| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.3 L+₹29,130.20 (1.00%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹30.0 L+₹98,610.10 (3.40%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
2 Oct 2024, 6:00 pmClosed
Major S N Gaikwad
Holta Cantt Palampur
SPL REPAIR TO LEAKAGE AND SEEPAGE IN SUNKEN FLOOR AND SANITARY FITTING IN BLDG NO P-53 AND P-54 AT PALAMPUR MIL STN AND SPL REPAIR TO 02 X BATHROOMS AND TOILET A 20A AND A 20B AT ALHILAL MIL STN
2024_MES_671111_1
GEP-32/2024-25
Open Tender
Civil Works
Item Rate
180 days
Palampur and Alhilal Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹77,000
14 Nov 2024
3 Sept 2024
4 Oct 2024
3 Sept 2024
2 Oct 2024
18 Sept 2024
Amount
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
M&L Non-skid, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles including 25mm thick, plain cement concrete, 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in sub base of floor / path surfaces finished even & rough to receive floor finishes, complete all as specified and directed. complete all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surface 350mm x 250mm x 7mm/450mm x 350mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting/dado etc. laid over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured to match the tiles including dismantling complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed.
M&L brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Taking down cement plaster including tiles of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
Rendering 15mm thick plaster on fair faces of brick work/stone masonry, concrete surface in CM 1:6, finished the surface even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick plaster on fair faces of brick work/stone masonry, concrete surface in CM 1:4, finished the surface even and smooth without using extra cement complete all as specified and directed.
Rendering 5mm thick plaster on fair faces of concrete surfaces as in facia or ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed.
S&F wire netting (12x12mm) of galvanised steel wire 0.91mm dia fixed with tinned tacks of wire staples complete all as specified and directed.
M&L preparation of newly plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion and applying plaster of paris putty of 2mm thick over newly plastered wall surfaces including preparation of surface even and smooth complete all as specified and directed.
M&L preparation of newly plastered/unplastered wall surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of cement base paint upto 15m height, complete all as specified and directed.
M&L preparation of new plastered ceiling surface and applying three coats of white wash, complete all as specified and directed.
M&L preparation of old plastered ceiling surface and applying three coats of white wash, complete all as specified and directed.
M&L preparation of old plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion and applying plaster of paris putty of 2mm thick over plastered wall surfaces including preparation of surface even and smooth complete all as specified and directed.
Prepartion of old wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed.
M&L PCC 1:4:8 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, filling under sunken complete all as specified and directed.
M&L preparation of old surfaces of steel of any description, over 10 cm width or girth not other wise described and appliying two coats of synthetic enamel paint over existing surface complete all as specified and directed.
M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished and moulding of outer edges) in steps, jambs and pillars, window cills, cooking platforms and the like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with and including 15mm thick screed bed in CM 1:4, complete all as specified and directed.
M&L RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span incl demolition complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Form work to rough finished surfaces of concrete for soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat or curved complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.50 sqm but n.exc. 4 sqm each complete all as specified and directed.
S&F, solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, supplying and fixing in opening as per specifications & directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat molded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified & directed.
S&F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S&F 150 mm size (length of bolt) aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F in repair vitreous china coloured wash down water closet pan (Padestal Pattern), including connection to flush pipe, 'P' or 'S' trap, with fixing bolts PVC seat cover with chromium plated mild steel hinges device (excluding flushing cistern and flush pipe), complete all as specified and directed.
S&F in repairs vitreous china squatting pan 'Orissa' pattern of size 580x440mm white with integral foot rest with 'P' or 'S' trap any type suitable to connect to outlet including provision of lime concrete, making connection to trap and to flush pipe etc. complete all as specified and directed. Note: These rates include the following:- (i) Complete removal of existing treatment of sunken floor. (ii) Provn of lime concrete.
M&L 10 litres capacity PVC, low level, valveless, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement, 32mm dia PVC flushing pipe and 15mm dia, 450mm long PVC connection with CP brass coupling nuts and PVC washer at both ends (fixed in repair), complete all as specified and directed.
S&F jet for pedestal pan, chromium plated with flexible pipe of 90cm in length (fixed in repair) complete all as specified and directed.
S&F in repairs PVC connection 15mm size, 450 mm long with PTMT nuts complete all as specified and directed.
S&F in repairs vitreous China wash basin, white, oval type, size 580 x 450mm including union, brackets and incl waste pipe, chain and plug and porcelain stopper complete all as specified and directed.
S&F in repairs, fancy type, pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' & 'Cold' with long screwed shanks and fly nuts, screwed for 15 mm bore iron pipe complete all as specified & directed.
S&F in repair vitreous china half staff urinal flat back, size 465x355x265mm white (minimum), including grating and union for discharge pipe excluding flushing cistern, flush pipe and waste pipe, complete including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement fixing, flush pipe grating and ujnion for discharge pipe, incl urinal spreader complete all as specified and directed.
S&F in repairs stop cock, fancy type, chromium plated, with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15 mm bore iron pipe or for union complete all as specified & directed.
S&F 15mm bore stop valves/angle cock (two way), cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, fixed in repair, complete all as specified and directed.
S&F in repairs, fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed.
S&F in repair brass chromium plated shower rose 125mm size, with or without swivel joints, including shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour, fixing to steel pipe or union complete all as specified and directed.
S&F in repairs soap dish vitreous china white,approximate size 160mm x 160mm x 90mm fixed to plugs with chromium plated brass screws complete all as specified and directed.
Disconnecting existing tanks of capacity exc. 500 but n. exc. 1000 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scale and dirt,etc,from tanks and from moulds of circulating pipe,etc complete all as specified and directed.
S&F in repairs 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including fixing fittings such as GI nipple for inlet, outlet, washout and overflow etc, including 20mm size ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling complete all as specified and directed.
Fixing only old steel water tubing obtained from taking down, 15mm bore, galvanised, "medium grade" with all new fittings, fixed to wall and ceiling or laid in floor including taking down, complete all as specifed and directed.
Fixing only old steel water tubing obtained from taking down, 25mm bore, galvanised, "medium grade" with all new fittings, fixed to wall and ceiling or laid in floor including taking down, complete all as specifed and directed.
S&F steel water tubing, 15 mm bore, galvanised , "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including taking down, complete all as specified and directed.
S&F steel water tubing, 25 mm bore, galvanised , "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including taking down, complete all as specified and directed.
Dismantling CI/PVC pipe 100-110mm bore fixed to wall or laid in floor or trenches including connecting complete all as specified and directed.
Dismantling CI/PVC pipe 75/50mm bore fixed to wall or laid in floor or trenches including connecting complete all as specified and directed.
S&F cast iron soil waste spun pipe 100mm bore single socketed, in any length with cement joint, fixed in wall including fixing 5mm flat iron and 16mm dia iron stay clamps etc complete all as specified and directed.
S&F cast spun pipe 100mm bore single socketed, in any length with rubber ring joints, as in floor and trenches complete all as specified and directed.
S&F cast spun pipe 50mm bore single socketed, in any length with rubber ring joints, as in floor and trenches complete all as specified and directed.
S&F cast spun pipe 75mm bore single socketed, in any length with rubber ring joints, as in floor and trenches complete all as specified and directed.
S&F cast iron spun waste pipe 75mm bore single socketed, in any length with cement joints, fixed in wall including fixing 5mm flat iron and 16mm dia iron stay clamps etc complete all as specified and directed.
S&F 75mm bore of pipe cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access doors, complete all as specified and directed.
S&F 100mm bore of pipe cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access doors, complete all as specified and directed.
M&L 75 mm size cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 complete including taking down old unserviceable floor trap complete all as specified & directed.
S&F 100mm bore branch pieces, (double T) equal or unequal with oval access door ,complete all as specified and directed.
S&F 75mm bore branch pieces, (double T) equal or unequal with oval access door ,complete all as specified and directed.
S&F cast iron vent cowl 50mm bore dia, complete all as specified and directed.
M&L 50mm thick PCC 1:2:4 in two layers type B-0 (using 12.50mm thick crushed stone aggregate) as in sub base of floors, pavings & roof padding etc including chicken wire mess (12x12mm) of galvanised steel wire 0.91mm dia (sandwich) complete all as specified.
M&L 10mm thick (average) screed bed/plaster in cement mortar 1:3 in order to maintain proper slope and base over existing roof surface for laying of APP based polymeric membrane, mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. (Note:- WPC and polymeric memebrane shall be measured and paid separately)
S&F High performance two component brushable elastomeric poly urea waterproofing coating cold applied brush applied ultraseal BA or approved equivalent (in sunken portion of WC & floor trap) liquid membrane with white in colour with a elongination of 500% and tensile strength of 5 N/sq mm @ DFT 1mm as per ASTM D 2370.73 % solid content, shore A hardness of min 70. The system include final base preparation, epoxy primer application @200-250 gms/sqmt depending upon the surface porosity and applying home shild ultraseal BA or approved equivalent in two coats at 1.5 kg sqm providing 1.2 mm DFT etc, complete as per manufacture specification.
M&L 15mm thick (average) screed bed/plaster in cement mortar 1:3 in order to maintain proper slope and base in sunken portion of WC & floor trap for surface applying water proofing treatment coating mixed with water proofing compound as per manufacturer's instructions finished even and smooth without using extra cement complete all as specified and directed. (Note:- WPC and polymeric memebrane shall be measured and paid separately)
Supply only liquid water proofing compound complete all as specified and directed.
M&L 50mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection/footpath finished even and smooth without using extra cement complete all as specified and directed.
Rendering 10mm thick plaster on fair faces of brick work/stone masonry, concrete surface in CM 1:6, finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L preparing new plastered surface of walls/concrete surfaces and applying three coats of white wash complete all as specified and directed.
M&L preparation of newly plastered or unplastered surfaces of walls priming plastered and other surfaces with alkali-resistant priming paint and applying two coats of cement base paint white or tinted complete all as specified and directed.
M&L preparation of old surface of walls and applying two coats of white wash complete all as specified and directed.
M&L preparation of old plastered or unplastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L preparation of old plastered ceiling surface and applying two coats of white wash, complete all as specified and directed.
S&F pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and tarring back side of frame, complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-0 using 12.50 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed.
S&F 35mm thick factory made 2nd class hard wood rail and style plain framed, panelled shutter with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 (part 1) kiln seasoned and chemically pressure treated complete all as specified and directed.
Prepartion of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares n.exc. 0.50 sq.m in each pane, complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars dove tailed or welded complete` all as specified and directed.
S&F 150 mm size extruded aluminium handles, cast type, anodised complete all as specified and directed.
S&F 200 mm size (length of bolt) aluminium alloy, anodised, sliding door bolt with hasp and staple ,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L Non-skid, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles including 25mm thick, plain cement concrete, 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as levelling course and etc laid over and 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed. complete all as specified and directed.
Dismantling 75/100mm dia cast/PVC drain pipe, jointed in cement mortar fixed in trenches and taking out of trenches removing where directed complete all as specified and directedd.
S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints fixed to walls/ laid in trenches or in floors, complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints fixed to walls/ laid in trenches or in floors, complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends complete all as specified and directed.
S&F 75mm bore PVC (SWR) junction, (single T) equal or unequal with oval access door ,complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction, (double T) equal or unequal with oval access door ,complete all as specified and directed.
S&F 75mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore dia, complete all as specified and directed.
S&F vitreous china squatting pan 'Orissa' pattern of size 580x440mm white with integral foot rest with 'P' or 'S' trap any type suitable to connect to outlet including provision of lime concrete, making connection to trap and to flush pipe etc. complete all as specified and directed. Note: These rates include the following:- (i) Complete removal of existing treatment of sunken floor. (ii) Provn of lime concrete.
S&F vitreous china wash down Europian water closet pan (Padestal Pattern), including connection to flush pipe, 'P' or 'S' trap, with fixing bolts PVC seat cover with chromium plated mild steel hinges device and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 complete all as specified and directed.
S&F 10 litres capacity PVC valve less symphonic action type flushing cistern (ISI Marked) low level with inlet ball valve, float and handle including brackets & 32 mm size PVC flush pipe, complete all as specified and directed.
S&F health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete al as specified and directed.
S&F PVC connection 15mm size 600 mm long with PTMT nuts complete all as specified and directed.
S&F Vitreous china, wash hand basin, (white) of size 550mm x 400mm including brass CP waste coupling 32mm size with long screwed shank and fly nuts, PVC medium grade 32mm dia waste pipe, chain and plug, porcelain stopper , PVC connection 15mm dia, 450mm long with brass CP nuts and washers at both ends (fixed in repair), complete all as specified and directed.
S&F in repairs aluminium anodised tubular towel rail, 20mm dia, D type 60cm long , fixed to wall with CP brass screw and PVC rawl plugs, complete all as specified and directed.
S&F in repair 15mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for GI tubing complete all as specified and directed.
S&F brass chromium plated shower rose 125mm size, with or without swivel joints, including shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour, fixing to steel pipe or union complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection, including cleaning for refixing or removal from site, complete all as specifed and directed.
Taking up or down 20mm bore steel tubing and connection, including cleaning for refixing or removal from site complete all as specified and directed.
Taking up or down 25mm bore steel tubing and connection, including cleaning for refixing or removal from site complete all as specified and directed.
S&F steel water tubing, 15 mm bore, galvanised , "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
S&F steel water tubing, 20 mm bore, galvanised , "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
S&F steel water tubing, 25 mm bore, galvanised , "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Cutting chase, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing,steps, cills, sunshades, shelves,lintels,etc and cutting chase for concealed water tubing or concealed conduit wiring etc and making good, cutting exc. 10cm but not exc 20cm girth complete all as specified and directed.
M&L 30cm x 30 cm x 25mm thick, coloured rubber moulded chequered cement concrete tiles with grey cement and pigment set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
M&L preparing the surface of roof slab by brushing with wire brashes for removal of loose materials etc and sweeping with brooms, gunny bags and finally remove dust by compressed air by compressor complete, complete all as specified and directed.
M&L applying neat cement slurry with 3Kg of cement slurry per sq.m mixed with liquid water proofing compound on surfaces of roof and platering 10 mm thick in cement mortar 1:3 mixed with liquid water proofing compound as per manufacturer's instructions and finishing the surface even and smooth without using extra cement, complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L one coat of cold bituminous primer to the plastered surface @ 0.40 litres per sqm conforming IS-3384 and laid a layer of APP polymeric membrane 3mm thick (minimum) weighing 3.0 kg per sqm reinforced with polyster non woven fabric (weight not lass than 150gm/sqm) by toarch application method complete all as per manufacturer instructions and sealing all the over lap shall be minimum 75mm in length side and 100mm on with side complete all as specified and as directed.
M&L 40mm thick plain cement concrete, M-15 (Nominal Mix), type B-0, 1:2:4 (using 12.5mm graded crushed stone aggregates) as in roof kerbs, mud stops, roof padding over APP etc using water proofing compound, complete all as specified and directed. Note: WPC shall be measured and paid seperately.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:6, complete all as specified and directed.
M&L plain cement concrete M-10 type C-1 (using 20mm graded crushed stone aggregates) as in surface channels or drains etc, complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.(inner girth only measured)
Boring holes through glazed tile lining for pipes, etc. not exc 50mm dia and making good complete all as specified and directed.
Taking down carefully existing aluminium / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
Taking down sub main wiring of any size and type and in any position metalic/non metalic PVC conduit of wooden batten complete all as specified and directed.
Taking down unsv sheet metal box & MCB DB SPN with MCB's of any make/capacity complete all as specified and directed.
M&L concealed point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694: 2010 having multi stranded copper conductor 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No.) drawn in and including concealed non metallic rigid PVC conduit medium area (ISI marked with valid CML No) grade (ISI marked with valid CML No) not less than 20 mm dia confirming to IS 14930 (Part-I) 2001, with all fitting and fixing accessories and 1.5 sqmm FRLSH PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes factory made for mounting switch, regulators etc eith and including 3 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosice paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete fo the following:-
One light point controlled by one switch
One Exhaust fan point controlled by one switch
One 5 pin multipurpose socket outlet 5/6 amps on the same board with other switch.
3 pin socket outlet 5 amps independent board.
All as item No 121 here in before but point wiring with 2.5 sqmm FRLSH confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire
S&F switch piano, flush button single pole one way 5/6 Amp complete ass as specified and directed
S&F socket outlet, multipurpose, 2 in 1 5 pin, 5 Amp complete all as specified and directed
S&F switch piano, flush button single pole one way 15/16 Amp complete as specified and directed.
S& F socket outlet multipurpose flush type, 2 in 1 6 Pin 5/15 amps complete all as specified and directed.
S& F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
S&F Lamp holder with metal ring, PVC/ Polycarbonate type with back plate suitable for batten fittings non ISI Marked complete all as specified and directed.
S&F LED Bulb 09/10 watt with provision of fixed in lamp holder complete all as specified and directed.
S&F LED 'T' type mirror light fitting 09/10 watt with provision of fixed in lamp hpolder complete all as specified and directed.
S&F decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviromental friendly energy efficient ready to use, 20 watt, 6500K fitting, including reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core coppor conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S& F security light fitting better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 X 5 mm FI, 15 cm long, 8 mm dia bolts and nuts with washer grouted in wall complete including reqd lingth of 1.5sqmm PVC multistranded BIS marded, 03 cpre copper conductor for connection rom ceiling rose to lilght fittings incl testing on completion all as specified and directed.
M&L sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multistranded copper conductor (ISI marked with valid CML No) cable 1100 volt grade, 6 sqmm size draw in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia confirming to IS 14930 (Part-I) 2001,with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 sqmm FRLSH copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. Note: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillers/columns etc. of any discription for concealing the conduits to required deapth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
S&F 300mm sweep exhaust fan made of sturdy Engineering steel body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding, 5 star rated complete all as specified and directed.
S&F water heater storage type metallic outer body and stainless steel inner container, 50 ltr capacity, electric suitable for single phase, 50 Hz, AC supply, 5 star rating, including all necessary fittings and fixture with minimum 1M of three core 2.5 Sqmm twisted copper conductor cable PVC insulated, three pin plug top complete with necessary fittings and fixtures complete all as specified and directed.
S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket with and including one single pole MCB 20 amps, 240 volts, 10 KA complete all as specified and directed.
S&F MCB, DB sheet metal enclosure, double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (metal door) type with blanking plates where reqd, flushed in wall and making good disturbed surfaces & IP-43 degree protection complete all as specified and directed.
S&F MCB SPN 63 amps, 240 volts 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed.
S&F MCB SP 240 volts 6 to 32 amps, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 10 sqmm 2 core including taking out old unserviceable cable complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 16 sqmm 2 core including taking out old unserviceable cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
M&L old size brick class "B" as in cable protection laid dry,flat,transversally along the length of cable on sand cushioning with width equal to length of the brick complete all as specified and as directed.
S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
Taking up or down old GI tubing 15mm bore and connections (inlcuding fittings) from trenches/walls/floors and connections including cleaning for re-fixing or remove to store yard/credited to contractor completed all as specified and directed.
S&F fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed.
S&F PVC connection 15mm dia, 60cm long with 02 Nos of unions and washers with steel reinforcement material suitable for hot water supply complete all as specified and directed.
Cutting and screwing existing GI tubing of 15mm for alterations or additions on pipe for connectors (each cut measured) complete all as specified and directed.
S&F single pole and neutral enclosure with 1 two pin and earth plug and a socket complete with one single pole C type MCB, 20 Amp, 240 volts ISI marked complete all as specified and directed.
M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 6.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note:-1. Wiring shall be done in proper colour coding. 2. Cutting chases on the wall wherever required is deemed to be included in unit rate quoted.
Disconnecting water heater and taking in safe custody/refixing the same and making the connection and testing complete all as specified.
Disconnecting/taking down exhaust fan of any sweep removing and cleaning the dust properly, painting with same colour good quality synthetic enamelled paint after preparing surface for painting with existing colour shade oiling and greasing of bearing including refixing and making the connection and testing complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connecting to GI earth wire of size 4mm size by means of bolts, nuts, check nuts and protected by provision of GI medium grade pipe of 15mm bore including provision of 40mm tk cover of RCC (1:2:4) reinforced with XPM (wt no less than 4Kg/sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm dia pipe for watering of suitable length placed on tp edge of earth plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and excavation and earthwork in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as per plate No. 3 of SSR 2009 Part-I and connecting to earth test point all as specified and directed by Engineer-in-Charge and including testing on completion.
VIVEKA ENTERPRISES (BID ID -3112941)
BHARDWAJ BUILDERS (BID ID -3112317)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .