Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Accepted, Being Lowest | |
| 2 | L2₹39.1 L+₹6,067.20 (0.16%)Rejected-AOC | L2 | Rejected-AOC Rejected, Not being lowest | |
| 3 | L3₹40.9 L+₹1.9 L (4.88%)Rejected-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L3 | Rejected-AOC Rejected, Not being lowest |
| Sl No | Description | Qty | Unit | TAMS ASSOCIATES L2 | SREEKRUPA ENTERPRISES L1 | Green Ray Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00Notes: - 1.Contractor should visit at site before quoting the tender to know the working condition of the station. 2.All requisite safety measures are to be adopted by contractor on site. 3.The complaint/ breakdown will be attended/rectified within two working days after informing the complaint by the undersigned or his authorised rep. 4.If contractor failed to rectify the complaint/breakdown within two day then recovery will be done at Rs. 1500.00 Per day. | ||||||
| 2.00 | Repair/ replacement old U/s LT feeder pillar box with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3mm thick CRCA sheet of suitable size duly pretreated in seven tank process for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. Panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall duly supported on angle iron of size 40x40x4mm thick. panel shall include following accessories: | 1 | Each Job | 1,05,000 ₹1,05,000 | 1,15,000 ₹1,15,000 | 67,000 ₹67,000 Lowest |
| 2.01(a) Busbar chamber (4 nos TP&N of suitable amp rating ) (Aluminium bus bar ) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assy -03 No (c) complete wiring of panel with suitable guage multi stranded copper conductor with proper colour code (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. (e) Panel should have separate chambers and busbar extensions to accomodate the following switch gears. i) MCCB TPN 400 A as incomer - 01No ii) MCB TPN 250 A- 03 Nos, MCCB TPN 160 Amps - 01Nos, MCCB TPN 125 Amps - 02 Nos, MCB TPN 32 Amps - 02Nos for outgoing electric supply . (Note : a) Panels shall be procured from firms having CPRI approval certificate and Existing serviceable siwtch gears obtained from old feeder pillar box will be reused and new switch gears replaced will be measured and paid separately. | ||||||
| 3.00 | Repair/ replacement old U/s LT feeder pillar box with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3mm thick CRCA sheet of suitable size duly pretreated in seven tank process for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. Panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall duly supported on angle iron of size 40x40x4mm thick. panel shall include following accessories: | 2 | Each Job | 1,00,000 ₹2,00,000 | 1,00,000 ₹2,00,000 | 70,000 ₹1,40,000 Lowest |
| 3.01(a) Busbar chamber (4 nos TP&N 600 amp rating ) (Aluminium bus bar ) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assy -03 No (c) complete wiring of panel with suitable guage multi stranded copper conductor with proper colour code (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. (e) Panel should have separate chambers and busbar extensions to accomodate following switch gears. i) MCCB TPN 400 A as incomer - 01 Nos. ii) MCCB 250 Amps - 03 No, MCB TPN 63 A- 02 Nos, MCB TPN 40 Amps - 05 Nos (iii) 63 Amps Contractor & Timer for street light -01 Sets complete. Note : a) Panels shall be procured from firms having CPRI approval certificate and Existing serviceable siwtch gears obtained from old feeder pillar box will be reused and new switch gears replaced will be measured and paid separately.b)panel drawing has to be approved by Engr-in-charge before manufacturing. | ||||||
| 4.00 | Repair/ replacement old U/s LT feeder pillar box with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3mm thick CRCA sheet of suitable size duly pretreated in seven tank process for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. Panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall duly supported on angle iron of size 40x40x4mm thick. panel shall include following accessories | 1 | Each job | 1,05,000 ₹1,05,000 | 1,15,000 ₹1,15,000 | 68,000 ₹68,000 Lowest |
| 4.01(a) Busbar chamber (4 nos TP&N 600 amp rating ) (Aluminium bus bar ) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assy -03 No (c) complete wiring of panel with suitable guage multi stranded copper conductor with proper colour code d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. (e) Panel should have separate chambers and busbar extensions to accomodate following switch gears. i) MCCB TPN 320 Amps as incomer - 01No ii) MCCB TPN 250 Amps - 01 No & MCCB TPN 63 Amps - 08 Nos outgoing . iii) MCB TPN 63 Amps -01 No, Timer with contractor 63 Amps for street light connection - 01 No. Note : a) Panels shall be procured from firms having CPRI approval certificate and Existing serviceable siwtch gears obtained from old feeder pillar box will be reused and new switch gears replaced will be measured and paid separately.b)panel drawing has to be approved by Engr-in-charge before manufacturing. | ||||||
| 5.00 | Repair/ replacement old U/s LT feeder pillar box with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3mm thick CRCA sheet of suitable size duly pretreated in seven tank process for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall duly supported on angle iron of size 40x40x4mm thick. panel shall include following accessories: | 3 | Each Job | 1,05,000 ₹3,15,000 | 1,15,000 ₹3,45,000 | 54,000 ₹1,62,000 Lowest |
| 5.01(a) Busbar chamber (4 nos TP&N 600 amp rating ) (Aluminium bus bar ) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assy -03 No (c) complete wiring of panel with suitable guage multi stranded copper conductor with proper colour code d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. (e) Panel should have separate chambers and busbar extensions to accomodate following switch gears. i) MCCB TPN 320 Amps as incomer - 01No ii) MCCB TPN 250 Amps - 01 No & MCCB TPN 63 Amps - 08 Nos outgoing . iii) MCB TPN 63 Amps -01 No, Timer with contractor 63 Amps for street light connection - 01 No. Note : a) Panels shall be procured from firms having CPRI approval certificate and Existing serviceable siwtch gears obtained from old feeder pillar box will be reused and new switch gears replaced will be measured and paid separately.b)panel drawing has to be approved by Engr-in-charge before manufacturing. | ||||||
| 6.00 | Repair/ replacement old U/s LT feeder pillar box with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3mm thick CRCA sheet of suitable size duly pretreated in seven tank process for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall duly supported on angle iron of size 40x40x4mm thick. panel shall include following accessories: | 1 | Each Job | 45,000 ₹45,000 | 43,000 ₹43,000 Lowest | 59,000 ₹59,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Nov 2025, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2025_MES_734671_1
GE MAINT EZHIMALA 8786
Open Tender
Civil Works
Item Rate
330 days
Ezhimala
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹80,000
Yes
25 Nov 2025
10 Oct 2025
7 Nov 2025
10 Oct 2025
1 Nov 2025
25 Oct 2025
10 Oct 2025 - 17 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tender.pdf
Tender Documents • 1.17 MB
BOQ_822645.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .