Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 LAccepted-Finance | 1 | Accepted-Finance LOWEST | |
| 2 | 2₹1.3 L+₹3,018.38 (2.33%)Accepted-Finance 25 P NO 310 | 2 | Accepted-Finance HEIGHEST |
Tender Value
Refer Docs
EMD Value
₹3,245
Closing Date
4 Mar 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASST ENGINEER
PANTHALAYANI BP
Panthalayini BP Project No S0131 2024 MURINGOLI MEETHAL DWSS CHEMANCHERY GP
2024_LSGD_664060_1
AE/PBP/131/23-24
Open Tender
Electrical Works
Item Wise
180 days
CHEMANCHERY
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹3,245
Yes
16 May 2024
26 Feb 2024
6 Mar 2024
26 Feb 2024
4 Mar 2024
26 Feb 2024
Amount
SITC of Pump set
OD399271/2023-2024:Supply, installation , testing and commissioning of 2 HP Self prime Monoblock Pump set at the existing pump house near the Open well having a discharge of not less than 15000 Ltr/hour at a head of 20 mtrs (Head range 12 to 25 mtrs) with suitable impeller, strainer on suction side etc suitable for operation on Single phase, 230V 50 Hz AC supply in the existing Open well including connection to the delivery line and suction line, including providing and fixing suitable cement concrete plate form and suitable SS/Brass foundation bolt & nuts as necessary, complete as required. ( Make Kirlosker model No : KDS 225+** or equivalent models of , Texmo , Lubi, V gaurd, Crompton, KSB)
OD396759/2023-2024:Providing and fixing 50 mm dia UPVC medium duty column pipe suitable to withstand hydrostatic pressure of 20 Kg/ cm2, from the bottom of Open well to the existing common delivery line with all accessories like, elbows, tees, male threaded adapters, flanges, bottom and top stainless steel pump adaptors etc as required.
OD396763/2023-2024:Supplying and fixing 50 mm dia Foot valve in the existing Pump suction line (Brass or GM)
OD399297/2023-2024:Providing and fixing 40 mm dia UPVC medium duty column pipe suitable to withstand hydrostatic pressure of 20 Kg/ cm2, from the Pump delivery line to the existing OH tank with all accessories like, elbows, tees, male threaded adapters, flanges, bottom and top stainless steel pump adaptors etc as required.
OD396758/2023-2024:Supplying and fixing 40 mm bronze globe valve in the existing UPVC column pipe line with accessories as reqd.
90.17.14.1:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :40mm dia
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
90.14.28.1:S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor
OD399881/2023-2024:SITC of Single Phase Volt meter range 0 to 300 V, and Single Phase Ammeter meter range 0 to 20 A in the existing Cubical Panel Board
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.2:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
90.10.3.17:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A universal socket
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
OD396760/2023-2024:Supply, installation, testing and commissioning of 300 mm sweep, Wall fan i/c , connections using 1.5 sq.mm FR PVC insualted copper conductor 3 core cable etc. as required. Make Almonard/ Crompton Havells.
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
OD399348/2023-2024:SITC of Factory Fabricated wall mounting indoor /Outdoor cubicle type metering main board having front area approximately 0.75 c.m x 0.60 c.m suitable for 1 numbers Single phase electronic energy meters in separate compartment fabricated from 18 SWG thick MS sheet /HDPE Box and supplying and fixing 1 No. HRC Fuse , 1 No Neutral Link and 1 No 25 A 2 Pole RCCB .including , connections & interconnections with 4 sq mm PVC insulated copper conductor cable compartment duly powder coated also provision for fixing Time switch and AC conduct switch etc complete as reqd.
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
OD396750/2023-2024:Extra for using Exel Grounding minerals ( 25 Kg ) compound to reduce the soil resistivity for above earth electrodes etc complete as required
5.11:Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
OD396756/2023-2024:Preparation of drawing and necessary documents Submitting to the KSEB , Getting Single Phase service connection, Including incidental charges, excluding statutory charges.( Below 5 KW)
SHAJI P
Bidder Name
SHAJI P
SASINDRAN E
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .