| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | ₹19.4 L Quoted ₹20.6 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹21.5 L+₹95,550 (4.65%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹21.5 L+₹95,550 (4.65%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹22.4 L+₹1.8 L (8.99%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹22.4 L+₹1.8 L (8.99%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹22.8 L+₹2.2 L (10.8%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹22.8 L+₹2.2 L (10.8%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹26.0 L+₹5.4 L (26.4%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹26.0 L+₹5.4 L (26.4%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
24 Dec 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-47/2020-21 REPAIRS / MAINTENANCE OF LT PANEL, FEEDER PILLAR BOXES AND CONNECTED ITEMS IN TECHNICAL AREA AT AF STATION AMBALA UNDER GE (AF) AMBALA
2020_MES_398592_1
GE AF/AMB-47/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMETNS
9 documents required · 9 mandatory
₹500
GE AF AMBALA
₹50,000
Yes
8 Feb 2021
26 Nov 2020
26 Dec 2020
26 Nov 2020
24 Dec 2020
11 Dec 2020
2 Dec 2020 - 7 Dec 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for plain cement concrete in 1:3:6 (type C-2) using 40mm graded stone aggregates as bed blocks, foundation, bed to air termination rods complete all as specified and as directed
Supplying, fixing / laying steel water tubing, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete including taking out and disposing old tubing all as specified and as directed for the following bores:
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V (earthed) grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including taking out / down old unserviceable cable, protection pipes, brick covers, etc. from any location and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
3.5 core 240sqmm
3.5 core 150sqmm
3.5 core 120sqmm
3.5 core 95sqmm
3.5 core 70sqmm
3.5 core 50sqmm
3.5 core 35sqmm
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for carrying out tests for locating faults in LT cable of any size with the help of fault locator machines, etc. at any location complete all as specified and as directed
M&L for carrying taking out defective underground cable of any size for checking faults / damage and relaying the same on rectifying the fault / defect at any location / position and testing on re-connecting up including relaying of sand bed, cable covers/ brick protection, filling in, etc. complete all as specified and as directed
M&L for boring into roads / paths / hard standing, concrete / tiled / bituminous, etc. for insertion of GI protection / passing through pipes at any length at any location including making good the disturbed surfaces after laying of pipes complete all as specified and as directed
80mm bore
50mm bore
M&L for cable jointing kit for 1.1kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 25 to 50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 25 to 50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 70 to 150mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 70 to 150mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for straight through heat shrink type joint indoor / outdoor with jointing material and accessories suitable for 3.5 core, 185 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end joint heat shrink type joint outdoor with jointing material and accessories suitable for 3.5 core, 185 to 300mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for disconnecting from mains and taking down old / unserviceable feeder pillar boxes / bus bar chambers of any size at any location including breaking down old PCC platform, etc. and disposing off complete all as specified and as directed
M&L for disconnecting from mains and taking down old / unserviceable LT panels of any size at any location including breaking down old PCC platform, etc. and disposing off complete all as specified and as directed
S&F bus bar chamber of size 600x600x450mm suitable of 3 phase and neutral 433V outdoor type fabricated out of 3.15mm thick MS sheet with 400A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
S&F bus bar chamber of size 600x600x450mm suitable of 3 phase and neutral 433V outdoor type fabricated out of 3.15mm thick MS sheet with 200A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrom primer complete all as specified and as directed
M&L for carrying out repairs / maintenance of existing LT panels at any position / location and of any size, by disconnecting connections, etc. cleaning the entire compartments, arranging cables in proper manner, changing burnt lugs by providing new lugs, thimbles, etc., taping with insulated tapes of all naked cable joints/ends, preparation of old treated surfaces and applying one coat of grey synthetic enamel paint including all necessary welding works to reinstate broken / damaged doors, hinges, supports, legs, etc. and cleaning the surrounding upto 2m all around complete all as specified and as directed
Supply, installation, testing & commissioning of powder coated compartmentalized cubical LT panel, of suitable size, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 600A rated aluminium bus bar with neutral, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 415V, 50Hz, 3 phase, 4 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), painting all exposed metal surfaces of legs with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned and connecting up complete all as specified and as directed
Panel with the following switchgears: (i) MCCB three phase adjustable type with thermal magnetic release 400A 35kA FP - 1No. (ii) MCCB three phase adjustable type with thermal magnetic release 200A 35kA FP - 4Nos. (iii) MCCB three phase adjustable type with thermal magnetic release 100A 16kA FP - 2Nos. (iv) 3 phase Digital ampere meter and voltmeter
Panel with the following switchgears: (i) MCCB three phase adjustable type with thermal magnetic release 400A 35kA FP - 1No. (iii) MCCB three phase adjustable type with thermal magnetic release 200A 25kA FP - 2Nos. (iv) MCCB three phase adjustable type with thermal magnetic release 125A 25kA FP - 4Nos. (v) 3 phase Digital ampere meter and voltmeter
Supply, installation, testing & commissioning of powder coated compartmentalized cubical LT panel, of suitable size, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 400A rated aluminium bus bar, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 240V, 50Hz, 1 phase, 2 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned and connecting up complete all as specified and as directed (i) MCCB three phase adjustable type with thermal magnetic release 250A 35kA FP - 1No. (ii) MCCB three phase adjustable type with thermal magnetic release 125A 25kA FP - 5Nos. (iii) Digital ampere meter and voltmeter
Notes for serial item Nos. 35 to 38: (i) The location of installation shall be as directed by the Engineer-in-charge (ii) Panels shall be of make as detailed hereinafter (iii) Contractor shall submit shop drawings from CPRI approved manufactures / fabricators for approval before procurement (iv) Drawings of panels showing location of switchgears shall be got approved from the GE before incorporation at site
Supplying, fixing and testing in repairs sheet metal enclosures made out of 2mm thick powder coated MS sheet suitable for mounting 4P MCCB 100 to 200A 240V, double door, including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
Supplying, fixing and testing in repairs sheet metal enclosures made out of 2mm thick powder coated MS sheet suitable for mounting 4P MCCB 250 to 400A 240V, double door, including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs MCCB 4P 100A 415V 50Hz 16kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 125A 415V 50Hz 16kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 160A 415V 50Hz 25kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 200A 415V 50Hz 25kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 250A 415V 50Hz 25kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 400A 415V 50Hz 35kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs MCCB 4P 630A 415V 50Hz 50kA with adjustable thermal release fixed magnetic protection type complete all as specified and as directed
S&F in repairs offload change over switch 4P 250Amp 415V with and including suitable sheet metal enclosure and side operating handle complete all as specified and as directed
S&F in repairs offload change over switch 4P 400Amp 415V with and including suitable sheet metal enclosure and side operating handle complete all as specified and as directed
S&F in repairs TPN switch disconnector fuses 400A with and including suitable sheet metal enclosure and side operating handle complete all as specified and as directed
Supplying, fixing, connecting and testing 25kW equally distributed over 3 phases (7kW/Phase) automatic street light nature switch for automatic switching on/off of street lights based on LUX level of natural ligh, infra-red sensor based with contactor 63A per phase, MCB SP for input and output 100A and connecting up with 16sqmm copper PVC insulated cable, mounted on and including rust proof, shock proof, termite proof, FR grade SMC junction boxes on poles / walls including disconnecting and disposing off old unserviceable nature switch complete all as specified and as directed
Supplying, fixing, connecting and testing door safety sensor device as per existing type and model suitable for lift (14 passenger) of suitable IP rate, anti-interference ability, light resistance and strong electromagnetic tolerance (EMS) including disconnecting and disposing off old unserviceable sensor complete all as specified and as directed
S&F LED sign boards with LED strips of size 2.0x1.0m 150mm thick fabricated with 1.6mm thick aluminium sheet supported on MS angle (40x5mm) frame all around in both faces duly embedded in PCC 1:3:6 type C2 bed suitably below ground with all necessary connecting up, etc. controlled by one independant single phase 230V MCB SP 6A, 10kA duly housed in weather proof box IP-66, for fixing at any locations complete all as specified and as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting surfaces of any description with one coat of black synthetic enamel paint complete all as specified all as directed
M&L for preparation of surfaces viz. scrapping old paints, smoothening, etc. and painting entirely (including covers from both sides) to external exposed concrete / brick surfaces of earthing pits of any size with two coats of synthetic enamel paint (of approved tint) complete all as specified all as directed
S&F rectangular CI earth pit cover fabricated out of 10mm thick with handle, of size 12x12inch duly hinged in mild steel angle iron frame all round made out of MS angle iron of size 40x40x6mm thick duly fixed to existing earthing pits and entirely painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer including dismantling and taking down old pit cover and disposing off complete all as specified and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws, taking down and siposing off old unserviceable block complete all as specified and as directed
S&F in repairs air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed
M&L for brazing / welding works on joints of any type of earth strip complete all as specified and as directed
S&F in repairs identifier legend plate of GI of size 300x200x1.6mm mounted on 25mm dia GI pipe of 0.9m length including cutting to required shape/size, welding, marking, necessary painting and writing the date, type of earth pit and resistance value, etc. having approved font type and size complete all as specified and as directed
S&F mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes conforming to Fe 410-W (Grade-E-250) quality-A complete all as specified and as directed
S&F synthetic insulating mat of size 2x1m x 25mm thick suitable for HT 11000V installation including bolting, etc. complete all as specified and as directed
M&L for preventive maintenance to functional earthing GI plate / copper plate, any type, by mechanically checking earth resistance value and bringing up the same to required state by developing and adding new common salt, charcoal, etc. and ensuring required earth resistance value on completion including all necessary excavation/earthwork complete all as specified and as directed
M&L for preventive maintenance to functional chemical earthing any type, by mechanically checking earth resistance value and bringing up the same to required state by developing and adding new chemical mixture of sodium carbonate, magnesium sulphate, etc. and ensuring required earth resistance less than 1Ohm value on completion including all necessary excavation/earthwork complete all as specified and as directed
S&F in repairs copper strip of size 20x3mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F in repairs GI strip of size 32x6mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F in repairs aluminium strip of size 25x3.15mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
S&F PVC / porcelain insulators fixed on walls, etc. complete all as specified and as directed
M&L for earthing using GI earthing strip with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
M&L for earthing using copper earthing strip with galvanised steel earth plate electode 600x600x3mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 20x3.15mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item Nos. 70 & 71: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge (iv) The earth resistance shall be less than 01Ohm / as desired by the installation. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect
Supply, installation, testing and commissioning maintenance free tripod chemical earthing system consisting of 3Nos. of solid copper earth rod of 10ft length, 17.2mm dia and 3m long on outer surface having 250microns (minimum thickness) with exothermically jointed copper bus bar of 900x600x5mm for long lasting and connecting each copper rod and the exothemically jointed bus bar, both CPRI tested on at leat 25kA fault current ensuring high current carrying capacity of the system and earth rod should be certified by laboratories confirming to comply with UL 467 international standards grounding and bonding equipment and each rod should be used with minimum 50kg earth enhancing compund that should be ROHS tested and have passed leaching sulpher, corrosion, resisitivity test shall be less than 0.05lhm mtr and international standard for earth enhancement compound by NABL acredited laboratory and each rod should be interconnected with 8mm dia copper clad steel conductor at the distance of 3m to make a shape of traingle with top of the bore finished with 40mm thick PCC in 1:2:4 type B-1, 75mm thick PCC in 1:4:8 type D-2 and back fill/JAM compund shall be covered with advanced polymer pit cover of 30x30mm size complete all as specified and as directed
Notes for item No. 73: (i) The earthing shall comply to IS 3043, UL 467, BS/EN50164-7 (ii) The earth resistance shall be less than 01Ohm. A guarantee for 3years of this criterion on a Rs. 100 stamp paper shall be given by the Contractor. The quoted rate shall be deemed to be inclusive of this aspect (iii) To obtain earth resistance less than 01Ohm, if a combination two or more earthings are to be inter-connected or the length of the electrode/s is/are to be increased it shall be measured and paid as one earthing only (iv) Testing of earthing shall be carried out in presence of Departmental rep and requisite test reports shall be submitted (v) Cost of all excavation & earthwork required shall be deemed to be included in the quoted rate
NAVREET CONSTRUCTION
M/S Sonu Traders
Esha Engineers
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .