Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹23,622
Closing Date
7 Oct 2026, 1:00 pm
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
SITC of 58.5 KVA D.G set with AMF Panel and Manual By-Pass System at Haringhata Mahavidyalaya, Haringhata, Nadia
2026_WBPWD_5073918_1
WBPWD/EE/NED/NIQ/e-T/08/ (3rd Call)26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,622
Nadia Electrical Division
21 Sept 2026
21 Sept 2026
9 Oct 2026
21 Sept 2026
7 Oct 2026
23 Sept 2026
23 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, delivery at site on foundation, Testing & commissioning of 58.5 KVA, 415V, 50Hz, 3Ø silent new DG Set with Spl AMF control panel with Bypass arrangement, comprising of Engine, alternator, Base frame, Fuel tank, Battery, CPCB-II approved Engine & Acoustic Enclosure as per detail specification attached (uploaded in the specification section)[Make- JAKSON/Ashok Leyland/Caterpiller/KOEL/Greaves Power] Engine:- Make : JAKSON/Ashok Leyland/Caterpiller/KOEL/Greaves Power. Engine Type : 4 Stroke Diesel Engine RPM : 1500 Rated Power : 47/74.4 Kwe/ BHP Duty : PRIME Cooling : Water cooled with radiator Cylinder : 6 Aspiration : Turbo Charged Fuel Tank Capacity : Capacity 163 Ltrs. [/or as per Manufacturer's standard] Fuel Consumption at 75% rated Load with Radiator or Fan. Fuel Consumption at 100% rated Load with Radiator or Fan. Overload Capacity : 10% overload for one hour for every 12 hours continuous running at full load or better | |||||
| 1.1 | Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine over speed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V/ 24 V starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
Alternator
Make : Stamford/ Leroy Somer
Rating : 415 V., 3Ph. 50 Hz., 58.5 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : screen-protected drip proof with Min.IP-23 degree of protection | - | - | - | - |
| 1.2 | RPM : 1500
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF Panel
Cubical type floor mounted AMF panel made from 14 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 58.5 KVA DG set having following specification/features.
i) 415 V, 125A FP MCCB of Breaking capacity 25/35kA with O/L,S/C,E/F protection and microprocessor based protection release, U/V release etc. with 1 no. 125A FP power contactor-2 sets.[make:Legrand/SIEMENS/L&T/ABB]
iii) In Built manual By-Pass switch with capacity 415V, 125A.
iv) On -delay timer for load change over
v) On-delay timer for engine shut off
vi) Engine On-Off switch (Push button type)
vii) Battery charger complete with voltage regulator, booster selector switch, on-off switch, voltmeter and ammeter for charging the battery from mains. This will be in addition to the battery charging alternator fitted on the engine | - | - | - | - |
| 1.3 | viii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
ix) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
ix) Mode selector for setting the panel on Auto/ Man/ Test Mode
x) Microprocessor based relay with composite meter for digital display of following.
xi) Generator voltage/AC Mains voltage.
xii) Generator Current in all phases
xiii) Frequency
xiv) Power Factor
xv) Energy
xvi)Indication for alternator supply
xvii)Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure. | - | - | - | - |
| 1.4 | Acoustic Enclosure
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustic enclosure must be certified as per CPCB-II norms.
Base Frame
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
Terms & Conditions
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relevant IS specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iii) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competent Authority (As per CPCB-II).
(v) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/OEM.
(vi) The entire set must be warranted at least 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier. | 1 | Set | - | - |
| 2 | Supply & fixing of exhaust gas piping of 102 mm dia MS black class B pipe welded incl. all necessary bend supports and clamps anti vibration mounting insulation of exhaust system with 50 mm thick mineral wool covered with wire mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB) for 58.5 KVA DG set as per direction of EIC. | 20 | Mtr | - | - |
| 3 | S&F special type MS angle iron support structure made of MS angle with flat iron clamp with nuts, bolts & washers etc. for 102 mm. dia exhaust pipe. | 35 | Kg | - | - |
| 4 | S&F rain protection canopy for 102 mm exhaust pipe | 1 | No | - | - |
| 5 | Hire charges for scaffolding by bamboo required rope of square type arrangement for smooth working & carriage of MS black pipe by vertical run & dismantling at the end of work. | 10 | S/V | - | - |
| 6 | Supply & delivery of best quality oil hand pump with 1" dia PVC flexible pipe (12' ft. approx.) | 1 | Item | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_5158971.xls
BOQ • 0.29 MB
form2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .