Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.1 L+₹96,326 (11.9%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹8.6 L
EMD Value
₹9,000
Closing Date
30 Jan 2020, 5:00 pmClosed
The Secretary
Konni gramapanchayat office, Konni
Town hall electrification, Konni
2020_DP_337767_1
P 266/19_20
Open Tender
Electrical Works
Item Wise
30 days
Konni
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Yes
online
₹9,000
Yes
11 Jun 2020
22 Jan 2020
1 Feb 2020
23 Jan 2020
30 Jan 2020
23 Jan 2020
Electrical Items :
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator.
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator.
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
independent plug
3 module PVC box in recess
4 module meetal box in recess
9 module PVC box in recess
3 module white plate
4 module white plate
9 module white plate
6 A SP 1 way switch
6 A Universal socket
6/16 A socket
16 A SP 1 way switch
20A motor starter switch
20 A DP switch with ind
20 mm dia light gauge
25 mm dia light gauge
32 mm dia light gauge
1.5 sqmm 2 run
1.50 sq mm 4 run
2.50 sq mm 2 run
2.50 sq mm 4 run
4.00 sq mm 2 run
4.00 sq mm 4 run
6.00 sq mm 4 run
2.00 mm copper conductor (14 SWG)
2.65 mm copper conductor (12 SWG)
3.155 mm copper conductor (10 SWG)
6 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
6 way (8+18) - three phase double cover (IP 42/43)
12 way single phase double cover (IP 42/43)
63 A four pole mini break isolator
63 A, 4 pole, 30 mA RCCB
40 A, 10 kA, TP MCB (C curve)
40A, 4P Isolator
25 A double pole mini break isolator
25 A, 2 pole, 30 mA RCCB
40 A, 4 pole, 30 mA RCCB
0-32A SP MCB
Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.
Supply and installation of suitable size MS belt type fan clamp as per IS 732 as required.
LED recessed mounted luminaire (RC380B G2 LED35S-6500 PSU OD WH OF M/s Philips or equivalent )
Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
16-20W 1200 mm LED Tube light fitting
Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with 200 mm polished aluminium shade and Dwarf size 11 W BC / ES / E14 retrofit CFLand giving connection etc as required
1200 mm sweep - 5 star rated
32 mm dia with clamps made from 20 x 3 mm MS flat
25w LED outdoor fittings IP 66( Philips, crompton, bajaj, havells or equivalent)
Charges for cutting holes suitable for accommodating exhaust fans of sizes up to 305 mm sweep including plastering, colour washing etc. as required.
300/ 305 mm, single phase heavy duty exhaust fan in metal frame
225mm, single phase light duty exhaust fan in metal frame
450 mm sweep ( Almonard make)
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
Supply and providing RCC covering slab constructed with cement concrete 1:2:4 using 20mm broken stone for reinforced concrete work for the innspexction chamber for earth pit as required
Reinforcement for RCC works , bend tied and placed in position using Tor steel
2 x 25 x 3 mm tinned copper strip
3.15 mm copper conductor (10 SWG)
3.15 mm bare copper conductor (10 SWG)
2.00 mm (14 SWG)
3.15 mm (10 SWG)
25 x 3mm brass bolt & nut
25 x 6 mm brass bolt & nut
15 mm dia
Supply and fixing three phase PVC (SMC) meter box directly on wall (Sintex 6535)
63 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
63 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over switch
Fabrication, supply, conveyance and fixing frame work made out of suitable size angle iron/ flat cut and welded to shape of suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gear, fixed to wall using suitable size anchor bolts or grouted to wall, making good the damages, colour washing etc as required
63 A, 415 V Backelite fuse fitting
63 A, bolted offset tag type fuse link of size A1L
63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
MS anchor bolt type iron hook 8mm size for binding service wire
JEBIN JOHN MG POWER CONTROLS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .