Karnataka Power Transmission Corporation Limited
Augmentation of 2x8MVA 66/11kV Transformers by 2x20MVA, 66/11kV Transformers at 66/11kV B.Matakere S/s in Saraguru Taluk, Mysuru district-OTHERS-CALL1
KPTCL/2026-27/SS/WORK_INDENT3833
KPTCL/2026-27/SS/WORK_INDENT3833
Open
Sub-Station
KPTCL CEE Transmission Zone Office Mysuru
20 documents required · 18 mandatory · 2 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
The Bidder should have carried out erection of atleast One(01) No. of 66kV voltage class or above voltage class Sub-Station/ Additional Transformer work OR atleast One(01) No. of 66kV voltage class or above voltage class Transformer Replacement/ Augmentation work on Total or Partial Turnkey Basis in the last 10 years preceding the date of bid submission and shall be completed and commissioned prior to the date of submission of the Bid OR The Bidder should have carried out erection of atleast Two (02) Nos of Agumentation/Replacement of 66kV or above voltage class Transformer works on Labour Contract Basis in the last 10 years preceding the date of bid submission and shall be completed and commissioned prior to the date of submission of the Bid OR Bidder who has executed Additional Transformer works or Replacement of Transformer works of private firms under the direct supervision of ESCOM/KPTCL officers are eligible to participate. Such Bidder should have carried out erection of not less than Two (02) Nos. of 66kV or above voltage class Additional Transformer Work on Total or Partial Turnkey Basis in the last 10 years preceding the date of bid submission and shall be completed and commissioned prior to the date of submission of the Bid
The Bidder shall be registered firm as Sole Proprietorship/Partnership/Pvt Ltd Company etc
For other than proprietorship, the Bidder shall furnish the registered partnership deed and Power of Attorney
valid Super grade Electrical Contractor License issued by the Government of Karnataka as on the date of opening of techno-commercial bid (refer 2.3 of ITT)
3.6: Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:Assessed Available Tender Capacity: (AxNx5-B)Where A-Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years (updated to FY 2024-2025) taking into account the completed as well as works in progress. N-Number of years prescribed for completion of the works for which tenders are invited.B-Value, at FY 2024-2025 price level of existing commitments (KPTCL & Non-KPTCL)and on-going works (KPTCL & Non-KPTCL) to be completed during the next 1(One)year.Note:(i)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.(ii)A self-declaration is to be uploaded by the Tenderer stating that the information with regard to assessed available tender capacity (Works on Hand) furnished are correct.
Even though the Tenderers meet the above criteria, they are subject to be disqualified if they have:- Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements and/or- Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc. and/or- Participated in the previous Tender for the same work and had quoted unreasonably high Tender prices and could not furnish rational justification.
Minimum Average Annual Turnover (MAAT) of the bidder for best one(01) year out of last preceding five financial years, shall not be less than Amount Put to Tender as per 3.2(a) of std tender documents(ITT).
Valid Caste Certificate in support of reserved tender participation
Valid Karnataka Residential Certificate
Bidder shall ensure that soft copies of Power of Attorney, Letter of Undertaking, No Deviation CERTIFICATE as revised in Annexure , Any other undertaking / agreement (if applicable) are to be uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date as per 3.10(xviii) of ITT
Bidder shall ensure that soft copies of i. Letter of undertaking for Non performance ii. Letter of undertaking for Risk and Cost iii. Letter of undertaking for Litigation iv. Letter of undertaking to source the supply of equipment material from KPTCL approved Vendors only (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date as per 3.10(xviii) of ITT
i. Letter of undertaking to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India (Annexure-XVI) ii. Letter of undertaking as per clause No.1.5 of Annexure-XVII iii. Letter of undertaking as per clause No.1.6 of Annexure-XVII (if applicable) are uploaded besides submitting the Originals to the office of the Chief Engineer, Electy., Operation, KPTCL, Mysuru, after the last submission date and on or before the date and time of opening of techno commercial bids.
ESI certificate
EPF Certificate
Shall upload valid GST Certificate and PAN copy
Liquid Assets and/or availability of credit facilities of not less than 30% of the Amount put to tender(Credit lines/ Letter of credit/ certificates from Banks for meeting the fund requirement etc.) (30% of APT)
₹1,670
₹1.3 L
7 Jul 2026
7 Jul 2026
23 Jul 2026
20 Jul 2026
17 Jul 2026
Augmentation of 2x8MVA 66/11kV Transformers by 2x20MVA, 66/11kV Transformers at 66/11kV B.Matakere S/s in Saraguru Taluk, Mysuru district-OTHERS-CALL1
11kV GOS, Double Break 1200A for Bank-1&2 and Bus coupler
11kV GOS, Double Break 400A for 02 Outgoing feeders & 02 Capacitor Banks
Supplying & Erection of Double pole structure with all accessories using 9.Mts. RCC poles,145Kg WL suitable for mounting Roaster GOS.
11 kV class, 31.5 KA, NCT of ratio 1200-800 /1-1A
RCC Pole - 9.5 Mtr Long, 350 Kg WL for Bus ODS
Drake ACSR ( For Twin Drake Run)
Coyote ACSR for Capacitor Bank
Fabrication, galvanising and supply of Mild steel tower materials for Beam out of Channel 100 x 50, 1B2 4.00 metre Long (8 no's). (=0.0378MT/No=0.0378 x 08 Nos =0.3024)*4feeder = 32 (0.3024)
Pad clamp coyote
PG Clamp for Coyote to Rabbit
12.1 kV, 2.9 MVAr Star connected Capacitor Bank with 0.2% Series Reactor & NCT
Design, engineering, supply, erection of CapacitorBank with internal fuses, terminal connector,Neutral CTs & 0.2% series ...
33kV Class Post insulators- Cylindrical solid core 1Unit/stack (for LT side of Tr-1 ,Bank-1 and Tr-2 , Bank-2 due to age old & deteriorated)
Post insulator clamp suitable for Twin Drake ACSR Conductor 127/76 mm 66 kV
Terminal connector clamps for Twin Drake ACSR Conductor 127/76 mm 66 kV suitable to 11kV Bank CT's 1 & 2
Terminal connector clamps for Twin Drake ACSR Conductor suitable to 11kV Bushings of Power Transformer's.
C - Type Wedge Connector Double Drake to Single Drake for PT's 1 & 2
Terminal connector clamps for Twin Drake ACSR Conductor 127/76 mm 66 kV suitable to 11kV Bank 1&2 breaker limbs
Terminal connector clamps for Twin Drake ACSR Conductor 127/76 mm 66 kV suitable to 11kV Bank 1&2 GOS
11KV 90KN disc insulator ( Cross bus & to tap from 11kV BUS Breaker to GOS DP Structure)
Bolted type tension clamp for Single Coyote ACSR Conductor 70/90 kN, 16 mm
Supporting Base Insulator for running GI Flats on the DP Structure made up of Epoxy )
C - Type Wedge Connectors Drake to coyote ACSR Conductor
C - Type Wedge Connectors Coyote to coyote ACSR Conductor
9 kV, 10KA station class with connector and clamp (02 Feeders x 03)
Multi Funtional Transducer (MFT)
Contact Multiplier Relay (06x02)
Terminal Blocks (Knife) for PT (06x08)
Current Cables-Copper Core with c/s 4.0 sq.mm Multistrand 4 Core
Voltage Cables-Copper Core with c/s 2.5 sq.mm Multistrand 4 Core
Signal Cables-armoured Copper Core with c/s 0.5 sq.mm Multi strand 10 Core
Control Cables- Copper Core with c/s 1.5 sq.mm Multi strand 10 Core
19 Core 2.5 Sq.mm. Copper cable
4 Core 6.0 Sq.mm. Copper cable
4 Core 2.5 Sq.mm. Copper cable
Augmentation of 2x8MVA 66/11kV Transformers by 2x20MVA, 66/11kV Transformers at 66/11kV B.Matakere S/s in Saraguru Taluk, Mysuru district-OTHERS-CALL1
Erection of 2x20 MVA, 66/11kV Power TRANSFORMERs
Testing and commissioning of 2x20 MVA, 66/11kV Power TRANSFORMERs
11kV GOS, Double Break 1200A for Bank-1&2 and Bus coupler
11kV GOS, Double Break 400A for 02 Outgoing feeders & 02 Capacitor Banks
Supplying & Erection of Double pole structure with all accessories using 9.Mts. RCC poles,145Kg WL suitable for mounting Roaster GOS.
Erection of 11 kV class, 31.5 KA, NCT of ratio 1200-800 /1-1A
Testing & commissioning of 11 kV class, 31.5 KA, NCT of ratio 1200-800/1-1A
RCC Pole - 9.5 Mtr Long, 350 Kg WL for Bus ODS
Formation of Main/Cross bus with Double Drake 11kV
Formation of Main/Cross bus with Single Coyote 11kV
Fabrication, galvanising and supply of Mild steel tower materials for Beam out of Channel 100 x 50, 1B2 4.00 metre Long (8 no's) (=0.0378MT/No=0.0378 x 08 Nos =0.3024)*4feeder = 32
33kV Class 1Unit/stack (for LT side of Tr-1 ,Bank-1 and Tr-2 , Bank-2 due to age old & deteriorated)
9 kV, 10KA station class with connector and clamp (02 Feeders x 03)
Configuration of RTU and Engineering along with validation of data at SLDC ( 06 Breakers)
Laying copper cable of 19 Core 2.5 Sqmm
Laying copper cable of 4 Core 6.0 Sq.mm.
Laying copper cable of 4 Core 2.5 Sq.mm.
Erection of 11kV Switchgears
Testing & Commissioning of11kV Switchgears
Grounding of equipments by providing cast iron pipe of 100mm ID 13mm thickness, 2.75mtrs long with 2 part clamp out of G.I.Flat 50x6 mm continuously welded around the pipe
Supplying and Grounding of Equipment with G.I.Flat 50x6mm and connecting Equipment to the earth mat/ground pit.
Supplying and fixing of 450mm diax 450mm height 1.5" to 2" hume pipe collars for earth pits.
Dismantling of 2x8 MVA 66/11 KV, Transformer and parts like Radiator, Bushings, etc., as per the direction of site Engineer (23.6MT+20.08MT=43.68)
Moving of both Transformer from the plinth to the loading point as per direction of site Engineer.
Releasing of 11kV NCT 1 & 2 of 800-400/1-1-1A & 800-400/1-1-1A respectively
Releasing & re-erection of existing NCT mounting structure (0.157MT),
Note: Unit rate doubled due to R & R work, (0.157*2=0.314 MT )...
Releasing & reconnection of existing HPI mounting structure (0.231 MT per Structure) Note:...
Releasing of existing 11kV PCVCB S/G of Bank -1 & Bank 2
Releasing of existing 11kV 400A GOS
Releasing of existing 33kV Post insulators
Augmentation of 2x8MVA 66/11kV Transformers by 2x20MVA, 66/11kV Transformers at 66/11kV B.Matakere S/s in Saraguru Taluk, Mysuru district-OTHERS-CALL1
Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depthnot exceeding 300mm as per drawing and tec...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, includi...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of appro...
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2...
Finishing walls with water proofing cement paint of required shade :Newwork (Two coats applied @ 4.84 kg/10 m²) to give an even shade afterthoroughly brooming the surface to remove all dirt, dust, mo...
Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 25mm including the cost of materials, labour charges, required tools and plants etc., complete. W...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
credit facility certificate FORMAT new format.doc
Commercial Information / Worksheet • 0.06 MB
NIT-Mys Aug B Matkere.pdf
Instructions to Tenderers • 0.56 MB
FORMATS TO BE SUBMITED.docx
Commercial Information / Worksheet • 0.07 MB
Td-Mys Aug B Matkere.pdf
Tender Document • 2.23 MB
Work on Hand details format.doc
Commercial Information / Worksheet • 0.06 MB
Tech Volume II A B.zip
Technical Information / Worksheet • 19.19 MB
Download all tender documents and submit your bid