Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹16.7 CrAccepted-AOC D NO 58 21 50 BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹16.7 Cr | L 1 | Accepted-AOC Being lowest tender and accepted |
| 2 | L 2₹17.3 CrRejected-Finance | ₹17.3 Cr | L 2 | Rejected-Finance Not being Lowest |
| 3 | L 3₹18.9 CrRejected-Finance | ₹18.9 Cr | L 3 | Rejected-Finance Not being Lowest |
| 4 | L 4₹20.3 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹20.3 Cr | L 4 | Rejected-Finance Not being Lowest |
| 5 | L 5₹20.6 CrRejected-Finance | ₹20.6 Cr | L 5 | Rejected-Finance Not being Lowest |
| Sl No | Description | Qty | Unit | PJR PROJECT CONSTRUCTIONS PRIVATE LIMITED L1 | Komal Buildcon Pvt. Ltd. L2 | jd constructions L5 | DES RAJ AND SONS BUILDERS PVT LTD L3 | SVS PROJECTS L6 | SOOD ASSOCIATES PVT LTD L4 |
|---|---|---|---|---|---|---|---|---|---|
| .10Schedule "A" Part – I to Schedule "A" Part – XIV: NOTE: Schedule "A" Part – I to Part – XIV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only | |||||||||
| 1.00 | Lumpsum price worked out by the contractor for "Buildings/Structures" as listed in Schedule "A" Part – I | 1 | EACH JOB | 12,70,66,550 ₹12.7 Cr | 11,79,51,960 ₹11.8 Cr | 14,04,19,000 ₹14.0 Cr | 13,26,95,955 ₹13.3 Cr | 18,35,69,999 ₹18.4 Cr | 13,93,37,773.7 ₹13.9 Cr |
| 2.00 | Lumpsum price worked out by the contractor for "SITE CLEARANCE & AREA DEVELOPMENT/ EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II | 1 | EACH JOB | 8,36,784.58 ₹8.4 L | 7,02,899.05 ₹7.0 L | 6,57,020 ₹6.6 L | 7,53,106.12 ₹7.5 L | 9,72,599 ₹9.7 L | 8,95,359.5 ₹9.0 L |
| 3.00 | Lumpsum price worked out by the contractor for "PILE FOUNDATION" as listed in Schedule "A" Part – III | 1 | EACH JOB | 90,00,000 ₹90 L | 88,35,094.24 ₹88.4 L | 94,25,652 ₹94.3 L | 86,45,092.21 ₹86.5 L | 89,94,199 ₹89.9 L | 1,14,73,272.38 ₹1.1 Cr |
| 4.00 | Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV | 1 | EACH JOB | 16,93,464.29 ₹16.9 L | 16,93,464.29 ₹16.9 L | 18,26,284.98 ₹18.3 L | 20,15,222.5 ₹20.2 L | 21,29,999 ₹21.3 L | 21,29,870.04 ₹21.3 L |
| 5.00 | Lumpsum price worked out by the contractor for "ROADS, PATH, HARD STANDING AND CULVERTS", as listed in Schedule "A" Part – V | 1 | EACH JOB | 24,73,229.95 ₹24.7 L | 28,68,946.74 ₹28.7 L | 28,70,400 ₹28.7 L | 29,18,411.34 ₹29.2 L | 32,58,599 ₹32.6 L | 27,39,596.82 ₹27.4 L |
| 6.00 | Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VI | 1 | EACH JOB | 7,64,819.28 ₹7.6 L | 7,64,819.28 ₹7.6 L | 8,37,374 ₹8.4 L | 7,64,819.28 ₹7.6 L | 8,55,599 ₹8.6 L | 9,61,913.21 ₹9.6 L |
| 7.00 | Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – VII | 1 | EACH JOB | 20,00,694 ₹20.0 L | 20,00,694 ₹20.0 L | 20,50,605 ₹20.5 L | 18,00,624.6 ₹18.0 L | 23,20,799 ₹23.2 L | 25,16,272.84 ₹25.2 L |
| 8.00 | Lumpsum price worked out by the contractor for "ARBORICULTURE", as listed in Schedule "A" Part – VIII | 1 | EACH JOB | 24,910.45 ₹24,910.45 | 24,910.45 ₹24,910.45 | 24,910.45 ₹24,910.45 | 36,120.15 ₹36,120.15 | 62,699 ₹62,699 | 36,618.36 ₹36,618.36 |
| 9.00 | Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part –IX | 1 | EACH JOB | 1,91,917.56 ₹1.9 L | 1,91,917.56 ₹1.9 L | 1,91,917.56 ₹1.9 L | 2,39,896.95 ₹2.4 L | 2,53,499 ₹2.5 L | 3,39,694.08 ₹3.4 L |
Updated dates
Tender Value
₹16.9 Cr
EMD Value
₹11.7 L
Closing Date
19 Mar 2026, 6:00 pmClosed
The Chief Engineer (Navy)
The Chief Engineer (Navy), Military Engineer Services, Station Road, Visakhapatnam-530 004
PROVISION OF DEFICIENT TYPE-II AND TYPE-III MD ACCN OF DEFENCE CIVILIANS AT ASHOKA PARK VISAKHAPATNAM UNDER GE(P) NO. 2 (NAVY) VISAKHAPATNAM
2025_MES_740242_1
85452
Open Tender
Civil Works
660 days
VISAKHAPATNAM
Please refer Tender documents
11 documents required · 11 mandatory
₹3,000
Garrison Engineer (P) No. 2 Navy Visakhapatnam
₹11.7 L
Yes
13 May 2026
18 Nov 2025
26 Mar 2026
30 Dec 2025
19 Mar 2026
12 Mar 2026
Schedule "A" Part – I to Schedule "A" Part – XV: NOTE: Schedule "A" Part – I to Part – XV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "Buildings/Structures" as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE & AREA DEVELOPMENT/ EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "PILE FOUNDATION" as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "ROADS, PATH, HARD STANDING AND CULVERTS", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "ARBORICULTURE", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part –IX
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part –X
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "FIRE ALARM & DETECTION SYSTEM", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "DISMANTLING & DEMOLITION", as listed in Schedule "A" Part – XV
Schedule "A" Part - XVI: (Miscellaneous Items) (Area Drainage, Arboriculture, External Water Supply, Internal Electrification, External Water Supply, External Electrification, Lightening Protection, Fire fighting system, Fire Alarm & Detection System, Lift, Aviation Light, DG Set, Hot Water Supply, Misc Items (TV & Telephone), Dismantling & Demolition)
Area Drainage
Supply and Fixing of the SFRC Factory made Cover Slabs (1.0 m x 0.6 m x 0.075 m) for the drain, complete all as specified and directed.
Arboriculture
Supply & Planting carpet Grass by piece turfing including preparation of ground upto 30 cm deep and filling soft soil, cow dung and watering etc complete all as specified and directed. (Note : Loose soil and cow dung will measured separately under relevant items as supply only)
Supply only approved loose soil of best quality for plantation
Supply only approved Vermi Compost/ Cow dung of best quality
Supply and Planting of the Draught Tolerant plants including preparation of soil for plantation complete all as specified and directed.
Supply and Planting of the Ashoka Plant including preparation of soil for plantation complete all as specified and directed.
Supply and Planting of the Royal Palm tree including preparation of soil for plantation complete all as specified and directed.
Supply and Planting of Jamun of height not less than 1.50 m including preparation of soil for plantation complete all as specified and directed.
Supply, fixing, testing and commissioning sprinklers complete all as specified and as directed
M&L for Maintenance of the plants and grass planted in above items by weeding hosing saucer melding once in every 15 days, planting new plants/grass of same species and height without any extra cost to the department and as directed by the Engineer-in-charge complete for the period of maintenance period of Two years.
External Water Supply
M&L for Cutting existing DI/MS pipe line of 150 mm dia for alterations or additions necessarily done in position without taking down and inserting Tee of 150x150x100 mm and including Tee for tapping all as specified and directed.
M&L for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 100 mm dia pipe conforming to IS-8329 including testing and commissioning all as specified and as directed.
M&L for Monoblock pump set suitable for 415 V, 3 phase of minimum capacity 5 HP, 60 mtr head and 250 LPM incl. accessories complete all as specified and directed.
M&L for LT Panel board made out of CRCA sheet 2 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required with and inclusive of the following items: (Pump House Panel)
Incoming:
(a) LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 32 Amp rated complete with overload protection, no-volt thermal based release - 01 No
Outgoing:
(b) MCB C-Curve, 32 Amp TPN, 50 Hz, 240/415 Volts complete - 03 Nos (02 for pumps and 01 for spare)
(c) MCB C-Curve, 16 Amp TPN, 50 Hz, 240/415 Volts complete - 01 Nos (for pumps house bldg)
d) DOL starter for 3 phase pumpset of minimum capacity 5 HP complete - 02 Nos.
(e) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases-01 set of 03.
M&L for earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron earth strip 32×6mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete. Note: Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.
M & L for flanged end lift type Foot valve 80 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets confirming to IS 4038 complete all as specified and directed.
M&L for valve chamber of internal size 1.0x1.0x1.0m comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200mm thick brick wall in CM 1:6, 15mm thick plastering in CM 1:4 internally and externally up to 50mm below GL,100mm thick PCC 1:3:6 type B1 as in copings, 3mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as directed.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Internal Electrification
Supply and fixing LED adore lamp for AC 240Volt supply, B22 type, CDS five star, 12 watts of five star rated complete all as specified and as directed.
Supply and fixing ceiling fan, AC single phase 230 V of size 1200 mm sweep, copper wound with complete set and fixtures such as canopy, down rod etc. 5 Star rating, wit brushless direct current motor (BLDC) including making necessary electric connection from ceiling rose to fan connectr with twin core flexible copper wire all as specefied and directed.
S&F Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as spcified and as directed.
S&F Exhaust fan 300 mm sweep, (Heavy duty), complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
S&F Energy efficient LED tube light fitting with tube 5 watts or nearest size, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
S&F Energy efficient LED tube light fitting with tube 10 watts or nearest size 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
S&F Energy efficient LED tube light fitting with tube 20 watts or nearest size, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
S&F LED Security light fitting with tube 30W New generation Energy saving &environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc complete all as specified and as directed.
S&F concealed in wall Vertical MCB DB double door type, TPN 4 way 415V, 50Hz, IP 43 protection, including provision for fixing MCCB FP as incomer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specified and directed.
S&F RCBO, DP, 240V, 50Hz, 16KA of capacity 20 Amp all as specified and directed.
S&F MCB SPN, 6 to 32 Amps 240 Volts, 10KA, C curve all as specified and directed.
S&F MCB SP, 6 to 32 Amps 240 Volts, 10KA, C curve all as specified and directed.
Supply, install, testing and commissioning integrity of Smart Meter single phase as per BIS 16444 with communication technology including cellular/RF/Hybrid (Cellular + RF ) AC whole current, Smart Energy Meter of rating 10-40 Amps complete as per specifications, meter shall have the ability to communicate with Head End System (HES) on any one of the communication technologies mentioned in IS 16444 Part I (RF/ Cellular) in a secure manner, in case of Cellular based meter, the meter shall accommodate e-SIM / SIM of any service provider, the Smart Meter shall have a dedicated sealable slot for accommodating plug-in type, bi-directional communication module which shall integrate the respective communication technology (RF/PLC/Cellular) with the Smart Meters, leading to easy adaptability for network interfaces (WN/NAN), the Plug-In module shall be field swappable / replaceable complete all as specified and directed.
Note: (i) Meter Specification may please be read in co-junction with the relevant PS clause.
(ii) 15 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey
for cumulative energy and max demand of software.
(iii) Meter should have connect / disconnect functionality operate able from MDM/ billing software and prepaid features would be configured in MDM/ billing end as per prevalent IS and applicable tariff plan.
(iv) Meter should support communication protocol through RF (4G/5G/NB/IOT) with the software all as required at site and directed (cost of 4G/5G/NB IOT SIM, mapping vending portal charges etc. deemed to be included the unit rate quoted for meter).
(v) Two way communication with DCU/HES.
(vi) Clock synchronisation facility with HES (Head end system).
(vii) In case of RF, communication including different makes of meter shall be such that it should communicate with same DCU directly via mesh network.
(viii) Guarantee of meter shall be 10 years from date of completion.
(ix) The cost of meter shall include DCU / repeater cost in case of RF communication meters.
(x) The OEM shall need to share the Authentication / Encryption keys of the meters along with relevant protocol details with the department.
(xi) A training to handle the smart meter to MES tradesmen shall also be given by professionals.
External Electrification
(xii) The Contractor / OEM will be held responsible for interface with the existing server of any make of MES at Visakhapatnam and testing the system complete all as specified and directed by Engineer-in-Charge.
Supply and Installation , testing and commissioning distribution Transformer step down, outdoor type, 11//0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of 2.5% continuous rating of 250 KVA outdoor type confirming to (IS 1180, level-II) with and including the following: (a) Lifting lugs/ hooks for transformer and tank. (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve with dummy plug. (f) Conservator with level gauge. (g) Silica gel breather (h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335. (i) Type of connection : Delta/Star. (j) Type of cooling : ONAN. (k) Vector Group : DYN 11. (l) Type of connecting arrangement : Cable termination boxes on both HT and LT side. (m) Temperature rise over an ambient of 50 degree centigrade maximum. (n) All necessary arrangements with devices for measuring the temperature of core, winding and oil. (o) In addition to the above all standard fittings shall be provided as per IS norms.
Supply and fix 11KV Outdoor type of Ring main unit one incoming two outgoing SF6 filled load break switch each of 11 KV, 630 Amp complete all as specified as directed.
Supply and fix time switches 250 V single Phase of 25 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed.
Incoming:
Supply and fix sandwich type bus bar trunking system indoor for the complete bldg power supply three phase of rating 320 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 1.6 mm thick (Non painted) IP54 rating including end feed unit with MCCB 250 A 25 KA 4P with rotary handle, termination links of bldg including provision of the following:- a) Supply and fix Straight feeder - 40 RM b) Supply and fix End Cover - 01 Nos c) Supply and fix end feed Unit with 320A 25kA 4P TM based MCCB - 01 Nos d) Supply and fix 63 A TAP OFF Box with 63 A 25 kA 4P TM based MCCB- 12 Nos
Outgoing:
a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 500 A breaking capacity 36 kA, Manual draw out type - 01 No
a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 320 A breaking capacity 36kA, Manual draw out type - 02 No (Bus bar trunking & Spare).
b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A breaking capacity 16 kA with adjustable type thermal and magnetic setting relays - 02 No. (APFC Panel , Spare).
Dismantling & Demolition
c)Automatic Star delta starter of capacity 10 HP for Jockey pump - 01 No
d)Automatic Star delta starter of capacity 90 HP for Fire pump - 01 No
Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed.
c) MCCB AC 3 Phase 415 V, 50Hz 4 pole 160 A breaking capacity 16 kA with adjustable type thermal and magnetic setting relays - 02 No. ( FF Panel & Spare).
Incoming :-
a) MCCB AC 3 Phase 415 V, 50 Hz 4 pole 63 A breaking capacity 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.
Outgoing :
a) MCCB AC 3 Phase 415 V, 50H z 4 pole 40 A breaking capacity 25kA with adjustable type thermal and magnetic setting relays - 03 Nos (Lift machine rooms, fresh water pumps & Spare).
c) MCB TPN AC 3 Phase 230 V, 50 Hz, 32 A capacity 10kA - 03 Nos. (Street Light, Booster pump & Spare).
d) MCB SPN AC 230 V, 50 Hz, 20 A capacity 10kA - 02 Nos. (Common area & Spare).
e) DOL starter of capacity 5 HP for Fresh water pump - 01 Nos
f) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs
g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip 32×6mm s
M&L for LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (Main LT Panel).
M&L for LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchgear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (Stand by DG supply panel)
ize by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on complete Note: Rate quoted deemed to include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
S&F Loop in loop out box of FRP made with IP 65 protection of thermoplasic of size 205 x 255 x 112mm with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as PVC connector heavy duty 32Amps,4 way for cable with necessary fixing arrangemets and with cable glands, etc all as specified and directed.
Supply and fix sheet metal enclosure, provision of fixing incoming and out going cables with bus bar for cable connection tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. (For lift machine room) Incoming:- (a) MCCB 40 Amps, 25 KA - 01 Nos Outgoing:- (a) MCCB 25 Amp,16 KA TPN - 03 Nos(for 02 lift + 01 Spare) (b) MCB SPN 20 Amp, 10 KA - 04 (For lighting & Utility) (c) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply and fix sheet metal enclosure, provision of fixing incoming and out going cables with bus bar for cable connection tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. (For Pump House) Incoming:- (a) MCCB 40 Amps, 25 KA - 01 Nos Outgoing:- (a) MCCB 25 Amp,16 KA TPN - 03 Nos (for 02 pumps + 01 Spare) (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Lightening Protection
Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws including provision of 30 cmx25cmx8cm sheet metal box made out of 3.15 m thick CRCA sheet with front hinged door shutter & locking arrangement and duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and as directed.
Each Set
Incoming:
Fire fighting System
Outgoing:
Supply and fix control panel for operating Electrical driven pump sets, up to 90 HP rated pump sets including provision of the following complete all as specified and as directed.
a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 160 A breaking capacity 50kA, Manual draw out type - 01 No
a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 125 A breaking capacity 36kA, Manual draw out type - 02 No (electric pump & Spare).
b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A breaking capacity 36 kA with adjustable type thermal and magnetic setting relays - 02 No. (Jockey pump & Spare).
c)Automatic Star delta starter of capacity 10 HP for Jockey pump - 01 No
d)Automatic Star delta starter of capacity 90 HP for Fire pump - 01 No
e) Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers.
f) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breakers.
Supply and lay Ductile Pipe with double flanged centrifugally cast (Spun) Class k-9 of 150 mm dia conforming to IS-8329 including provision of special such as tees, elbows, bends, reducers, taper pieces including testing and commissioning. (For Yard Hydrant)
Supply and fix flanged end lift type Foot valve 80 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed. (for Jockey pump)
Supply and fix flanged end lift type Foot valve 150 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed. (for fire pumps)
Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 all as specified and directed.
Supply and fix LED EXIT light double sided with battery back-up up to 2 Hrs. complete with all accessories as directed.
Supply and install Fire Extinguisher CO2 Type light weight squeeze grip type confirming to IS:15683 of capacity 4.5 Kg all as specified and directed. Note: (1) Fire extinguisher should equipped with hose of appropriate size and open-close should be with the help of wheel type valve.
Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 40 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering all as specified and directed and tested on completion.
Set of four
Each set
Fire Alarm & Detection System
Supply and fix Control Console all as specified and as directed.
Taking down old unserviceable sub main wiring of any description.
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and as directed.
Supply, design & install testing & commissioning passengers lift of capacity 8 passenger lift (544 Kgs capacity) in the adjusting lift well, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve 12 floors (G + 11) upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified.
Aviation Light
DG SET
S&F Aviation obstruction light LED type 10 Watt including standard fixing arrangements complete all as specified and as directed.
S&F Cable PVC insulated armoured PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable clamps spacers bolts nuts complete all as specified and as directed.
Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed.
Silent engine generating set with acoustic enclosure as per latest CPCB norms 415 volts 30 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:-
(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design
(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.
(A) Alternator :- Standard design alternator rated at 30 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722
i) Insulation class - 'H‘ ii) Temperature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under
i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System : Lubricating oil filter Lubricating oil pump
vi) Air Intake System : Air intake Manifold Air cleaner dry t
ype vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan
Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display.
xi) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine
xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling
xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms
xvi) MS pipe line to and from the fuel tank to the DG Set
C) AMF Panel :- Factory made inbuilt type control cubical type made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 30 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, PF, temperature, Battery voltage, etc
g) Annuciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temperature.
(iii) Engine over speed. (iv) Battery low voltage
Controls :- a) Load on Indication b) Load off indication c) Engine start push button d) Engine stop push button e) Fault accept / reset push button
f)Battery charger (i) Transformer shall be dry type, double wound, with copper conductor and Class–B insulation with temperature rise limited to Class-A insulation. (ii) Isolating switch shall be heavy duty, load break type, operated by an external handle. (iii). Fuses shall be HRC type and arranged for easy replacement. Semiconducting devices fuses shall be fast-acting type. (iv). Indicating meters (voltmeter and ammeter) shall be 96mm x 96mm, flush type 90 degree scale with antiglare glass, + 1% accuracy with zero adjuster on the front of the meter. (v.) The following indications/alarm annunciation shall be provided: a) Failure of input AC supply to the charger b) Low battery voltage c) DC output fuse blown d) Charger fail e) Over voltage f) Earth fault g) Battery on boost charge directed.
D) Acoustic Enclosure:- Manufactured by OEM suitable for 30 KVA DG Set (i) NAL approved as per latest CPCB norms (ii) It Should be as per latest rules and regulations of Ministry of Environment and Pollution control board
(iii) The generating set batteries and control panel should be inside the enclosure. (iv) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms
v) The acoustic should be composite in construction and fully assembled integral unit
vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form
vii) The DG Set should be provided with external Emergency stop push button viii) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings. ix) The noise level should be 75 dba at 1m under free field conditions.
x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade
E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 3.0 x 0.8 m for placing of DG Set complete all as specified and directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 X 6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel using galvanised iron strip 32×6mm and 50 mm dia light grade GI pipe upto test point or 7.5 mtr and GI pipe 20 mm medium grade for watering pipe as earthing lead all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion. all as specified and as directed.
HOT WATER SUPPLY
Supply, install, testing and commissioning of storage water heater/ geyser 25 Ltrs capacity complete with inlet and outlet pipe with all standard fittings and fixing accessories for fixing to wall including making electrical & water line connections and necessary civil work and complying with the following specification:- (i) Type:- Vertical (ii) Capacity of Inner tank:- 25 Ltrs (iii) Colour:- White (iv) Temperature sensitive LED indicator (v) Feather touch digital temp control (vi) Shock proof 3 pin plug. (vii) Upto 8 bar pressure resistance inner tank (viii) Multifunctional safety valve. (ix) IPX4 technology to protect electrical parts from water splash.
(x) Earth leakage current breaker to cut off power immediately in case of current leakage and protect user from electric shocks. (xi) Tank : Made with ultra thick super cold rolled steel plates dry powder coating finish and energy saving high density PUF insulation. (xii) Heating element :- Glass coated heating element with resistant to oxidation and carbonation at high temperature of capacity 2000 W capacity. (xiii) Heavy duty magnesium anode rod with steel core to protect enameled tank from rust and corrosion 230 V, single phase, 50 Hz AC power supply 5 star energy saving rating with BEE level.
Misc Items (TV & Telephone)
Taking down old burnt/ unserviceable light fittings of any description.
Taking down old burnt/ unserviceable ceiling fans, wall fans, exhaust fan of any description/ capacity.
Taking down old burnt/ unserviceable main switches and DBs including MCB SP/ SPN/ TPN of any make and any size, wooden board, junction box of any description/ capacity.
Supply and fix GI metal flush boxes 1/2 module complete all as specified and as directed.
Supply and fix telephone sockets (Jack type) RJ 11-1 with shutter 1 module with cover plate complete all as specified and as directed.
Supply and fix TV co-axial socket 1 module with cover plate complete all as specified and as directed.
Supply and fix Rigid non-metallic PVC conduit of size 25 mm dia inclusive of boxes (junction/ terminal) but inclusive of all te
es, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc concealed in wall or clamped on wall all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_828877.xls
BOQ • 0.39 MB
3_merged.pdf
Tender Documents • 3.60 MB
Download all tender documents and submit your bid