Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC MAIN ROAD BEALUNJI P O WAIDHAN DISTT SINGRAULI M P | SINGRAULI | MADHYA PRADESH | ₹2.3 Cr Quoted ₹2.0 Cr | L1 | Accepted-AOC Awarded being L1 bidder and duly approved. |
| 2 | L2₹2.0 Cr+₹3.4 L (1.72%)Rejected-Finance QTR NO 1B 43 STAFF COLONY PO JAMUNA COLLIERY DISTT ANUPPUR M P 484444 | ANUPPUR | MADHYA PRADESH | 484444 | ₹2.0 Cr+₹3.4 L (1.72%) | L2 | Rejected-Finance Rejected being not L1 bidder and duly approved. |
| 3 | L3₹2.0 Cr+₹7.6 L (3.91%)Rejected-Finance B 50 WARD NO 02 S S GREEN KORBA TOWN KORBA PIN CODE 495677 | KORBA | KORBA | CHHATTISGARH | 495677 | ₹2.0 Cr+₹7.6 L (3.91%) | L3 | Rejected-Finance Rejected being not L1 bidder and duly approved. |
| 4 | L4₹2.8 Cr+₹81.5 L (41.8%)Rejected-Finance | ₹2.8 Cr+₹81.5 L (41.8%) | L4 | Rejected-Finance Rejected being not L1 bidder and duly approved. |
| 5 | L5₹3.3 Cr+₹1.3 Cr (68.0%)Rejected-Finance DAKRA RANCHI PIN 829201 | CHATRA | JHARKHAND | 829201 | ₹3.3 Cr+₹1.3 Cr (68.0%) | L5 | Rejected-Finance Rejected being not L1 bidder and duly approved. |
| Sl No | Description | Qty | Unit | bsreddy L2 | M/S. SHIV SHANKAR ELECTRICAL CIVIL ENGINEERING L1 | Jai Enterprises L5 | UDAY CONSTRUCTION L4 | VRE-NKS JV L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group A | 400 | Point | 525 ₹2,10,000 | 441 ₹1,76,400 | 1,550 ₹6,20,000 | 250 ₹1,00,000 Lowest | 450 ₹1,80,000 |
| 2.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group B | 400 | Point | 555 ₹2,22,000 | 540 ₹2,16,000 | 1,600 ₹6,40,000 | 250 ₹1,00,000 Lowest | 550 ₹2,20,000 |
| 3.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group C | 300 | Point | 660 ₹1,98,000 | 720 ₹2,16,000 | 2,000 ₹6,00,000 | 250 ₹75,000 Lowest | 650 ₹1,95,000 |
| 4.00 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | 50 | Point | 666 ₹33,300 | 800 ₹40,000 | 2,200 ₹1,10,000 | 350 ₹17,500 Lowest | 650 ₹32,500 |
| 5.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A | 50 | Point | 535 ₹26,750 | 900 ₹45,000 | 2,200 ₹1,10,000 | 350 ₹17,500 Lowest | 500 ₹25,000 |
| 6.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B | 50 | Point | 585 ₹29,250 | 400 ₹20,000 | 1,400 ₹70,000 | 350 ₹17,500 Lowest | 550 ₹27,500 |
| 7.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | 50 | Point | 640 ₹32,000 | 400 ₹20,000 | 1,600 ₹80,000 | 350 ₹17,500 Lowest | 700 ₹35,000 |
| 8.00 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 350 | Metre | 190 ₹66,500 | 151 ₹52,850 | 2,000 ₹7,00,000 | 90 ₹31,500 Lowest | 180 ₹63,000 |
| 9.00 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 400 | Metre | 325 ₹1,30,000 | 200 ₹80,000 | 800 ₹3,20,000 | 130 ₹52,000 Lowest | 250 ₹1,00,000 |
| 10.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 2,500 | Metre | 120 ₹3,00,000 | 80 ₹2,00,000 | 400 ₹10,00,000 | 60 ₹1,50,000 Lowest | 121 ₹3,02,500 |
Tender Value
₹4.1 Cr
EMD Value
₹5.1 L
Closing Date
4 Mar 2026, 5:00 pmClosed
General Manager (Civil)/HOD,SECL
Office of GM (Civil)/HoD, SECL Bhawan, Seepat Road, Bilaspur, CG, PIN-495006. Contact No.9425596917/email- gmcivilhod.secl(at)gmail.com and/or gmcivil.secl (at)coalindia.in
AMC for Repair and Maintenance work (Electrical) of Administrative Buildings of SECL HQ Bilaspur (for 02 years).
2026_SECL_353091_1
GM(C)/ SECL/ BSP/ e-T/ TA-AMC /2025-26 /30 Dated 13.02.2026
Open Tender
AMC WORKS
Item Rate
730 days
Administrative Building, SECL HQ
As per NIT
6 documents required · 6 mandatory
₹5.1 L
5 Aug 2026
14 Feb 2026
6 Mar 2026
14 Feb 2026
4 Mar 2026
15 Feb 2026
14 Feb 2026 - 25 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group A | 400 | Point | - | - |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group B | 400 | Point | - | - |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group C | 300 | Point | - | - |
| 4 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | 50 | Point | - | - |
| 5 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A | 50 | Point | - | - |
| 6 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B | 50 | Point | - | - |
| 7 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | 50 | Point | - | - |
| 8 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 350 | Metre | - | - |
| 9 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 400 | Metre | - | - |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 2,500 | Metre | - | - |
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.97 MB
Tendernotice_2.pdf
PDF • 1.49 MB
Tendernotice_3.pdf
PDF • 0.26 MB
BOQ_365891.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .