Loading…
Loading…
Tender Value
₹55 L
EMD Value
₹55,000
Closing Date
3 Jul 2026, 6:00 pmClosed
Deputy Municipal Commissioner
REPAIRING AND MAINTENANCE WORK OF VARIOUS GARDEN, LAKE GARDEN AND SHANTIKUNJ AT D.T.P.S NO.33 (TALANGPUR-UMBER), D.T.P.S NO. 59 (UNN), D.T.P.S NO. 67 (JIAV-SONARI-GARDEN) IN SOUTH ZONE -B (KANAKPUR) SURAT.
317214
DMC/SZ-B/01/2026-27,Work No. 03
Open
Repair and Maintenance
Works
Surat
3 documents required · 3 mandatory
₹2,832
Commissioner, Surat Municipal Corporation
₹55,000
24 Jun 2026
24 Jun 2026
24 Jun 2026
3 Jul 2026
24 Jun 2026
SN ITEM Unit QTY Without GST & TOTAL
Excavation for foundation includ.sorting out & stacking of useful materials &
disposing of the excavated stuff upto 50 mt. Lead & all lift, watering etc.
Comp. (A) Loose or Soft soil
Executed With Mechanised Efforts / Machinaries
(1) Up to 1.5 Mt. depth C.M. 15.00 123.13
Excavation for foundation includ.sorting out & stacking of useful materials &
disposing of the excavated stuff upto 50 mt. Lead & all lift, watering etc.
Comp. (A) Loose or Soft soil
Executed With Manual Labours
(1) Up to 1.5 Mt. depth C.M. 15.00 212.52
Providing & Laying C.C1:5:10 (1cement :5coarse sand :10 graded stone agg.
m.m Nominal size )& curing comp. excl. cost of from work in :Foundation & Plinth
Providing & laying cement concrete 1:4:8 (1 cement:4 coarse sand:8 graded stone
4 agg. 40 mm nominal size) & curing comp. excl.cost of form work in (A) Foundation C.M. 5.00 2,769.69
Providing & laying C.C 1:3:6 (1cement :3 coarse sand :6 Crushed stone agg 20m.m
Nominal size)&curing comp. excl. cost of form work in :(a) foundation & Plinth
Providing & laying cement concrete 1:1.5:3 (1 cement:1.5 sand:3 graded
stone agg. 20 mm nominal size)& curing comp. Includ.cost of form work but exclu.
Cost of reinforcement for reinforced concrete work in : (A) Foundation, footing,
Base of columns and Mass concrete.
Providing & laying ordinary cement con.1:1.5:3 (1cement:1.5sand: 3 graded stone
agg. 20 mm nominal size) finishing smooth curing etc. comp. Incld. Cost of form
work but excl. Cost of reinforcement for R.C.C. Work in : Up to G.L./P.L. (A)
(1)Having c/s area up to 0.08 s.mt C.M. 5.00 12,844.32
(2) Having c/s area more than 0.08 sq. mt. & upto 0.12 sq.mt C.M. 5.00 11,166.97
(3) Having cross sectional area more than 0.12 sq. mt. C.M. 5.00 9,201.68
(1)Having c/s area up to 0.08s.mt C.M. 5.00 9,102.61
(2) Having c/s area more than 0.08 sq. mt. & upto 0.12 sq.mt C.M. 5.00 8,174.41
(3) Having cross sectional area more than 0.12 sq. mt. C.M. 5.00 7,086.88
Providing & fixing IS Mark TMT Bar FE 500D reinforcement for R.C.C. work incl.
bending, binding & placing in position etc. comp. Upto G.L./P.L.
Brick work using common burnt clay building bricks having crushing strength not
9 less than 35 kg./Sq.Cm. in foundation and plinth in Cement C.M. 10.00 4,441.11
Mortar 1:6 (1- Cement : 6 -fine sand)(C) Fly Ash Bricks
Filling available excavated earth (excluding rock) in trenches. plinth, sides of
10 foundations etc. in layers not exceeding 20 cm. in depth consolidating each C.M. 130.39 136.92
disposited layer by ramming and watering.
Filling in foundation and plinth with murrum or selected soil in layers of 20cm.
thickness including watering, ramming and consolidating etc. complete.
20mm thick sand faced cement plaster on walls upto height 10 metres above
ground level consisting of 12mm thick backing coat of C.M. 1:3
(1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1- sand)
Providing & laying ordinary cement con.1:1.5:3(1cement:1.5sand:3 graded
graded stone agg. 20 mm nominal size) finishing smooth curing etc. comp.
Incl.. Cost of form work but excl. Cost of reinforcement for R.C.C. Work in :
(1)Having c/s area up to 0.08 s.mt- Ground Floor C.M. 0.50 12,844.32
First Floor C.M. 0.50 12,885.28
Second Floor C.M. 0.50 12,926.24
Terrace (third) Floor C.M. 0.50 12,967.19
(2) c/s area more than 0.08sq. mt. & upto 0.12 sq.mt - G.F C.M. 0.50 11,166.97
First Floor C.M. 0.50 11,207.92
Second Floor C.M. 0.50 11,248.88
Terrace (third) Floor C.M. 0.50 11,289.83
(3) Having cross sectional area more than 0.12 sq. mt. -- G.F C.M. 0.50 9,201.68
First Floor C.M. 0.50 9,242.63
Second Floor C.M. 0.50 9,283.59
Terrace (third) Floor C.M. 0.50 9,324.54
(1)Having c/s area up to 0.08s.mt- Ground Floor C.M. 0.50 9,102.61
First Floor C.M. 0.50 9,143.56
Second Floor C.M. 0.50 9,184.52
Terrace (third) Floor C.M. 0.50 9,225.47
(2) Having c/s area more than 0.08 s.m. & upto 0.12 s.m - G.F C.M. 0.50 8,174.41
First Floor C.M. 0.50 8,215.36
Second Floor C.M. 0.50 8,256.32
Terrace (third) Floor C.M. 0.50 8,297.27
(3) Having cross sectional area more than 0.12 sq. mt. -- G.F C.M. 0.50 7,086.88
First Floor C.M. 0.50 7,127.84
Second Floor C.M. 0.50 7,168.79
Terrace (third) Floor C.M. 0.50 7,209.75
(2) Slabs having more than 8cm. and upto 10 cm. Th'.- G.F C.M. 0.50 7,984.42
First Floor C.M. 0.50 8,025.37
Second Floor C.M. 0.50 8,066.33
Terrace (third) Floor C.M. 0.50 8,107.28
(3) Slabs having more than 10 cm. & upto 13 cm. Th'.- G.F. C.M. 0.50 7,396.96
First Floor C.M. 0.50 7,437.92
Second Floor C.M. 0.50 7,478.87
Terrace (third) Floor C.M. 0.50 7,519.83
(4) Slabs having more than 13 cm. Thickness -- G.F C.M. 0.50 6,813.01
First Floor C.M. 0.50 6,853.96
Second Floor C.M. 0.50 6,894.92
Terrace (third) Floor C.M. 0.50 6,935.87
(D) LINTELS: -- G.F C.M. 0.50 9,982.37
First Floor C.M. 0.50 10,023.32
Second Floor C.M. 0.50 10,064.28
Terrace (third) Floor C.M. 0.50 10,105.23
(E) CHAJJAS: -- G.F C.M. 0.50 5,576.81
First Floor C.M. 0.50 5,617.76
Second Floor C.M. 0.50 5,658.72
Terrace (third) Floor C.M. 0.50 5,699.67
Providing & laying ordinary cement con.1:1.5:3(1cement:1.5sand:3 graded
graded stone agg. 20 mm nominal size) finishing smooth curing etc. comp.
Incl.. Cost of form work but excl. Cost of reinforcement for R.C.C. Work in :
(A) Stair cases including landings etc.
Ground Floor C.M. 1.00 7,698.11
First Floor C.M. 0.00 7,739.06
Second Floor C.M. 0.00 7,780.02
Terrace (third) Floor C.M. 0.00 7,820.97
(B) Vertical and horizontal fins
Ground Floor C.M. 1.00 11,613.07
First Floor C.M. 0.00 11,654.03
Second Floor C.M. 0.00 11,694.99
Terrace (third) Floor C.M. 0.00 11,735.94
Providing & fixing IS Mark TMT Bar FE 500d reinforcement for R.C.C. work
incl. bending, binding & placing in position etc.comp.---Ground Floor
First Floor Kg. 0.00 78.34
Second Floor Kg. 0.00 79.39
Terrace (third) Floor Kg. 0.00 80.44
Brick work using common burnt clay building bricks having crushing strength not
less than 35 kg./Sq.Cm. in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(C)
First Floor C.M. 0.00 5,018.55
Second Floor C.M. 0.00 5,307.27
Terrace (third) Floor C.M. 0.00 5,595.99
Half brick masonry in common brunt clay building bricks having crushing
17 strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 - coarse S.M.
sand ) in foundation and plinth (C)Fly Ash Bricks
Ground Floor S.M. 10.00 712.81
First Floor S.M. 10.00 719.37
Second Floor S.M. 10.00 725.94
Terrace (third) Floor S.M. 10.00 732.50
Uncoursed rubble masonary with hard stone of approved quality in
18 foundations and plinth in cement mortar 1:6 (1 Cement : 6 sand) including C.M. 10.00 2,586.61
leveling up etc. complete.
Pointing on Coursed stone masonary with cement mortar 1:3 (1 cement : 3 Sand) --
-(A) Flush Pointing
(B) Ruled Pointing S.M. 100.22 105.24
Pointing on Uncoursed stone masonary with cement mortar 1:3 (1 cement :
Sand) ---(A) Flush Pointing
(B) Ruled Pointing S.M. 108.81 114.25
Providing Rubble Pitching with hard stone of approved quality in cement
21 mortar 1:6 (1 Cement : 6 Coarse sand) including leveling up ,Curing etc. C.M.
complete excluding pointing
Providing and filling rubbles including hand packing and filling interstices with
quarry spalls behind abutments and between returns as directed.
Providing upto floor two level precast cementconcrete jali or grill 1:2:4 mix (1-
Cement : 2- coarse sand : 4-graded stone aggregate 6mm nominal size) reinforced
with 1.6 mm dia. Mild steel wire including roughening,cleaning, fixing and finishing
in cement mortar 1:3 and curing complete. (B) 40mm thick. Ground Floor
First Floor S.M. 10.00 752.39
Second Floor S.M. 10.00 762.85
Terrace (third) Floor S.M. 10.00 773.32
Providing & Applying 10mm.th.cement plaster in single coat on brick/
concrete walls similar surfaces for plastering & finished even & smooth with a
24 floating coat of cement slurry mixed with admixture of lime or neeru in S.M. 10.00 199.28
required proportion etc. comp. in C.M 1:3 (1 cement : 3sand) (A) For wall
and similar surfaces -- Ground Floor
First Floor S.M. 10.00 228.84
Second Floor S.M. 10.00 258.39
Terrace (third) Floor S.M. 10.00 287.94
(B) For ceilings &soffits of stairs
Ground Floor S.M. 15.00 225.34
First Floor S.M. 15.00 254.89
Second Floor S.M. 15.00 284.45
Terrace (third) Floor S.M. 15.00 314.00
Providing & Applying 15mm.th.cement plaster in single coat on brick/
concrete walls similar surfaces for plastering & finished even & smooth with a
25 floating coat of cement slurry mixed with admixture of lime or neeru in S.M. 25.00 249.39
required proportion etc. comp. in C.M 1:3 (1 cement : 3sand) (A) For wall
and similar surfaces -- Ground Floor
20mm thick sand faced cement plaster on walls for height more than
metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-
cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1- sand) etc.
Providing 20 mm thick double coat mala cement plaster on brick / concrete work
for plastering comprising of base coat 12 mm thick cement plaster in cement
27 mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of S.M. 25.00 286.10
cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including
scaffolding curing etc. complete.
Providing & Applying 20mm. Th. Heavy Roller plaster on walls or similar
surfaces at all floor levels consisting of 12 mm av. Th. Backing coat of C.M. 1:3 (1
cement:3 sand) & 8 mm. th. Finishing coat of C.M. 1:1 (1 cement: 1 sand)
apply thick cement slurry and apply roller horizontal as well as vartical ( two times
) up to good quality and size of grain in elevation as per directed by engineer
Providing throating or plaster drip and moulding it to R.C.C. chajja etc.
comp.. For all floor
Providing 20 mm deep finished groove in plaster in line and level etc.
Comp. For all Floor (M.R.)
Providing and laying precast terrazo tile 20mm thick white,black, white and
black (or of the colour specified in specification of tender item) marble
chips of sizes upto 6mm laid in floors, treads of steps and landings on a bed of
25mm average thickness of Lime mortar 1:1.5(1-Lime putty : 1.5 coarse sand)
or C.M. 1:6 (1:cement :6 - coarse sand) jointed with neat cement slurry mixed with
pigment to match the shade of tiles including
rubbing and polishing complete with precast tiles of.(A) Light shades using
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick
base of cement mortar 1:6 (1-cement : 6-coarse sand) or
32 L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey S.M. 20.00 1,019.39
cement slurry mixed with pigment to match the shade of slab including rubbing
and polishing etc. complete. (A) 25mm thick
Providing and laying polished kota stone slab 25mm thick in risers of
steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-
33 Cement : 3 coarse sand) and jointed with gray cement slury mixed with S.M. 10.00 1,130.79
pigment to match the shade of slab including rubbing and polishing etc.
Providing & Laying white glazed tiles 6mm. th. of Orient, Kajaria,
Jhonson,Nitco,Somani ,Bell make at all floor levels, in flooring, treads of
steps & landings laid on a bed of 12 mm. Av. Th.C.M.1:3(1cement :3 sand) finished
with flush pointing in white cement etc.com. For all floors
Providing & Laying white glazed tiles 6mm. th. Of Orient, Kajaria,
Jhonson,Nitco,Somani,Bell make at all floor levels in skirting risers of steps & dado
on 10 mm. th. C.M.1:3(1cement :3 sand) including necessary cement paste for
fixing and joined with white cement slurry etc. complete. For all floors
Providing and laying Ceramic tiles 6mm thick in flooring treads of steps and landing
36 laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) S.M. 5.00 960.42
finishing with flush pointing in white cement.
Providing and laying Ceramic tiles 6mm thick in skrting risers of steps and
37 dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and S.M. 5.00 1,037.25
jointed with white cement slurry
Providing & laying marble stone slab flooring over 20 mm.av. base of
38 C.M.1:6 ( 1 cement :6 coarse sand ) & jointed with grey cement slurry incl. S.M. 5.00 2,246.54
rubbing & polishing comp.(A) Marble slab 25 mm. Thick.
Providing & laying granite slab 18mm thick in flooring, treads of steps and
landing laid on bed of 20mm thick cement mortar 1:6 (1 Cement : 6 coarse
39 sand) or lime mortar 1:1.5 laid and finished with flush pointing in white or colour S.M. 5.00 2,410.00
cement including rubbing and polishing complete. ( Basic Rate:-
Providing & laying granite slab 18mm thick in skirting, risers of steps, dedo
and pillars laid on 10mm thick cement mortar 1:4 (1 Cement : 4 Coarse
sand) and finished with flush pointing in white or colour cement including
rubbing & polishing comp.. (Basic Rate:- Rs.1347.46/S.M.)
Providing & laying granite slab 18mm thick in Window-Door seal Frame Etc
laid on 10mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) with nessary
adhesive material and finished with flush pointing in white or colour cement,
including rubbing & polishing comp.. (Basic Rate:- Rs.1000.0/S.M.)
42 Labour Charges For Edge Finished For Granite R.M. 200.00 43.43
Providing & laying Vitrified tiles of 8mm thick of Orient, Kajaria, Jhonson,
Nitco, Somani, Bell, Asian or Euro make in flooring,treads of steps & Landing
laid on bed of 20 mm (Average) base of cement mortar 1:6 (1 Cement :
Coarse sand) on new surface or fixing on existing flooring by adhesive
material including dismentaling of existing flooring and jointed with colour
cement slurry including finished with flush pointing & cleaning the surface etc.
comp.Size 24" x 24"
For Antiskid tiles
Providing and laying Vitrified tiles 8 to 10 mm thick, 24" x 24" in flooring treads of
44 steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1 cement : 3 Sqm. 5.00 1,092.37
coarse sand) finishing with flush pointing in white cement.
Providing and laying Vitrified tiles 8 to 10 mm thick, 24" x 24" in skrting risers of
45 steps and dedo on 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and Sqm. 5.00 1,135.80
jointed with white cement slurry.
Providing and laying Vitrified tiles 8 to 10 mm thick, 36" x 36" in flooring treads of
46 steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1 cement : 3 Sqm. 5.00 1,531.82
coarse sand) finishing with flush pointing in white cement.
Providing and laying Vitrified tiles 8 to 10 mm thick, 36" x 36" in skrting risers of
47 steps and dedo on 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and Sqm. 5.00 1,592.40
jointed with white cement slurry.
Providing and laying chequered precast concrete tiles 22mm thick with
aggregate of sizes upto 6mm in floors treads of steps and landing on 20mm thick
48 bed of C.M. 1:6 (1 cement : 6 sand) or L.M. 1:1.5 (1 Lime putty : 1.5 sand) S.M. 25.00 545.76
jointed with neat cement slurry with pigments to match the shade of the
Providing and laying rough chiseled dressed stone flooring over 20mm thick
base of cement mortar 1:5 (1 cement : 5 coarse sand) or L.M. 1:1.5
including pointing with cement mortar 1:2 (1 cement : 2 stone dust) etc.
Providing and laying cement concrete flooring 1:2:4 (1 cement : 2 course sand :
50 4 graded stone aggregate 20mm nominal size) laid in one layer finished with a
floating coat of neat cement
(A) 40mm thick S.M. 50.00 319.03
(B) 50mm thick S.M. 50.00 374.14
Providing & fixing 35mm.th. Flush Door Solid Double Core type Both Face water
proof Ply Vennered & 1.5 mm th.laminate shall be pasted on both side with
adhesives as specified by the manufacturers. The laminate shall be as per approved
shade & texture, of make incl. Sal wood frames of finished size 12cm x
7cm.incl. S.S. Hinges with nessary screws & Anodized
aluminum fixtures & fastenings For all Floor
52 Same as Above But Without Frame S.M. 5.00 2,520.00
Providing & fixing 35mm.th. Indian teak wood shutters for doors, windows &
clearstory windows incl. Indian teak wood frames of finished size 12cm x
7cm.incl. anodized aluminum fixtures & fastenings incl. Primer coat of
approved quality & two coats of oil painting etc. For all Floor (A) Fully Panelled
(B) Partly Panelled and Partely Galzed S.M. 5.00 5,185.03
(C) Fully Galzed S.M. 5.00 4,836.39
Providing and fixing 35mm thick shutters for Doors, windows and clearstory
54 windows including anodised alluminium butt hinges with necessary screws. S.M. 5.00 4,101.06
(A) Indian teak wood. (i) Fully Panelled.
Providing and fixing FRP FRAME size 125 x 65 mm and 35 mm thick FRP shutter
with wood grain raised panneled design finish shutter having extra reinforcement
on sides & edges in Gel coat finish. The core of the shutter & frame is to be filed up
with injected polyurethene foam done in situ along with embedded wooden pieces
for stiffening & also taking hinges & fixtures. The whole FRP frame & shutter is to
be water proof weather proof,termite proof &resistance to mild acid/alkali. Rates
are to be inclusive of S.S.hinges with fastener sleeve & alluminium fixtures &
Providing and fixing FRP of 35mm thick Fiber Glass shutter with 1.5 to 2.0 mm
thick fire retardent grade FRP skin in depressed panel design having extra
reinforcement on sides & edges & in Gel coat finish. The core of the shutter is to be
filled up with injected retardent grade polyurethane
foam done in situ alongwith embedded wooden pieces for stiffening & also taking
hinges & fintures. The whole FRP frame & shutter is to be water proof
,weather proof, termite proof & resistance to mild acid/alkali. Rates are to be
inclusive of S.S hinges with necessary screws & alluminium fixtures & fastenings.
Providing & fixing M.S.Grills of required pattern to wooden frames of windows etc.
At all floor levels with M.S. flats at required spacing & frame around square
or round bars with round headed bolts & round headed bolts and nuts or by
screws incl. Priming coat of Red lead paint etc. comp. (A) Plain grill For all Floors
Providing & fixing in position collapsible steel shutters with vertical channels
20 x10 x 2 mm. Braced with flat iron diagonals 20 x5mm size with top &
58 bottom rails of T-iron 40x40x6mm. with 38mm dia. steel pulleys comp. with S.M. 5.00 6,158.35
bolts, locking arrangements, stoppers, handles incl. applying a priming coat of
Redlead paint etc. comp.
Providing and fixing M.S. Fan clamps type 1 to 16 mm dia M.S. bar bent to shpe
59 with hooked ends to RCC slabs curing, layig including painting the exposed Each 130.00 135.47
portion of loops, all as per standard design complete.
Providing & laying ordinary C.C.1:1.5:3 mix for R.C.C. work incl. boxing,
centering, vibrating, curing & mixed with approved water proofing cement
compound or "CEMWET"or"PIDICRETE LW"integral water proofing admixture as
water proofing agent to be mixed with 50 kg. cement bag shall be as
recommended by the manufacture of the water proofing material, concrete
work for top, bottom slab & side pardi for Under ground Tank & Item incl.
60 Necessary excavation & refilling the available earth, 15 cm th' C.C 1:4:8 for
bedding concrete, Half B.M. in C.M. 1:4 outside wall, inside R.C.C. pardi as per
design, 10mm.th. water proofing cement plaster in C.M. 1:3 with smooth
finishing,watering etc.Comp.to all inner face & bottom of tank curing etc.
comp. incl. Locking arrangement, outlet, inlet, overflow & wash out pipe
arrangement as necessary & C.I. Cover 0.60 x .045 weight not less then 35kg. etc.
com. as per structural drawing excluding Steel & as directed by Engineer- in-charge
Underground tank Lit. 1000.00 6.87
Providing and filling in depressions of Bath and W.C. At all floor levels, after
61 completing plumbing work of pans, pipes,traps etc.with cinder or fly ash as C.M. 5.00 500.00
directed by Engineer in charge etc. comp..
NOTE :- (1) The whole work is to be executed through specialized agency
with a guarantee of 10 (Ten) years given on a prescribed proforma duly
stamped (2) The rate shall include for work at all floors & conducting water
proof test as directed. (M.R.)
(A) Providing and laying water proofing treatment to vertical and horizontal
surfaces of depressed portions of W.C.,kitchen and the like consisting of :
(a) I course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing
compound conforming to IS : 2645 in recommended proportions.
(b) II course of a layer of plaster in C.M. 1:3 with water proofing compound
confirming to IS:2645 about 25 mm. th' in the floor of the depression & about
18mm th' On the side walls of the depression up to the floor level, water proofing S.M. 10.00 296.00
plaster about 18 mm. th' be continued on the walls above the floor level for a
height of 600 mm. with surface suitable to receive further treatment
(c) Finishing top with stone aggregate 10mm to 12mm nominal size spreading
@0.008 C.M./S.M., thoroughly embedad in plaster layer.
as per specifications & instructions of Engineer in charge (Cement consumption
0.316 Bags / S.M.)
(B) Providing and laying integral cement based water proofing treatment including
preparation of surface as required for treatment of roofs, balconies, terraces etc.
consisting of following operations.
(a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of
cement admixed with proprietary water proofing compound comforming to
IS:2645 over the R.C.C. slab including cleaning the surface before tratment.
(b) Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size
with 50% of cement mortar 1:5 (1 Cement : 5 Coarse sand) admixed with S.M. 5.00 511.00
proprietary water proofing compound conforming to IS:2645 ,brick bats is finally
covered by jointless cement plaster 20mm th. in C.M. 1:4 added with special water
proofing compound confirming to IS:2645 & top smooth finished with trowel with
false chequered marking of 300 mm.size.The treatment is carried along the vertical
surface of the parapet & other adjoining wall up to height of about 300 mm in a
shape of quarter round vata Incl. curing etc. Comp. With average thickness of
mm and minimum thickness at khurra as 65 mm.
(c) The whole terrace so finished shall be flooded with water for a minimum period
of two weeks for curing and for final test. All above operations to be down in order
and as directed and specified by the engineer-in-charge. With average thickness of
120 mm and minimum thickness at khurra as 65 mm. (Cement consumption
Proiding & laying water proofing treatment to vertical and horizontal surfaces like
consisting of (a) I course of applying cement slurry 4.4 kg per sq.mt. mixed with
water proofing compound confirming to IS:2645 in rcommended proportions. (b) II
corse of 20mm cement plaster 1:3 mixed with water proofing compound in
recommended proportion (c) III course of applying blown or / resideal bitumen
applied hot at 1.7 kg per sqm of area. (d) IV course of 400mm micron th. PVC
sheet. (Overlaps at joints of PVC sheet should be 200mm wide and pasted to each
other with bitumen about 1.7 kg./ sqm.)
64 Providing & fixing G.I. Rain water spout of 50 mm.dia & 30 cm length etc. No. 5.00 101.91
Providing & fixing at all floor levels,both face polished machine cut edge green
65 kota stone slab (30mm) for urinal partition joined with grey cement slurry (1:1) S.M. 5.00 900.00
incl. Rubbing & polishing etc. complete. (M.R.)
Providing & fixing at all floor levels,both face polished machine cut edge
66 Marble slab for urinal partition joined with grey/White cement slurry (1:1) S.M. 5.00 1,050.00
incl. Rubbing & polishing etc. complete. (M.R.)( Basic Cost- Rs. 450/S.M.)
WATER SUPPLY AND SANITARY ITEMS
Prov.& Fixing water closet squatting pan (Indian type W.C.pan) at all floor
levels, size 580mm incl. 100 mm size "P'or "S" trap for water closet squatting pan
67 joining the trap with the pan & soil pipe in C.M. 1:1 (1cement :1 fine sand) No. 5.00 1,471.41
etc. Comp.(A) Vitreous china long pattern of approved colour For all
Providing and fixing Wash Down Water closet European type W.C. pan with
integral P or S trap including jointing the trap with soil pipe in cement mortar 1:1
(1 cement : 1 find sand) (seat and cover to be measured and paid for
separately) (A) Viterous china pattern - I (i) in approved colour
Providing and fixing plastic seat and cover for wash down water closet with
C.P. brass hinges and rubber buffers (B) Plastic seat and cover.
Providing & fixing wash basin with single hole for pillar tap at all floor levels, with
C.I. or M.S. Brackets painted white incl. cutting holes & making good the same incl.
fittings such as pillar tap, capstan head screw down high pressure with screws,
shanks & back nuts, C.P. Brass waste trap, screw down stop tap 15 mm. dia. etc.
complete. (A) Vitreous china flat back wash basin 550 mm.x 400 mm. size in
approved colour For all Floor
Providing & fixing Urinal or approved quality including conecting the Urinal
71 with waste pipe, tap etc. complete. (A) White earthenware flat back or corner type Each 5.00 1,074.86
size 430 mm x 260mm x 350mm
Providing & fixing 600 mm.x 450 mm. mirror of superior glass at all floor
72 levels, mounted on 6 mm. th. A.C. sheet or plywood sheet & fixed to wooden plugs No. 5.00 859.41
with C.P.brass screws and washers etc. For all Floor
Prov. & Fixing S.W. Gully trap with C.I.grating brick masonary (C.M
1:5)chamber & water tight C.I. cover with frame of 300mmx300mm size
(inside) with weight includ. plastering smooth inside & outside 15mm. th' in
C.M.1:3 etc. comp. (i) Square mouth traps---(A) 100mm x 100mm Size -P type
(B) 150mm x 100mm Size- P Type No. 5.00 1,246.92
Prov. & Fixing S.W. Gully trap with C.I.grating brick masonary (C.M
1:5)chamber & water tight Pre cast R.C.C. cover of 300mmx300mm size
(inside) includ. plastering smooth inside & outside 15mm. th' in C.M.1:3 etc.
comp. (i) Square mouth traps---(A) 300mm x 300mm Size -P type
(B) 150mm x 100mm Size- P Type No. 5.00 1,052.77
Prov. & Fix. 10 cm.x15 cm.(4" x 6") S.W. trap with Inside dimension ,455 x 610 mm
& 450 mm deep sewer trap chamber with 23 cm th' B.B. masonary walls in C.M
1:5 with cement plaster 15 mm th' in C.M. 1:3 inside & outside to exposed faces,
R.C.C. top slab with 1:2:4 mix ( 1 cement: 2 Sand : 4 Grade stone aggregate 20mm
size) ,Foundation concrete 1:5:10 & fixing C.I. cover with frame to be not less than
38 kg. On top etc. comp. for single pipe.
.(A).Same as above but Precast RCC heavy duty Cover instead of C.I. Cover No. 5.00 2,915.61
Extra for every additional depth of 0.1 mt beyoung 0.45 mt Each 5.00 233.85
Providing & construction simple chamber of 23 cm. th' B.B. Masonary in C.M 1:5
with cement plaster 15 mm th' in C.M. 1:3 inside & outside to exposed faces,
R.C.C. top slab with 1:2:4 mix ( 1 cement: 2 Sand : 4 Grade stone aggregate
20mm size) ,Foundation concrete 1:5:10 & fixing C.I. cover with frame to be
not less than 38 kg. On top etc. comp. Inside dimension,455 x
610 mm &450 mm deep for single pipe
(A) Same as above but Precast RCC heavy duty Cover instead of C.I. Cover No. 5.00 2,681.76
Extra for every additional depth of 0.1 mt beyoung 0.45 mt Each 5.00 242.39
Providing, Lowering & laying joining R.C.C. NP2 CLASS Pipe In C.M. 1:1 of
77 following nominal internal diameters incl. Testing of pipes and joints etc.
Providing & laying in trenches galvanised mild steel tubes(medium grade) TATA /
78 ZENITH / ASIAN / JINDAL MAKE of the following nominal bore & tube fittings etc. R.M. 5.00 282.98
comp..- 25mm.dia.
Providing & Fixing to wall, ceiling floor at all floor levels, galvanised mild steel
tubes(medium grade) TATA / ZENITH / ASIAN / JINDAL MAKE of the following
79 nominal bore, tube, fittings & clamps incl. making good the wall ceiling and floor R.M. 50.00 252.49
(A) 15 mm. dia.
Providing & Fixing C.P. Brass screw down bib tap at all floor levels, polished bright
etc. comp.-(A) 15mm dia. For all Floors
Providing & Fixing gun metal check or non return full way wheel valve at
all floors levels, etc. complete. (A) 15 mm. dia.
Providing & Fixing chromium plated brass half turn flush cock at all floor
levels, of approved quality incl. fixing in pipe line etc. Comp.-- 25 mm dia.
Providing & Fixing abonite ball cock of approved qualities directed etc.
comp. (A) 25 mm. dia.
Providing and fixing C.I. Machinehole cover 0.60 x 0.45 mt. Size having
weight not less than 35 Kg. etc. complete.
Providing & Fixing U-PVC pipe (SWR) confirming to IS no. 13592 (Type "B") of
Prince/Supreme/Jain/Astral/Tulsi/Finolex make for soil and waste discharge
84 system at all floor levels incl. All fixtures like bends, tees, shoe etc. jointed with R.M. 50.00 412.00
resin of approved brand & manufacture etc. comp. (M.R.) (a)
Providing & fixing U-PVC pipes Confirming to IS no. 13592 (Type "A") of
Prince/Supreme/Jain/Astral/ Tulsi/Finolex make for rain water at all floor
levels incl. fixtures like bends, tees, shoe etc joined with resin of approved
brand & manufacture etc. comp. (M.R.) (A) 75 mm. Dia.
Providing, Laying and jointing on true line and level UPVC pipe (SCH-40) line of
Prince/Supreme/Jain/Astral/ Tulsi/Finolex make including fittings make or
equivalent as approved by angineer-in-charge. Pipe shall be fixed on the wall the
help of clamp at every two meter C/C or shall be concealed as directed
including necessary fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all materials.
Providing & Fixing P.V.C. pipes (SCH-80) of Prince/ Supreme/ Jain/ Astral/
Tulsi/Finolex make for water supply line at all floor levels incl. fixtures like
bends, tees, shoe etc joined with resin of approved brand & manufacture etc.
87 comp. Pipe shall be fixed on the wall the help of clamp at every two meter C/C or
shall be concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive solvent, including
cost of all materials.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 110x110 mm
diameter with jali of the following nominal diameter of self cleaning design with
C.I. scread down or hinged grating including the cost of cutting and making good
Providing & Fixing in position PVC Cowl vent to pipes of
Prince/Supreme/Jain/Astral/Tulsi/Finolex make etc.Comp. (A) 75 mm. dia.
Providing & fixing M.S. Holder Bat clamps at all floor levels of approved
90 design to C.I. Or S.C.I pipes including the cost of cutting holes & making No. 20.00 30.00
good the wall etc. Complete - 100 mm. dia. (M.R.)
Providing & fixing G.I./Aluminum Patti clamps at all floor levels of approved
91 design to C.I. Or S.C.I pipes including the cost of cutting holes & making No. 20.00 20.00
good the wall etc. Complete - 100 mm. dia. (M.R.)
Providing erecting and fixing double coated Sintex/Super/Reno PVC (ISI) mark
92 water tank of required capacity each with all necessary fittings & connection Lit. 10000.00 3.95
etc. complete on terrace.
Providing & Fixing Kathi around the vertical PVC drainage pipes for
93 concealing with cement plaster 20 mm avg thickness(CM 1:3 [1 cement :3 coarse
sand]) finishing as per instruction given by Eng. incharge. for
(A) 75 mm PVC PIPE R.M. 50.00 173.00
(B) 100 mm /110 mm PVC PIPE R.M. 50.00 180.00
ITEMS FOR COMPOUND WALL & OTHER MISC. ITEMS :-
Boring holes 3.5 mt.deep in ordinary soil ( for cast in situ piles) & disposal of
94 the surplus excavated soil as directed within a lead of 50 M. For following
diameter of piles.
Providing & laying cement concrete 1:2:4 (1 cement:2 sand:4 graded stone agg.
mm nominal size)& curing comp. Includ.cost of form work but exclu. Cost of
reinforcement for reinforced concrete work in : (A) Foundation, footing, Base
of columns and Mass concrete.
Providing & laying ordinary cement con.1:2:4 (1cement:2sand:
graded stone agg. 20 mm nominal size) finishing smooth curing etc. comp.
Incld. Cost of form work but excl. Cost of reinforcement for R.C.C. Work in :
Up to G.L./P.L. (A) COLUMNS:
(1)Having c/s area up to 0.08s.mt C.M. 1.00 12,335.51
(2) Having c/s area more than 0.08 sq. mt. & upto 0.12 sq.mt C.M. 0.00 10,658.16
(3) Having cross sectional area more than 0.12 sq. mt. C.M. 0.00 8,692.87
(1)Having c/s area up to 0.08s.mt C.M. 1.00 8,593.80
(2) Having c/s area more than 0.08 sq. mt. & upto 0.12 sq.mt C.M. 0.00 7,665.60
(3) Having cross sectional area more than 0.12 sq. mt. C.M. 0.00 6,578.07
Providing & laying C.C 1:3:6 (1cement :3 coarse sand :6 crushed stone agg. 20 m.m
97 Nominal size)& curing comp. incl. cost of from work in: wall caps/ C.M. 1.00 4,085.83
Steel work welded in built up sections, framed work including cutting,
hoisting, fixing in position and applying a priming coat of red lead paint
(A) in beams & joists channels angles, tees, flats with connection plates or
angle cleats as in main & cross beams,hip & trussed purlins connected to Qtl. 1.00 9,108.48
common raffers & the like.
(B)For work like chain link fencing, above compound wall etc. Qtl. 1.00 9,108.48
(C)in trusses & trussed purlins upto 25m.Span &15m.Overall height Qtl. 1.00 10,197.11
Providing and fixing G.I. chain link of 50mm x 50mm size x 10 guage thick with
nuts, bolts, washer or G.I. pins, excluding M.S. angles etc.complete as per relevent
IS specification & directed by engineer in charge. (TATA or Jindal
Providing and fixing hot dip Concertina coil of 610 mm dia. made out of
2.59mm (12 SWG) hot dip galvenized (G.I. coating not less than
gm/sq.m) th. wire having 80 nos. of spikes and 200 nos. of clip made out of
stainless steel (AISI 304 1.5 mm th. dia., G.I. strips 0.5 mm th. (C.I. coating not less
than 120 gm/sq.m.) weight of one coil should not be less than 15 kg. etc. complit,
at the top of compound wall fixed with S.S. clips and binding wires wherever
necessary etc. complit. (Note :- Stretching lehgth of one coil should not be more
Providing and fixing and fitting TATA or Jindal make G.I. barbed wire fencing with
necessary barbed wire (12 x 14 guage, weight not less than 0.14 kg. / mt.) pins,
hooks, excluding M.S. angles etc. complete as per relevent IS specification.&
directed by engineer in charge
Providing & fixing colouron galvaniced steel, zinc / aluminium allus coated sheet
0.5 mm. thick roofing fixed with gslvanised grom J or L hook bolts and bolt 8mm
dia with bituman and impet washer filled with white lead etc. Excluding the
cost of purlins rafter and trusses. (Tata / Jindal or equivalent)
Providing corrugated G.I. Sheets of class-3 roofing fixed with glavanished iron J or L
Hooks, Bolts and nuts 8m diameter with bitumen and G.I. limpet washer or G.I.
102 limpet washer. filled with white lead complete excluding the cost of purlins, S.M. 10.00 734.19
Rafters and Trusses. (1) 0.80 mm thick sheet. (Tata / Jindal or
Providing corrugated G.I. Sheets of class-3 roofing fixed with glavanished iron J or L
Hooks, Bolts and nuts 8m diameter with bitumen and G.I. limpet washer or G.I.
limpet washer. filled with white lead complete excluding the cost of purlins,
Rafters and Trusses. (1) 0.63 mm thick sheet. (Tata / Jindal or equivalent)
Providing & fixing 150mm wide 450mm over all semicircular plain G.I. sheet
class-3 gutter with iron brackets 40mm x 3mm size bolts, nuts, washers etc.
including marking necessary connection with rain water pipes.
(i) 0.8 mm thick
Providing ridges or hips 600mm over all in plain G.I. sheet fixed with G.I. "J" of
105 "L" hooks bolts and nuts 8mm dia G.I. limpet and bitumen washer R.M. 25.00 664.70
complete (1) 0.80 mm thick
Providing & fixing 150mm wide 450mm over all semicircular plain G.I. sheet
class-3 gutter with iron brackets 40mm x 3mm size bolts, nuts, washers etc.
including marking necessary connection with rain water pipes.
(i) 0.63mm thick
Providing ridges or hips 600mm over all in plain G.I. sheet fixed with G.I.
107 "J" of "L" hooks bolts and nuts 8mm dia G.I. limpet and bitumen washer R.M. 25.00 464.00
complete (1) 0.63mm thick sheet
Providing & Fixing UV stabilise FRP Sheet roofing with overlapping the main
cladding on both edges. All fixing holes must be predrilled oversize as specified for
the sheet length and fastener being used. Fasteners must be fitted with approved
washers. Fixings should be tightened to ensure a weatherproof seal but they must
not be over tightened Side-lap fasteners must also be installed at specified centers
108 with the FRP sheet having clearance holes provided as per the main fasteners
Weatherproofing shall be provided at all flashing points under the normal flashing
by the fitting of a foam closure strip to match the profile being used. Closure strips
will be sealed to the sheet with an appropriate non setting silicone sealant.
Excluding the cost
of purlins rafter and trusses.
(a) 1.5 mm thick SM 5.00 992.00
(b) 2 mm thick SM 5.00 1,100.00
Providing & Fixing Polycarbonate sheet roofing with surface of the sheet is
coated with an anti-UV Co-extrusion layer having good weather resistance, it can
maintain its optical properties and mechanical performance for a long time. Fasting
is usually done by screws. , The fastening screws should be inserted about 500 mm
109 apart and 300mm apart Along the supporting internal purlin and edge pulin.All
fixing holes with diameter at least 2 mm larger than screw must be predrilled into
each screw location. The screws should be 6mm diameter with length according to
sheet thickness and corrosion resistant, with at least heavy duty hot dripped
galvanized or stainless steel. Excluding the cost of purlins rafter and trusses.
(a) 1.5 mm thick Solid Sheet SM 5.00 1,261.00
(b) 2 mm thick Solid Sheet SM 5.00 1,510.00
Providing & Fixing 80 mm dia M.S. pipe as vertical post are beded in 1:1.5:3
110 concrete also horizontaly in line and connecting to purline angle etc by welding R.M. 5.00 750.00
rereting etc. (a) Medium duty "B" Class
Providing & Fixing 50 mm dia M.S. pipe as vertical post are beded in 1:1.5:3
111 concrete also horizontaly in line and connecting to purline angle etc by welding R.M. 5.00 485.00
rereting etc. (a) Medium duty "B" Class
Providing & fixing black board on walls of 1.8mt.x1.2mt size made up to
mmth.B.W.P .Plywood (Brand Saras,Kitply,Uniply, Anchor, Green,Wood Stock
or century) fixed with teak wood beading of 65 mmx 50mm size, rubbing & sanding
comp., incl. applying two coats of black board paint over a priming coat on
plywood & French polishing the frame all round etc. Comp. as per instruction
of Engineer in charge (M.R.)
Providing & fixing Green board on walls of 1.8mt.x1.2mt size made up to 18 mm
th.ply (using IS 710 Marin ply) with 1 mm thick outside green board &
113 0.8mm backside white laminate & with good Quality of adhesive with No. 2.00 5,195.00
appropriate fittings of Alluminium fittings or teak wood bedding 65 mmx 50mm
size, rubbing & sanding comp., as per instruction of Engineer in charge (M.R.)
Providing & fixing White board on walls of 1.8mt.x1.2mt size of 12mm thick with
114 appropriate fittings and Alluminium fittings comp., as per instruction of No. 5.00 4,230.00
Engineer in charge (M.R.)
Providing & Fixing Reading table size 8' x 4' and height 2'-6" with table top 18mm
thick (Brand Saras,Kitply,Uniply, Anchor, Green,Wood Stock or century)
commercial plywood with 1.0mm thick lamination sheet fitting with teakwood
moulding table top supported on 3" x 3" teakwood leg & 3" x 11/2" teakwood
framing top and bottom with french polish labour work hardware etc. as per site in
charge instruction and as per drawing.
Providing & Fixing Librarian table with 18mm thick commercial plywood (Brand
Saras,Kitply,Uniply, Anchor, Green,Wood Stock or century) )with 1.0mm thick
lamination sheet table top supported on 2" x 2" teakwood leg & make 3 nos.
drawers of 1' 3" width on both side with necessary french polish hardware labour
etc. as per site incharge instruction and as per drawing ( Size 4' x 2'-6" x 2'-6", all
framing other then legs are teak wood of size 2" x 1")
Providing & Fixing simple 12mm thick commercial plywood (Brand
Saras,Kitply,Uniply, Anchor, Green,Wood Stock or century) Rack of size 6' x4' and
117 depth 1'-6" 5 Nos. horizontal partition, supported 2" x 1" framing with necessary NO 1.00 7,690.00
french polish hardware labour etc. as per site incharge instruction and as per
Providing & Fixing fitting commercial 8mm thick plywood (Brand
Saras,Kitply,Uniply, Anchor, Green,Wood Stock or century) magazine stand of Size
118 6' x 4' with 3" x 11/2" vertical supporting and adjustable lag support and horizontal NO 1.00 6,745.00
simple 2" x 1" teakwood patti for magazine support with necessary french polish
hardware labour etc.as per site in charges instruction and as per drawing.
Providing, supplying & placing precast RCC Woodeny benches as per given
specifications. (Seating plank dimensions : Seating Length of the Bench : 1380 mm,
119 Seating width of the Bench : 450 mm, Seating height of the Bench : 450 mm, NO 1.00 3,927.00
Seating plank thickness : 60 mm, Total height of the Bench :
M-30 grade of Concrete using vibration compaction process. Benches
consists of 2 Nos. L-shape base support in wooden texture and 1 Nos. flate back
and 1 Nos. bottom plank leg thickness :90 mm, Leg hight : 830 mm, Leg width :
mm, backside plank width : 350 mm, backside plank length :
mm, backside plank thickness : 60 mm.
Bench top and back planks are treated with special anticorrosive, water proof
coating, prevent sun, rain, light and fungal attack, as to make surfaces glossy and
The back rest should show as details given by SMC in embossed at casting
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,
channels, plates etc., including welding, grinding, buffing, polishing and
making curvature (wherever required) and fitting the same with necessary
stainless steel nuts and bolts complete, i/c fixing the railing with necessary
120 accessories & stainless steel dash fasteners , stainless steel bolts etc., of Kg 10.00 450.00
required size, on the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-incharge, (for payment purpose only
weight of stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.).
Providing & fixing Z - clamps at all floor levels of approved design to C.I. S.C.I. or
121 PVC pipes including the cost of cutting holes & making good the wall etc.
Complete - 100 mm dia as per architect instructions.
(C) 110 mm dia to upto 150 mm dia No. 20.00 90.00
(C) 150 mm to 200 mm dia No. 20.00 98.00
Providing and constructing sandwitch type Polish Kota Stone cooking
platform 0.6 mt. wide & 0.75 mt. height, including one end side Polish Kota stone
(Double Polish) of 1.25 mt. height & front Polish Kota stone patti of 10 cm wide,
122 vertical partitions of half B.M. wall in C.M. 1:4 and 10mm th. plaster in 1:3 with Rmt. 5.00 3,010.00
finishing smooth with cement slurry as required and Stainless Steel sink of 0.45 mt
x 0.45 mt size of approved quality and make with required all fitings & fixitures
etc. comp as per instruction given by site in charge at all floors.
Providing and constructing sandwitch type Granite stone cooking platform
0.6 mt. wide & 0.75 mt. height, including one end side granite stone (Double
Polish) of 1.25 mt. height & front granite stone patti of 10 cm wide, vertical
partitions of half B.M. wall in C.M. 1:4 and 10mm th. plaster in 1:3 with
finishing smooth with cement slurry as required and Stainless Steel sink of
0.45 mt x 0.45 mt size of approved quality and make with required all fitings &
fixitures etc. comp as per instruction given by site in charge at all floors.
(Basic rate of Granite Rs.1,200.00 / S.M.)
Providing and fixing 150 mm wide, approved quality chicken wire mesh (FRP /
PVC)at junction of brick work and RCC work or two dissimilar surfaces, at all
heights fixed by nails, rowal plugs or tag by cement mortar 1:3 before applying the
plaster, including curing, scaffolding all complete as directed.
Providing and filling Epoxy grout of approved or suggested brand by
125 consultant / Engineer in charge in 4mm to 6mm thick tiles joint including Rmt. 40.00 40.00
spacer with cleaning of joint by vacuum or blower etc
Providing and fixing rebar of following diameter using chemical grout of
Swanchore/Hilti/Fischer or equivalent make including cost of all equipments, tools,
material, labour, etc. Standard procedure as mentioned in
manufacturer's specifications shall be strictly followed, which shall be
submitted and got approved from the authority prior to start of work. The rate
shall also include cost of drilling of hole of required diameter and depth as
mentioned in manufacturer's specification, cleaning the hole with required air
blower and other necessary tools and tackles, positioning, providing and
grouting chemical, allied fixtures and fasteners, etc. but excluding the cost of
reinforcing bar etc. complete. Item includes necessary scaffolding, staging,
labour, tools and equipments, etc. complete as directed by the engineer-in-
Carring out plinth treatment to post construction / existing structure by
spraying chemical solution for termite control treatment including labour and
material consistment with ISI specification. Using Chlordene and Chiorpurfiles
127 20 EC. As per 6131_paret-II Consentration Weight one percent is Smt. 80.00 87.03
recommended i.e. one litre 20 EC chemical emulsion with 19 liter give 1%
concrentration inclusive of one litre chemical emulsion appication at the rate of
litre chemical / Sqm of surface is recommended as per IS.
Providing and fixing rolling shutters of approved make made of 80 mm wide
M.S. laths inter locked together through their entire lenght and jointed together at
the ends by end locks mounted on specially designed pipe shaft with bracket
plates, guide channels and arrangements for inside and outside locking with
push-pull operation including the cost of hood cover and spring etc. complete (A)
Shutters having width below 3.5 M.
Providing and fixing rolling shutters of approved make made of 80 mm wide
M.S. laths inter locked together through their entire lenght and jointed together at
the ends by end locks mounted on specially designed pipe shaft with bracket
plates, guide channels and arrangements for inside and outside locking with
push-pull operation including the cost of hood cover and spring etc. complete. (B)
Shutters having width 3.5 M and above
Providing & Fixing 3 mm thick metal sheet with CNC cutting to fix it on
vertical surface.Steel work welded in built up sections, framed work including
cutting, hoisting, fixing in position and applying a priming coat of red lead paint in
beams & joists channels angles, tees, flats with connection plates or angle cleats as
in main & cross beams, hip & trussed purlins connected to common
raffers & the like.
Providing and laying broken china mosaic flooring for terrace using 12mm to
20mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or
131 slope and to be tempered to bring mortar creme out upto surface using Sqm. 5.00 779.70
white cement including rounding off junctions and extending them upto 15 cm
along the wall clearing with water and oxalic acid etc. as directed.
Providing and Fixing Hollow steel Sections Framed Work including Cutting,
132 Hoisting, Welding & Fixing in position Purlin, Main Chord etc. as per Engineer- in- Kg 5.00 126.00
charge.TATA / JINDAL / ASIAN Make
Providing cement vata (10 cm x 10 cm size) quarter round in cement mortar
1:1 including neat cement finishing, watering etc. complete.
Piping for Fire Safety Works
Providing & Laying 'C' Class Heavy G.I. pipe laying. Supply, fabrication,
installation, hydro testing & painting of above ground pipe. with necessary
pipe fitments (Flanges, Bands, Socket etc.) Vertically every 3 mt. &
134 Horizontaly every 2.5 mt. painted with one coat of primer (Zinc Oxide) & two coats
of finshing paints
GI support / Clamps / Hangers etc. Hardware (Gaskets, Nut-Bolts, Paint etc.)
Consumables (Welding Rod etc.) and labour charge. Quality : GI, C-Class (Heavy).
Make - Jindal / Asian
d 80mm Dia Rmt. 0.00 1,145.23
e 50mm Dia Rmt. 0.00 726.95
f 40mm Dia Rmt. 0.00 536.55
g 25mm Dia Rmt. 0.00 356.71
Fire extinguisher - ABC powder type 6 Kg.
Supply, installation and testing of ABC powder fire extinguisher necessary
hardware and consumables.
Stored pressure mechanism.
Charged with MAP-50% (ABC) Dry powder. with wall mounting clamp.
UOM - Price per each No. Make - Kanex / Safex / Secure Zone
Fire extinguisher - CO2 Gas type 4.5 kg.
Supply, installation and testing of CO2 Gas fire extinguisher with necessary
136 hardware and consumables. No. 0.00 4,200.00
Standard - Confirming to IS:15683-2006 with ISI mark.
UOM - Price per each No. Make - Kanex / Safex / Secure Zone
Supplying FIRE bucket round bottom of 9 ltr. capacity made out of 24 gauge
G.I. sheet with extra handle at bottom duly painted white inside and Red out side
with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on
Supplying and erecting floor mounting stand for keeping four nos. of FIRE
buckets comprising 1500mm in lenght, 900mm height frame made out of
138 30mm x 30mm x 4mm angle from with cross supports for legs, welded with 4 No. 5.00 903.00
hooks and duly painted with one coat of red lead and two coats of approved
enamelled silver paint.
Hoarding Printing and Mounting
139 Hoarding Printing and Mounting Sft. 12.00 16.50
140 Flex Banner (Any size 240 gsm) Sft. 12.00 8.50
Flex Banner with MS (Mild Steel) framing (Any size 240 gsm (Pipe size 25 x
142 Cloth Banner (Upto 8 x 4 feet 140 gsm) Sft. 12.00 23.60
Cloth Banner with MS (Mild Steel) framing (Up to 8 x 4 feet 140 gsm) (Pipe
size 25 x 25 x 1.5 mm)
Cloth Banner with Wooden stick at both end for rally display (Any size
145 Cloth banner standee (Any size 140 gsm Pipe size 25 x 25 x 1.5 mm) Sft. 70.00 69.50
146 Wall Vinyl Sticker Sft. 28.00 28.00
147 Eco Solvent Vinyl Sticker (120 gsm) with Lamination (100 gsm) Sft. 38.00 38.00
148 Solvent Vinyl Sticker (120 gsm) with Lamination (100 gsm) Sft. 22.00 22.00
149 5mm PVC sheet Eco Vinyl (Any size) Sft. 55.46 55.46
150 Decorative theme base designing & painting with all waterproof materials Sft. 63.00 63.00
White Washing with lime on wall surface to give an even shade & surface incl.
throughly brooming the surface to remove dirt, dust mortar drops & losse
scales of lime wash &
other foreign matter Two coats.
(B) Ceiling S.M. 100.00 14.21
---do Extra Subsequant coat over above Item
(A) walls S.M. 100.00 6.01
(B) Ceiling S.M. 100.00 6.51
Colour washing with lime on wall over & incl. a primary coat of white washing to
give an even shade & surface incl. throughly brooming the surface to remove all
dirt, dust mortar
drops & loose scales of lime wash & other foreign matter.Two coats.
(B) Ceiling S.M. 100.00 15.37
---do Extra Subsequant coat over above Item
(A) walls S.M. 102.01 8.35
(B) Ceiling S.M. 100.00 10.53
Distempering two coats with oil bound washable distemper of approved
brand & manufacture & of required shade on wall surface to give an even
shade over and & including a priming coat of alkali resistance primer of approved
3 brand after throughly brushing the surface to give an even shade after throughly
brushing the surface free from mortar droppings and other foreign matter and also
including preparing the surface even
(B) Ceiling S.M. 100.00 84.37
---do Extra Subsequant coat over above Item
(B) Ceiling S.M. 100.00 35.25
Apply two coats of putty and two coats of primer of approved brand and
manufacture on new wall surface to give an even shade including thoroughly
brushing the surface free
from mortar dropping and other matter and sand papered smooth.
Wall painting (two coats) with plastic emulsion paint of approved brand
and manufacture on undecorated wall surface to give an even shade
5 including throughly brushing the surface free from mortar droppings and S.M. 100.00 83.36
other foreign matter and sand
papered smooth.
For every subsequent coat Extra over item no.above S.M. 100.00 35.41
Distempering two coats on previously distempering wall (without primer)
with oil bound washable distemper of approved brand & required shade on wall
6 surface to give an even shade after throughly brushing the surfaces clean of all S.M. 100.00 60.63
grease, dirt loose places
of sceles & also including preparing the surface even and smooth.
Applying Priming coat over new steel and other metal surface after over and
including preparing the surface by throughly cleaning oil, grease dirt and other
7 foreign matter and scoured with brushed fine steel wool, scrapers and sand paper S.M. 100.00 36.74
with ready mixed priming
paint brushing red lead.
Painting two coat (excluding priming coat) on new steel and other metal
with synthetic enemal paint, burshing to give an even shade including
cleaning the surface of all dirt, dust and other foreign matters.
Painting one coat (excluding priming coat) on Previously Painted steel and other
9 metal surface with synthetic enemal paint, burshing to give an even shade S.M. 100.00 39.93
including cleaning the surface of all dirt, dust and other foreign matters.
For every subsequent coat Extra over item no.above S.M. 100.00 40.09
Applying Priming coat over new wood & wood surface after & incl.
preparing the surface by throughly cleaning oil grease dirt & other foreign
matter sand papering &
knetting Really mixed paint brushing priming for enamel.
Painting two coats (excluding priming coat) on New wood & wood based surface
11 with enamel paint to give an even shade & surface incl. cleaning of all dirt, dust & S.M. 100.00 92.87
other foreign matter.
Painting two coats (excluding priming coat) on previously painted wood &
based surface with enamel paint to give an even shade & surface incl. cleaning
of all dirt, dust & other foreign matter.
Polishing with french polished on New wood & wood based surface to give an
even surface incl. cleaning the surface of all dirt, dust & sand papered smooth incl.
Polishing with french polished on previously polishing wood & wood based
surface to give an even surface incl. cleaning the surface of all dirt, dust & sand
incl. a cost of wood filler.
Painting two coats of enamel paint over priming coat (including priming
wall after removing entire surface dirt, dust foreign matter & also incl.
preparing the surface even & sand papered smooth etc. comp.(M.R.)
Painting two coats of enamel paint (Excluding priming coat) over previously
wall after removing entire surface with even shade & surface after removing
dirt, dust foreign matter etc. comp.(M.R.)
Providing & applying two coats of weather shield max paint (3 coats may be
required in case of darker colours.)of ICI Dulux or Apex Ultima of Asian Paint
including applying exterior acrylic primer coat as per manufacturers
specification and directions in shade and colour approved by architects, on
exterior surfaces of the building including scaffolding, preparing the surface,
watering, curing etc. complete and as directed by the architects and
Surface Preparation :
surface is thoroughly clean, dry and free from all loose dirt, chalk, grease, fungi,
17 algae and flaking paint. This can be achieved by brushing with a wire/ stiff coir S.M. 1000.00 82.00
brush, followed by water jetting if required. Fill up all minor cracks and
defects with white cement and sand mixture in the ratio 1:3. For application on
previously painted wall, previous coatings of paint must be thoroughly scraped
off and Clean the surface thoroughly using wire brushes.
Apply a liberal coat of exterior acrylic primer and allow it to dry for 4-5 hours.
Application of putty is not recommended.
Minimum 4-6 hours duration is required between each coat of weather shield max
Aluminium works
Providing and fixing window having extruded aluminum Colour anodized section
frame main outer size 127mm x 38.10mm x 1.35mm @wt. 1.384kg/m, horizontal
Four track member size 122.20mm x 31.75mm x 1.10mm@ wt 1.205 kg/m,
vertical member of size 122.20mm x 31.75mm x 1.50mm @1.398 kg/mt with
shutters of horizontal member size 40mm x 18mm x 1.29mm@ 0.456kg/mt
,vertical member of size 40mm x 18mm x 1.29mm @ 0.456 kg/mt with 5 mm thick
transparent bronze colour tinted float glass with powder coated aluminum fittings
and fixtures and transparent silicon sealant glass fixing to frame as per details etc
complete for window.
(A) Same as above but Colour anodized S.M. 5.00 2,140.33
Providing and fixing window having extruded aluminium Powder Coated section
frame main outer size 95 mm x 24 mm x 1.17 mm (of jindal section no:2459 @ Wt.
of 0.738 Kg/mt), horizontal Three track member size 92 mm x 31.75 mm x
mm (of jindal section no;8688, @ Wt. 1.07 Kg/mt), vertical member of size
2 1.50 mm (of jindal section no:8933, @ Wt. 1.06 Kg/mt) with sliding shutters S.M. 5.00 1,591.87
of horizontal member size 40 mm x 18 mm x 1.29 mm (of jindal section no:8947 @
wt. of 0.456 kg/mt), vertical member of size 40 mm x 18 mm x 1.29 mm (of
jindal section no:8949 @ wt. of 0.456 kg/mt) with 5 mm thick transparent bronze
colour tinted float glass with powder coated aluminium fittings & fixtures and
transparent silicon sealant glass fixing to frame as per details etc.
(A) Same as above but Colour anodized S.M. 5.00 1,591.87
Providing and fixing window having extruded aluminium Powder Coated section
frame main outer size 63.50 x 38.10 x1.95 mm (of Jindal section
no.4605, @ Wt. 1.094Kg/mt) horizontal Two track member size 61.85 mm x
31.75 mm x 1.20 mm (of jindal section no:8687, @ Wt. 0.695 Kg/mt.) vertical
member of size 61.85 mm x 31.75 mm x 130 mm (of jindal section no:8758 @ wt.
of 0.659 kg/mt) with sliding shutters of horizontal member size 40 mm x18 mm x
1.29 mm ( of jindal section no:8949, @ Wt. of .456 Kg/mt) vertical member of size
40 mm x 18 mm x 1.29 mm (of jindal section no:8947, @ Wt. of
Kg/mt/section 8948, @ Wt. of 0.457 Kg/mt) with 5 mm thick tranparent bronze
colour tineted float glass with powder coated aluminium fittings and fixtures and
transparent silicon sealant glass fixing to frame as per details etc. complete
(A) Same as above but Colour anodized S.M. 5.00 1,705.67
Providing and fixing standared extruded ofalluminium section of size 63mm x
38.10mm x1.2mm , @ Wt. 0.643 Kg/mt with colour Powder
Coated alluminium frame for ventilation with
mm thick frosted glass as details etc complete for Ventilation
(A) Same as above but Colour anodized S.M. 5.00 1,175.56
Providing and fixing standared extruded of aluminium section of size 61 x
x0.90 mm (of Jindal section no.14080, @ Wt. 0.471 Kg per mt) with Powder
5 Coated alluminium frame with 5 mm thick transparent bronze colour tinted float S.M. 5.00 1,833.29
glass as details
etc. complete for fix window.
(A) Same as above but Colour anodized S.M. 5.00 1,833.29
Providing & fixing partly panel & partly glass Powder Coated Aluminium doors
with aluminium section of Hindalco, Jindal , Narmada,Banco or Equivalent
approved make having Poder Coated outer frame Leg Partition section of
63.50 mm x 38.10 mm having weight 1.158 kg. / R.M. shutter section having size
83.5 mm x 44.45mm ( top & bottom: 1.384 kg./rmt. and middle 1.139 kg./rmt.)
door vertical 47.62mm x 44.45 mm ( vertical:0.881 kg./rmt. & top hing side:0.974
kg./mt.), Glazing Clip (Jindal Section No. 19370 Wt. 0.109 Kg./ Mt.) with 5mm thick
sheet glass in acid frogting and 12 mm thick prelaminated sheet of Greenlam,
Panama or archid make as approved by Engineer-in- charge including fixing brass
pivot, handle, lock etc. complete.
(A) Same as above but Colour anodized S.M. 5.00 3,237.00
Providing & fixing Powder Coated Aluminium partly glazed and partly
panelled partition using medium duty sections of Hindalco,Zindal,
Narmada, Banco or Equivalent approved make having section 63.50 mm x
38.10mm ( Frame-.758 kg/rmt & Middle section- 0.819 Kg./rmt), Galzing Clip
with 5 mm thick clear float glass of approved make including all other
necessary fittings and fixtures. Entire work will have to be made water proof using
necessary rubber sectioned wherever required. Gaps all round the frame to be
filled with approved water proof sealent. Bottom portion of doors both side to be
covered with 12mm thick prelaminated particle board of approved
make and quality and as per design.
(A) Same as above but Colour anodized S.M. 5.00 2,400.00
ITEMS FOR GROUND DEVELOPMENT WORK
Box Cutting the road surface to proper slope and camber for making base
1 includinng removing the excavated stuff and depositing on the road side slope as C.M. 10.00 109.41
directed up to 50 mt. lead.
Preparation of subgrade with Compacting, Levelling and consolidation of subgrade
with miniroller /plate vibrator machine including watering and filling in depressions
which occur during the process as directed by engineer in
Providing & filling with Mix soil in layers of 20 cm. Th'. Incl. watering,
ramming & consolidation etc. complete.
Supplying & filling fine sand(pana) in 75 mm / 100 mm / 150 mm compacted
thickness over the base including necessary compaction, watering etc. complete.
Item includes leveling by using vibratory plates compacted
machine and as directed by engineer in charge.
Providing and laying cement concrete 1:5:10 (1- Cement : 5- Coarse sand : 10-
5 hand broken stone aggregates 40 mm nominal size) and curing complete excluding C.M. 5.00 2,606.92
cost of formwork in (A) Foundation and Plinth
Providing 100mm thick readymade C.C. kerb of strength M-20 (size 300mm x
380mm) purchased from SMC's approved paverblock manufacturer & setting in
line, level and in truly vertical position, including filling joints in C.M. 1:1 (1 part of
cement : 1 part of stone dust) smooth pointing in C.M. 1:1 (1 part of cement :
part of coarse sand) including watering etc. complete and
as directed by engineer in charge.
For rounding at the edge of footpath (For fanning portion) R.M. 10.00 274.00
Providing interlocking type Rubber moulded cement concrete paver block of
approved shape, design & colour having 60mm thickness (M-35) purchased from
SMC's approved paverblock manufacturer only & fixing of fine sand bedding. Item
includes levelling by using vibratory plates compacted machine. Item also includes
all materials, labour, equipments, tools, plants, watering, cleaning etc. complete.
Without colour S.M. 229.50 524.00
Providing & fixing interlocking type Cement Concrete paver block of approved
shape & design having 60 mm thickness (M-40) purchased from SMC's approved
paverblock manufacturer only on fine sand bedding. Item includes leveling by
using vibratory plates compacted machine. Item also includes all materials, Labour,
euipments, tools, plants, watering, cleaning
For Road Junction 80 mm thick ( M-50) S.M. 10 714
Providing & laying Granular sub base (GSB)confirming to Grading-V of Table
400.0 of compacted thick of 150mm with specified graded stone metal and sand
mixed in place and laid with mechanical means spreading with motor grader
and compacting with vibratory roller having minimum 80-100 KN static weight
to acheve desired density of 98% of MDD including all material, labour,
machinery with all leads and lift etc. complete.
Providing & laying cement concrete Pavement using 1:1.5:3 (1 cement:1.5 sand:3
graded stone agg. 20 mm nominal size) & Vaccuum Dewatering technique
including floating surface with a skim powder floater, curing etc.
Providing & laying cement concrete Pavement using 1:2:4 (1 cement:2 sand:4
graded stone agg. 20 mm nominal size) & Vaccuum Dewatering technique
including floating surface with a skim powder floater, curing etc.
Providing and laying 200 micron plastic sheet on prepared sub base For
Cutting of Groove 5 to 7 mm thick in VDS for depth 1/3 of total thickness with
filling of epoxy sealent as directed by engineer in charge
Providing & fixing C.P. brass pillar cock with copper connection, C.P.
brass screws complete
Make- Cera F2013101, HindWare Cat. No.: F650003, Jaquar FLR-
Providing & Fixing 15 mm Dia bib tap with wall Flange at all floor
levels, polished bright etc. comp.
Make- Cera F2013151 BIB COCK, HindWare F280002 BIB COCK,
Jaquar FLR-5047 N BIB COCK
Providing & Fixing 15 mm Dia 2 way bib tap with wall Flange at all
floor levels, polished bright etc. comp.
Make- Cera F2013163, HindWare Cat. No.: F530004, Jaquar FLR-
Providing flush cock consisting lever, cartridge sleeve & flange &
Make- Cera EXPOSED PART F2013751 &Concealed part F4060101 , Jaquar FLR
5083 KN , CONCEALED BODY ALD-081,HINDWARE F730013 & CONCEALED STOP NO. 5.00 2056.47
Providing & fixing 15mm C.P. brass angle valve (Stop Cock) with
5 C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange
complete, including cutting and making good the wall where required.
Make- Cera F1020362, HindWare Cat. No.: F440020 F850094,
jaquar CON 053 KN
Providing and fixing Wash Down Water closet European type W.C. pan with
integral P or S trap with normal closing seat cover L bend ncluding jointing the trap
with soil pipe in cement mortar 1:1 (1 cement
: 1 find sand) (A) Viterous china pattern - I
Make- Cera CONVENTIONAL B1510121 , HindWare sleek
Jaquar- CNS-WHT-751P180SPPZ
Providing & fixing Wash Hung basin with single hole for pillar tap , Size- 550 x
mm at all floor levels, with C.I. or M.S. Brackets painted white incl. cutting holes &
making good the same etc.
complete. For all Floor
Make- Cera Cat. No. S2040121, Jaquar SLS- WHT -6801
Providing & fixing white vitreous china urinal of size 450 x325mm as per IS-2556
(Part-2 ) with C.I. hangers and 15mm dia. C.P. spreader,32mm dia CP bottle trap
8 and pipe to wall with C.P. flange complete including cutting and making good the
walls and floors
wherever required.
Make- CeraCat. No. S4020103, Jaquar URS-WHT-13261H ,HindWare
Providing & fixing of overhead shower 80 mm (3”) dia with 3 flow with Overhead
Shower arm 200 mm with wall flange complete
Make- Cera F7010602AB, Jaquar OHS-1989 ,HindWare Cat. No.:
Providing and fixing Towel Ring fabricated from seamless stainless steel tube 2mm
10 thick in bath room with polished wall flange at end of bars with heavy duty anchor
fasteners & accessories.
Make- Cera F5014115CH, Jaqua ACN-1121N ,HindWare F880007 NO. 5.00 924.24
Providing & fixing S.S.towel rail of 600 mm long approved make including,
11 providing & fixing C.P. brass screws, making holes in walls
Make- Cera F5015103CH,Jaquar 1111BSM ,HindWare F880005T NO. 5.00 1100.42
Providing & Fixing stainless steel recessed type Soap dish of
12 approved make. Including providing & fixing screws, washers, cutting & making
good the walls.
Make- Cera F5007106, Jaquar ACN-1131N ,HindWare F880011 NO. 5.00 839.91
Prov.& Fixing water closet squatting pan (Orissa type W.C.pan) at all floor levels,
size 500mm x 400 mm incl. 100 mm size "P'or "S" trap for water closet squatting
13 pan joining the trap with the pan & soil pipe in
C.M. 1:1 (1cement :1 fine sand) etc. Comp.(A) Vitreous china long
Make- Cera S3010109, Jaquar ,HindWare 20143 NO. 5.00 3277.39
Prov.& Fixing Health Faucet ABS Body with wall Hook and 1 Meter
chrome plated PVC Hose Pipe.
Make- Cera F8030106AB, Jaquar ALD-587 ,HindWare F160109 NO. 5.00 1009.90
Providing & fixing white vitreous china Ladies urinal of size 470 x360X100 mm and
15mm dia. C.P. spreader, and pipe to wall complete including cutting and making
good the walls and floors
wherever required.
Make- Cera 4040101 ,HindWare 60003 NO. 5.00 2316.05
Providing & fixing Paper holder with flap guard of 150 mm long
16 approved make including, fixing C.P. brass screws, making holes in walls & making
Make- Cera f5002110, Jaquar AHS-1551 ,HindWare F890003 NO. 5.00 1751.51
Providing & Fixing pressmatic bib tap with wall Flange at all floor
levels, polished bright etc. comp.
Make- Cera F9020151, Jaquar PRS-043 ,HindWare F310016 NO. 5.00 1842.06
Providing Metropole Flush Valve Dual Flow 40mm
Size (Concealed Body)
Make- Cera F8010202 , Jaquar FLV-1089NSQ ,HindWare F860075 NO. 5.00 3500.99
19 Providing Sink Cock with Regular Swinging Spout
Make- Cera F2008251, Jaquar FLR-5347N ,HindWare F650013 NO. 5.00 1785.90
Rehabilitation Work Items
'Fixing clerestory window chowkhats in existing openings including cutting
masonry for hold fasts, embedding hold fasts in cement concrete blocks with
cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate
1 mm single size), painting two coats of coal tar to sides of chowkhats and making Nos 1.00 399.00
good the damge to walls complete including disposal of rubbish to the dumping
Providing and applying cement mortar (1:3) modified by using polymer and
expanding grout additives at 25mm thickness for repair/strengthening of various
RCC elements at all floor levels, lead, lift, including breaking, chipping, dismentling
existing cover concrete and exposing existing reinforcement, applying wirebrush
2 for making surfaces of steel and concrete free from rust and other loose materials, Sq.mt 1.00 1,208.00
applying rust removing chemical on existing reinforcement, applying anti- corrosive
coating on existing reinforcement, applying polymer bonding agent on existing
concrete surfaces before applying polymer modified mortar in specified thickness
as directed by the Engineer-in-charge.
Providing and applying cement mortar (1:3) modified by using polymer and
expanding grout additives at 50mm thickness for repair/strengthening of various
RCC elements at all floor levels, lead, lift, including breaking, chipping, dismentling
existing cover concrete and exposing existing reinforcement, applying wirebrush
3 for making surfaces of steel and concrete free from rust and other loose materials, Sq.mt 1.00 2,348.00
applying rust removing chemical on existing reinforcement, applying anti- corrosive
coating on existing reinforcement, applying polymer bonding agent on existing
concrete surfaces before applying polymer modified mortar in specified thickness
as directed by the Engineer-in-charge.
Providing Cement Concrete work 50% - M30-(design mix) and 50% micro concrete
plus recron - 3s (12mm long polyester fiber) plus appropriate dose of super
plasticizer with curing, finishing smooth, etc. complete for jacketing of structural
members at all floor levels, lead, lift, including breaking, chipping, dismentling
existing loose cover concrete and exposing respective existing reinforcement as
directed by the engineer-in-charge, applying wirebrush for making surfaces of steel
and concrete free from rust and other loose materials, applying rust removing
4 chemical on existing reinforcement, applying anti-corrosive coating on existing C.M. 1.00 29,664.00
reinforcement, applying polymer treatment and bonding agent on existing
concrete surfaces as directed by the Engineer-in-charge, etc. complete. The make
and quality of rust removing chemical, anti-corrossive coating, polymer / epoxy
bonding agent shall be approved by engineer-in- charge. The procedure for
application shall be strictly in accordance with manufacturer's detail specification,
which shall be submitted before start of work and shall be approved by the
Engineer-in-charge.
Providing Cement Concrete work 75% - M30-(design mix) and 25% micro concrete
plus recron - 3s (12mm long polyester fiber) plus appropriate dose of super
plasticizer with curing, finishing smooth, etc. complete for jacketing of structural
members at all floor levels, lead, lift, including breaking, chipping, dismentling
existing loose cover concrete and exposing respective existing reinforcement as
directed by the engineer-in-charge, applying wirebrush for making surfaces of steel
and concrete free from rust and other loose materials, applying rust removing
5 chemical on existing reinforcement, applying anti-corrosive coating on existing C.M. 1.00 19,053.00
reinforcement, applying polymer treatment and bonding agent on existing
concrete surfaces as directed by the Engineer-in-charge, etc. complete. The make
and quality of rust removing chemical, anti-corrossive coating, polymer / epoxy
bonding agent shall be approved by engineer-in- charge. The procedure for
application shall be strictly in accordance with manufacturer's detail specification,
which shall be submitted before start of work and shall be approved by the
Engineer-in-charge
Providing and appliying thixotropic Making up lost section of concrete / mortor
with thixotropic repair mortor of one- component, normal-setting, shrinkage-
compensating, thixotropic mortar for layers up to 25 mm thick. Supply and
application of one-component, normal-setting, shrinkage- compensating
thixotropic mortar made from cementitious binders, selected aggregates, special
additives and synthetic polyacrylonitrile fibres, for reconstructing deteriorated
concrete structures. Apply the mortar after adequate preparation of the substrate
by removing all deteriorated concrete to form a sufficiently-rough, solid substrate
with no detached portions. Clean the steel reinforcement down to bare metal and
apply a passivating treatment by brush- applying two coats of one-component, anti-
corrosion cementitious mortar. Apply the product by trowel or spray with a
continuous-feed rendering machine on a clean substrate saturated with water in
layers up to 20 mm thick.
To improve expansion in the open air during the first few days of curing, add a
special curing additive when mixing the mortar to reduce both plastic and
hydraulic shrinkage at a dose of 0.25% in weight on the weight of the mortar. The
product must comply with the minimum requirements of EN 1504-3 for structural
mortars and have the following performance characteristics:
Compressive strength (EN 12190) (MPa):> 40 (after 28 days) Flexural strength (EN
196/1) (MPa): 7 (after 28 days) Compressive modulus of elasticity (EN 13412)
(GPa): 25 (after 28 days)
Adhesion to substrate (EN 1542) (MPa):> 2 (after 28 days) Capillary absorption (EN
13057) (kg/m²•h0.5): < 0.20 Thermal compatibility measured as adhesion
according to EN 1542 (MPa): – freeze-thaw cycles with de-icing salts (EN 13687/1):
> 1.5 (after 50 cycles)
Storm cycles (EN 13687/2):> 1.5 (after 30 cycles)
– dry thermal cycles (EN 13687/4):> 1.5 (after 30 cycles) Reaction to fire (EN 13501-
1) (Euroclass):1 Sq.mt 1.00 1,370.00
Consumption (per cm of thickness) (kg/m²): approximately
included and calculated in the price for work carried out according to specification:
(1) hydro-cleaning of adhesion surfaces and saturation of substrate with water
immediately before applying the mortar;
(2) application of the mortar by trowel or spray around steel reinforcement;
(3) levelling off surfaces with a straight edge and final tamping;
(4) careful curing of the mortar by spraying on water for at least 7 days (3times)
after application.
Providing and appliying thixotropic Making up lost section of concrete / mortor
with thixotropic repair mortor of one- component, normal-setting, shrinkage-
compensating, thixotropic mortar for layers up to 50 mm thick. Supply and
application of one-component, normal-setting, shrinkage- compensating
thixotropic mortar made from cementitious binders, selected aggregates, special
additives and synthetic polyacrylonitrile fibres, for reconstructing deteriorated
concrete structures. Apply the mortar after adequate preparation of the substrate
by removing all deteriorated concrete to form a sufficiently-rough, solid substrate
7 with no detached portions. Clean the steel reinforcement down to bare metal and 1
apply a passivating treatment by brush- applying two coats of one-component, anti-
corrosion cementitious mortar. Apply the product by trowel or spray with a
continuous-feed rendering machine on a clean substrate saturated with water in
layers up to 40 mm thick. To improve expansion in the open air during the first few
days of curing, add a special curing additive when mixing the mortar to reduce
both plastic and hydraulic shrinkage at a dose of 0.25% in weight on the weight of
the mortar. The product must comply with the minimum requirements of EN 1504-
3 for structural mortars and have the following performance characteristics:
Compressive strength (EN 12190) (MPa):> 40 (after 28 days) Flexural strength (EN
196/1) (MPa): 7 (after 28 days) Compressive modulus of elasticity (EN 13412)
(GPa): 25 (after 28 days)
Adhesion to substrate (EN 1542) (MPa):> 2 (after 28 days) Capillary absorption (EN
13057) (kg/m²•h0.5): < 0.20 Thermal compatibility measured as adhesion
according to EN 1542 (MPa): – freeze-thaw cycles with de-icing salts (EN 13687/1):
> 1.5 (after 50 cycles)
Storm cycles (EN 13687/2):> 1.5 (after 30 cycles)
– dry thermal cycles (EN 13687/4):> 1.5 (after 30 cycles) Reaction to fire (EN 13501-
1) (Euroclass):1 Sq.mt 1.00 2,460.00
Consumption (per cm of thickness) (kg/m²): approximately
included and calculated in the price for work carried out according to specification:
(1) hydro-cleaning of adhesion surfaces and saturation of substrate with water
immediately before applying the mortar;
(2) application of the mortar by trowel or spray around steel reinforcement;
(3) levelling off surfaces with a straight edge and final tamping;
(4) careful curing of the mortar by spraying on water for at least 7 days (3 times)
after application.
Pointing on brickwork with cement mortar 1:1 (1-cement : 1-
coarse sand) (B) Ruled pointing.
Aluminum section Window opening and refixing with all
necessary fix & fiting etc maid in wisely.
Providing & Applying 20mm.to 35mm Th.(Max. 35mm thickness consider) Heavy
Roller plaster on walls or similar surfaces at all floor levels consisting of 12 mm av.
Backing coat of C.M. 1:3 (1 cement:3 sand : racron 3s ( 0.5 nos per bag )) also
10 plaster master wterproofing chemical 100 ml /bags as per companey manual & Sq.mt 1.00 417.00
approved by E.I.C or consultant & 8 mm. th. Finishing coat of C.M. 1:1 (1 cement:
1 sand) apply thick cement slurry and apply roller horizontal as well as vartical (
two times ) up to good quality and size of grain in elevation as per directed by
engineer incharge.
Providing & fixing G.i mesh 25X25X3mm used for celling repair fixed with celling
11 rebar column as per directed by Sq.mt 1.00 546.00
enginner incharge rate excluding the rebar cost .
RCC Core Cutting is about making precise, circular cuts for creating holes of
required diameters for Rehabilitation in civil works. The core drilling rod is fitted
with diamond pieces at the drilling end. The core cutting machine can be used for
both horizontal and vertical hole making purposes.
Apply hacking on RCC member manual or by mechanical as discoused by engineer
14 incharge. 350 - 400 notches (dents) per sqmt. Process of making the back ground Sq.mt 0.00 20.00
rough before plastering for better bonding of mortar with RCC (Tacha)
15 Polishing flooring after repair work done as direct by E.I.C Sq.mt 1.00 172.00
Providing & Fixing Nylon net (having net weight-0.065 kg/sq.mt) in outside as well
as inside plaster / terrace water proofing at any height (no load or lift will be paid
same) etc as direct by E.I.C
Providing & Applying Surface Water Proofing treatment on existing Water
(1) Cleaning Surface Slab up to Mother slab & free from any Loose Material. Paint,
Dust, Greaze or Remove all existing bituminious Coating Completely. It is
recommended to use intense wise brushing on high speed Water jet for through
(2) The Substrate must be checked for its Soundness using Small hammer. All
Cracks at corner joint, Channels and Parapet Should be Properly treated.
(3) Cracks/construction joints treatment: Opening the cracks/construction joints,if
any, in V/U shape using electrically operated cutting machine. Cleaning the surface
17 thoroughly from dust and loose partical using wire brush and air blower. Filling the Sq.mt 1.00 494.00
cracks if any with polymer modified cement mortar hybrid PU Sealant depending
on the width of crack/joint.
(4) Epoxy primer:The Epoxy primer must be applied on clean and dry surface by
mixing base and hardner in equal proportions with the help of strirrer and adding
equal amount of water and appling on the surface at 80-100 grams per sqmt and
allowed it to dry untill tack free.
(5) Hybrrid polyurea part-A(base) and part-B(hardner) are packed in two separate
containers having the correct predetermined mixing ratio by weight.Stir individual
container separately,Part-A and PArt-B very well, to get homogeneous
material. The whole quantity of Part-B is added into Part-A.
Providing & Applying vata (10 cm x 10 cm size) quarter round in cement mortar
(1:3) modified by using polymer and expanding grout additives including neat
cement finishing,
watering etc. complete.
Carrying out Injection grouting for cracks in RCC structural members by drilling
holes of 15 mm diameter upto minimum depth of 75 mm, fixing aluminium nozzle /
rubber pipe using non-shrink epoxy putty, injecting epoxy grout material at
specified pressure with grouting pump till it the material refuses to impregnate
inside the hole. If required or suggested by the Engineer-in-charge, injection
grouting shall be carried out more than once for a hole to assure proper spreading
of grout material and filling of capillaries / voids within the element. After
satisfactory injection grouting, the nozzle/pipe shall be cut and sealed by non-
shrink epoxy putty.
The surface shall be finished smooth with C:M (1:4) and reinstated to the original
condition as directed by the Engineer-
The rate shall include the cost of providing and supplying all tools, materials,
labour, scaffolding, props, formwork, etc. complete. The make and quality of
epoxy grout, epoxy putty, etc. shall be approved by the Engineer-in-charge.
The procedure for application shall be strictly in accordance with Sq.mt 1.00 450.00
manufacturer's detail specification, which shall be submitted before start of
work and shall be approved by the Engineer-in-charge. (Actual no of holes
and their locations shall be as decided by the Engineer-in-charge)
Carrying out Injection grouting for cracks in RCC structural members by
drilling holes of 15 mm diameter upto minimum depth of 75 mm, fixing aluminium
nozzle / rubber pipe using cementitious compound, injecting polymer modified
slurry (SBR+cement+water) 1:1:1 material at specified pressure with grouting
pump till it the material refuses to impregnate inside the hole. If required or
suggested by the Engineer-in-charge, injection grouting shall be carried out
more than once for a hole to assure proper spreading of grout material and filling
of capillaries / voids within the element. After satisfactory injection grouting,
the nozzle/pipe shall be cut and sealed by non-shrink epoxy putty. The surface
shall be finished smooth with C:M (1:4) and reinstated to the original
directed by the Engineer-in-charge.
The rate shall include the cost of providing and supplying all tools, materials,
labour, scaffolding, props, formwork, etc. complete. The make and quality of
epoxy grout, epoxy putty, etc. shall be approved by the Engineer-in-charge.
The procedure for application shall be strictly in accordance with Sq.mt 1.00 250.00
manufacturer's detail specification, which shall be submitted before start of
work and shall be approved by the Engineer-in-charge. (Actual NOS of holes
and their locations shall be as decided by the Engineer-in-charge)
Providing and applying cement mortar 1:4 enriched with expanding grout additive
in required proportion in cement for repair of cracks in RCC and non-RCC
members after making 25mm x 25mm groove, cleaning the surface and applying
coat of bonding, finishing smooth the repaired surfaces, providing and applying
curing agent on the repaired surfaces, etc. complete at all floor levels as directed
21 by engineer-in-charge. The make and quality of expanding grout additives, bonding Sq.mt 15.00 120.00
agent, curing agent, etc. shall be approved by the engineer-in-charge. The
procedure for application shall be strictly in accordance with manufacturer's detail
specification, which shall be submitted before start of work and shall be approved
the Engineer-in-charge.
EXECUTIVE ENGINEER
SOUTHZONE-B(KANAKPUR)
SURAT MUNICIPAL CORPORATION
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
TECH BID-03.pdf
PRICE BID-03.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].