Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62,439Accepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹68,650.32+₹6,211.32 (9.95%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹65,381
EMD Value
₹1,635
Closing Date
27 Jan 2026, 6:00 pmClosed
Assistant Executive Engineer
O/o The Assistant Executive Engineer PWD Electrical Sub Division Chembukavu,Thrissur-20
DEPOSIT-Setting up of waiting area for bystanders and providing pest control measures in Burns Unit in Government Medical College Hospital Thrissur-work-General Electrical Work
2026_PWD_828898_1
ESDT(ET)113/AEE/25-26
Open Tender
Electrical Works
Percentage
90 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
₹1,635
7 Mar 2026
19 Jan 2026
30 Jan 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
electrification
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
OD253935/2025-2026:od60159/2021_2022 : Supply, installation, testing and commissioning of 400 mm wall fan with metal body and giving necessary connection etc. as required (Havells/cromption/equivalent make)
OD254009/2025-2026:Supply, conveyance, installation, testing, and commissioning of Surface-mounted Round/square (1X1) fitting with high energy efficiency, made of CRCA powder coated sheet .5mm thick with driver with frame, system wattage maximum of 18W, lumen output minimum of 1800lm, power factor>.90, CRI>80, THD <10% with frame.fixed to the ceiling using inbuilt clamps and giving connections with the required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
OD254011/2025-2026:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 225 mm sweep Light Duty Exhaust fan in metal body working on 230v single phase A/C
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1391592.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.10 MB
Tendernotice_2.pdf
PDF • 0.02 MB
Tendernotice_3.pdf
PDF • 0.16 MB
Tendernotice_4.pdf
PDF • 0.05 MB
Tendernotice_5.pdf
PDF • 0.06 MB
Tendernotice_6.pdf
PDF • 0.27 MB
viewsbd.pdf
Tender Documents • 1.63 MB
viewnit.pdf
Tender Documents • 0.02 MB
BOQ_1391592.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .