Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.7 LAdmitted-Finance | -32.32% | ₹4.7 L | L1 | Admitted-Finance |
| 2 | L2₹5.7 LAdmitted-Finance | -19.21% | ₹5.7 L | L2 | Admitted-Finance |
| 3 | L3₹5.9 LAdmitted-Finance | -16.21% | ₹5.9 L | L3 | Admitted-Finance |
| 4 | L4₹6.0 LAdmitted-Finance B H SANCHETI HOSPITAL HOUSE NO 207 BALDEV NAGAR MASURIYA JODHPUR | JODHPUR | JODHPUR | RAJASTHAN | 342003 | -15.16% | ₹6.0 L | L4 | Admitted-Finance |
| 5 | L5₹6.0 LAdmitted-Finance | -14.99% | ₹6.0 L | L5 | Admitted-Finance |
Tender Value
₹7.0 L
EMD Value
₹14,020
Closing Date
8 May 2026, 6:00 pmClosed
xen electric-I
jda jodhpur
Renovation work at Amritlal Gehlot Stadium Chainpura,Jodhpur.
2026_JDAJO_554816_2
JoDA/Nit-01/Elec-I/2026-27
Open Tender
Electrical Works
60 days
jda jodhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
secretary jda jodhpur and md risl jaipur
₹14,020
Yes
15 May 2026
29 Apr 2026
11 May 2026
29 Apr 2026
8 May 2026
29 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. | - | - | - | - |
| 2 | High Power LED Flood Light Minimum lumen output 15600 lm | 30 | Nos | 4,760 | ₹1,42,800 |
| 3 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. | - | - | - | - |
| 4 | 1 x 2.5 sq.mm | 500 | Mtr. | 35 | ₹17,500 |
| 5 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. | - | - | - | - |
| 6 | 10.0 Sq. mm 4 core | 750 | Mtr | 179 | ₹1,34,250 |
| 7 | Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth. | 700 | Mtr | 145 | ₹1,01,500 |
| 8 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. | 1 | Set | 6,779 | ₹6,779 |
| 9 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. | - | - | - | - |
| 10 | 8 SWG G.I. ( Hot Dipped ) Wire | 25 | Mtr. | 32 | ₹800 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
amritlalstadium.pdf
Tender Documents • 1.72 MB
BOQ_988112.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid