Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoted rate | |
| 2 | L2₹9.5 L+₹2.0 L (26.1%)Rejected-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L2 | Rejected-AOC Not accepted since higher quoted rate | |
| 3 | L3₹10.2 L+₹2.6 L (35.0%)Rejected-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L3 | Rejected-AOC Not accepted since higher quoted rate | |
| 4 | L4₹10.3 L+₹2.7 L (36.1%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L4 | Rejected-AOC Not accepted since higher quoted rate | |
| 5 | L5₹11.4 L+₹3.8 L (50.8%)Rejected-AOC | L5 | Rejected-AOC Not accepted since higher quoted rate |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
1 Apr 2021, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR REPLACEMENT OF ELECTRIC WIRING WITH FITTINGS AND FIXTURES SUB MAIN WIRING DBS WITH EARTHING IN MD ACCN AT MIL STN GANDHINAGAR
2021_MES_431949_1
GE(A)/GNR/TOKEN/10 of 2021-22
Open Tender
Civil Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹24,000
Yes
30 Apr 2021
19 Mar 2021
3 Apr 2021
19 Mar 2021
1 Apr 2021
26 Mar 2021
19 Mar 2021 - 25 Mar 2021
Amount
Taking down carefully copper/aluminum point wiring (light, fan,socket or power) complete,including fixture and fitting such as as switches, ceiling roses, pendants, regulators, sockets,etc excluing light fittings etc,removing materials to store for keeping in safe custudy or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surface of walls, ceiling, floor etc to match with the existing surface.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick laminated hylam sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One multi purpose socket 5 Amps, Independent board.
(c) One multi purpose socket 5 Amps, on the same board.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
S&F in repair switch piano, flush button single pole, one way 5 Amps complete all as specified and directed.
S&F in repair socket outlet 2 in1, 3 pin, 5 Amps, flush type complete all as specified and directed.
S&F in repair socket outlet multipurpose, 3 pin, 5 &15 Amps flush type complete all as specified and directed.
S&F in repair switch piano flush button single pole, one way 15 Amps complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 5 Amps flush type complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 5 & 15 Amps flush type complete all as specified and directed.
S&F in repair Ceiling rose, PVC/poly carbonate,isolated body three terminals,complete all as specified and directed
M & L for ceiling fan regulators, Electronic step type type, AC, 230 Volts complete all as specified and directed.
S&F in repair lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S &F fix in repair Distribution Board SPN 8 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
S & F in repair Distribution Board Power line VTPN , 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, suitable for 4 pole MCCB 63 Amps for incoming supply and 12 Nos single pole MCBs 6 to 32 Amp for out going supply complete all as specified and directed.
S & F in repair MCB’s single pole, 6 to 32 Amps 240 volts with ‘C’ curve,10KA , fixed in sheet metal board complete including connecting.
S & F in repair MCB’s SPN 32 Amps 240 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
S&F, in repair, MCCB Three pole and neutral 10KA, 63 Amps, 415Volts. complete all as specified and directed.
S&F, in repairs, LED light fitting, 1x20W, 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fix LED light fitting 1 x 10 W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
Supply & Fix in repair LED type Bldg security light fittings, IP-66, 25W, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics including taking out old unsv fitting of any type complete all specified and directed.
M & L in replacement sub-main wiring with 2 single core 4 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC casing and capping ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 4.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length.
Supply, installation, commissoning and testing, in repair, factory made, LT Metal Box, wall mounted board made out of CRCA sheet of 2 mm thick indoor type totally enclosed weather, dust and vermin proof with front opening hinged door and locking arrangement mounted on MS flat iron (40x6 mm and 6" long) 04 No clamp welded to 40mm x 40mm x 6mm size angle iron frame alround panel body duly grouted on wall, 415 volts 3 phase, 4 wire AC 50 HZ having aluminium bus bar 25mm x 10mm for phase and the neutral insulated with PVC sleeves, space for fixing single phase KWH electric meter of suitable capacity 04 Nos, copper lugs, spacers, mounting channels, rubber gasket, locking knobs, hylam sheet pieces, PVC shrinkable sleeves, buts and bolts, washers etc and suitable size single core copper wire connections, suitable compartments and epoxy powder spray paint with primer complete all as specified including the following accessories including taking down old unserviceable distribution board, taking down and refixing serviceable electric KWH meter in new panel (all as per sample) complete comprising the followings :- (a) Incoming supply:- (i) MCCB, 415 Volts, 4 Pole, 25 KA breaking capacity of 63 Amps - 01 No. (ii) R-Y-B phase, LED indicating lamp - 03 Nos (iii) 20 Amp HRC control fuse with fuse link - 03 Nos, (iv) 200 Amp TPN main aluminium bus bar (b) Outgoing supply:- (i) MCB, SPN, 40 Amp, 10 KA = 04 Nos (ii) Space for mounting single phase energy meter - 04 Nos (iii) Copper cable 6 Sqmm wire and open terminals for all feeders.
M&L for insulation Resistance test report ,as per performa given by the department,all equipment and worker(Electrician) for the said test will be provided by the contractor. After completion of the test reports will be submitted to the MES Office complete all as specified and directed.
Electromech Engineers
M/S PRASHANT BENIWAL
ARTI CONSTRUCTION
Tech Serve Solutions
ALPINE CONSTRUCTIONS
ALBA AC AND REF SERVICES
Shreeganesh Construction
DATTA SURYAKANT CHAUDHARI
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .