Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAdmitted-Finance 1241 4TH FLOOR SOLITAIRE CORPORATE PARK BUILDING NUMBER 12 ANDHERI GHATKOPAR LINK ROAD ANDHERI EAST | L1 | Admitted-Finance | |
| 2 | L2₹39.7 L+₹18.8 L (89.7%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹51.7 L+₹30.7 L (146.8%)Admitted-Finance 101 KRISHNA COLONY NEAR AIRPORT FLYOVER THANA SANGANER JAIPUR | JAIPUR | RAJASTHAN | L3 | Admitted-Finance | |
| 4 | L4₹52.0 L+₹31.1 L (148.5%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹53.3 L+₹32.3 L (154.4%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | India Medtronic Pvt. Ltd. L1 | RENIX L2 | R R DISTRIBUTORS L5 | SAHU SURGICAL EMPORIUM PVT .LTD. L3 | hope health care L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Titanium Ligaclips small with Small diamond shape pyramidal heads, similar to needle holder Inserts, ensuring a firm multi-directional atraumatic grip. Interlocking atraumatic teeth designed for non-slip closure on the vessels. Triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. Should be US FDA Approved. | 1 | Nos | - | - | - | 351 ₹351 Lowest | - |
| 2.00 | Titanium Ligaclips medium with Small diamond shape pyramidal heads, similar to needle holder Inserts, ensuring a firm multi-directional atraumatic grip. Interlocking atraumatic teeth designed for non-slip closure on the vessels. Triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. Should be US FDA Approved. | 1 | Nos | - | - | - | 315 ₹315 Lowest | - |
| 3.00 | Titanium Ligaclips large with Small diamond shape pyramidal heads, similar to needle holder Inserts, ensuring a firm multi-directional atraumatic grip. Interlocking atraumatic teeth designed for non-slip closure on the vessels. Triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. Should be US FDA Approved. | 1 | Nos | - | - | - | 315 ₹315 Lowest | - |
| 4.00 | Proximal aortic anastomosis device. It should provide stable blood field. It allows for up to three anastomosis from one insertion. Size – 3.5mm/4.0mm/4.5mm | 1 | Nos | - | - | - | 39,500 ₹39,500 Lowest | - |
| 5.00 | Membrane Oxygenator (Plasma resistant) with integrated arterial filter.
Should have surface area with surface area of 1.4 m2. It should have radial blood flows design to give efficient gas transfer. It should have quick priming inlet and vacuum assisted venous drainage. Oxygenator Should have self-venting facility. Integrated arterial filter should be polyester/polycarbonate/equivalent material. Integrated arterial filter pore size should be less than 40 micron with the surface area of around 60-80cm2. Priming volume of around of less than 285ml visible path top to bottom should have maximum flow for large body surface area patient ranging from 0.5 to 6 L/M. Should have phosphoryl choline (PC) coating like phisio. Should be able to operate at venous reservoir level of minimum 150 ml. Oxygenator reservoir should have polycarbonate/polyester/equivalent screen type venous filter with pore size less than 50 micron. Should be US FDA Approved. Should be supplied with Appropriate stand. | 1 | Nos | - | - | - | 22,500 ₹22,500 Lowest | - |
| 6.00 | UW Solution for organ transplant use. | 1 | Nos | - | - | - | 28,000 ₹28,000 Lowest | - |
| 7.00 | Dacron Graft knitted Bioseal Grafts diameter 6mm to 8mm length 30 cm | 1 | Nos | - | - | 35,000 ₹35,000 | 26,500 ₹26,500 Lowest | - |
| 8.00 | Dacron Grafts knitted Bioseal diameter 6mm to 8mm length 60 cm | 1 | Nos | - | - | - | 28,500 ₹28,500 Lowest | - |
| 9.00 | Dacron Grafts woven Bioseal diameter 20mm to 32mm length 30 cm | 1 | Nos | - | - | 35,000 ₹35,000 | 28,500 ₹28,500 Lowest | - |
| 10.00 | Aortobifemoral bioseal graft dacron sizes - 6x12x45 / 7x14x45 / 8x16x45 | 1 | Nos | - | - | - | 31,200 ₹31,200 Lowest | - |
Tender Value
₹10 Cr
EMD Value
₹20 L
Closing Date
13 May 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintendent, mathuradas mathur hospital ,jodhpu
Superintendent, mathuradas mathur hospital ,jodhpu
01(2025-26) Item No. 01 CARDIOTHORACIC EQUIPMENTS AND IMPLANTS
2025_SNMCJ_459770_1
01(2025-26) Item No. 01 CARDIOTHORACIC EQUIPMENTS AND IMPLANTS
Open Tender
Medical Equipments/Waste
Item Wise
15 days
Mathuradas mathur hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
SUPERINTENDENT, MDMH
₹20 L
Yes
Superintendent, mathuradas mathur hospital ,jodhpu
2 Jul 2025
17 Apr 2025
14 May 2025
17 Apr 2025
13 May 2025
17 Apr 2025
25 Apr 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Titanium Ligaclips small with Small diamond shape pyramidal heads, similar to needle holder Inserts, ensuring a firm multi-directional atraumatic grip. Interlocking atraumatic teeth designed for non-slip closure on the vessels. Triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. Should be US FDA Approved. | 1 | Nos | - | - |
| 2 | Titanium Ligaclips medium with Small diamond shape pyramidal heads, similar to needle holder Inserts, ensuring a firm multi-directional atraumatic grip. Interlocking atraumatic teeth designed for non-slip closure on the vessels. Triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. Should be US FDA Approved. | 1 | Nos | - | - |
| 3 | Titanium Ligaclips large with Small diamond shape pyramidal heads, similar to needle holder Inserts, ensuring a firm multi-directional atraumatic grip. Interlocking atraumatic teeth designed for non-slip closure on the vessels. Triangular shape of the titanium wire for the precision of the positioning of the clip into the jaws of the applier. Should be US FDA Approved. | 1 | Nos | - | - |
| 4 | Proximal aortic anastomosis device. It should provide stable blood field. It allows for up to three anastomosis from one insertion. Size – 3.5mm/4.0mm/4.5mm | 1 | Nos | - | - |
| 5 | Membrane Oxygenator (Plasma resistant) with integrated arterial filter.
Should have surface area with surface area of 1.4 m2. It should have radial blood flows design to give efficient gas transfer. It should have quick priming inlet and vacuum assisted venous drainage. Oxygenator Should have self-venting facility. Integrated arterial filter should be polyester/polycarbonate/equivalent material. Integrated arterial filter pore size should be less than 40 micron with the surface area of around 60-80cm2. Priming volume of around of less than 285ml visible path top to bottom should have maximum flow for large body surface area patient ranging from 0.5 to 6 L/M. Should have phosphoryl choline (PC) coating like phisio. Should be able to operate at venous reservoir level of minimum 150 ml. Oxygenator reservoir should have polycarbonate/polyester/equivalent screen type venous filter with pore size less than 50 micron. Should be US FDA Approved. Should be supplied with Appropriate stand. | 1 | Nos | - | - |
| 6 | UW Solution for organ transplant use. | 1 | Nos | - | - |
| 7 | Dacron Graft knitted Bioseal Grafts diameter 6mm to 8mm length 30 cm | 1 | Nos | - | - |
| 8 | Dacron Grafts knitted Bioseal diameter 6mm to 8mm length 60 cm | 1 | Nos | - | - |
| 9 | Dacron Grafts woven Bioseal diameter 20mm to 32mm length 30 cm | 1 | Nos | - | - |
| 10 | Aortobifemoral bioseal graft dacron sizes - 6x12x45 / 7x14x45 / 8x16x45 | 1 | Nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
BOQ_825236.xls
BOQ • 0.59 MB
TD.pdf
Tender Documents • 20.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .