Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹43.5 L+₹2.9 L (7.02%)Rejected-Finance 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹46.1 L+₹5.4 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹46.8 L+₹6.2 L (15.1%)Rejected-Finance D NO 71 31 96 6 ASRR COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹47.0 L+₹6.3 L (15.6%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹47.1 L
EMD Value
₹94,200
Closing Date
12 Mar 2021, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
PROVN OF PCC APPROACH PATH TO PARKING SHEDS LOCATED AT DSC SINGLE LIVING ACCN (BLDG NO. P-150) AND MAGAZINE STAFF OFFICE (BLDG NO. P-205), PROVN OF REST ROOM FOR DRIVERS/ MTD AT ADMIN BLOCK OF NAD BHEEMUNIPATNAM, PROVN OF COVERED SHED FOR DG SET IN T
2021_MES_421800_1
GE (P)/N/K/8788 OF 2020-21
Open Tender
Civil Works
Item Rate
120 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹94,200
Yes
17 May 2021
12 Feb 2021
15 Mar 2021
12 Feb 2021
12 Mar 2021
27 Feb 2021
Amount
Demolition of unreinforced cement concrete in ground floor and pavings n. exc. 15cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles portions complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc built in cement mortar complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhats or frames n. exc. 1.5 Sq.m. each but with shutters (without taking off shutters from the frames) complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in hard and dense soil complete all as specified and as directed by the Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as directed.
Removing excavated soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick using soft/loose soil obtained from excavation. complete all as specified and as directed by the Engineer-in-Charge.
M & L for treating the backfill in contact with the foundation at the rate of 7.5 Ltrs of anti termite emulsion per Sqm of vertical surface complete all as specified and as directed.
M&L for treating the top surface of filled earth @ 5 ltrs of anti termite emulsion per Sqm of surface area complete all as specified and as directed.
M&L for treating the soil under plinth protection @ 5 ltrs of anti termite emulsion per Sqm of surface area complete all as specified and as directed.
M&L along the external wall below concrete or masonry apron using anti termite emulsion @2.25 litres per linear metre including drilling and plugging holes etc in apron complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) as in footings, plinth beams and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) as in columns and pillars complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) as in lintel beams, roof beams and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L for Reinforced Cement Concrete M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) in slabs supported on walls and the like complete all as specified and directed.
M&L for Reinforced Cement Concrete M-30 design mix controlled concrete (Using 20mm graded granite stone aggregate) in chajjas and the like complete all as specified and directed.
M&L for precast RCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in landings, cover slabs (for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for Reinforced Cement Concrete,1:1.5:3,type'A1 (Using 20mm graded granite stone aggregate) in foundations, including rafts, footings, plinth beams etc and the like complete all as specified and directed.
M&L for Reinforced Cement Concrete M-35,1:1.5:3,type'A1 (Using 20mm graded granite stone aggregate) in columns, pillars, piers, posts and struts etc and the like complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in sub base/flooring and finishing surface even and smooth using extra cement complete all as specified and as directed by the Engineer- in-Charge.
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection finished even and fair complete all as specified and as directed by the Engineer- in-Charge.
M&L 75mm thick PCC 1:2:4, type B-2 (using 40 mm graded stone aggregate), as in floor/ hard standing and finishing the surface even and smooth with using extra cement complete all as specified and as directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L for brickwork with fly subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L non skid ceramic joint free tiles (coloured) 7 to 8mm thick, area of each tile exceeding. 0.18 but not exceeding 0.38 Sqm (1st quality) conforming to IS-13755 as in floor set and joint in cement slurry, jointed & pointed in white or coloured cement to match the surface of the tile including 20mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and as directed.
M&L non skid ceramic joint free tiles (coloured) 7 to 8mm thick, area of each tile exceeding. 0.18 but not exceeding 0.38 Sqm (1st quality) conforming to IS-13755 as in Skirting /vertical surface set and joint in cement slurry, jointed & pointed in white or coloured cement to match the surface of the tile including 10mm thick backing coat of cement mortar (1:4) complete all as specified and as directed.
M&L for non skid/matt finish ceramic tiles 7mm to 8mm thick area of each tile exc. 0.11 Sq.m. but n. exc. 0.18 Sq.m., in floors etc.set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over screed bed or bedding layer 15mm thick in CM 1:4 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
S&F glazed ceramic tiles in vertical surface 300 x 450 x 6-7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match joint free over rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
S&F for Non skid/matt finish coloured ceramic tiles in vertical surface 600x100x 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match joint free over rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Earth filling under floor spreading and levelling in layers n.exc 15cm thick including well ramming including watering as required complete all as specified and as directed.
M&L for hardcore of gauge n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for 75mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in sub base for flooring complete all as specified and as directed by the Engineer- in-Charge.
Use and waste of form work to sides of foundation/footings, plinth beams and similar work for rough finished surfaces complete all as specified and directed.
Use and waste of form work to sides of columns and pillars for fair finished surfaces complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces complete all as specified and as directed by the Engineer-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work, not exceeding 200mm thick for fair finished surfaces complete all as specified and directed.
Use and waste of formwork to sides and soffits of chajjah, lintel, shelves of slab/ beams and similar work including supports, overhangs, etc finished rough surfaces of concrete flat complete all as specified and as directed.
M & L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F reinforcement TMT steel bars 6mm to 8mm dia. cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia. or securing with clips or welded complete all as specified and as directed by the Engineer-in-Charge.
M & L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S & F Single stanchions, built up of one MS tube conforming to IS-1161-1979 Grade St- 240 with flange plates,caps,bases,splices angle brackets, cleats and other connections all as specified and as directed
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 including painted one shop coat of zinc chromate prime paint including preparation of surfaces complete all as specified and as directed.
M&L for anodised powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
S&F anodised powder coated aluminium door shutters, sliding type without sash bars, aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and suitable anodised aluminium handles and rollers complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
S&F anodised powder coated aluminium window and ventilator shutters, sliding type without sash bars, aluminium sections including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and suitable anodised aluminium handles and rollers complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet (Used instead of plain colour PVC sheet) and edges painted to match with the printed sheet, reinforced with mild steel square tube in opening as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails, mild steel frame covered with heat moulded wood grain printed PVC sheet (used instead of Plain colour PVC sheet) with 5mm thickx15mm wide PVC sheet beading used inside stiles & rails and decorative PVC beading of 10mmx10mm (90O) used instead of exposed portion of PVC sheet beading, panelling of wood grain printed PVC sheet to fit in the mild frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
S&F anodised coloured aluminium grill of design No.DG-117, 10mm thick of DECOGRIL or equivalent make as approved by GE fixed with and including 'F' sections complete all as specified and as directed by the Engineer-in-Charge.
S&F 4.8mm thick plain sheet glass, ordinary quality and glazing with oil putty in square n. exc. 0.5 Sq.m. in each pane complete all as specified and as directed by the Engineer-in-Charge.
S&F 4mm thick figured glass, pin head type & glazing with oil putty including steel pin as in steel frame, in square n-exc. 0.5 sqm in each pane complete all as specified.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by the Engineer-in-Charge.
S&F 125mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed by the Engineer-in-Charge.
S&F 100mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed by the Engineer-in-Charge.
S&F 200mm size aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S&F 150mm size aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S&F 150mm long extruded aluminium alloy handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 300mm long aluminium alloy, anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by the Engineer-in-Charge.
M&L well seasoned Second class HW scantlings clean sawn in framed and fixed work complete all as specified.
S & F plates plain or chequered channels square cut or notched (Ordinary and counter sunk) forming holes with riveted bolted, or welded attachment conforming Fe-410 W (Gde-E-250) quality- A complete all as specified and as directed.
S&F 16 to 20mm dia. mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc.5cm n.exc 10cm long complete all as specified and directed by the Engineer-in-Charge.
S & F 16 to 20mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and secured the other or screwed the both ends each screwed ends to be fitted with washer and one hexagonal or square nuts n.exc 5cm long complete all as directed
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
M&L for rendering 10mm thick with CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 15mm thick with CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L 15 mm thick rendering on fair faces of brick/concrete surfaces in cement mortar 1:4 in two layers of 10mm thick and 5mm thick, finished fair and even and water proofing compound shall be added on top layer as per manufacturer instruction complete all as specified. (Note :- WPC will be measured and paid separately under appropriate item as supply only).
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:3 with water proofing compound and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply only Integral Water Proofing Compound (ISI marked) of approved make.
M&L 5mm thick plaster in CM 1:3 on concrete surfaces of ceilings complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over one coat of primer on walls complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of weather proof exterior emulsion over one coat of primer complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed by the Engineer-in-Charge.
S&F with half Pedestal Wash hand basin of size 550x400 vitreous China (flat back or angle back type) including half pedestal and cutting for and pinning in ends of brackets or erecting stand including supply and fixing of waste coupling, waste pipe etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F grating doom 125mm dia. with waste hole of PTMT (Min weight 40 gms) complete all as specified and as directed by the Engineer-in-Charge.
S&F vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, flushing cistern 10 lts capacity and flush pipe and seat cover etc. complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm dia bore pillar tap cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts. Screwed for iron pipe complete all as specified and as directed.
S&F PVC flexible connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed by the Engineer-in-Charge.
S&F 15mm dia. chromium plated angle stop valves, fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F two way bib cock 15mm dia. chromium plated, fancy type of make Jaquar Catalogue No.FON-40041 or equivalent in CERA complete all as specified and as directed by the Engineer-in-Charge.
S&F health faucet 15mm dia. with one meter long easy flex tube in chromium finish and wall look of make Jaquar Catalogue No.ALD-CHR-565 or equivalent in CERA complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 25mm bore PP-R ball valves(brass insert) high pressure of PTMT (Minimum weight 142 gms) with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed including GI fitting complete all as directed.
S&F 25mm dia. PP-R globe or gate valve with steel ball, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm dia. steel tubing and connections complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20mm dia. steel tubing and connections complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 25mm dia. steel tubing and connections complete all as specified and as directed by the Engineer-in-Charge.
S&F three layer PP-R (Polypropylene random copolymer) pipes of dia 25 mm bore pipes SDR 7.4 & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
All as per Srl item No. 89 here-in-above but for 20 mm dia
All as per Srl item No. 89 here-in-above but for 15 mm dia
M&L for APP based polymeric membrane minimum weighing 3 Kg/Sq.m. and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/Sq.m.) laid on primed surface after applying a coat of blown bitumen 85/25 grade @ 1.20 Kg/Sq.m. over bitumen primer @ 0.50 Kg per Sq.m. by forced application, applying another coat of hot blown bitumen 85/25 grade @ 1.20 Kg per Sq.m. over water proofing membrane and applying a coat of solar reflective bituminous aluminium paint @ 0.10 Kg per Sq.m. all as per the manufacturers instructions, complete all as specified and directed by the Engineer-in-Charge.
S&F PVC (SWR) pipes 40mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC (SWR) pipes 110mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC (SWR) pipes 110mm dia. single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC (SWR) pipes 75mm dia. single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm dia. PVC (SWR) plain bends any radius with access door complete all as specified and directed by the Engineer-in-Charge.
S&F 75mm dia. PVC (SWR) plain bends any radius with access door complete all as specified and directed by the Engineer-in-Charge.
S&F PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and directed by the Engineer-in-Charge.
S&F PVC (SWR) vent cowls 110mm dia. complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC (SWR) multi floor trap 75mm dia. outlet with grating including jointing with solvent cement complete all as specified and directed by the Engineer-in-Charge.
M&L for concrete bed to drain pipes of size 110mm dia. including packing under and completely surrounding pipes with plain cement concrete 1:4:8, type D2 (40mm graded stone aggregate) after they are laid and tested complete all as specified and as directed by the Engineer-in-Charge.
S&F 500 Litres capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) two layered ISI marked hoisted and fixed in position complete all as specified and as directed by the Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm bore drain pipe complete all as directed.
Removing excavated soil exc. 250 m but n exc. 500 m and depositing where directed at a level n exc. 1.5 m above starting point complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over wall care putty of 2mm thick over one coat of primer on walls complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan and power socket etc.) complete including fittings such as switches ceiling roses, pendent, regulators, sockets etc removing materials for taking credit and making good matching to the existing colour to the disturbed surface wall/ floors etc. all as directed by Engineer-in-Charge.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site complete all as specified and as directed. (Note : To be measured only when found serviceable in all respects complete for reuse)
Taking down existing unserviceable distribution board, switch fuse unit, enclosure for MCB / DB(Inclusive of MCBs of any type and capacity) and making good the disturbed surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for concealed point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 V grade multi stranded copper conductor single core cable drawn through and including 20 mm PVC conduit with all fittings and accessories including one run of FRLS PVC insulated and unsheathed single core multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity conductor to common earth and earth dolly including new pressed steel sunken boxes readily available (having thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall not be less than 1.63 mm) concealed type with 3 mm thick bakelite sheet cover for mounting switches, sockets, fan regulator etc including testing complete all as specified and as directed.
All as per Srl Item No. 111 here-in-above but for One light point controlled by two, 2 way switch.
All as per Srl Item No. 111 here-in-above but for One Exhaust/ fan point controlled by one, one way switch 5 Amp and regulator
All as per Srl Item No. 111 here-in-above but for One socket outlet point 3 pin 5 A on independent board.
All as per Srl Item No. 111 here-in-above but for One switch socket outlet point 5 A on same board with other switches
All as per Srl Item No. 111 here-in-above but for one switch socket out let for 16 Amps 3 & 5 pin on independent board with 4.0 Sqmm single core multi stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated and unsheathed single core multi stranded copper conductor cable as earth continuity wire all as specified and as directed.
All as per item no. 111 above but for one bell point controlled by one bell push on the same board with other switches or independent all as specified and as directed.
Material and labour for sub main wiring from DBs to Circuit Board with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into and including concealed rigid PVC conduit medium grade of up to 25 mm dia complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface complete all as specified and as directed.
Material and labour for sub main wiring (With Taking down old aluminium sub main wiring if any) with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade of 25 mm dia complete with fittings and fixings accessories complete and all as specified and as directed.
Supply and fixing switch socket outlet multipurpose 3 pin 5 Amp and one 3 pin 15 amp controlled by and one 15 Amp switch all as specified and as directed
Supply and fixing switch piano flush button single pole one way 5 amps all as specified and as directed
Fixing only Switch flush button single pole one way 5 Amp, 240 volt , complete all as specified and as directed. (Note : Material obtained from Srl Item No. 107 here-in-before shall be used)
S & F Switch flush button single pole two way 5 Amp, 230 volt , complete all as specified and as directed.
S&F switch socket outlet 5 pin 5 amp flush type with including switch all as specified and as directed.
Fixing only switch socket outlet 5 amp flush type with including switch all as specified and as directed. (Note : Material obtained from Srl Item No. 107 here-in-before shall be used)
Supply and fixing ceiling rose surface bakelite 65 x 30 mm three terminals all as specified and as directed.
Fixing only ceiling rose, surfaces bakelite three terminal complete all as specified and as directed. (Note : Material obtained from Srl Item No. 107 here-in-before shall be used)
Supply and fixing fan regulator electronic deluxe rotary step type complete all as specified and as directed.
Fixing only fan regulator any type complete all as specified and as directed. (Note : Material obtained from Srl Item No. 107 here-in-before shall be used)
S&F bell ding dong 5 Amps, flush type, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
S&F bell push switch 6 Amps, flush type, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing sheet metal enclosure for MCCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts , all as specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with dim rail earth and neutral bar , all as specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 4 way with dim rail earth and neutral bar , all as specified and as directed.
Supply and fixing in proper position MCCB four pole of capacity 100 amps, 415 Volts 25kA breaking capacity, all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position,incl taking out old u/s, all as specified and as directed.
Supply and fixing in proper position MCB double pole of capacity 40 to 63 amps, 240 Volts C-series with 10kA breaking capacity, all as specified and as directed.
Supply and fixing MCB TPN of c-series with 10kA breaking capacity up to 63 amps, 440 Volts in proper position all as specified and as directed.
Fixing only Existing light fitting all as specified and as directed.
Supply and fixing indoor luminare decorative batten for wall/ceiling mounting box type energy efficient saving LED BATTEN LIGHT 10 W,230 V,50 HZ, slim integrated design easy install incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. Make:CGCat Part no. LDL -10-CDL or equivalent as approved by GE
Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type Extruded aluminium housing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W,230 V,50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. [Make:CG Cat Part no.CCS-100-20-65-HL2-DP-NWH or equivalent as approved by GE]
Supply 10 W LED decorative CITY 3 wall/surface mounting polycarbonate body suitable for retrofit LED Lamp Base B-22 incl lamp ,all as specified and as directed. Make Havells cat no LHDL06160099 or equivalent as approved by GE
Supply only LED mirror light fittings 07 W,230 V,50 HZ suitable for indoor and outdoor applications complete all as specified and as directed.
Supply and fixing LED bulk head fittings 10 W,230 V,50 HZ suitable for indoor and outdoor applications complete all as specified and as directed. Make Surya cat no SLE BH 10 W or equivalent as approved by GE
Supply and fixing on wall security LED light luminaire fitting 1X25 W and including cable for connection from ceiling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1.5 m long bent to shape including bolt, nut,washer,clamp etc all as specified and as directed by the Engineer-in-charge.
Taking down carefully ceiling fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades for safe custody for reuse and re-assembling the fan complete and refixing the fan in same position including all electrical connection all as specified and as directed.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Supply only ball bearings, bearing No.6201/6202 suitable for ceiling fan/wall mounted/exhaust fan/air circulator of any sweep any make/model complete all as specified and as directed by the Engineer-in-Charge.
All as per item No. 148 above but bearing No.6203/6204. for ceiling/Exhaust fan complete all as specified and as directed by the Engineer-in-Charge.
Supply only fan condenser up to 2.5 mfd suitable for ceiling fan complete all as specified and as directed by the Engineer-in-Charge.
Supply only fan condenser up to 3.15 mfd suitable for ceiling fan complete all as specified and as directed by the Engineer-in-Charge.
M&L for cleaning/preparation of surfaces of ceiling fan 1200mm sweep thoroughly and painting with one coat of spray painting using synthetic enamel white paint over the existing paint and stenciling of MES No. with black paint over it complete all as specified and as directed by the Engineer-in-Charge.
S&F ceiling fan 1200mm sweep, BEE 5 star rated 380 Rpm with high air delivery at low voltages, with double ball bearing in ivory gold/white colour including fixing of regulator, down rod of 19mm dia 300mm long and connecting up with flexible 3 core 1.5sq.mm twisted copper cable from terminal point to ceiling fan complete all as specified and as directed by the Engineer-in-Charge.
S&F Exhaust fan wall mount type 300 mm sweep PVC body Heavy duty , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
S&F Exhaust fan wall mount type 300 mm sweep metal body Heavy duty , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
S&F Exhaust fan wall mount type 250 mm sweep PVC body Heavy duty , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
Supply and fixing AC single phase static Electronic KWH energy meter of accuracy class 1.0,240v,50Hz, with backalite LCD Display, of rating 10-60A with transparent hinged type Box with six month History of energy in KWH with taking down old meter and kept in MES store yard with accessories all as specified and as directed by the Engineer-in-Charge.
Taking down existing unserviceable MS box after disconnecting all electric connection and Supply and fixing factory made enclosure box for mounting meter and DB of size 0.9x0.6x0.2m indoor and wall mounting type made of 2mm thick MS sheet with front side openable with two nos hinged type door with locking arrangement and danger notice board, dust and vermin proof including providing all necessary electrical connection by supply and fixing single core multi stranded copper conductor FRLS cable of appropriate size, making circular hole for cable entry and exit including cable gland of required size, incl two coat of powder coated paint to out side surface and two coat of synthetic enamel paint to inside surface over a coat of red oxide , and making good the disturbed surfaces or wall etc complete incl necessary nut, bolt, washers for mounting on wall and making provisions for mounting electric meters and MCB DBs all as specified and as directed.
Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trench /poles/on wall incl taking out old u/s all as specified and as directed.
Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 3.5 core laid in trench /poles/on wall incl taking out old u/s all as specified and as directed.
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m depth and getting out soft/loose soil for laying of under ground cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and spread clean river sand as cable cushioning for protection of cable to be laid in trenches all as per SSR part I complete all as directed by Engineer-in-Charge. Note: Punned thickness will be measured and paid.
Supply and lay bricks common burnt clay building bricks sub-class B of size 230x113x75 in cable trenches complete all as directed
M&L for galvanized iron tubing 25mm bore light grade with all fittings for protection of FRLS cable, laid in trenches/wall/floor including necessary clamps, bolt/nut complete all as specified and as directed. Note: Earth work excavation will be measured and paid separately.
Drilling of hole horizontally 80/40 mm dia below the road for providing casing pipe of cable protection by using mechanical /hand drill all as specified and as directed.
Supply and fixing lamp holder insulated body suitable for Retrofit lamp all as specified and as directed.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel, complete all as specified and testing on completion.
SAI KRISHNA ASSOCIATES
ARKA CONSTRUCTIONS
SRI RAJA RAJESWARI ENTERPRISES
Raghavendra Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .