundation will be client's scope.
Supply, erection and testing of heavy grade(class-C) pipes conforming to IS-1239 / IS-3589 including all fittings viz. tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer and structural steels for pipe supports. Hanger support with anchor fasteners and clamps shall be supplied to fix the pipes on ceiling wall etc. including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) as per specification. Cutting of floors, walls etc and making it good after erection of pipes shall be of vendor's scope. Necessary painting with 2 coats of primer and 2 coats of synthetic enamel paints to be done and supply of paints shall be with vendor's scope. 150 mm NB
Supply, installtion, testing and commissioning of swinging type CI Non return Valve as per IS:5312 with SS trim including matching flanges, nuts, bolts and gaskets. Size 100 mm NB
Supply, installation, testing & commissioning of CI Butterfly valve as per BS :5155 (Wafer type) with matching flanges,nuts & bolts and gasket. 150 mm NB
Supply and installation of Globe Valves in Bronze Construction to IS: 778 with screwed ends 25 NB size.
Supply & installation of GM / SS oblique type single headed Landing valve with 80 mm inlet and 63 mm outlet GM / SS instantaneous male coupling with rubber cap and chain conforming to IS : 5290 including matching flanges, gasket, nuts and bolts.
Supply & installation of GM / SS branch pipe with 20 mm nozzle conforming to IS : 903.
Supply & installation of 63 mm dia reinforced rubber line hose pipe in 15 m length conforming to IS : 636 Type II ISI marked with GM/SS male and female instantaneous coupling conforming to IS 903 wounded with 18 SWG copper wire.
Supply & installation of hose box, fabricated from 16 SWG CRCA sheet, double door with lockable arrangements to accommodate 2 RRL hose of 15 m length and one branch pipe painted white inside and red outside with one key. (750x600x250 mm).
Supply & installation of swinging type hose reel drum fabricated from 14 SWG CRCA sheets painted with red colour stove paint 2 coats over 1 coat of primer. The length of hose shall be with 30 m with 20 mm dia. Working pressure rating shall be 18 kg/sq. The pipe shall be coupled with SS/GM self closing shut – off nozzle of 5 mm outlet.
Supply & installation of GM / SS 2 way Fire Brigade Inlet with 63 mm dia instantaneous type coupling and 100 dia flanged outlet. Each inlet coupling shall be with built in check valve. The inlets shall conform IS:904.The inlet connection shall be mounted on hydrant riser.
Supply & installation of dial type Pressure Gauge of suitable pressure range, fitted with dampner arrangement and isolation ball valve as shown in respective drawing. The diameter of dial shall be 150 mm preferably filled up with glyserine. All other necessary fittings to be supplied to erect the gauge on top of the riser.
AUTOMATIC SPRINKLER SYSTEM Supply, erection, testing & commissioning of Electrical Motor driven terrace pump, with gland packing capable of deliver 900 LPM at 35 MWC. The pump shall be coupled with TEFC motor of suitable KW with speed of 2900 RPM with necessary cable and all accessories with push button station and complete set shall mounted on common base frame. The quoted rate shall include fixing of coupling, coupling guard and foudation bolts etc. Civil foundation will be client's scope.
Supply, erection and testing of heavy grade(class-C) pipes conforming to IS-1239 / IS-3589 including all fittings viz. tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer and structural steels for pipe supports. Hanger support with anchor fasteners and clamps shall be supplied to fix the pipes on ceiling wall etc. including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) as per specification. Cutting of floors, walls etc and making it good after erection of pipes shall be of vendor's scope. Necessary painting with 2 coats of primer and 2 coats of synthetic enamel paints to be done and supply of paints shall be with vendor's scope. 150 mm NB
Supply & installation of SS Sprinkler Head , K-80, chrome finish Pendent type
Supply, installation, testing & commissioning of CI Butterfly valve as per BS :5155 (Wafer type) with matching flanges,nuts & bolts and gasket. 150 mm NB
Supply, installtion, testing and commissioning of swinging type CI Non return Valve as per IS:5312 with SS trim including matching flanges, nuts, bolts and gaskets. Size 100 mm NB
Supply and installation of Globe Valves in Bronze Construction to IS: 778 with screwed ends.40 mm NB
Supply & installation of dial type Pressure Gauge of suitable pressure range, fitted with dampner arrangement and isolation ball valve as shown in respective drawing. The diameter of dial shall be 150 mm preferably filled up with glyserine. All other necessary fittings to be supplied to erect the gauge on top of the riser.
PORTABLE EXTINGUISHERS Supply & fixing of 4Kg dry power extinguisher consisting of welded MS cylindrical body with discharge valve, nozzle & CO2 cartage and hanging arrangement complete conforming to IS:2171.
Supply & fixing of 9 Litre Water type CO2 (ISI marked) extinguisher including all accessories with wall bracket & raw plug conforming to IS:940
Providing & fixing 9 Litre Foam type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:10204.
SIGNAGES Supply and installation in position the "FIRE EXIT" Sign with luminicent colour having size 300 x 100 mm.
Supply and fixing in position the signages " FIRE ORDER" contain the following matter on 3 mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of size 1200 x 1000 mm. ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION. EVACUATE THE OCCUPANTS BY USING FIRE EXIT AND EMERGENCY EXITS ONLY AND ASSEMBLE AT ASSEMBLY POINTS. BE CALM AND DO NOT GET PANIC, WALK DO NOT RUN IF POSSIBLE TRY TO EXTINGUISH FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. (Make-MINIMAX / FIRESHIELD/ SAFEX ).
Supply and fixing signage with printed " IN CASE OF FIRE, DO NOT USE LIFT. USE STAIRS ONLY" OF 1.5 cm height letters in red with white background. The size of the board shall be 300 x 250 mm and shaall be fixed at the height of 2 mtrs.from finished floor near Manual Call Point.
Percentage BoQ
BoQ_Ver3.0
Tender id.: Tender Reference No: WBPWD/SE/CC/e_NIT 11 of 2025-26
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
ETP & CHILLER ROOM (CIVIL WORK) Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) Do - by fine sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor [Pakur Variety] 1:3:6 proportion
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) 25 mm to 30 mm shuttering without staging in foundation
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. upto roof of ground floor)
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade Pakur Variety
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4m Tor steel / Mild steel SAIL /TATA/RINL
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
Brick work with 1st class bricks in cement mortar (1:6) In SUPERSTRUCTURE, GOUND FLOOR
Labour for Chipping of concrete surface before taking up Plastering work
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar.. 15 mm thick plaster.
20mm thick plaster
With 1:4 cement mortar. 10mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq. Mtr and upto 16 kg/Sqm.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Solvent based interior grade Acrylic Primer
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC (a) One Coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Premium 100% Acrylic Emulsion
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Luxury Quality Gr floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Priming one coat on timber or plastered surface with synthetic oilbound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (A) On steel or other metal surface With super gloss (hi-gloss) -(i) Two coats (with any shade except white)
On timber or plastered surface : With super gloss (hi-gloss) -With other than hi-gloss of approved quality- (i) Two coats (with any shade except white)
25 mm. thick damp proof with cement concrete (1:1.5:3) (with graded stone aggregate 10 mm. normal size) and painting the top surface with a coat of bitumen [VG.40 ] using 1.7 kg. per sq.m. including heating the bitumen and cost and carriage of all materials complete. [Bitument to be supplied by the Agency]
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof For structural members of specified sections weighing less than22.5 Kg./m
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all comlete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. For trusses spanning up to 12.00 m M.S pipe 75mm dia
Supplying. fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT( Base Metal Thickness ) (0.50mm TCT ( Total coated thickness excluding paint), G$S0 (min Ss0 yield strength), ofZincalume metallic coating (ISIS965) with high Solar Reflectance lndex (SR) valuefor better colling as per thermatechtechnology.1000-1015mm effective cover widthwith five major corrugation, 28mm high rib spaced ut 203mm cde with subtle squareluting in the pan and the end rib shull have anti-capillary groove and return lg.Thesteel sheet shall be fustened with 40 micron zinc coated or 25 micron zinc-tin alloycoated, hex head. self-drilling scre as per IS 3566-2002 Cluss 3 fastener. The basesteel shall be coated with zinc-aluminium alloy Zincalume (AZI50 )(ü.e. $5% Al,43.4% Zinc, 1.6% Si) ninimum of 150 g/m2 coating total on both sides. pre-paintedwith colorbond NRW(xterior roofing, walling ) paint system of 35 micron SuperDurable Polyester paint ( SDP) with stable inorgunic pigment with no lead contentsjconfirming ISI 5965. The sheet shall be free from defects and have brand marking ofthe manufucturer giving product details on the back of the sheet at regulur intervalconfirming genuinity of the material.
BOUNDARY WALL:- Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) depth of excavation not exceeding 1500mm
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) b) do by fine sand
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor. (a) 1:3:6 proportion (A) [Pakur Variety]
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (a) M 25 Grade
Reinforcement for Reinforced concrete work in all sorts of structure in/c distribution bars, stirrups, binders etc in/c supply of rods initial straightening and removal of loose rust (if necessary) cutting to requsite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection comp as per drawing and direction. a) for works in foundation, basement and upto roof of ground floor / upto 4m. SAIL/ TATA/RINL
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) 25 mm to 30 mm shuttering without staging in foundation.
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Labour for Chipping of concrete surface before taking up Plastering work
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20 mm thick plaster ground floor
With 1:4 cement mortar 10mm thick plaster
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. in ground floor: (a) One Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.in ground floor: (Two coat) a) Premium 100% Acrylic Emulsion
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface With super gloss (hi-gloss) Two coats (with any shade except white)
ELECTRIC CABLE TRANCE :- Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) depth of excavation not exceeding 1500mm
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) a) do by fine sand
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
Reinforcement for Reinforced concrete work in all sorts of structure in/c distribution bars, stirrups, binders etc in/c supply of rods initial straightening and removal of loose rust (if necessary) cutting to requsite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection comp as per drawing and direction. a) for works in foundation, basement and upto roof of g/floor / upto 4m. i) for tor steel/mild steel Other than SAIL/TATA/RINL.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm shuttering without staging in foundation
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (a) 10mm thick plaste In ground floor
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
SEMIUNDER GROUND R.C.C. RESRVIOR 200000 LTR.:- Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) depth of excavation not exceeding 1500mm
Depth of excavation for addl depth beyond 1500 mm and upto 3000 mm
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) a) do by fine sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 25 Grade (i) Pakur Variety
Reinforcement for Reinforced concrete work in all sorts of structure in/c distribution bars, stirrups, binders etc in/c supply of rods initial straightening and removal of loose rust (if necessary) cutting to requsite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection comp as per drawing and direction. a) for works in foundation, basement and upto roof of g/floor / upto 4m. i) for tor steel/mild steel Other than SAIL/TATA/RINL
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) 25 mm to 30 mm shuttering without staging in foundation
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Labour for Chipping of concrete surface before taking up Plastering work
Applying 2 coats of bonding agent with synthetic multi functional rubbeemulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer'sspecification [Cement to be supplied by the Department]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:4 cement mortar (a) 10mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item isnot permitted with ordinary cement).Using grey cement (iii) 35 mm. thick
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (ii) 50 mm dia. medium quality
Supplying, fitting and fixing gunmetal wheel valve of approved brand andmake tested to 21 kg per sq. cm. (for water lines only) (iv) 50mm dia.
PLINTH PROTECTION AND SURFACE DRAIN:- Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) depth of excavation not exceeding 1500mm
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) a) do by fine sand
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor [Pakur Variety] 1:3:6 proportion
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (a) M 25 Grade
Reinforcement for Reinforced concrete work in all sorts of structure in/c distribution bars, stirrups, binders etc in/c supply of rods initial straightening and removal of loose rust (if necessary) cutting to requsite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection comp as per drawing and direction. a) for works in foundation, basement and upto roof of g/floor / upto 4m. i) for tor steel/mild steel Other than SAIL/TATA/RINL
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) 25 mm to 30 mm shuttering without staging in foundation
25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:4 cement mortar (a) 10mm thick plaster In ground floor
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
SINKING OF TUBE WELL:- Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other dental works in the connection. The tube well should have a minimum 50 mm gap in betweenthe outside of the tubewell pipe and the bore. (a) For depth upto 150 metre for 40 mm dia. Tube well with top enlargement of 80 mm dia 80 mm dia. boring etc. top enlargement
b) For depth upto 150 metre for 80 mm dia. tube well with topenlargement of 150 mm dia.
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications. 80 mm dia
Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. 75 mm dia.
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. 75 mm dia.
Supplying, fitting and fixing heavy type bell mouth reducing socket. 75mm x150mm
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). withall necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes 80 mm dia
150 mm dia
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. 300 mm
18 Supplying, fitting and fixing G.I. cap at top 150 mm
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, cafolding, labour etc. all complete.
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer- ncharge including cost of all materials labour and equipment complete.
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted withholder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately) For Exposed Work (i) 40 mm dia. medium quality
150 mm dia. medium quality
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 40 mm dia
LANDSCAPING, GARDENING & BEAUTIFICATION:- Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (i) Withcarriedeartharrangedby thecontractorwithin a radius of 3 km. including cost of carried earth.
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Brick gabion 1.50 m.internal diameter and 1.20m. highwith 150 mm. deep solid brick band (in 1:6 cement mortar) at base,125 mm.thick body of jaffry brick work set in cement mortar (1:4) and 150 mm. deep solid brick band at top in cement mortar 1:6 and cement plaster (1:6) (all faces) including colour wash (all surfaces) to the top band and redoxide or similar approved wash (all surfaces) to the remaining portion, complete as per direction
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor [Pakur Variety] 1:3:6 proportion
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and Laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks (with Concrete grade as specified as per Table 1 of IS 15658 2006) manufactured from BIS licensee manufacturer, with spacer nih (Small protruding profiles on thevertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per Cl. No 3.26 of IS: 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per CL.No.3.3 of IS: 15658) as per Table 2 of IS 15658 with flexural strength/breaking loud as per Annexure G of IS:15658,on the prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP-63) and filling up the gaps in between paver blacks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per Cl. No. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap. 60 mm thick (i) Coloured Decorative
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levellingas directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart planting hedge plants in two rows of 30cm apart
Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc. i) Furcaria veriegated 10-12 leaves in height 20-30cm in earthen pots of size 25cm.
ii) Ficus blakii (F. Vivicon) well branched (Bushy) of height 120cm - 135 cm in earthen pot of size 30cm.
iii) Duranta healthy plant of big size
iv) Acalypha species (Red/Green) of height 30cm-90cm in earthen pots of size 20 cm.
v) Croton (broad leaves) 3-5 branches of height 90cm120cm in cement pots of size 30 cm.
Supplying,fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.) a) For exposed Work 40 mm dia.,Medium quality
25 mm dia.,Medium quality
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. markng with fittings(tested to 21 kg/sq.cm.). 40 mm dia
25 mm dia
CONSTRUCTION OF ELECTRICAL SUB STATION:- Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required completea) depth of excavation not exceeding 1500mm
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) do by fine sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety](a) 1:3:6 proportion
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 320 Kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 25 Grade (i) Pakur Variety
Reinforcement for Reinforced concrete work in all sorts of structure in/c distribution bars, stirrups, binders etc in/c supply of rods initial straightening and removal of loose rust (if necessary) cutting to requsite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection comp as per drawing and direction. a) for works in foundation, basement and upto roof of g/floor / upto 4m. for tor steel/mild steel. SAIL/TATA/RINL
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) 25 mm to 30 mm shuttering without staging in foundation
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
Brick work with 1st class bricks in cement mortar(1:6) In SUPERSTRUCTURE, GOUND FLOOR
Labour for Chipping of concrete surface before taking up Plastering work
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar 20mm thick plaster In Gr. Floor
15 mm thick plaster In Gr. Floor
With 1:4 cement mortar (c) 10mm thick plaster In Gr.floor
Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: One Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.in ground floor:(Two coat) Premium 100% Acrylic Emulsion
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).
Roof treatment by application of non toxic polyurethane modified acrylic based single component (P U Roof Coat) solvent free, cold applied polyurethane modified elastomeric waterproofing membrane with excellant UV resistant capasity as per ASTM D6083fa water based 100%acrylic elastomeric emulsion polymer latex coating , used as protective coating for roofs} after preparing the surface by cleaning and ti repairing the roof cracks by cement & sand mortar (1:4), preferably with antishrinkage mortar (to be paid separately) if any, apply two coats along with a IPrimingcoat(two coats of P U Roof Coat and one coat of primer coat compatible with Sqm. i main product as per manufacturers specification) and reinforced with or without 20 ~ gsm GeotextileFleece, ncluding the cost of primer coat and basepreparation, tools & IPlantsbut excluding the cost of scaffolding and stagging complete as per direction of Engineer -in-charge. (Note: If Geotextile Fleece not uesd ,the rate would be reduced by Rs. 5/-per Sqm)
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. UPVC Pipes: 160 mm. Dia.
UPVC Fittings: Plain Tee 160 mm. Dia.
Shoe 160 mm. Dia.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) One Coat Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats) Luxury Quality Gr floor
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 35 mm. thick
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.68 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.70 MB
2911_ii.pdf
Tender Documents • 1.86 MB
BOQ_2393057.xls
BOQ • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .