Providing Incomer Supply and Plate Earthing for CSST Lab in Central Library Building
2024_NITC_812910_1
Engg/EMU/JE3/0007/Space Science Lab
Open Tender
Electrical Works
Item Rate
15 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹13,000
Yes
4 Jul 2024
21 Jun 2024
3 Jul 2024
21 Jun 2024
1 Jul 2024
21 Jun 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
3 x 1.5 sq. mm
6 x 4 sq. mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way , Double door
Supplying and fixing 3 phase 6 way (6+18), double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)
Supplying and fixing 100A, 16kA, 4 pole (Three pole and Neutral), 415 V, Moulded casing circuit breaker (MCCB) in the existing MCCB DB , complete with connections, testing and commissioning etc, as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Triple pole and neutral
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A, 16 KA,TPMCCB
Supply of 1.1 kV grade 4C x 16 sq.mm, Copper conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required.
Supply of 1.1 kV grade 4C x 10 sq.mm, Copper conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required.
Supply of 1.1 kV grade 4C x 4 sq.mm, Copper conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required.
Supply of 1.1 kV grade 3C x 4 sq.mm, Copper conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required.
Supplying and making end termination with brass compression gland and Copper lugs for 4 C x 16 Sq.mm of PVC insulated and XLPE copper conductor cable of 1.1 kV grade as required.
Supplying and making end termination with brass compression gland and Copper lugs for 4 C x 10 Sq.mm of PVC insulated and XLPE copper conductor cable of 1.1 kV grade as required.
Supplying and making end termination with brass compression gland and Copper lugs for 4 C x 4 Sq.mm of PVC insulated and XLPE copper conductor cable of 1.1 kV grade as required.
Supplying and making end termination with brass compression gland and Copper lugs for 3 C x 4 Sq.mm of PVC insulated and XLPE copper conductor cable of 1.1 kV grade as required.
Supply of 1.1 kV grade 3.5C x 35 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
31/2X 35 sq. mm (32mm)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
200 mm width X 50 mm depth X 1.6 mm thickness
Earthing with Copper earth plate 600 mm X 600 mm X 6 mm thickness and copper strip 25 mm X 6 mm to be terminated on copper plate at two places with GI bolt nuts with spring and plate washers.The copper strip to be routed on to the top of the chamber through 4 inches GI pipe. The earth pit should be preferably 900 mm X 900 mm (3ft X 3ft) and depth 10 feet or 3 metres shall be excavated. The copper plate to be buried at depth of 9 feet including all accessories, and providing inspection chamber (concrete box) 300 mm X 300 mm X 300 mm (inside dimension) with lid cover plate approximately 50 mm thick with pulling hook, watering pipe of 2 Inches, 2.7 metre long and pipe should be drilled in Zig Zag manner.Suitable chemical powder of required quantity (60kg) of earthing compound (EXCEL compound or equivalent),25 kg crystal salt and 25 kg Charcoal/ superior materials should be used to improve soil condition.Earthing over all ressistance should be less than 1 ohm and it shall be measured by an approved earthing apparatus.The bidder should provide test certificate as a proof of measurement and value of specified earth ressistance.The succesful Bidder should provide drawing of earth pit arrangement planned.Earthing systems shall be kept in performance check for a minimum period of 1 year and preffered 2 years from the date of commissioning.Second year value the bidder needs to specify in quote.The earthing syatem should be as per the applicable IS/ISO standards.
Providing and fixing 25 mm X 6 mm copper strip on surface or in recess for connections etc. as required.
Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required
Supplying and fixing cable details tags using Aluminium sheet of size 10 cm X 3 cm X 2 mm or nearest size on the existing cable.
Supplying and fixing the identification details of cables and Distribution boards details with vinyl stickers on existing panel board & DB etc. as required
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Submission of as fitted drawing in Autocad and pdf format along with physical copy of the same in the format and standard to get the approval from electrical inspectorate.(along with seal,signature and license details) etc as required.
DIAMOND ENGINEERING WORKS
Sivaprathapan KB
NATIONAL ENGINEERING COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .