Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹15.5 L+₹54,775 (3.65%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹16.7 L+₹1.7 L (11.3%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹17.4 L
EMD Value
₹34,700
Closing Date
11 Aug 2022, 6:00 pmClosed
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
SPL REPAIR TO MOTORIZED DOOR OF WSI HANGAR HAVING BUILDING NUMBER P-217 AT RALAWAS AND SPECIAL REPAIR TO PATH LIGHTS AT TECH AREA NAGTALAO UNDER GE BANAR IN ARMY AREA JODHPUR
2022_MES_529458_2
8822/02/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹34,700
Yes
15 Sept 2022
18 Jul 2022
13 Aug 2022
18 Jul 2022
11 Aug 2022
28 Jul 2022
Amount
Disconnecting/taking down old existing unserviceable Panel mounting socket angled 63/32/16 Amps any type all as directed.
Dismantling/taking down old existing unserviceable earthing set all as directed.
Disconnecting/taking down old existing unserviceable MCCB any type all as directed.
Disconnecting/taking down old existing unserviceable cable any size any type all as directed.
Disconnecting/taking down old existing unserviceable OPR (Optimized Pulse Rod) complete including connected items any type all as directed.
Supply and Fixing and Panel mounting industrial socket angled 63 Amps 3 Phase with (N+E) complete with on panel with all connection as per site requirement as per dirtected
Supply and Fixing and Panel mounting industrial socket angled 32 Amps 3 Phase with (N+E) complete with on panel with all connection as per site requirement as per dirtected
Supply and Fixing and Panel mounting industrial socket angled 16 Amps 3 Phase with (N+E) completed with on panel with all connection as per site requirement as per dirtected
Supply and Fixing MCCB 4 pole 160 Amps 415Vajustable type with breaking capacity 36 KA completed complete all as specified
Supply and Fixing MCCB 4 pole 125 Amps 415Vajustable type with breaking capacity 36 KA complete all as specified
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron strip 32x6mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed by Engr-in-Charge
Dismantling/taking down of motorised hangar door of over all size 27m x 8m having 08 equal leafs (2 Nos static and 6 Nos movable) and reinstallation/refixing at same location by means of required machinery i.e Hydro Cranes, mechanical Jacks, scafolding etc according to latest/modern technique considering all safety measures comprising repair /replacement of the following parts:-
Straightening of door leaf by repairs/replacement of defective parts, alignment of all top & bottom tracks, replacement of all top & bottom ball bearings of existing size/specifications including oiling/greasing and provision of arrangement of iron brush attached with bottom of leaf to clean the track complete - 8 leaf
Replacement of indoor type fully enclosed weather protected 03 phase 415 volt motor and its gear assembly of suitable capacity including cable connections of requisite size & lengths complete - 02 sets
Replacement of indoor type fully enclosed panel (CPRI approved makes) of suitable size as directed by EIC consisting LED. Push buttons/sustenses to control forward/reverse movement and stop functions, overload protecion, safety switches, key sepectars with all suitable size connectors/safety factors complete - 02 sets
S & F in replacement limit swtiches for auto power cut fixed at suitable distance of master leaf both in opening and closing situations - 02 sets
S & F in replacement idle breaking system to be attached with motor gear system via chain sprocket assembly derive, fastoon cable carrier arrangement, mechanical buffers, heavy duty cleats, connectors, EPDM gaskets at centre leafs, auto track cleaners at bottom of leaf complete - 2 Sets
S & F in replacement of mannual deducting system for any emergency at a approachable height by twisting the mechanism with handle shaped L.N key - 2 Nos Note: The scope of repair/replacement involve appripriate mechanism, gear operated scofolding/Jacks etc. Hence it is advised that bidders must visit the site of work to ascertain the nature of work before quoting rates and no compensation will be allowed at later stage.
Supply installation testing and commissioning of lightening protection system Early Streamer Emission (ESE) lightening protection Air terminal OPR (Optimized Pulse Rod) complies with NF C-17-102 standards complete all as specified and directed by Engr-in-Charge. Make – ABB Model OPR-30 and equivalent in Alstom/OBLUM Note:-This work will be carried out at high rised building
Supply and fix stainless steel 3 M mounting mast plus 2 m , 30 mm dia with guy wire and base plate fabricated with support structure and guying kit provided with suitable mounting base plate having provision for fixing of optimised pulse rod and arrangement for down conductor of lightening protection system all as specified and directed by Engr-in-Charge.Make:- Cat Part No Mast 3 M & MAST 2M30 of ABB or its equvalent in Alstom/OBLUM
Supply, fixing, testing and commissioning of lightening stroke counter working electro mechanically without any power supply. Eqpt should have capacity of counting lighting stroke of 0.4 KA to 150 ka, all as specified and directed by Engr-in-Charge. Make- LS Counter of ABB or its equivalent in Alstom/Oblum
S&F in replacement of thermo-plastic cable junction box IP 65 with plain walls of size 210x310x116 mm and making suitable size hole for cable entry complete with cable terminals/connector with 3 phase DIN rail and other fitting fixed on poles with MS flat iron nut bolts, washeres and double compressor metal glands of suitable size etc. complete all as specified.
Supply and laying of single core FRLSH multi stranded copper cable down conductor of size 70 sqmm incl mounting accessories and clamps with suitable fixing material all as directed at site.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified.
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations complete all as specified.
M&L for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for UG cable protection complete all as specified.
Supply and laying in replacement 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor served with an inner sheathing of PVC tap armoured with galvanised steel wire or strip and over PVC sheathed of size 4 core 16 sqmm complete all as specified.
Supply and fix in replacement LED bollard light fitting 15W 230V 50hz with energy saving environment friendly long life excellent light out put with high power throught robustly designed aluminum body IP-65 with base plate easy to install complete including connection through cable connected upto junction box as per site requirment complete all as specified.
Supply and fix in replacement junction box wall mounted three phase 440 Volts thermo plastic poly carbonate enclosure of size 200x160x98 MM, front openable weather proof, dust proof, water proof halogene free and having internally embeded gasket-04 Nos aluminium busbar of 63 Amps rating mounted on insulators including MCB TNP 25 Amps 01 No with the provisioning of bottom cable entry with cable glands for connecting street light fittings all as specified and as directed by Engineer-in-Charge.
Material and labour for PCC 1:3:6 type C1 using 20mm graded aggregate as in copping /collar of bollard poles and foundation assembly etc complete all as specified and directed.
vinayandsons
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .