Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 CrAccepted-AOC KURUDANTAYYATH KADATHOOR PO THAZHAVA KARUNAGAPPALLY KOLLAM DISTRICT KERALA | PATHANAMTHITTA | KERALA | 689694 | ₹6.9 Cr | L1 | Accepted-AOC agreement executed |
| 2 | L2₹7.4 CrRejected-AOC | ₹7.4 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹7.8 Cr
EMD Value
₹2 L
Closing Date
10 Feb 2026, 5:00 pmClosed
Superintending Engineer
O/o SE, PWD Buildings South Circle, TVPM
GENERAL-Construction of New BTS garage and Compound wall In KSRTC KayamkulamConstruction of New BTS garage-Composite Work-.-Composite Work
2026_PWD_830357_1
PWD/BLDG/TR/23865/2025_23_2_
Open Tender
Civil Works - Buildings
360 days
Alappuzha
Please refer Tender documents.
7 documents required · 7 mandatory
₹13,010
Yes
₹2 L
Yes
11 Mar 2026
24 Jan 2026
13 Feb 2026
24 Jan 2026
10 Feb 2026
24 Jan 2026
Construction of New BTS garage and Compound wall In KSRTC Kayamkulam(Civil work)
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
OD262694/2025-2026:Providing stone columns of 100 mm diameter using 12.5 mm and down graded metal at 30cm center to center and disposable MS cone 1.50 mm thick of suitable size at bottom including the cost of MS cone etc. complete as directed by departmental officers at site. 5.50m depth stone columns . Numbers of MS Cone = 165/5.50 = 30 Nos
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD262693/2025-2026:Conducting Plate load test
OD262695/2025-2026:Improvement of foundation by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III (using MSand and coarse aggregates size range 4.75mm to 20 mm ) having CBR Value - 20
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
OD262688/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is not payable or not recoverable separately. All work upto plinth level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD262686/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is not payable or not recoverable separately. All work above plinth level upto floor V level.
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
9.147C.2:Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm)
OD262692/2025-2026:Providing, assembling and supplying Frosted glass panel units of size and shape as required and specified, all complete for the required performances, as per the Architectural drawings as specified and as directed by the Engineer-in-Charge.
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
25.6: Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of relevent item*). ?(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
OD262687/2025-2026:Providing and laying matt finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
11.20.4:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Ordinary cement without any pigment
16.90:Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
OD262691/2025-2026:Supplying and fixing 304- grade Stainless Steel 90 & deg; with Anti- Slip Nylon Grip wall Mounted Safety L shaped Grab Bar for toilets, including fixing charges etc. complete.
OD262690/2025-2026:Supplying and fixing 304- grade Stainless Steel wall mounted swing up bathroom safety Grab bar of size 740 mm length, including fixing charges etc. complete.
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
17.7.1:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
17.23:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
17.73.1:Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms
50.18.9.2.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints as per direction of Engineer in Charge.20 mm dia 12 Kgf/cm2
50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.8.4.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2
50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
50.18.8.8.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
18.58.1.1:Providing and fixing PTMT grating of approved quality and colour. Circular type100 mm nominal dia
50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow
50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow
50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl
50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
50.18.9.21.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
OD262689/2025-2026:Supplying and providing ready made RCC Septic tank of capacity 50 flush per day etc including non returnable valve, Soak pit and cost of earth work, transportation, loading and unloading and installation charges etc.
ELECTRIFICATION(Electrical work)
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD280263/2025-2026: Supply, conveyance installation testing and commissioning the light fittings of following types surface /pendent mounted IP65 high efficiency technical linear luminaire Model No.LE23-501-XXX-57-HE (Imperia / LE23 32W/5700K.) Wipro/Equivalent 3 core copper conductor flex wire conforming to relevant ISS and giving connections etc as required.
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
OD261928/2025-2026:Supply and providing High bay light having High efficiency with highbay designed to deliver optimum performance and sustained energy savings over the product life cycle under harsh industrial environments output with output 150lm/W , 80watts, with IP66 Protection, with all accessories directly on Ceiling with necessary support or metal frame and giving connection with required of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. (Wipro Make - LH21-102-90-57X2HE (Radial UNO/ LH 21(X2HE)or equivalent )
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD261950/2025-2026:LED Bulk head Supply and fixing LED Bulk head with IP65 protection suitable for surface and wall mounting application including giving connection etc as required
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
OD282249/2025-2026:Supply and fixing of safety Bowden (Fan rod )with double side end lock as required.
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
OD261949/2025-2026:Supply, conveyance, installation, testing and commissioning of 230V 50Hz 1440 rpm 24 inch wall mounting type Air circulator. (Almonard, Orient, Crompton or equivalent)
OD261931/2025-2026:Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD261948/2025-2026:Supply, conveyance, installation , testing and commissioning of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.17:Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
90.14.24.1:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.1 KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors.
90.14.28.1:S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.16:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD261929/2025-2026:SITC of RCCB Double pole 40A Type Hpi Enhanced immunity to unwanted tripping in environments with disturbances. eg. diesels, computers, printers, etc. • Detects faults with DC components eg. thyristors, trio etc
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.7:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.7 x 1.5 sq. mm
1.17.8:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.16:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.7 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD282845/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x25 sqmm (clamped with 1mm thick saddle)
OD282846/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x16 sqmm (clamped with 1mm thick saddle)
OD282847/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x10 sqmm (clamped with 1mm thick saddle)
OD282848/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on cable tray as required. 2x10sqmm (clamped with 1mm thick saddle)
90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
OD282926/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required . 2x10sqmm
OD282927/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x35 sqmm
OD282928/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x50 sqmm
OD282929/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x70 sqmm
OD282930/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x95 sqmm
OD282931/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1584/(part I)/1988 for PVC & IS 7098/(part I )/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x120 sqmm
OD282945/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554(part I)/1988 for PVC & IS 7098(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 4x16 sqmm 0
OD282967/2025-2026:Supply and laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade conforming to IS 1554(part I)/1988 for PVC & IS 7098(part I)/1988 for XLPE of following size in the existing RCC/ HUME/ METAL pipe as required. 4x10 sqmm 0
90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
OD284574/2025-2026:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & shall conform to relevant IS .Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.11:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.2:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
OD282388/2025-2026:Supply and fixing Spreader/Terminal adapter Kit Extended terminal for 4 pole MCCB of rating upto 200 A & 250 A (8 pcs)
90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
OD281506/2025-2026:Supply, Conveyance ,Installation, Testing and Commissioning of Four pole AC 125A, 50 Hz, 415V Automatic Transfer Switch (ATS) along with AuXC C 2000 controller having protection from UV/OV, Single phasing, Phase sequence and Frequency with Complete protection,5 key s navigation keypad for parameters setting,4 LEDs for plant synoptic (source line and ATS status) ,2 LEDs for alarm presence and AUTO mode active 128x 80 pixel, Backlit LCD screen with 4 Grey levels, Management of generator set start-stop & cooling cycle Management of automatic test for generators with emergency and rotation conforming to IS/IEC 60947-3, EN 60947-3 IS/IEC 60947-6-1, EN 60947-6-1 in existing panel including connections, etc. as required. Make L& K or equivalent.
OD261941/2025-2026:Supply and fixing 150/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT in the existing panel assembly as required.
OD261946/2025-2026:Supply and providing Blue colour LED indicator lamp, AC/DC, 22.5 cm cut out dia
OD261930/2025-2026:Supply and fixing Red, Green, Black, Yellow, Orange colors LED indicator, AC/DC, 22.5 mm cut out dia
OD284554/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.1.50sq mm wire single run
OD284558/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.10.00sq mm wire single run
OD284559/2025-2026:Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providing suitable size insulated sockets at the termination points or soldered properly,providing numbering ferules for the proper identification of the wiring, keeping the wiring firm by suitable tie/tie mounts/PVC duct etc as required.6.00sq mm wire single run
OD261927/2025-2026:Supply and fixing 125A Cutout Fuse with 100/80A HRC Link connection in existing meter board
OD261942/2025-2026:Supply and fixing 32A Cutout Fuse with 16/20/25A HRC Link connection in existing meter board
OD261934/2025-2026:Supply and fixing 100A 2Way neutral link with connection in existing meter board
OD261935/2025-2026:Supplying and fixing 32A, 2Way Neutral Links Mounted on DMC/SMC Base with connections in existing meter board
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
OD261940/2025-2026:Supply and fixing Emergency push button with enclosure of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button on wall and giving connection etc. as required
4.1.4:Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
OD261947/2025-2026:Painting letters or figures with enamel paint as identification mark to SB, DB, panel board etc as required
OD261953/2025-2026:Supply and providing 4/5 Kg. ABC Type - Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
OD261952/2025-2026:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
OD261951/2025-2026:Supply and providing 2.5mm thick synthetic VC fire retardent insulating sheet to withstand 3.3 KV dielectric strength conforming to IS
OD261943/2025-2026:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD284482/2025-2026:Providing and fixing 25 X 3 mm copper strip on surface or in recess for connection using copper saddles ,Al alloy/cadmium plated iron screws,40mm long PVC fastener as required.
OD282309/2025-2026:Providing and drawing 4.00 mm (8 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD282310/2025-2026:Providing and drawing 3.15 mm (10 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD282311/2025-2026:Providing and drawing 2.65 mm(12 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD282312/2025-2026:Providing and drawing 6.00 mm (4 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.5.6:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG)
OD261939/2025-2026:Supply and Providing 25x3mm brass bolt as required
OD261938/2025-2026:Supply and Providing 25x6mm Brass Bolt as required.
OD265034/2025-2026:Supply, Installation, Testing and Commissioning of 1 KVA UPS, 42AH 3 Nos tubular battery and all accessories having 60 min. backup time with the following specifications. a) 1 ph to 1 ph b) Input pf : 0.99 @ full load c) Output pf : unity d) Input voltage range : 140V -280V with cut off e) THD : ≤ 10% f) Overall Efficiency : ≥87% g) Ambient Temperature : 0-40°C h) Generator Compatibility. i) Pure sine wave. j) Battery over charge & under charge cut off. k) Bypass arrangement. l) EN/IEC 620401 for General Safety compatibility m) EN/IEC 620402 for Electromagnetic Compatibility. n) EN/IEC 620403 for Performance o) EN/IEC 620404 for Environmental Compatibility p) battery : exide / panasonic or equivalent
90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid
90.9.1.2:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
90.9.1.3:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 Degree /Tee
90.9.1.4:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
90.9.1.5:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal coupler
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.15.2.3:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters
OD281339/2025-2026: Supply Conveyance, installation, testing and commissioning of 24000 lumen LED, efficacy >=120 Lm/watt, IP 66 flood light fitting with die-cast aluminium housing, toughed glass, Anti corrosive coating with natural salt spray tested for 500hrs complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux duly wired up for use on 230V AC supply.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD261936/2025-2026:Supply and providing Low intensity Integral LED aviation obstruction light with yellow painted die-cast aluminium alloy housing, red coloured polycarbonate enclosure, peak intensity at night min. 32 cd/sq. meter
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
OD261957/2025-2026:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD261954/2025-2026:Supply & installation of dust and vermin proof, 1 Phase Sintex Meter Board(GS-MB-3425 Single Compartment) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required.
90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm
OD261959/2025-2026:Supply and installation of 2 pole 32 A contactor in the control box of High mast Light system.
OD261958/2025-2026:Supplying and fixing 40A, double pole, 240 volts,center OFF COS in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD261955/2025-2026:Supplying and fixing 24Hr Timer switch with NO/NC operating voltage 230V in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD283871/2025-2026:Earthing with CPRI tested maintenance free, low carbon, 250 Micron copper-coated 3 meters (1mtrx3Nos),20 mm Dia, earth rod with peg and bore arrangement.
OD283869/2025-2026:Supply and installation of Earth conductivity enhancing mineral compound tested as per IEC 62561-7,TCLP tested.
OD283872/2025-2026:Supply and providing of Plastic Corrosion Protection strip: Approx. 1.1 mm thick. Width 50mm. and 10 meter length Made of petrolatum-coated chemical fibre fabric.
OD284113/2025-2026:Supply and installation of 8 mm diameter Aluminum Round Conductor in the existing conductor holder complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305-3) (Horizontal run)
OD284120/2025-2026: Supply and installation of Roof conductor holder for sheet, bottom section & conductor holder made of stainless steel (V2A) with Ø 8.5 mm slot at bottom 2
OD284124/2025-2026:Supply and fixing Polyamide roof cable holder for flat roof .
OD284125/2025-2026:Supply and installation of Roof conductor holder for parapet ( Polyamide Conductor holder) With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder With base Weather and temperature resistant from -35 to +90 degree Celsius tested.
OD283873/2025-2026:Supply and providing Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate.
OD283874/2025-2026:Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
OD283875/2025-2026:Supplying and laying of 30 mm X 3 mm galvanized steel strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of steel nut bolt & spring washer spaced at 50mm). Flat conductor shall be of Hot Dipped, Cross sectional area is 90mm square , Zinc coating 500 g/m square (Approx. :70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding.
OD283876/2025-2026: Supply and fixing Spacer clip for flat conductor, with polyamide base ,necessary bolts (M6 x 16) and over-piece from hot-dip galvanized steel.
OD283877/2025-2026:Supply and installation of Test Joint suitable to connect 8mm round conductor or 30x3 mm GI strip as specified in drawing directed by Engineer in charge with Suitable Enclosure.
OD283878/2025-2026:Supply and fixing clamping shoe made up of hot dip galvanized iron to connect 8mm air terminal with metal structure.
OD283879/2025-2026:Supply and fixing of T cross and parallel connector made of hot dipped galvanized iron with necessary hexagonal bolts (M10x30) 2nos/expansion piece.
OD283880/2025-2026:Supply and fixing of cross universal connector made of hot dipped galvanized iron with necessary screws and 4 hexagonal bolts (M8*25 with M8) and hexagonal nuts . (For T and cross connection to route vertical down conductor /mesh formation)
OD283881/2025-2026:Supply and fixing of expansion piece for equalizing temperature related length changes. (Necessary on conductors length over 20 meters.) For round conductor Rd 8/ALU
OD283884/2025-2026:Supply and fixing concrete , frost resistant , high stability 16 KG stone of 365 mm diameter for mounting interception rod using anchors.
OD283885/2025-2026:Supply and installation of Fang Fix with base and clamp for mounting air terminal rod. Fang fix clamp is made of Stainless Steel and lightning tested for 100 kA 10/350 micro sec waveform.
OD283886/2025-2026:Supply and installation of 4 meter aluminium vertical air terminal rod with all accessories conforming to IS/IEC -62305 part-3 and DIN EN 50164-2 (VDE 0815 part 202). (16mm rod tapered to 10 mm) . Air terminal shall be semi-hard and (E- AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.
OD261956/2025-2026:Supply and providing Panel include 3Ph pluggable type surge arrester in suitable enclosure Class B+C/ Type 1+2 as per IEC 61643 -11 for lightning current equipotential bonding to VDE 0185-305 (IEC 62305). Modular connectable arrestor with dynamic cut-off unit and visual status display for each cartridge. It should be included Locking mechanism with vibration protection and voltage keying for safe operation of the device. Nominal voltage -230V 50Hz, type single MOV with built in thermal fuse and cooling gel(L to N) & spark gap encapsulated / non exhausting (N to E) . Total Lightning Impulse Current - 37.5 kA (10/350µ sec) for Line to Neutral & 50 kA(10/350µ sec) for Neutral to Earth, Total Nominal discharge current- 90 kA (8/20µ sec) for Line to Neutral & 50 kA(8/20µ sec) for Neutral to Earth, Total Max discharge current - 200 kA (8/20µ sec). Voltage protection level 1400V (L to N) & 1500V (N to E). Operating temp -40º to +80ºC. Response time <25 nano sec (L to N), < 100 nano sec (N to E) DIN rail mounting type etc complete with back up fuse as required and as directed, TOV tested. The product should be tested and approved by any one of the following external testing institute(UL, KEMA, OVE, VDE)
Fire Fighting Work(Electrical work)
18.4.1:(a) Supplying, installation, testing and commissioning of electric driven900 lpm at 35m Head
18.14.5:Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia
18.12.5:Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle ,bronze or gun Metal seat, ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of following sizes as required:100 mm dia
18.11.5:Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia
OD278965/2025-2026:Ball valve-Supply, installation, testing and commissioning of C.I. slim seal type ball valve with required flanges, nuts and bolts gasket etc. complete 25mm dia
OD278952/2025-2026:FIRE BRIGADE INLET:- Supply, installation, testing and commissioning of 4 way Fire Brigade Inlet connection of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arrangement to be connected to wet riser main.
17.1.4:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
17.1.7:FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
17.1.9.2:Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.6 Zone
17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
OD261961/2025-2026:Supply and fix LED indicators for all voltage ranges- Blue colour
OD261964/2025-2026:Supply and fix LED indicators for all voltage ranges- Red, Green, Black, Yellow, Orange colour
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.14.28.3:S & F Motor starters of the following ratingsThree phase DOL starters for 10HP motor
16.8:Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.12.7.14:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp
9.1.7:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD279013/2025-2026:Providing and drawing 3.15 mm (10 SWG) copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD261965/2025-2026:Copying charges for additional copies per A2 sheet
OD261960/2025-2026:Charges for preparation of Fire Drawing per A2 sheet first copy
OD261962/2025-2026:Supply and fixing (in appropriate location) of Fire emergency plan (colour) printed in photo paper of size A2 sand witched in clear acrylic sheet fixed using SS studs and other accessories complete as required as per the technical specification and conforming to IS 9457,IS 12349,IS 12407
18.16.1:Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Gun Metal
18.9.2:Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal or stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel
OD261970/2025-2026:Supply & Fixing of Hose cabinet made of M.S Sheet with full front glass door and locking arrangements suitable to accommodate 2 Nos 15 M long Hose pipes and 1 No Branch pipe. The cabinet shall be painted to scarlet red colour out side & Offwhite inside.
18.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 b) 20 mm nominal internal dia gun metal globe valve &nozzle c) Drum and brackets for fixing the equipments on wall. d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
18.22:Providing and fixing of pressure switch in MS pipeline including connection etc as required:
18.18.2:Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304)
OD261973/2025-2026:Supply and providing 4/5 Kg. ABC Type - Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
OD261974/2025-2026:Supply and providing 4.5 CO2 type Fire Extinguisher with hose and clamps including fixing it to wall as required
OD261972/2025-2026:Suply and providing emergency fire escape lighting system consisting 2 nos lamp ,7 AH MF battery charging unit ,exit sign display etc in MS enclosure
OD261971/2025-2026:SIGN BOARDS:- supply & installation of necessary Glow Sign Board made of 3 mm thick PVC foam board as per new fire station, Fire Exit passenger Lift, Electrical Duct ,Plumbing Duct, Floor level, Fire Lift in each floor.
OD261969/2025-2026:Supply & erection of Glow Sign Board made of 3mm thick PVC foam board for Assembly Point sign board 16" x 16"
18.8.5:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 65mm
18.8.6:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 80 mm
18.8.7:Providing, laying, testing and commissioning of C class heavy duty GI pipe conforming to IS 1239, i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required. 100 mm
Diesel Generator(Electrical work)
OD278568/2025-2026:Supply, Conveyance and filling of good grade Diesel for DG set as required.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
OD278703/2025-2026:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:80mm dia
OD278704/2025-2026:Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:65mm dia
OD284246/2025-2026:Supply and providing Cladding for Exhaust system by 10 inch dia aluminium cladding with 26 gauge aluminium sheet with wrapping Rock wool around the exhaust system (pipe) fixing it firmly with the pipe using chicken mesh applying overall coating to the system using 0.4mm thick aluminum sheet and make it air tight to ensure sound and thermal proof to the system. 80 mm dia C class MS pipe as extended exhaust pipe.
OD284225/2025-2026:Supply and providing Cladding for Exhaust system by 10 inch dia aluminium cladding with 26 gauge aluminium sheet with wrapping Rock wool around the exhaust system (pipe) fixing it firmly with the pipe using chicken mesh applying overall coating to the system using 0.4mm thick aluminum sheet and make it air tight to ensure sound and thermal proof to the system. 65 mm dia C class MS pipe as extended exhaust pipe.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.6.5.18:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 1.50 sq mm
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD284289/2025-2026:Providing and fixing 25 X 3 mm copper strip on surface or in recess for connection using copper saddles ,Al alloy/cadmium plated iron screws,40mm long PVC fastener as required.
OD261920/2025-2026:Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
OD261922/2025-2026:Supply and Providing 25x3mm brass bolt as required.
OD261924/2025-2026:Supply and Providing 25x6mm Brass Bolt as required.
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
OD261921/2025-2026:Copying charges of Electrical Drawing per A3 sheet additional copies
OD261923/2025-2026:Charges for preparation of Electrical Drawing per A3 sheet first copy
Air Conditioning work(Electrical work)
OD261979/2025-2026:Supply , Installation, Testing and Commissioning of 2.5 TR, 3 star rated Air Cooled Hi Wall Invertor split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), Copper evoporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract up to the end of DLP period including periodical services, gas topping etc. complete. (Including Outdoor Stand)
OD261980/2025-2026:Supply , Installation, Testing and Commissioning of 2TR,5 star rated Air Cooled Hi Wall Invertor split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), Copper evoporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract up to the end of DLP period including periodical services, gas topping etc. complete. (Including Outdoor Stand)
OD261976/2025-2026:Supply , Installation, Testing and Commissioning of 1.5 TR, 5 star rated Air Cooled Hi Wall Invertor split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), Copper evoporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract up to the end of DLP period including periodical services, gas topping etc. complete. (Including Outdoor Stand)
OD261978/2025-2026:Supply and fixing of 25mm 10Kg/cm2 PVC drain water pipe line with necessary,supports, saddles,clamps, hangers, and fittings such as bends, tees etc and insulated the entire length of the pipe with 19/25 mm Nitrile or Rubber insulation and covered by a 120 G/nearest size polythene sheet ( max-5cm width) as cladding complete with type as per specifications and as required.
OD261982/2025-2026:Supply, and fixing of the following size soft drawn Refrigerant Copper Piping size in brazed construction having minimum 22 SWG gauge, including suitable rated elbows and other necessary fittings etc for interconnecting the air conditioning indoor and outdoor units and including insulated with minimum 9 mm thick insulation chemically cross linked closed cell Nitrile rubber tube insulation with mechanical protection coating/layer, duly clamped on wall /ceiling or and supported on GI perforated cable tray as per the drawing and site conditions for connection between outdoor and indoor units.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
CCTV Surveilance System - Active Components(Electronics Work)
OD283516/2025-2026:Supply ,Installation ,Testing and Commissioning of semi manageable 24 Port Gigabit POE+ Switch having 24x PoE Gigabit ports, 4 Gigabit SFP fiber up link Ports, PoE Power minimum 190Watts with three years warranty Accepted Make: Netgear/HP/TP Link
OD283313/2025-2026:Supply, Installation, Testing and Commissioning of L2 8 port 10/100/1000Mbps PoE+ switch with 120 watts or above power budget with 2 SFP uplink ports, rack mountable switch with minimum 3 years warranty. Accepted Make: Netgear ,HP ,TP Link
OD283390/2025-2026:Supply installation Testing and Commissioning of STQC Certified 4 MP IP varifocal Bullet Camera with following specification. Image Sensor : 1/3 inch or better 4MP PS CMOS Image Sensor , 2.7mm~12mm Motorized Lens, IR Range of 50 Mtr. Video Compression H.265, H.264, H.264H, H.264B, MJPEG, WDR 120DB ,Day/Night (ICR), 3D NR, ROI, AWB, AGC, BLC, HLC , IP 67, PoE including Mounting accessories with 3 years onsite Warranty. Accepted make: CP Plus/Honeywell
OD283387/2025-2026:Supply, Installation, Testing and Commissioning of STQC certified 4 MP IR Bullet camera with 1/2.7 inch 4MP PS CMOS Image Sensor , IR Range of 50 Mtr, 2.8/3.6mm lens, Max. Resolution: 4MP, Video Compression H.265, H.264, H.264H, H.264B, MJPEG, WDR 120DB ,Day/Night (ICR), 3D NR, ROI, AWB, AGC, BLC, HLC , IP 67, PoE including Mounting accessories with 3 years onsite Warranty. Accepted Make: CP Plus,/Honeywell
OD283547/2025-2026:Supply, Installation, Testing and Commissioning of STQC certified 4 MP IR Dome camera with 1/2.7 inch 4MP PS CMOS Image Sensor , IR Range of 50 Mtr, 2.8/3.6mm lens, Max. Resolution: 4MP, Video Compression H.265, H.264, H.264H, H.264B, MJPEG, WDR 120DB ,Day/Night (ICR), 3D NR, ROI, AWB, AGC, BLC, HLC , IP 67, PoE including Mounting accessories with 3 years onsite Warranty. Accepted Make: CP Plus,/Honeywell
OD283555/2025-2026:Supply, Installation, configuration, Testing and Commissioning of STQC Certified 32 channel 4 SATA NVR with following specification :- IP Video Input 32-ch, Incoming Bandwidth 300 Mbps , Outgoing Bandwidth 300 Mbps, HDMI/VGA independent output Decoding Format H.265/H.265+/H.264+ /H.264, Network Interface: 2 RJ-45 10/100/1000 Mbps self-adaptive Ethernet interfaces. Auxiliary Interface SATA 4 SATA interfaces .Capacity Up to 20 TB capacity for each HDD, USB Interface Front panel: 2 X USB 2.0; Rear panel: 1 × USB 3.0, and with 3 year OEM onsite Warranty. Accepted Make :- CP plus/Honeywell
OD283572/2025-2026:Supply and Installation of 42 inch or higher LED Professional Display capable of working 16/7 with resolution of Full HD or higher for surveillance with wall mounting rotatable/tiltable stand. OEM warranty for 3 years. Accepted Make: Sony/LG/Samsung/Panasonic
OD283384/2025-2026:Supply and fixing 24 port Enhanced CAT-6, fully loaded rack mountable modular type patch panel as per EIA/TIA-TSB 40A specification for interconnecting servers mand clients, including termination charges Accepted make : Legrand/Molex/AMP
OD283385/2025-2026:Supply, laying, testing, certification and documentation of UL Listed ETL varified and RoHS complaint CAT 6, 1 Mtr standard factory crimped patch cord.Accepted Make: Molex/Amp/Legrand
OD283383/2025-2026:Supply and Installation of wireless mouse with USB receiver for the NVR. Approved make: Dell. Logic
OD283386/2025-2026:Supply and Installation of 10 TB Surveillance Hard Disk Drive. Accepted Make: Seagate/WD
OD283389/2025-2026:Supply and fixing of UL certified 19 inch 9U Rack with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack,2U standard ,230V 6A Inlet Plug type Indian Round Pin 6 Nos , Power Distribution Unit ,8A Fuse, ,Air circulation module 90CFM. Preferred Make: D link / Netrack/Valrack or equivalent
OD284032/2025-2026:Supply and fixing of UL certified 19 inch 17U Floor mounting Rack (600mmx600mm) with Front Glass door and lock and all mounting hardware including Horizontal Cable organizer suitable for 19 inch Rack,2U standard ,230V 6A Inlet Plug type Indian Round Pin 6 Nos , Power Distribution Unit ,8A Fuse, ,Air circulation module 90CFM. Preferred Make: D link / Netrack/Valrack or equivalent
OD283752/2025-2026:Supply and installation of ISO certified 1 KVA on line UPS with external battery, 42 Ah X 1 No SMF battery with 3 Years OEM Warranty for UPS and battery including necessary Electrical wiring
OD283382/2025-2026:Minor Electrical works for the distribution of power to Rack with all accessories including 2.5sq mm copper conductor, 20 mm PVC conduit and connection from DB/ main power source along with labor cost as required
Cabling for CCTV(Electronics Work)
OD283753/2025-2026:Supply, laying, splicing and termination of 6 core armoured single mode optical fiber cable including testing charges :Accepted Make:- Finolex, Molex
OD283754/2025-2026:Supply and installation of Duplex SC/UPC-LC/UPC Patch chord 1 mtr. Accepted Make: Molex/Honeywell/Belden
OD283755/2025-2026:Supply, Installation, Testing and Commissioning of 1G Fiber SFP -Module compatible with switches, warranty 3 years. Accepted Make: Juniper/HP/Netgear/Syrotech
OD283756/2025-2026:Supply and Installation of 19 inch 6 port rack mountable 1U size complete Steel housing fully powder coated Light Interface Unit (LIU) with required numbers of SC connectors having FR grade Nylon Cable grommets, ABS Splice Trays with fully cushioned splice holder containing grooves for fixing splice protection sleeves, Cable Spools made up of flame retardant plastic, high impact resistance, stackable design for providing sufficient room for storage of excess cables, Blanking plates, pigtail, etc. Including splicing charges. All the core must be spliced in the LIU. Accepted Make:Molex, Commscope, Legrand
OD284072/2025-2026:Supply and Installation of 19 inch 12 port rack mountable 1U size complete Steel housing fully powder coated Light Interface Unit (LIU) with required numbers of SC connectors having FR grade Nylon Cable grommets, ABS Splice Trays with fully cushioned splice holder containing grooves for fixing splice protection sleeves, Cable Spools made upof flame retardant plastic, high impact resistance, stackable design for providing sufficient room for storage of excess cables, Blanking plates, pigtail, etc. Including splicing charges. All the core must be spliced in the LIU. Accepted Make:Molex Legrand
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
PA System(Electronics Work)
OD283922/2025-2026:Supply, Installation, Testing and commissioning of 120 watts RMS PA Mixing amplifier with Built-in MP3 player with remote control for USB, SD/MMC card reader.and having following specifications : -Power Output - 160W Max., 120W RMS at 10% THD, 105 W RMS at 5% THD, Frequency Response - 50-15,000Hz Signal to Noise Ratio - 60dB, Output- Pre amp 200mV/600 ohm, Speaker Output -4 ohm, 8 ohm, 70V and 100V. Approved Make and Model :-Ahuja SSB-120.
OD283919/2025-2026:SITC of PA Horn Speaker with following Specification: Output power 25 Watt RMS, PowerTaps,25W/20W/ 15W/10W/ 5W, Impedance 400/500/670/1K ohm/ 2 K. Ohm.Frequency Response 250 - 10000 Hz, SPL120 dB/25w/1m. Built in 100 V matching Transformer,Approved Make Ahuja UHC-25XT/ SUH-25MT
OD283921/2025-2026:Supply, installation, Testing and Commissioning of 23 inch sleek Condenser Microphone with following specification:- Frequency Response - 50-16,000Hz,Sensitivity - 5.5mV/Pa, Approved Make and Model: Ahuja PGM -481 with all necessary cables and connectors
OD283920/2025-2026:SITC of Heavy Duty Goose neck Microphone base for phantom Power microphone Approved Make Ahuja PGB 48 with necessary cables and connectors.
OD283947/2025-2026:Supply, Installation, testing and Commissioing of 48V Phantom power injector with following specification :- Operating Voltage 240V AC 50Hz, Phantom Supply 48V DC, Mic Inputs 2 x Female XLR, Mic Outputs 2 x Male XLR (For Amplifier) .Approved make and Model Ahuja APS 482.
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
TV(Electronics Work)
OD284063/2025-2026:Supply, Installation, Testing and Commissioning of 55 inch 4K UHD LED TV having Resolution 3840 x 2160, input- minimum 3 HDMI ports, and minimum 2 USB ports, RJ 45 port or Built-in Wi-Fi support, 16x7 Operation hours, Minimum brightness 400nits, Operating system - Android or Google, Infrared or Bluetooth operated remote control, Power supply 100V-240V, 50/60Hz, sound output minimum 20 watts, connecting cables as required, OEM supplied table top stand/ Wall mounting Kit as required and 3 numbers of 10 Meter HDMI Cables . 3 years onsite warranty. Preferred make: Lg/Samsung/ panasonic
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
viewsbd.pdf
Tender Documents • 4.01 MB
epayment.pdf
Other Document • 0.01 MB
Integrity.pdf
Other Document • 0.17 MB
affidavit.pdf
Additional Documents • 0.26 MB
BOQ_1395054.xls
BOQ • 0.84 MB
formoftender.pdf
Additional Documents • 0.42 MB
preliminaryagreement.pdf
Additional Documents • 0.29 MB
Download all tender documents and submit your bid