Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC 6 GURU GOBIND SINGH NAGAR DHAKOLI DHAKOLI PATIALA PUNJAB 140602 | PATIALA | PUNJAB | 140602 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹19.7 L+₹64,154 (3.36%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L2 | Rejected-Finance Other then L1 |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
10 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE kargil
GE Kargil Ladakh
PROVN OF 01 X TOILET BLOCK WITH ALLIED INFRA FOR TROOPS/VISITORS OF STN HQ, 2 X UG SEPTIC TANK SOAKAGE WELL AT FD WKSP EME, ADDN/ALTN OF 2 X KENNELS INSIDE BLDG T-46 AT MOB FD VET HOSP, HARDSTANDING IN MT LT RGT AND SPL REPAIR TO BLDG NO T-16
2020_MES_332633_7
GE/K-01/2020-21
Open Tender
Civil Works
Item Rate
180 days
Kargil
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Kargil
₹36,000
Yes
20 Oct 2020
25 Sept 2020
12 Oct 2020
25 Sept 2020
10 Oct 2020
28 Sept 2020
60 days
Amount
Surface dressing n.exc 15 cm deep and getting out in hard dense soil.
Surface excavation not exceeding 30 cm deep and average 30 cm deep and getting out in hard/dense soil for roads to required slope gradient, camber etc complete all as specified and directed.
Excavating over areas exc 1.5 mtr wide & n. exc 1.5 mtr deep and getting out in hard/dense soil complete all as specified and directed by Engineer in charge.
All as per above but depth exc 1.5 m and not exc 3.0 m -ditto-
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil.
M & L for PCC 1:2:4 type B-2 ,(using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M & L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, fillings as mass concrete, complete all as specified and directed.
M & L for stone walling random rubble, brought upto courses, well bonded bedded and solidly hearted, built in cement mortar 1:6.
M & L for pre-cast PCC solid block (1:3:6) type C-1 using 20mm graded stone aggregate with solid block exc 10 cm in width and built in CM (1:6), complete all as directed by Engineer-in-Charge.
M & L for providing precast cement concrete solid building blocks or slabs (1:3:6) type C-1 using 20mm graded stone aggregate with solid block 10 cm thick (with plain or interlocking joints as directed) setting in mortar (1:6), complete, in walls.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete complete all as specified.
M & L for hardcore of gauge n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M & L for 100 mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as sub base, complete all as directed.
M & L for 150 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as sub base, finished the surface even and rough to receive floor topping complete all as specified and directed.
M & L for 150 mm thick cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre for hard standing complete all as specified and directed.
M & L for finishing surface of concrete roads, pavements, by brooming complete all as specified and directed.
M & L for forming Contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade 'A' complete all as specified and directed.
M & L for forming 12 mm thick expansion joints for 150 mm thick concrete slab and filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection, finished even and fair without using extra cement, complete all as directed.
M & L for 40 mm thick, plain cement concrete type B-1 (20 mm graded stone aggregate) as in sub base, floors, paving, plinth protection, finished even and fair complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M & L for 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes.
M & L for Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M & L for coloured glazed ceremic tiles in vertical surfaces 350 x 250 x 7 mm thick/ 450 x 350 x 7 mm thick, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick rendering in CM (1:4) as in backing coat for tile complete all as specfied and directed.
S & F 20 mm thick granite machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types including 15 mm thick screed bed as in 1:6 complete all as specified.
Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engr-in-Charge.
M & L for rendering 15mm thick in CM (1:4) on PCC block masonry finished even and fair without using extra cement.
M & L for 15 mm thick rendering in cement mortar 1:6 fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and as directed.
M & L for rendering 10mm thick in CM (1:6) on PCC block masonry internal surfaces of walls finished even and smooth without using extra cement.
S & F expanded metal, n exc 4 Kg per Sq m cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed by Engineer-in-charge.
S & F framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290. Gde-e-165 complete all as specified and directed by Engineer-in-charge.
M & L for preparation of newly plastered surfaces exc 10cm width or girth, of any description and applying two coats of cement based paint over a coat of primer, complete all as directed by Engineer-in-Charge.
M & L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of chalk whitening primer complete all as directed by Engineer-in-Charge.
Taking down chowkat with shutter of any description n.exc 1.5 sqm each and removing from site complete all as directed.
Taking down chowkat with shutter of any description exc 1.5 sq.m but n.exc 4 Sqm each and removing from site complete all as directed.
Dismantling of timber scantling of any description, 40 sqcm and over in section, in any position as in framed work, complete all as specified and directed by Engr-in-Charge.
M & L for clean sawn second class soft-wood timber framed and fixed in scantlings complete all as specified and directed.
S & F second class softwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc complete all as specified and directed.
S & F pre-painted galvalume aluminum zinc coated GI based profiled corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with J type hook, complete all as specified and directed.
S & F pre-painted galvalume aluminum zinc coated GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with J type hook, complete all as specified and directed.
Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar exc. half brick but n.exc one bricks in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work, complete all as specified and directed by Engr-in-Charge.
S & F 4mm thick sheet/figured glass ordinary quality and glazing with oil putty in square not exceeding 0.50 Sqm in each pane, complete all as specified and directed by Engr-in-Charge.
S & F second clas soft wood fillets square or rectangular in section sectional area exceeding 13 sq cm and n exc 25 sq cm as in scantling se-cured with nails or brads complete all as specified and directed.
S & F second clas soft wood fillets square or rectangular in section sectional area exceeding not exc 6 sq cm as in cornics with nails or braeds complete all as specified and directed.
M & L for second class soft wood moulding as in cornices, picture, rails and the like exc.6 sq cm. But not exc 13.0 sqcm secured with nails or brads complete all as specified and directed by Engr-in-Charge.
Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engr-in-Charge.
S & F 6 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed.
S & F 9 mm thick plywood grade BWR, type BB fixed with nails to wooden framework as in ceiling complete all as specified and directed.
S & F 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber rame work complete, all as specified and directed by Engr-in-Charge.
S & F 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber rame work complete, all as specified and directed by Engr-in-Charge.
S & F second class hard wood 35 mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board withcommercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as directed.
S & F 30 mm thick second class soft wood skelton shutters, devided inot squares with plain, chamfered or rounded mitred and rebated sash bars for windows any numbers, size of stiles and rails as specified in SSR (1991) Part-I section 8 clause 8.24 (b), complete all as specified and directed by Engr-in-Charge.
S & F 100 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed complete all as specified and directed.
S & F 200 mm long aluminium anodised, barrel tower bolts of ex- truded section and fixed.
S & F 150 mm long mild steel handles cast type, fitted complete all as specified and directed.
S & F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified.
S & F 75 mm long butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S & F 100 mm long butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S & F 100 mm long butt hinges, heavy weight, cold rolled mild steel, and fixed.
S & F 125 mm long mild steel handles cast type, fitted complete all as specified and directed.
S & F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
M & L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description, not otherwise described, over 10cm width or girth including preparation of surfaces all as specified.
S & F in repairs curtain rail anodised aluminium alloy with fixing brackets, stops, rollers etc all as specified.
S & F 10 liters capacity of Low level PVC flushing cistern including of 32mm dia PVC flush pipe to connect from flushing cistern to water closet (any pattern) and making good all the Joints, all as specified and directed.
S & F PVC connection pipe 15 mm bore with PTMT nuts and 750mm long complete all as specified and directed,
S & F vitreous china wash down water closet pan (Anglo Indian type) semi pedestal pattern, white colour (excluding fixing bolts, flushing cistern, flush pipe) complete all as directed by Engr-in-charge.
S & F plastic water closet seat,white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device.
S & F vitreous china wash basin white ,flat,flate back size 550 x 400 mm excluding taps,waste pipe,chain and plug and procelain stopper but including brackets.
S & F 40 mm dia of waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm- 45gms/40mm-60 gms)
S & F PVC flexible waste pipe, 32 mm dia, suitable for WHBs/sinks/urinal, including threaded PVC socket suitable for shank of waste coupling.
S & F grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms).
S & F bib taps, brass chromium plated, fancy type, screwed down, screwed suitable for 15 mm iron pipe or for brass ferrule and fixed.
S & F 15 mm pillar taps,cast copper alloy fancy type with chromium plated screwed down,screwed for iron pipe or for fixed.
S & F 15 mm dia angle stop valve cast copper alloy, fancy type with chromium plated, screwed both ends for iron pipe or for unions, complete all as directed by Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges fixed with chromium plated screws.
S & F 300 x 300 mm shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms).
S & F 15 mm bore galvanised iron water tubing "Medium Grade", including all fittings, such as tees, bends, elbows, reducers, unions, clamps etc. complete fixed to wall or laid in trenches/ floors, complete all as directed by Engineer-in-Charge.
S & F 20 mm bore galvanised iron water tubing "Medium Grade", including all fittings, such as tees, bends, elbows, reducers, unions, clamps etc. complete fixed to wall or laid in trenches/ floors, complete all as directed by Engineer-in-Charge.
M & L for PVC (SWR) 75 mm diameter of outletfloor trap, plain with grating including jointing with solvent cement to waste pipe fixed in cement concrete type B1 (1:2:4).
M & L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
M & L for Plain cement concrete (1:4:8) type D-2 using 40 mm graded aggregate in concrete bed to drain pipes including packing under & completely surrounding pipes with concrete after they are laid & tested for pipes of 110 mm bore complete all as specified & directed.
M & L for 100 mm thick PCC 1:3:6 type C-2, (using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and surrounding the pipe with concrete after they are laid tested for pipe of 110 mm bore complete all as specified & directed by Engineer in charge.
S & F 110 mm bore PVC (SWR) soil/waste vent pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.
S & F vitreous China Urinal, Half stall type, white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement (excluding flushing cistern, flush pipe and waste pipe).
S & F urinal spreader of cast copper alloy, fancy type with chromium plated, screwed both ends for iron pipe or for unions, complete all as directed by Engineer-in-Charge. fixing with 15 mm dia pipe. (Minimum weight 60gms).
S & F vitreous china urinal partition white of size 310x700 mm terminating about 40 cm above floor line complete all as specified and directed by Engr-in-charge.
M & L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engr-in-charge.
S & F spray jet cast copper alloy, fancy type with chromium plated, screwed both ends for iron pipe or for unions, for vitreous china wash down water closet pan (Anglo Indian type) semi pedestal pattern complete all as specified and directed by Engr-in-charge.
M & L for providing precast reinforced cement concrete 1:2:4 type B1 as in cover slabs & set in CM 1:6.
M & L for mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
S & F for mild steel bars as in rungs & handles including 12 mm dia and over, cut to length, bent to shape required.
M & L for RCC 1:2:4 type B-1, (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns, floors, roofs, landings and in shelves and like complete all as specified and directed by Engineer in charge.
M & L for form work to soffits of suspended curved slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (Horizontal or sloping), flat, fair finished surfaced complete all as specified and directed by Engineer in charge.
M & L for form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed by Engineer in charge.
M & L for Cement concrete1:2:4 type B1 as in surface channels and drains.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.
Supplied only water proofing compound .
S & F 110 mm bore PVC (SWR) vent cowl complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends any radius.
S & F 110 mm borePVC (SWR) junction single, (Single T) equal or unequal .
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soil.
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc.1.50 mtr above the starting point.
Removing excavated material exc. 250 m and n exc 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed.
Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. , complete all as specified and directed by Engr-in-Charge..
Point wiring with multi-stranded copper conductor PVC insulated and unsheathed cable in PVC casing and capping, 1.5 Sqmm with all fittings/accessories and including 1.5 Sqmm PVC insulated copper earth wire connected to common earth including closed recessed wooden terminal Boxes of suitable size made of 2nd class hard wood for mounting switches, sockets etc with 3mm thick laminated sheet cover for one light point or bell/buzzer point controlled by one switch, complete all as specified and directed by Engr-in-Charge..
All as per Srl item here in before but for one 3 pin 5 Amps switch socket on same board.
All as per Srl item here in before but for one 3 pin socket outlet 5 Amps on independent board.
All as per above item but for one 3 pin 15 amps socket outlet independent with copper conductor cable FRLS, PVC insulated & unsheathed multistrand 2.5 sqmm including 1.5 Sqmm PVC insulated copper earth wire -ditto-
S&F Switch piano 5 Amps, single pole one way flush type, complete all as specified and directed by Engr-in-Charge..
S&F Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps Flush type, complete all as specified and directed by Engr-in-Charge.
S&F Switch socket combination 2 in 1, 5 and 15 Amps, Flush type, complete all as specified and directed by Engr-in-Charge.
S&F Lamp holder, insulated body with back plate suitable for batten fittings, complete all as specified and directed by Engr-in-Charge.
S&F Ceiling rose surface bakelite 65x50mm, two to three terminals, complete all as specified and directed by Engr-in-Charge.
Sheet metal enclosure for DB's Single door, single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required, complete all as specified and directed by Engr-in-Charge.
S&F MCB, single pole and neutral, 32 Amp, 240V, 10KA, complete all as specified and directed by Engr-in-Charge.
S&F MCB, single pole, 5 to 32 Amp, 240V, 10KA, complete all as specified and directed by Engr-in-Charge.
Rectangular block of second class hard wood of size 30 x 25 x 5 cm depth, closed recessed, complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED 18 Watt Tubelight fitting decorative ultra slim square profile linear with extruded polycarbonate environment friendly Make Havells Cat part LHEXBTP7INW018, complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm and 6mm thick buried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of plate not less than 1.5 metres below normal ground level, connected to the Galvanized iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron protected by provision of G I light grade pipe 40mm bore including provision of concrete pit in PCC 1:2:4 type B1 using 20mm grade stone aggregate with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs two number and with 6mm dia MS bar handle made to shape and GI medium grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 40mmx8mm flat iron with fixing arrangement funnel wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50M all as per electric plate No 3 of SSR Part-I conected to earth test point as specified or indicated including testing on completion.
S&F insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 Sqmm 2 core complete all as specified
S&F LED bulb 9 watt
Note : - Contract sum will be derived after deduction of Rs. 21215.00 as listed in Schedule `A` Part -II (Schedule of credit).
M/s Aman Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .