| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.6 LAccepted-AOC | 1 | Accepted-AOC single bid response |
| Sl No | Description | Qty | Unit | Kittu Electricals private limited L1 |
|---|---|---|---|---|
| 1.00Electrification Works | ||||
| 1.00 | OD28220/2025-2026
supply and installation of dust and vermin proof , 3 phase syntax meter board(GS
MB- 6535) and to fix KSEB meters, fuse units , CT etc as required including fixing it
on wall, making good the damages colour washing etc. as required | 1 | each | 3,350 ₹3,350 Lowest |
| 1.00 | 2.13.3
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.100
amps | 1 | each | 1,250 ₹1,250 Lowest |
| 1.00 | OD28221/2025-2026
Supplying and fixing 100, HRC Fuse Base with HRC Fuse link with connections, in
existing meter board | 3 | each | 470 ₹1,410 Lowest |
| 1.00 | OD28222/2025-2026
Supply and installation of 63 A, 2 Way neutral links mounted on DMC/SMC base | 1 | each | 200 ₹200 Lowest |
| 1.00 | 90.11.1.18
Supply and installation of sheet steel, phosphatised and painted, dust and vermin
proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus
and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable
anchor bolts or fixed in recess including cutting hole on the wall , making good the
damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical
DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) | 1 | each | 7,700 ₹7,700 Lowest |
| 1.01 | 90.11.1.10
Supply and installation of sheet steel, phosphatised and painted, dust and vermin
proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus
and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the
damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP
42/43) | 1 | each | 2,700 ₹2,700 Lowest |
| 1.01 | 90.14.10.3
Supply, conveyance and fixing the following types & current rated control gears
& switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in
the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole,
current limiting type MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL | 5 | no | 4,600 ₹23,000 Lowest |
| 1.01 | 2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.63
amps | 1 | each | 1,000 ₹1,000 Lowest |
| 1.01 | 2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps | 1 | each | 3,400 ₹3,400 Lowest |
Tender Value
₹21.2 L
EMD Value
₹50,000
Closing Date
16 Sept 2025, 4:00 pmClosed
PROJECT ENGINEER I,KLDC THRISSUR
Office of the Project EngineerI, K L D C Ltd Thrissur Near Ramanilayam Guest House Thrissur-680020
App 1 Electrification works App 2 SITC of Surveillance system 5MP
2025_KLDC_794067_1
KLDC/ TSR/2025-26/5(1)(PE I)
Open Tender
Electrical Works
Item Rate
360 days
Pananchery GPin Ollur Constituency in Thrissur
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,950
₹50,000
28 Nov 2025
3 Sept 2025
19 Sept 2025
3 Sept 2025
16 Sept 2025
3 Sept 2025
Amount
Electrification Works
OD28220/2025-2026 supply and installation of dust and vermin proof , 3 phase syntax meter board(GS MB- 6535) and to fix KSEB meters, fuse units , CT etc as required including fixing it on wall, making good the damages colour washing etc. as required
2.13.3 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
OD28221/2025-2026 Supplying and fixing 100, HRC Fuse Base with HRC Fuse link with connections, in existing meter board
OD28222/2025-2026 Supply and installation of 63 A, 2 Way neutral links mounted on DMC/SMC base
90.11.1.18 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.10 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.14.10.3 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
OD29551/2025-2026 Supply Conveyance, installation, testing and commissioning of 40A, double pole, single phase 240 volts, MCB type change over switch in the existing MCB DB complete with connections. Make L&T AU series Cat No. AUC00204000 or equivalent
OD29549/2025-2026Supplying and fixing 24 Hours Timer for operating ON-OFF function in the existing MCB DB/enclosure complete with connections,testing and commissioning etc. as required make L&T GIC Time Switch Crono 110-240VAC 1 C/O Base/DIN 25 ON/OFF Model no:67DDT0
OD29550/2025-2026 Supplying and fixing 32A 4pole AC1 Power contactor in the existing MCB DB/enclosure complete with connections,testing and commissioning etc. as required. Make L&T MCX 03 series Cat No. CS97011BOOO or equivalent
90.12.5.40 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.7.40 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
90.12.10.2 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD28263/2025-2026 Supply Conveyance and erection of Kesslec decorative pole 3M height above the ground level made out of GI, tubular pole T washed and prime red. (ASTM A123, with minimum average GI coating of 65?m.), having two sections, bottom section of minimum 1000mm (L) x 140mm dia and the top section with minimum of 2000mm (L) x 76mm dia, in built junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out. Design comply EN40 standard and basic wind speed 169kmph. The embellishments are cast in iron and fitted to the column by grubs screw fitting. The embellishments shall be sealed to the column.The Pole Base plate should be with 250x250x12 mm. The column shall also be provided with flush doorat the bottom with proper strengthening to the cut-out of the door opening. The Pole Shaft/pipe should be fabricated out of Steel tube of grade YST 210/240.The pole shaft and base plate shall be hot dip galvanized (7stage process) as per IS 2629 having minimum average DFT of 65 microns before the coating of epoxy primer. The complete pole treated with high quality epoxy zinc rich primer and thereafter coated with Polyurethane paint (marine grade) of minimum average DFT of 100 microns (Total pole thickness 165 micron). The pole shall have inbuilt junction box consist of connector for loop in loop out and provision for MCB. The pole shall be of composite? construction designed to ?wind load? corresponding to a basic wind speed of 169 kmph without any deformation or damage to the structure. CAT REF: KESSSLEC 3M BLNHEIM HDGI POLE PU PAINTED (MARINE GRADE) or its equivalent make.
OD29547/2025-2026 Supply, Conveyance, installation, testing and commissioning of Philips make Post Top lantern LED fittings BGP161LED2500/NWPSU 220-240/7043N reliable and aesthetically designed symmetric light distribution and limited upward light component and giving connections etc. as required
OD29548/2025-2026 Supply, Conveyance, installation, testing and commissioning of Philips make Surface mounted 12W SM 250 circular led down light colour temperature NW 750 lumen surge protection 2.5 KV with wide voltage protection range 140-270V and giving connections etc. as required.
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.4 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.4 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.5.1 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
OD28238/2025-2026 Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25 x 6 mm brass bolt & nut
90.16.2.2 Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class)
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
OD28239/2025-2026 Steel reinforcement for RCC work including straightening, cutting, bending and placing in position and binding all complete.
14.1 Excavation for foundation in soft soil including dressing of sides and ramming ofbottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.10 Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12 Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
SITC OF SURVEILLANCE SYSTEM 5MP
OD54483/2025-2026 Supply Configuration and fixing of 5MP Bullet IP Camera and giving connections etc as required. {Make - CP Plus}
OD54484/2025-2026 Supply Configuration and fixing of 8 Channel 4K NVR and giving connections etc as required. {Make - CP Plus}
OD54485/2025-2026 Supply and fixing of 4 TB Hard Disk and giving connections etc as required. (Make- WD Purple)
OD54486/2025-2026 Supply and fixing of 4 Port PoE Switch and giving connections etc as required. (Make- TP Link)
OD54487/2025-2026 Supply and fixing of 5 Port Giga Switch and giving connections etc as required. (Make- D-Link)
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.53.2 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required2 run of Cable
1.53.3 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable
OD54489/2025-2026 Supplying and drawn of 4 core OFC Cable in the existing surface/recessed steel/PVC conduit as required.
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
OD54492/2025-2026 Supply and fixing of Media Converter and giving connections etc as required. (Make- Syrotec)
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Bidder Name
Kittu Electricals private limited
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1311904.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .