Loading…
Loading…
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
20 Jul 2026, 1:00 pm
Registrar, Jai Narain Vyas University, Jodhpur
Registrar, Jai Narain Vyas University, Jodhpur
AC Installation for Various Office in Central Office at JNV University, Jodhpur. UBN No. JNV2627WSOB00034
2026_JNU_563741_1
JNVU/BC/2026-27/1268 Dated 07/07/2026
Open Tender
Miscellaneous Works
60 days
Registrar, Jai Narain Vyas University
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
1000 Registrar JNVU Jodhpur and 500 MDRISL Jaipur
₹20,000
Yes
10 Jul 2026
10 Jul 2026
20 Jul 2026
10 Jul 2026
20 Jul 2026
16 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year Original Equipment Manufacturer (OEM) warranty of both compressor and Printed Circuit Board (PCB).
(i) Cooling capacity 5000-5300 Watt, ISEER not less then 3.8 | - | Each | 36,822 | - |
| 2 | Cooling capacity 6800-7000 Watt, ISEER not less then 3.8 | - | Each | 50,605 | - |
| 3 | Supply, Installation, Testing and Commissioning of Inverter type Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, +/- 10% 50 Hz ,1 /3 phase AC supply, capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll /rotary/twin rotary compressor etc. complete as required.
Cooling Capacity 6900-7000 Watt ISEER not less then 3.5 | - | Each | 88,622 | - |
| 4 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia
50 mm dia per running inch length | - | Per Inch | 67 | - |
| 5 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. 20mm | - | Rm | 131 | - |
| 6 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. | - | Each | 542 | - |
| 7 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810.
(i) Un Armoured 2 core x 1.0 Sq.mm | - | Rm | 55 | - |
| 8 | Un Armoured 4 core x 2.5 Sq.mm | - | Rm | 187 | - |
| 9 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. as required. | - | Kg | 2,203 | - |
| 10 | P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required.
20 amp, (2P + E), 2 Module | - | Each | 1,570 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
SPPP_removed_mergedNIT8.pdf
Tender Documents • 18.60 MB
BOQ_1021606.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid