Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.6 L+₹64,300 (7.17%)Rejected-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹9.6 L+₹65,800 (7.34%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | L3 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
1 Jul 2023, 6:00 pmClosed
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2023_MES_595205_2
8720
Open Tender
Civil Works
Item Rate
270 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹20,000
Yes
9 Aug 2023
5 Jun 2023
3 Jul 2023
5 Jun 2023
1 Jul 2023
12 Jun 2023
5 Jun 2023 - 12 Jun 2023
Amount
Comprehensive maintenance/Servicing of air conditioners of Window type AC 1.0/1.5 Ton capacity installed at various location, including oiling/greasing the blower motor, bearings etc, cleaning the air filter pad, evaporator, condensor coils filter externally to remove the dust, replacement of defective parts all as directed by Engr-In Charge (Comprehensive maintenance also includes dismantling of outer/inner unit of spilit AC/window AC of any capacity repairing and replacing defective components,testing, refixing the AC properly to same place). Note:- Spare parts, gas charging shall be measured and paid seperately under relevant items mentioned below as per the requirement of repair of the installations.)
All as per item no 1 but Split type AC 1.5 Ton capacity
All as per item no 1 but Split type AC 2.0 Ton capacity
Supply and fix in repair PCB card of capacity 1.5 Ton for split AC for Air conditioner of existing capacity, model size.
All as per item no 4 but PCB card of capacity 2.0 Ton for split AC
Supply only Remote hand set for split AC upto 1.5 Ton AC capacity
Supply only Remote hand set for split AC upto 2 Ton AC capacity
Supply and fixing in replacement of Blower motor 1/5 HP single phase F.H.P. type 230 volts 50 Hz for window type AC including connecting, testing & commissioning(as per site model). Make : GE/Polar/Crompton
Supply and fixing in replacement of Air filter washable made of synthetic fiber, 3mm thick for window type AC 1.5 Ton capacity all as specified
Supply and fixing in replacement of Air filter washable made of synthetic fiber, 3mm thick for window type AC 2.0 Ton capacity all as specified
Supply and fixing in replacement of Starting capacitor suitable for window/split type AC capacity upto 2.0 Ton
Supply and fixing in replacement of Running capacitor suitable for window /split type AC capacity upto 2.0 Ton
Supply and fixing in replacement of Thermostat switch suitable for window type AC 1.5 Ton capacity with temperature differential 2.5 + 1 C and working range 150C to 300C
Supply and fixing in replacement of Starting relay suitable for window type/Split AC 1.5 Ton capacity
S&F in replacement of Starting relay suitable for window type/Split AC 2.0 Ton capacity
S&F in replacement of Rotary switch for window type AC 1.5 Ton capacity
S&F in replacement of Rotary switch for window type AC 2.0 Ton capacity
S&F in replacement of Front grill PVC of any make/type of window type AC 1.5 Ton capacity
S&F in replacement of Valve 1/2", 1/4" and 5/8" for split AC upto 2 Ton capacity
S&F in replacement of Puff insulation of copper pipe 5/8" (ID) for split AC
S&F in replacement of Fan/Blower blade for split type AC upto 1.5 Ton capacity all as specified and directed by Engr-In-Charge
S&F in replacement of Blower motor for indoor unit of 1.5 Ton capacity split type AC. Make : ISI marked
S&F in replacement of Blower motor for indoor unit of 2.0 Ton capacity split type AC. Make : ISI marked
S&F in replacement of Condensor fan motor for outdoor unit of split type AC 1.5 Ton capacity
S&F in replacement of Condensor fan motor for outdoor unit of split type AC 2.0 Ton capacity
S&F in replacement of Copper pipe of size 1/4" from outdoor unit to indoor unit
S&F in replacement of Copper pipe of size 1/2" from indoor unit to outdoor unit
S&F in replacement of Copper pipe of size 5/8" from indoor unit to outdoor unit
M & L for charging of gas refrigerant in Air conditioner of capacity up to 2.0 Ton of any make including cleaning of suctions & discharge refrigerant line with CTC solution and removing the leakage in line complete all as directed by Engr-in-charge
Disconnecting & taking down condensing unit (outdoor) of split type AC 1.5 Ton capacity of any make, and S&F 'R' compressor 1.5 Ton capacity including all connecting work like cutting brazing, flushing etc, balancing the condensor fan including gas charging, refixing, connecting, testing & commissioning all as specified
All as per item no 30 but but for 2.0 Ton capacity
S & F Indoor unit complete for split AC of any make as site requirement of capacity upto 2.0 ton with all accessories including fitting and necessary connection all as specified and directed by Engr-in-Charge.
S & F outdoor unit complete for split AC of any make as site requirement of capacity upto 2.0 ton with all accessories including all fitting and necessary connection all as specified and directed by Engr-in-Charge.
Dismantling split type AC of any size from the site and refixing the same at another site complete all as directed by Engr-In-Charge
All as per item No 34 above but for window type AC of any size and capacity
Comprehensive maintenance/Servicing of water cooler of existing type make and model installed at various location, including oiling/greasing the blower motor, bearings etc, evaporator, condensor externally to remove the dust, replacement of defective parts all as directed by engineer in charge. ( Comprehensive maintenance also includes transportation of water cooler at workshop for repair after repairing the same will be re-installed properly to same place). Note : Spare parts, gas charging shall be measured and paid separately
S&F in repair Water tray stainless steel with provision of drain plug suitable for water cooler of any make and capacity
S&F in repair Stainless steel water tap self closing type existing model & size 15mm dia suitable for water coolers of any make & type. Make : Parco/Prayag
S&F in repair Float valve assembly with brass ferrule 15mm dia and PVC ball suitable for water cooler upto 150 ltrs and desert cooler upto 400 cfm. Make : Prayag
S&F in repair fan motor single phase 230 volts 1/32 HP 50 Hz suitable for water cooler of any make including testing & connecting
All as item No 40 but capacity 1/16 HP
S&F in repair Thermostat switch suitable for water cooler upto 150 ltrs capacity connecting & testing. Make : Renutrol/Indfoss
S&F in repair Over load relay suitable for water cooler upto 150 ltrs capacity including testing, connecting & commissioning complete all as directed by Engr-in-charge. Make : Renutrol/Shri Ram
S&F in repair PVC connections 15mm size with PVC washers & nuts of length 450mm and both ends for water cooler
S&F in repair Water cooler drain PVC flexible pipe of 25mm dia size
S&F in repair Door gasket of water cooler
S&F in repair Condensor of Fan motor for water cooler of any make and capacity
S&F in repair Running Capacitor size as per site requirement for water cooler of any make and capacity
S&F in repair Starting relay with overload protector for water cooler of any make and capacity
M & L for painting (Spray with gun) of water cooler externally only with one coat of synthetic enamel paint of existing shade approved make, after cleaning the spots/dust and write MES and SM no of items black back ground and write letter vice varsa as per site requirement etc as directed by Engr-in-charge
M & L for charging of refrigerant after cleaning the suction & discharge pipe with CRC solution and removing the leakage in water cooler upto 150 ltr capacity complete all as directed by Engr-in-charge
S & F in replacement 'R' compressor for water cooler 150 ltrs from authorized dealer including connected works like cutting and brazing the refrigerant pipe complete including gas charging all as specified and directed by Engr-in-charge. Make : Copeland/Shri Ram/Carrier/LG/Bluestar
All as per item item No 52 but 80/40 ltrs capacity
Disconnecting and taking down the water cooler and transporting to work shop dismantling the compressor, condensor, blower motor, cutting the perished, rusted bottom portion of water cooler, M & L for refixing/welding new bottom portion upto 20cm height with 2 mm thick sheet and angle iron frame of suitable size of angle iron and painting new steel work with 2 coats of synthetic enameled water proof paint over a coat of red oxide, refixing the compressor condensor, blower motor, including cutting welding/brazing the refrigerent pipes etc all as directed by Engr-in-charge
Comprehensive maintenance/Servicing of Refrigerator /Deep Freezer of any make any model installed at various location, including oiling/greasing the blower motor, bearings etc, evaporator, condensor externally to remove the dust, replacement of defective parts all as directed by Engr-in-charge. (Comprehensive maintenance also includes transportation of Refrigerator (if required) to workshop for repair after repairing the same will be re-installed properly to same plave)
S & F in repair Thermostat switch three speed complete as per model/ make of site all as specified and directed by Engr-in-charge
S & F in repair of door gasket as per site model/ make for Refrigerator
S & F in repair Over load relay as per site model/ make for Refrigerator
S & F in repair Cooling coil motor single phase 230 volts for Refrigerator
S & F in repair Vegetabe tray as per site model/ make for Refrigerator
S & F in repair Racks of suitable size as per site model/ make for Refrigerator
S & F in repair Inner lamp of refrigerator
S & F in repair Biometal for double door refrigerator as per site model/ make
S & F in repair Heater for double door Refrigeratoras per site model/ make
S & F in replacement 'R' compressor for Refrigerator of capacity 160-210 ltrs from authorized dealer including connected works like cutting and brazing the refrigerant pipe complete including gas charging all as specified and directed by Engr-in-charge. Make : Copeland/Shri Ram/ Carrier/ LG/ Bluestar
All as per item No 61 above but for deep freezer for 210 Ltrs to 310 Ltrs
Comprehensive maintenance for servicing of inner size of the desert cooler including oiling/greasing of fan motor, bearings etc and remove the dust & refixing the same at its original position all as directed by Engr-in-charge
S & F in repair Aluminium fan blades suitable for upto 450mm sweep fan of any make & type as directed & specified for Desert Coolers
S & F in repair Running capacitor 3.15/4.0 mfd suitable for fan motor of desert cooler complete all as specified
S & F in repair Submersible pump complete 1/70 HP single phase 230 volts 50 Hz for Desert Coolers
S & F in repair of spares for Desert Coolers like Wood wool pads for Desert Coolers
S & F in repair Fan motor complete for Desert Coolers
S & F in repair Rotary switch for Desert cooler
M & L for painting of desert cooler capacity upto 4000 CFM with one coat of approved synthetic enamel paint inside & outside including fan/fan blade/ brackets after scrapping the rustk, pealed off paint and preparation of surface complete all as specified and write MES and SM no of items black back ground and write letter vice varsa as per site requirement
Supply, installation and testing of commercial evaporative type Air cooler (Desert Cooler) metallic/Iron body 16 SWG guage metal sheet having capacity of 4000 cum/hr, copper wound motor (make - Usha / Khaitan / CG), single phase, 230 Volts operated and water storage capacity not less than 70 ltrs, , mosquito proofing net for all sides including fixing arrangements with suitable size of MS angle iron stand complete all as specified and directed.
Supply, installation and testing of commercial evaporative type Air cooler (Desert Cooler) Plasticbody, 230 Volts, single phase, having capacity of 5000 cum/hr (450mm sweep), water storage capacity not less than 70 ltrs, mosquito proofing net for all sides including fixing arrangements with suitable size of MS angle iron stand with wheel arrangements complete all as specified and directed.
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps
Gayatri Associates
Dagli Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .