Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance | ₹2.0 L | L1 | Accepted-Finance Financial Bid Qualified |
| 2 | L2₹2.0 LAccepted-Finance | ₹2.0 L | L2 | Accepted-Finance Financial Bid Qualified |
| 3 | L3₹2.0 LAccepted-Finance | ₹2.0 L | L3 | Accepted-Finance Financial Bid Qualified |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
26 Aug 2021, 5:00 pmClosed
E.E., E.T.D.-II, Bareilly
Hydle Colony, Rampur Garden, Bareilly
Repairing of 132 KV Gas circuit breaker at 220 KV S/S Dohna under ETD-II Bareilly
2021_UPTCL_612378_1
Short Term E-Tender No / 07 /ETD-II / (B) /2021-22
Open Tender
Electrical Works
10 days
Bareilly
Please Refer in Tender documents
2 documents required · 2 mandatory
₹590
Ac No 0043002100061489 IFSC PUNB0004300
₹2,000
27 Aug 2021
20 Aug 2021
27 Aug 2021
20 Aug 2021
26 Aug 2021
20 Aug 2021
Amount
Inspection and rectification of gas leakage of 132 KV SF-6 CB, CGL make spring type of 132 KV Transfer bus coupler bay at 220 KV S/S Dohna. The job includes opening of pole assembly from upper and lower terminal flanges. Dismantling of pole of 132 KV SF-6 circuit breaker of 132 KV Transfer bus coupler bay at 220 KV S/S Dohna for attending the gas leakage. Cleaning of all grooves of flanges and porcelain with petrol, scrubber pad and acrylic solution. Replacement of all O-ring of the pole then evacuation of pole upto 760 mm Hg. After testing of vacuum for 12 Hrs. And satisfactory result, refilling of SF6 gas upto required level. Erecting of pole after attending the gas leakage checking of proper operation of CB from local and remote.
Inspection and rectification of gas leakage of 132 KV SF-6 CB, CGL make spring type of 40 MVA T/F-I at 220 KV S/S Dohna. The job includes opening of pole assembly from upper and lower terminal flanges. Dismantling of pole of 132 KV SF-6 circuit breaker of 40 MVA T/F-1 at 220 KV S/S Dohna for attending the gas leakage. Cleaning of all grooves of flanges and porcelain with petrol, scrubber pad and acrylic solution. Replacement of all O-ring of the pole then evacuation of pole upto 760 mm Hg. After testing of vacuum for 12 Hrs. And satisfactory result, refilling of SF6 gas upto required level. Errection of pole after attending the gas leakage checking of proper operation of CB from local and remote.
M/s S.S. Refregeration
LASHANI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid