| 1 | L1₹18.6 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.8 L+₹18,982 (1.02%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Rejected due to bidder is not L1 | |
| 3 | L3₹19.3 L+₹59,678 (3.20%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L3 | Rejected-Finance Rejected due to bidder is not L1 | |
| 4 | L4₹19.3 L+₹60,267 (3.23%)Rejected-Finance | L4 | Rejected-Finance Rejected due to bidder is not L1 | |
| 5 | L5₹19.8 L+₹1.2 L (6.39%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L5 | Rejected-Finance Rejected due to bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
22 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh K A Vardhan, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
REPAIR MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY INCLUDING LT DISTRIBUTION SYSTEM ZONE B AT AHMEDABAD CANTT UNDER GE (A) AHMEDABAD
2021_MES_438076_1
8158/E8
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Ahmedabad
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (Army) Ahmedabad
₹44,000
Yes
25 Jun 2021
23 Apr 2021
24 May 2021
23 Apr 2021
22 May 2021
7 May 2021
23 Apr 2021 - 7 May 2021
60 days
Amount
Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete.
Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete.
Steel tubes ISI marked light grade galvanised with all fittings fixed to walls / poles as required of following sizes:-.
40 mm bore
80 mm bore
100 mm bore
Supplying, laying or fixing or passing through pipe, testing and commissioning including suitable size of cable glands/aluminium lugs of 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of following sizes:- Make - Havells / Polycab / Finolex / Universal
10 Sqmm 2 core
10 Sqmm 4 core
16 sqmm 4 core
25 sqmm 4 core
35 Sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supplying and laying factory made un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm laid in trenches over sand for cable protection complete.
M& L for taking out old u/s XLPE cables of following sizes:-
10 sqmm 2 core, 1.1 KV
16 to 35 sqmm 4 core, 1.1 KV
50 to 185 sqmm 3.5 core, 1.1 KV
Taking down old u/s GI protection pipe of sizes 40 to 100 mm bore.
Labour & tools for horizontal boring through road / path / floor for passing UG cables by using trench less technology for laying upto 100mm dia pipe complete all as required. Note : GI / DWC pipe will be measured and paid seperately.
Material and labour for dismanteling old straight through LT Cable joint or finding out of faulty cable including excavation and supply and fixing of new straight through cable joint kit out door type compete with jointing materials (Epoxy joint based) and suitable for following sizes of aluminium conductor complete all as specified and directed by Engr-in-charge. Make : M-seal / Denson
6 to 16 Sqmm 4 Core, 1100 volts
25 to 50 Sqmm 4 Core, 1100 volts
70 to 120 Sqmm 4 Core, 1100 volts
150 to 185 Sqmm 4 Core, 1100 volts
Supplying and fixing in renewal MCCBs with microprocessor release thermally adjustable between 40% to 100%, 100 amp, 3 pole, Icu 35 KA (Ics=50%Icu) with spreader links on both sides as per requirement at site. Make : Havells cat ref no. IHLFENT0100 or equivalent in Standard or C&S as approved.
Supplying and fixing in renewal MCCBs with microprocessor release thermally adjustable between 40% to 100%, 160 amp, 3 pole, Icu 35 KA (Ics=50%Icu) with spreader links on both sides as per equirement at site. Make :Havells cat ref no. IHLFENT0160 or equivalent in Standard or C&S as approved.
Supplying and fixing in renewal MCCBs with microprocessor release thermally adjustable between 40% to 100%, 200 amp, 4 pole, Icu 35 KA (Ics=50%Icu) with spreader links on both sides as per requirement at site. Make : Havells cat ref no. IHLFENF0200 or equivalent in Standard or C&S as approved.
Supplying and fixing in renewal MCCBs with microprocessor release thermally adjustable between 40% to 100%, 250 amp, 4 pole, Icu 35 KA (Ics=50%Icu) with spreader links on both sides as per requirement at site. Make : Havells cat ref no. IHLFENF0250 or equivalent in Standard or C&S as approved.
Supplying and fixing in renewal MCCB 125 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420016 or equivalent in Schneider or Hager as approved.
Supply, errect, test and commissioning LT feeder pillar box out door, made out of CRCA sheet 3mm thickness external and 2mm internal slanting top, from CPRI approved factory fabricated,dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3mm thick MS sheet, seperated chamber will be made for each feeder and bus bar with angle iron legs of size 50x50x6mm and base frame, hinged door, locking arrangement with aluminium bus bar 800Amps capacity,Digital multifunction meter 415V,50 Hz with CTs, indicating lamp neon type with Kit-Kat control fuses for RYB grouted in pillars of PCC 1:3:6 type C1 and powder coat painting with two coats of synthetic enamel paint over one coat of primer comprising the following:- (Drg / design of Panel need to be approved by Engr-in-charge before given order to concern factory )
Incoming:- One number MCCB 250 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz with microprocessor release adjustable between 40% to 100% against overload setting as per Legrand cat ref no. 420319 or equivalent in Schneider or Hager as approved.
Outgoing:- Six numbers MCCB 63 amp, 3 pole, Ics 16 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420003 or equivalent in Schneider or Hager all interconnections of switch gear shall be with suitable size of copper cable/Insulation copper busbar as approved.
Supply, erect, test and commissioning Bus bar feeder pillar box make out of CRCA sheet 3 mm external and 2 mm internal of CPRI approved factory fabricated,dust & vermin proof including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3mm thick MS sheet, with single incommer and outgoing through Bus bar, with angle iron legs of size 50x50x6mm, hinged door, locking arrangement with aluminium bus bar 500Amps capacity,LED indicating lamp for RYB grouted in pillars of PCC 1:3:6 type C1 and painted with powder coat painting coats of synthetic enamel paint over one coat of primer comprising the following:- (Drg / design of Panel need to be approved by Engr-in-charge before given order to concern factory )
Incoming:- One number MCCB 250 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz with microprocessor release adjustable between 40% to 100% against overload setting as per Legrand cat ref no. 420319 or equivalent in Schneider or Hager as approved.
Outgoing:- Four numbers of Alluminium bus bar capacity of 500 Amps for RYB & N with making hole of suitable size for taking cable connection as directed. Bus bar should be fixed in such way cable can be connected easily. Gap between each bus bar should not be less than 150mm all around.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 80 mm & inner pipe dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 1.0 ohm complete. (Note - GI strip size 32x6 mm upto 7.5 m included in the item).
S&F Double wall corrugated (DWC) HDPE pipes of following sizes as per IS : 16098 for protection of under ground cable in trenches crossing under road/path/culvert complete all as directed :-Make : Supreme / Rex Polyextrusions / Alom Polyextrusions.
75mm bore
100mm bore
Intelligent Power Factor Controller, 144 mm x 144 mm flush mounted all as per Havells cat ref no. QHOTRB5N0006 IPFC 11003 6+1Step Relay 3Ø, 3 x 230 V, (L-N), 50 Hz or equivalent in L&T or Conzerv as approved.
Capacitor 415 V, AC 3Ø, 5 KVAR as per Havells cat ref no QHSTMB5005X0 Champion 415V 50Hz-5KVAR 3PH or equivalent in L&T or Siemens as approved.
Capacitor 415 V, AC 3Ø, 10 KVAR as per Havells cat ref no QHSTMB5010X0 Champion 415V 50Hz-10KVAR 3PH or equivalent in L&T or Siemens as approved.
Capacitor 415 V, AC 3Ø, 25 KVAR as per Havells cat ref no QHSTMB5025X0 Champion 415V 50Hz-25KVAR 3PH or equivalent in L&T or Siemens as approved.
MCB four pole 40 to 63 amps, 10 KA, 'C' series ISI marked. Make - Legrand DX3/ Schneider/Hager as approved.
Contactor suitable for 25 KVAR,415 V 3 Phase
Contactor suitable for 15 KVAR ,415 V 3 Phase
Contactor suitable for 5 to 10 KVAR ,415 V 3 Phase
S&F replacement of High break HBC fuse link125 Amps to 315 Amps,80kA,50Hz, Make:HPL,LKDN-II(Size-02)
S&F replacement of High break HBC fuse link 400Amps to 425 Amps,80kA,50Hz. Make:HPL,LKDN-III(Size-03)
S&F replacement of MCB Four pole 40 to 63 amp,10kA 415A . Make - Legrand/ Hager / Schneider
Material and labour for servicing, repairing and welding to out door LT Panel / LT Feeder Piller box by (i) Cleaning with blower, (ii) Cleaning with CTC/Petrol (iii) Replacement of damaged copper/aluminium lugs (iv) Replacement of deteriorated copper wiring with existing sizes of cable (v) Cleaning and tightening of MCCB terminals (vi) Replacement and fixing of sheared rubber beadings (vii) Rectifying of loose connections of incoming and outgoing cables (viii) Painting two coat of smoke gray colour over one coat of primer and black paint on base channel after rubing with emery paper and making smooth finishes (ix) Providing of door locking arrangement with of sliding bolts on panel door (x) Proper welding of Panel door/roof as required (xi) Connecting / cleaning of earth wire /earth strip (x) Two coat of white distemper on foundation complete all as directed.
S&F Digital AC voltmeter, 4 digit, 7 segment LED display, square type, input voltage 50 -480VAC including dismantling of unserviceable voltmeter and connecting the cable as per requirement on existing panel Make : Selec or equivalent.
S&F Digital AC Ammeter 4 digit, 7 segment LED display, square type input voltage 50 -480VAC including dismantling of unserviceable ammeter and connecting the cable as per requirement on existing panel. Make : Selec or equivalent.
S&F daylight viewable panel mount indication LED R/Y/B with base including dismantling of unserviceable indication lamp on existing panel and connecting up the cables complete.
Shree Karni Construction
Abhishek Enterprises
Maharaja Infrastructure
Electricals India
TECH SERVE SOLUTIONS
ambika electric co
mahavir industries
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .