Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC CHILIYANAULA RANIKHET DISTT ALMORA UTTARAKHAND | ₹4.1 Cr Quoted ₹4.2 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹4.5 Cr+₹36.1 L (8.63%)Rejected-Finance 160 PREM NAGAR BAREILLY | ₹4.5 Cr+₹36.1 L (8.63%) | L2 | Rejected-Finance Being other than L1 |
| 3 | Rejected-Technical HOUSE NO 04 NEW SARASWATI VIHAR NEAR PAWAN VIHAR PHASE 6 OVER HEAD TANK BAREILLY 243006 UP | BAREILLY | BAREILLY | UP | 243006 | - | - | Rejected-Technical Due to three class below eligible class |
Tender Value
₹4.8 Cr
EMD Value
₹5.6 L
Closing Date
19 Jan 2022, 6:00 pmClosed
Chief Engineer Bareilly Zone Bareilly
Chief Engineer Bareilly Zone, Military Engineer Services, Sarvatra Bhawan, Station Road Bareilly Cantt, Bareilly 243 001
ADDITION ALTERATION CUM SPECIAL REPAIR TO CERTAIN JCOs ORs Md ACCN AT RANIKHET CHAUBATTIA ALMORA NAINITAL GHINGARIKHAL UNDER GE RANIKHET
2021_MES_491244_1
CEB/PGH/T-18 OF 2021-2022
Open Tender
Civil Works
Item Rate
547 days
Ranikhet almorah ghingarikhal nainital
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE Ranikhet
₹5.6 L
18 Feb 2022
29 Nov 2021
24 Jan 2022
30 Nov 2021
19 Jan 2022
1 Jan 2022
30 Nov 2021 - 14 Dec 2021
Amount
S & F in repairs vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including provision of lime concrete bedding, connection to trap and to flushing pipe, anti syphonage pipe etc and making good to disturbed floor as per existing including removing of debris from site (At a place as directed), complete all as specified and as directed.
S&F in repairs 100mm dia PVC (SWR) 'P' or 'S' trap with long arm, complete all as specified and directed
S&F in repairs brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed.
Supply & fixing rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates of etc. confirming to Fe-290 (Gde-E-165), complete all as specified and directed.
Supply & fixing rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates of etc. confirming to Fe-410-W (Gde-E-250) Quality-A, complete all as specified and directed.
M&L for rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings of Fe 410 –W (Gde- E- 250), quality-A, heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., complete all as specified and directed.
S&F in repairs 40mm bore dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed
M&L for coloured / printed non-skid, joint free ceramic tiles, 7 to 8 mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bedding in CM 1:6 and pointed in white or coloured cement to match including dismantling of existing floor hearth and removing serviceable tiles to MES store & rubbish / debris are to be disposed off at place as directed by Engr-in-Charge, complete all as specified and directed.
M&L for coloured / printed non-skid, joint free ceramic tiles, 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bedding in CM 1:6 and pointed in white or coloured cement to match including dismantling of existing floor hearth and removing serviceable tiles to MES store & rubbish / debris are to be disposed off at place as directed by Engr-in-Charge, complete all as specified and directed.
All as per item no.09 but as in skirting / dado, laid over and including 10mm thick rendering in cement mortar 1:4 including dismantling of existing wall hearth, complete all as specified and directed.
M&L for coloured / printed non-skid, joint free ceramic tiles, 7 to 8 mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bedding in CM 1:6 and pointed in white or coloured cement to match including dismantling of existing floor hearth and removing serviceable tiles to MES store & rubbish / debris are to be disposed off at place as directed by Engr-in-Charge, complete all as specified and directed.
M&L for colour glazed ceramic tiles as on vertical surface of size 450X 300X 6-7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10mm thick rendering in cement mortar 1:4, including dismantling of existing wall hearth and removing serviceable tiles to MES store & rubbish / debris are to be disposed off at place as directed by Engr-in-Charge, complete all as specified and directed.
S&F in repairs 75mm dia, cast iron spun soil waste and vent pipe, in any length with or without ears, with cement joints, fixed to wall or floors, complete all as specified and directed.
S&F in repairs 100mm dia, cast iron spun soil waste and vent pipe, in any length with or without ears, with cement joints, fixed to wall or floors, complete all as specified and directed.
S&F in repairs bends (any radius) 100mm bore cast iron plain bends (Larger bore measured, complete all as specified & directed.
S&F in repairs 100mm bore cast iron cowls, complete all as specified & directed.
S&F in repairs 75mm bore cast iron cowls, complete all as specified & directed.
S&F 32mm dia high density polyethylene (HDPE) waste pipe of suitable length, complete all as specified and directed
S&F stainless steel wall mounted plate rack of size 780x760x240mm, made from the stainless steel sheet having thickness 1 mm and weight not less than 7.50 Kg, design & pattern as approved by GE, having sufficient space for placing crockeries, fixed on wall with rawl plug & screws, complete all as specified and directed
Demolition of cement concrete in ground floor and pavings n. exc. 15 cm thickness (below or above GL) and removing the rubbish / debris to a distance as directed by Engr-in-charge, complete all as specified and directed.
Demolition of stone slab & tiles of any description or thickness in floor, aprons etc., laid dry and pointed in any mortar and removing the rubbish / debris to a distance as directed by Engr-in-charge, complete all as specified and directed.
Dismantling timber scantlings, 40 Sqcm over in section in any position, fixed with nails unframed work, complete all as specified and directed.
M&L for 2nd class hard wood (Sal), clean sawn as in timber framed work of floor / roof truss or purlins etc., complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Demolition of brick work or stone / boulder or PCC block masonary, built in cement mortar including all quoins, arches, pillars etc., complete all as specified and directed.
M&L for precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:6 using PCC 1:3:6 type C-1 precast cement concrete blocks, complete all as specified and directed.
M&L for brick work with subclass 'B' bricks (old size), straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4, complete all as specified and directed.
Supply only integral water proofing compound, complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in bends, kerbs, string courses, coping, holdfasts including weathering and throating including necessary form work etc., complete all as specified and directed.
M&L for IInd class hard wood (Sal) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for re-fixing and stacking at a place as directed at site, complete all as specified and as directed for the following sizes:- (a) 15 mm dia bore
(b). 20mm dia bore.
(c). 40mm dia bore.
Refixing old serviceable steel tubing and connection in new or old position (Wall, ceiling floor etc.) including necessary fittings & fixtures etc. complete all as specified and directed for following size of pipe :- Note :- Serviceable pipe, obtained from serial item nos. 32 to 32.2 shall be re-used under this item. (a) 15 mm dia bore
(b). 20mm dia bore.
(c). 40mm dia bore.
S&F, jointing and testing galvanised steel tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floor complete all as specified and as directed for the following sizes:- (a) 15 mm dia bore
(b). 20mm dia bore.
(c). 40mm dia bore.
Cutting chases, pinning in, concrete block walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing and making good, cutting n. exc. 10 cm girth, complete all as specified and directed.
S & F in repairs 15 mm bore bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S & F in repairs 15 mm bore chromium plated, fancy type stop valve cast copper alloy, screwed down high pressure without or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S & F in repairs 15 mm bore chromium plated, fancy type angle valve cast copper alloy, screwed down high pressure without or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S & F in repairs 15 mm bore stop valve cast copper alloy, fancy type, chromium plated with long shank and cup (Concealed type), screwed down high pressure without or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S&F in repairs 150mm internal dia of pipe salt glazed stoneware drain pipes, laid in trenches and jointed in cement & sand mortar 1:1, complete all as specified and directed.
M&L for concrete bed 1:4:8 type D-2 as in drain pipes including packing under, and haunching against the side of pipes after they are laid and tested, 150mm bore of pipe, complete all as specified and directed.
S&F soap dish, chromium plated steel / stainless steel of size 160x160x1mm thick, fixed to wall with plug & CP brass screws, complete all as specified and directed.
S&F in repairs vitreous china wash basin white flat back, size 550x400 mm, including fixing pillar tap & PVC connection, with & including new angle iron brackets of suitable size & length, 32 mm dia PVC waste pipe, 32mm dia brass chromium plated waste coupling , complete all as specified and directed. Note :- Pillar tap & PVC connection shall be measured & paid separately as supply only under respective items of BOQ
Supply only pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, swan neck, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for 15mm bore GI pipe, complete all as specified and directed.
Supply only 15 mm bore PVC connection 450 mm long with PTMT nut and PVC washer, complete all as specified and directed.
S&F 15 mm bore PVC connection, 600 mm long with PTMT nut and PVC washer, complete all as specified and directed.
Taking down vitreous china wash basin including PVC connection, waste coupling, waste pipe & pillar tap of any type and size and re-fixing the same in same location / position, complete all as specified and directed.
Disconneting existing tank of capacity exceeding 250 and not exceeding 500 litrs, setting aside (or lowering if required) for repair, cleaning etc and hoisting if required, reconnecting and refixing in position etc, complete all as specified and directed.
S&F in repairs 500 litre capacity of rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), confirming to IS-12701 (1996), three layered construction hoisted and fixed in position including making all connections complete all as specified and as directed.
S&F in repairs 1000 litre capacity of rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), confirming to IS-12701 (1996), three layered construction hoisted and fixed in position including making all connections complete all as specified and as directed.
S&F in repairs 20mm size brass ball valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
S&F in repairs 10 litres capacity, PVC flushing cistern, low level including PVC waste coupling & PVC flush pipe of 32 mm dia of suitable length and complete internal macanism including brackets, complete all as specified and directed.
S&F in repairs PVC (SWR) 110mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or floors, complete all as specified and directed.
S&F in repairs 110 mm bore PVC (SWR) bends, any radius, complete all as specified and directed.
S&F in repairs PVC (SWR) 75mm bore pipes single socketed, in any length with rubber ring joints, fixed to walls as in rain water pipe, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends, any radius, complete all as specified and directed.
S&F in repairs PVC (SWR) branch piece, 110mm bore, single (Single Y) equal or unequal, with access door, complete all as specified & directed.
S&F in repairs PVC (SWR) vent cowl 75mm bore, complete all as specified & directed.
M&L for framed work as in grills, gratings etc. with ends of bars shouldered and / or rivetted, or forged into spikes; framed guard bars; barred iron door, railings and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
M & L for mild steel work as in small article such as bands, straps, supports or stay for rainwater pipe including nut bolts, hold fasts etc confirming to Fe-290 Gde-E-165, complete all as specified and directed.
S & F of small fittings made out of 2nd class hardwood (SAL) such as brackets of any type latch and hinge block door and window stops and the like article n. exc. 200 cucm each complete all as specified and directed.
S&F in repairs, 75mm dia, cast iron floor trap with and including suitable size chromium plated stainless steel grating including jointing to waste pipe, fixed to cement concrete type B1 1:2:4, complete all as specified and directed.
Taking down looking mirror of any type and size and re-fixing the same in same location / position, fixed with PVC rawl plug & chromium plated screws and cup washer etc., complete all as specified & directed.
S&F in repairs brass chromium plated shower rose with or without swivel joints 125 mm size including fixing to iron pipes or union, complete all as specified and directed.
Taking down chowkhat or frames exc. 1.5 sqm but n. exc. 4 sqm each with shutters (without taking off shutter from the frame), complete all as specified and directed.
Taking down chowkhat or frames n. exc. 1.5 sqm each with shutters (without taking off shutter from the frame), complete all as specified and directed.
Taking down shutters of any description n. exc. 1 Sqm each, complete all as specified and directed.
Taking down shutters of any description exc. 1 Sqm each and n. exc. 2 Sqm each, complete all as specified and directed.
Taking down and refixing of shutters of any description in same opening exc. 1 Sqm each and n. exc. 2 Sqm each, complete all as specified and directed.
Taking down and refixing of shutters of any description in same opening n.exc. 1 Sqm each, complete all as specified and directed.
S & F 35mm thick second class hard wood, factory made glazed and skeleton door shutter open rebated and prepared to receive glass or gauge etc (Without sash bar) edges of framing plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note :- Size of member of shutters shall be as specified in SSR Part-I 2009 section 8 clause 8.24(a).
S & F 30mm thick second class hard wood, factory made glazed and skeleton door shutter open rebated and prepared to receive glass or gauge etc (Without sash bar) edges of framing plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note :- Size of member of shutters shall be as specified in SSR Part-I 2009 section 8 clause 8.24(b).
S&F 35mm thick, factory made, plain framed, panelled shutter (Two panel) with IInd class hard wood rail & style, lock rail and panel of 9 mm BWP commercial ply or 12 mm thick vaneered particle board with commercial vaneering on both faces. The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
M&L for 25mm thick block boards, grade 1 quality, exterior grade, decorative type with decorative face veneer on both faces as in cup board shutters / shelves, fixed with screws to timber frame-work including 25mm wide x 6mm thick teak wood beading fixed with nails all around the shutter / shelves, complete all as specified and directed
M&L for 18/19mm thick block boards, grade 1 quality, exterior grade, commercial type as in cup board shutters / shelves, fixed with screws to timber frame-work including 18/19mm wide x 6mm thick teak wood beading, fixed with nails all around the shutter / shelves, complete all as specified and directed.
S&F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F wire netting of galvanised steel wire 1.40mm dia, size of mesh 25x25mm, fixed with tinned tacks of wire staples, complete all as specified and directed
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 95 mm x 45 mm having double rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge
Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (FRP) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer-in-charge
S&F for 100 mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F for 100 mm mild steel barrel tower bolts, stove enamelled black with bright bolts and fixed complete all as specified and directed.
S&F for 150 mm mild steel barrel tower bolts, stove enamelled black with bright bolts and fixed complete all as specified and directed.
S&F floor door stopper, over all length of cover plate 140 mm of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in door, complete all as specified and directed.
S&F 300mm length of bolt, aluminium alloy, anodised, sliding door bolts with hasp staple (bolt type) anf fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast alluminium alloy, complete all as specified and directed.
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
S&F 100 mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
M&L for applying two coats cement base paint (snowcem) over a coat of alkali resistant priming paint on new walls surfaces, including preparation of surface of walls, complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by brooming down or steel wire brushing, moulds, moss and efflorescent salts etc and applying two coats cement base paint (snowcem) of white or tinted colour over a coat of alkali resistant priming paint, complete all as specified and directed.
M&L for two coats of oil emulsion distemper over a coat of primer on new surfaces of walls inlcuding chalk whiting on new plastered surfaces as in preparatory work prior to distempering, complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by brooming down or steel wire brushing, moulds, moss and efflorescent salts etc and applying two coats of oil emulsion distemper of white or tinted over a coat of primer, complete all as specified and directed.
M&L for three coats white wash on new plastered surfaces of ceilings including preparation of new surfaces, complete as specified and directed.
M & L preparing old decorated plastered surfaces of ceilings by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot and applying two coats of white wash complete all as specified and as directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for sewage line, manhole or for laying cable etc. not exceeding 10 sqm on plan and getting out in in hard / dense soil complete all as specified and as directed.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed.
Removing excavated materials (Soil) n. exc.50m and depositing where directed at a level n. exc. 1.50m above the starting point, complete all as specified.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling / mass concrete, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate), 75 mm thick as in plinth protection laid as to bays finished even and smooth without using extra cement including forming necessary joints 12mm wide to the full depth of PCC at every 3 m and at change in direction, complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in surface channels and drain, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred / stopped end, complete all as specified and directed.
M&L for granite marble slab work, 18-20mm thick (Table rubbed and polished), as in steps, jambs, pillars, window cills, cooking & wash basin plateforms and like, set in CM 1:4 including pointing in white cement 1:2 using marble dust with mixture of pigment to match with shed of marble with & including 15 mm thick screed bed of CM 1:4 including rounding off exposed edges of slab, complete all as specified and directed.
M&L for machine cut kota stone slab as on riser, trade such as dado / skirting, steps etc. 20-25mm thick, laid over and including 10mm thick screed bed in cement mortar 1:4 base, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing, polishing until mirror finish & round off the exposed edges of trade of steps, complete all as specified and as directed. Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer on new wooden surfaces, complete all as specified & directed.
M & L preparation of old painted surfaces of wood & wood based material of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surface of any description exc. 10 cm width or girth, including preparation of new steel surfaces, complete all as specified and directed.
M&L for preparation of old existing steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint on old steel surfaces, complete all as specified and directed.
M&L for preparing zinc (or galvanised) surfaces to receive painting, by coating with mordant solution including washing and cleaning etc., and applying two coats of roof paint (Coptic of Jenson & Nicholson paint or Antisol of Berger paint or equivalent make) over a coat of red oxide primer on steel and iron surfaces of CGI / PGI roof sheets of any description not otherwise described, complete all as specified and as directed
M&L for preparing old painted steel and iron surfaces of CGI / PGI roof sheets of any description not otherwise described, over 10 cm width or girth by straightening, cleaning, removing rust and washing with water etc. to receive painting and making good with red lead putty where ever required and applying two coats of roof paint (Coptic of Jenson & Nicholson paint or Antisol of Berger paint or equivalent make), complete all as specified and as directed.
S & F in repairs 20mm dia aluminium anodised curtain rod, fancy type with and including MS brackets & fancy type PVC end knobs (02 Nos. in each curtain road), complete all as directed
S&F sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes coupling, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915mm x460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed
Taking down cement plaster on brick walls including raking out joints, hacking for key, scrubbing down with water etc. and removing the rubbish / debris to a distance n. exc. 250 m, complete all as specified and as directed.
M&L for 15mm thick cement plaster on fair faces of brick work or concrete surface on walls in CM 1:6 finished the surfaces even & smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick cement plaster on other than fair faces of brick work or concrete surface on walls in CM 1:6 finished the surfaces even & smooth without using extra cement and having dubbing out average 10mm thickness on irregular faces of walls, complete all as specified and directed.
M&L for 15mm thick cement plaster on fair surfaces of brick work or concrete surface on walls in CM 1:4 finished the surfaces even & smooth without using extra cement with mixing water proofing copound @3% by weight of cement, complete all as specified and directed. Note :- Water Proofing Compound shall be measured & paid separately under respective item.
M&L for 10mm thick cement plaster on fair surfaces of brick work or concrete surface on walls in CM 1:4 finished the surfaces even & smooth without using extra cement, complete all as specified and directed.
M&L for 5mm thick cement plaster on fair concrete surfaces of ceilings in CM 1:3 finished the surfaces even & smooth without using extra cement, complete all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane, including hacking out (If any) old broken glass (any thickness, quality & size), complete all as specified and directed.
S&F 3 mm thick figured sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane, including hacking out (If any) old broken glass (any thickness, quality & size), complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed
Demolition of reinforced cement concrete in any description and in any position not otherwise specifically provided for and removing the rubbish / debris to a distance as directed by Engr-in-charge, complete all as specified and directed
M&L for RCC (Design Mix) M-25 using 20 mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
M&L for form work to soffits of suspanded flat slab such as roof slabs, floor slabs, landing, shelves and similar work n. exc. 200mm thick (horizontal or sloping), rough finished, complete all as specified and directed.
M&L for TMT bars, 6-8mm, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge / thickness in roof covering etc, complete all as specified and directed.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an approved colour, having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified, complete all as directed.
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an approved colour, having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified, complete all as directed.
S&F 0.63 mm thick galvanised corrugated mild steel sheeting class 8 (zinc coating @ 275 gram per sqm inclusive of both sides) with two corrugation side lap fixed with 'J' or 'L' hooks including with washers as in roof covering, wall etc. complete all as specified and directed.
S&F 0.63 mm thick galvanised corrugated mild steel sheeting class 8 (zinc coating @ 275 gram per sqm inclusive of both sides) with two corrugation side lap fixed with 'J' or 'L' hooks including with washers as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), wall etc. complete all as specified and directed
Fixing only plain or corrugated steel sheeting any gauge / thickness with two corrugation side lap fixed with 'J' or 'L' hooks including with washers as in roof covering, wall etc. complete all as specified and directed. Note :- Serviceable sheet, obtained from serial item nos. 125 shall be re-used under this item.
Dismantling of walls/ceiling boards(fibre, pulp, insulation, etc) or insulation boards/ slabs / blankets, any thickness including cover fillets etc, complete all as specified and directed.
S&F in repairs aluminium anodized snap grid frame work for false ceiling comprising of the following sections for making partitions of 600x600mm size fixed to walls with rawl plugs and screws and hang to roof with hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and as directed:- (a). main runner 37x24x0.30mm thick (b). Cross Tee28x24x0.3mm thick (c). Wall angle 24x24x0.30mm thick
All as per item no.132 but except snap grid, fixed to walls as in repairs with rawl plugs and screws and hang to roof with hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and as directed. Note :- Serviceable snap grid, obtained from serial item nos. 129 shall be re-used under this item.
S&F 4mm thick non asbestos fiber designer ceiling board (E-Board classic) for insulation and acoustic purposed, 595x595mm in size, fixed with staples on snap grid as in ceiling with and including dusting of surfaces and applying two coats of oil bound (White or tinted in colour as directed) distemper over a coat of primer, complete all as specified and directed.
All as per item no.134 but except non asbestos fiber designer ceiling board, fixed with staples on snap grid as in ceiling with and including dusting of surfaces and applying two coats of oil bound (White or tinted in colour as directed) distemper over a coat of primer, complete all as specified and directed. Note :- Serviceable non asbestos fiber designer ceiling board, obtained from serial item nos. 133 shall be re-used under this item.
S&F 100mm sizes mild steel butt hinges medium weight, cold rolled, complete all as specified and directed.
S&F 75mm sizes mild steel butt hinges medium weight, cold rolled, complete all as specified and directed.
S&F 50mm sizes mild steel butt hinges medium weight, cold rolled, complete all as specified and directed.
S&F continuous (piano) hinges, mild steel, bright finish, width of flaps (When open) 30mm, complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed.
S&F IInd class hard wood boarding as in flooring /skirting / walls, 25mm thick, planed one side, with butt joints and fixed with nails, complete all as specified and directed
Fixing only IInd class hard wood boarding as in flooring /skirting/ walls, anythickness, planed one side, with butt joints and fixed with nails, complete all as specified and directed Note :- Serviceable IInd class hard wood boarding, obtained from serial item nos. 140 shall be re-used under this item.
Supplying and laying APP based modified water proofing polymeric membrane reinforced with non woven polyester fabric matt (weight not less than 150 gram/sqm) of minimum 3mm thick, weight not less than 3 Kg/sqm, laid over & including 15 mm thick rendering in cement mortar 1:4 on concrete surfaces, finished the surfaces even and smooth including mixing of water proofing compound @ 3% by weight of cement over a bituminous shalitex primer @ 0.30 Kg/sqm evenly over a coat of hot bitumen 85/25 @ 1.2 Kg/sqm. The membrane shall be unrolled and bonded completely to the substrate (with overlap of 100mm on the transverse direction and 75mm on longitudinal direction and sealed by thermos fused torch) and the overlaps sealed / fused by thermos fused torch as per manufacturer instructions. A coat of non reflective bituminous aluminium paint @ 0.150 Kg/ Sqm, complete all as specified and as directed Note :- Water proofing compound shall be measured & paid separately under respective items of BOQ
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, complete all as specified and as directed.
Labour for stripping out old tar felt from roofs, parapets, chimney stacks etc. as laid horizontally or vertically and removing debris to a distance n. exc. 250.00 m, complete all as directed
M & L for 50mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), complete all as specified and directed
M & L for 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate), complete all as specified and directed
Rough excavation in hard / dense soil, n. exc. 1.50m deep and getting out and removing excavated materials exc. 250m but n. exc. 500m and depositing where directed at a level n. exc. 1.50m above the starting point, complete all as specified
Soil filling under flooring or in foundation including well ramming, watering, spreading & levelling in layers n. exc. 25 cm thick, complete all as specified and directed
M&L for PCC 1:5:10 type E-2 using 40 mm graded crushed stone aggregate as in foundation filling / mass concrete (as in sunken floor) with and including demolition of existing PCC / lean concrete from sunken portion and removed the same to a distance as directed by Engr-in-Charge, complete all as specified & directed.
M&L for 40mm thick PCC 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate mixed with integral water proofing compound (As per manufacturer's instructions) as in bottom surface of sunken portion with proper slope towards spout pipe with and including 15mm thick rendering in CM 1:3 mixed with integral water proofing compound (As per manufacturer's instructions) on vertical surfaces when concrete is green. After laying sewage / plumbing pipes in position , two coats of OMIPLAS EP-101 epoxy compound shall be applied, complete all as directed. Note:- (i) Water tightness test shall be carried out by ponding test for 72 hours & defects (If any) observed shall be rectified by the contractor at his own cost as directed by Engr-in-Charge. (ii) The process of grouting & ponding test shall be repeated until leakage / seepage / dampness of sunken portion not stopped.
S&F 25mm dia GI pipe, medium grade as in spout pipe, jointing and testing for leakage proofing from around the spout pipe, grouting in wall by making hole of suitable dia and making good the disturbed surfaces of wall with existing finish, complete all as specified and as directed
Surface excavation in hard / dense soil n.exc. 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (Using 40mm graded crushed stone aggregate) as in sub base of floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed
M&L for chequrred cement concrete tiles 300x300x25mm thick, coloured rubber pressed, glossy finish, set, jointed and pointed in neat cement slurry as in floors / steps, laid over and including 15mm thick screed bed in cement mortar 1:6, set, complete all as specified and as directed
Taking down carefully Copper/Aluminium point wiring (Light fan socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc), removing materials from site and making good disturbed surface of walls, floors etc, complete all as specified and directed.
M&L for concealed point wiring surface type with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non- metallic concealed PVC conduit 20 mm or higher dia (including chase cutting in brick / stone/ block masonry walls for fixing conduit and making good disturbed surfaces), light grade ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire of PVC insulated, unsheathed, green in colour 1.5 Sqmm multistranded copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly , screwed with brass screws, cup washers and making good the disturbed surfaces, complete all as specified and directed for the following :- (a) One light point/ exhaust / ceiling fan point/bell point controlled by one, one way switch of 5/6 Amps complete all as specified and directed.
(b) One 3 pin 5/6 amps socket out-let point on independent board controlled by one, one way switch of 5/6 amps on independent board complete all as specified and directed.
(c) One 3 pin 5/6 amps socket out-let point on same board controlled by one, one way switch of 5/6 amps on independent board complete all as specified and directed.
(d) One light point controlled by two way switch
All as per item No. 158 herein above but with 2.5 Sq mm cable (FRLS) for one 15 Amp socket outlet controlled by one switch on independent board and 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable as continuous earth wire complete all as specified and directed.
S&F switch piano flush type, single pole, one way 5/6 Amps complete all as specified and directed
S&F switch piano flush type, single pole, two way 5/6 Amps complete all as specified and directed
S&F socket out let, two in one 3 pin 5/6 Amps and 2 pin 5/6 Amps , flush type, non shutters, non interlocking, complete all as specified and directed
S&F socket outlet two in one 3 pin 5/6 and 3 pin 15/16 amps (multipurpose), flush type non shutter, non inter locking type complete all as specified and directed
S&F in repairs switch piano flush type, single pole, one way 15/16 Amps complete all as specified and directed
S&F ceiling rose surface bakelite 62.5 mm x 25 mm two to three terminals complete all as specified and as directed.
S & F Lamp holder, PVC / polycarbonate with back plate & metal ring suitable for batten fittings, complete all as specified as directed
S&F in repairs 10 watts LED light fitting, bulkhead luminaires with PDC aluminium housing including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified & directed
Supply and fixing in repairs LED lights fitting 1x20 Watts, 220 Volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, complete all as specified and directed
S&F in repair MCB DB sheet metal enclosure for DB, SPN, 8 way having protection with 200 amps rated bus bar, 240 volts, double door type, suitable for housing MCB's and isolators, concealed in wall, complete all as specified and directed.
S&F in repair MCB DB sheet metal enclosure for DB, TPN, 4 way having protection with 200 amps rated bus bar, 415 volts, double door type, suitable for housing MCB's and isolators, concealed in wall, complete all as specified and directed.
S&F in repair MCB single pole & neutral, 240 volts, 'B' Curve, 32 Amps, 10 KA, complete all as specified and directed.
S&F in repairs MCB single pole, 240 volts, 'B' Curve, 6-32 Amps of 10 KA, complete all as specified and directed.
S&F in repairs MCB double pole (Isolator), 240 volts, C Curve, 40 Amps of 10 KA, complete all as specified and directed.
S&F in repairs MCB four pole (Isolator), 415 volts, 40-100 Amps, complete all as specified and directed.
S&F electric bell, multi music type AC 230 Volts complete all as specified and as directed.
S & F switch bell push button type 5 Amp single pole complete all as specified and as directed.
S & F in repair 9 watt LED bulb, cool day light, 230/240 volts AC, complete all as directed.
S & F sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 20 Amp, 240 volts, 10 KA, B curve complete all as specified and as directed.
Supply and fixing in repairs LED light fitting mirror type with high output diffuser 2 feet, 1x5 watt, 220 Volt AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size & length, complete all as specified and directed
Supply and fixing in repairs LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixing the same with 25mm dia GI pipe light grade bracket, 1.5 mtr long including necessary cutting / bending /welding and fixed the same with two Nos FI clamps of 40x4mm duly painted and suitable size of nut & bolts etc. and making electrical connection with three core copper flexible wire of 1 Sqmm upto ceiling rose, complete all as specified and directed.
S&F in repairs sub main wiring with PVC insulated, unsheathed two single core cable 1100 volts grade with copper conductor of size 2x6.0 sqmm of code Red for phase, black for neutral & green for earth, multi stranded drawn into & including suitable dia PVC conduit with and including 4.0 sqmm green stranded copper conductor as contineous earthwire with lugs complete all as specified and as directed. Note: (i) Cost of PVC conduit and accessories shall be deemed to be included in quoted rates. (ii) Two runs of 6 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and one run of PVC pipe shall be a unit length.
Supply and laying 40mm bore, GI pipe, light grade, laid under roads / floor / culvert, fixed to poles, walls with & including flat iron clamps bolts / nuts / washers / fittings (if any), complete all as specified and directed.
Supply and laying 25mm bore, GI pipe, light grade, laid under roads / floor / culvert, fixed to poles, walls with & including flat iron clamps bolts / nuts / washers / fittings (if any), complete all as specified and directed.
S&F exhaust fan, metal body, heavy duty, copper winding with self-louvers shutters with frame, AC single phase 230 Volt of size 300 mm sweep by grouting both ends in wall up to required length, including making hole of suitable size & making good disturbed surfaces of wall to match the existing surface & and removing the rubbish / debris to a distance as directed by Engr-in-Charge and connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to exhaust fan, complete all as specified and as directed.
S&F exhaust fan, made of sturdy Engineering plastic complete, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250m with self-louvers shutters with frame, AC single phase 230 Volt, grouting both ends in wall up to required length, including making hole of suitable size & making good disturbed surfaces of wall to match the existing surface & and removing the rubbish / debris to a distance as directed by Engr-in-Charge and connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to exhaust fan, complete all as specified and as directed
Taking down carefully existing serviceable water storage electric geyser of any capacity and re-fixing the same in same location after completing the addition & alteration works, with and re-connecting with inlet & outlet water pipe lines & electric connections and testing to ensure its smooth functioning, complete all as directed
S&F 25 litres capacity water heater (Geyser) storage type, BEE 5 star rated with and including grouting 04 Nos. bolts, nut & washers in wall with and including 02 Nos. chromium plated PVC connection, suitable for hot & cold water & making connection complete all as directed.
Supplying, laying and fixing along the poles or passing through pipes or laid under trenches / floor or through walls etc. jointing and testing, insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross sectional area 70 Sqmm X 3.5 Core including taking down of old unserviceable existing cable, complete all as specified and directed. Note :- (i) Excavation & earth work shall be measured and paid separately under respective items of BOQ.
Supplying, laying and fixing along the poles or passing through pipes or laid under trenches / floor or through walls etc. jointing and testing, insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross sectional area 25 Sqmm X 4 Core including taking down of old unserviceable existing cable, complete all as specified and directed. Note :- (i) Excavation & earth work shall be measured and paid separately under respective items of BOQ.
M & L for laying of dry, clean fine sand as in cushioning or filling in trenches around underground cable, in ducts etc. complete all as specified and directed.
Supply & laying of sub class ‘B’ old size bricks, laid flat i.e length of brick shall be laid across the length of cable for protection of under ground cable complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead i.e GI strip of 32x6mm size by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 2009 Part–I connected to earthing test point including earth continuity conductor and loop earthing etc. as required GI earth strip of 32x6mm size including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4, type B1 & pit cover, 75mm thick in RCC 1:2:4, type B1 dully reinforced with 6mm dia bar @ 150 mm c/c both ways including with two Nos. lifting handle of MS round bar 10 mm dia and earth lead with and including GI protection pipe light grade 40 mm dia up to 7.5 m from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed. Note:- (i) Earth lead beyond 7.50m from electrode to earth terminal point / main switch & GI pipe light grade. 40mm dia for protection against mechanical damage to lead shall be measured and paid separately under respective items. (ii). On testing after completion, if desired resistance is not obtained, the earthing will be re-done by the contractor at his own cost and no extra payment to the contractor will be admissible on this account.
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 2009 Part–I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4 mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4, type B1 & pit cover, 75mm thick in RCC 1:2:4, type B1 dully reinforced with 6mm dia bar @ 150 mm c/c both ways including with two Nos. lifting handle of MS round bar 10 mm dia and earth lead with and including GI protection pipe light grade 15 mm dia up to 7.5 m from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed. Note:- (i) Earth lead beyond 7.50m from electrode to earth terminal point / main switch & GI pipe light grade. 15mm dia for protection against mechanical damage to lead shall be measured and paid separately under respective items. (ii). On testing after completion, if desired resistance is not obtained, the earthing will be re-done by the contractor at his own cost and no extra payment to the contractor will be admissible on this account.
Builders Harpal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .