Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.8 LAdmitted-Fee/PreQual/Technical/Finance | -9.61% | ₹3.8 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹4.2 LAdmitted-Fee/PreQual/Technical/Finance | +0.00% | ₹4.2 L | L2 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹4.2 L
EMD Value
₹10,530
Closing Date
27 Jul 2026, 12:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER, ELECTRICAL SUBDIVISI
OFFICE OF THE ASSISTANT EXECUTIVE ENGINEER, ELECTRICAL SUBDIVISION, TDB,SOUTH NADA-SREEKRISHNASWAMY TEMPLE,MAVELIKKARA-690101
Thiruvallam Devaswom, Thiruvananthapuram Group Karkidaka Vavu Festival 1201 M.E Urgent Electrical Maintenance Works at Bali Mandapam, Santhi Room, Sivan Namaskara Hall, Nalambalam, Bali Kadavu Mandapam, and Kadavu Parking Area-reg.
2026_TDB_862218_1
AEE/EL/ET-92/2026-27
Open Tender
Electrical Works
Percentage
10 days
Trivandrum
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
₹10,530
27 Jul 2026
23 Jul 2026
27 Jul 2026
23 Jul 2026
27 Jul 2026
23 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1electrical | |||||
| 1.001 | OD102516/2026-2027:Dismantling and removing the damaged accessories from the existing electrical installations, and also stacking carefully.
Electrician | - | no | 1,244.27 | - |
| 1.002 | OD102515/2026-2027:Dismantling and removing the damaged accessories from the existing electrical installations, and also stacking carefully.
Wireman Helper | - | no | 690 | - |
| 1.003 | 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | - | each | 7,562.56 | - |
| 1.004 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture | - | each | 1,249.13 | - |
| 1.005 | 90.2.1.15:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Long Point | - | point | 1,468.29 | - |
| 1.006 | 90.2.1.8:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Medium Point | - | point | 1,229.11 | - |
| 1.007 | 1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required. | - | each | 154.17 | - |
| 1.008 | 90.12.1.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm | - | metre | 498.93 | - |
| 1.009 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | - | metre | 86.9 | - |
stage.html
html • 0.02 MB
finance_1458252.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.23 MB
IntegrityPact.pdf
Tender Documents • 0.05 MB
FoT.pdf
Tender Documents • 0.19 MB
preliminaryagreement.pdf
Tender Documents • 1.18 MB
epaymentnew.pdf
Tender Documents • 0.16 MB
Affidavit.pdf
Tender Documents • 0.06 MB
SBD92THIRUVALLOMMAINTANANCE.pdf
Tender Documents • 1.97 MB
BOQ_1458252.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].